ENERGY STAR Data Sheet

ENERGY STAR ® Power and Performance Data Sheet
Model Name: Express5800/R120d-2E
System Characteristics
Form Factor
2 socket rack server
Available Processor Sockets
2
Available DIMM Slots / Max Memory Capacity
12slots / 384GB max.
ECC and/or Fully Buffered DIMMs
DDR3-1600 ECC DIMMs
Available Expansion Slots
6
Minimum and Maximum # of Hard Drives
Min.: 1unit ; Max: 26units
Redundant Power Supply Capable?
Yes
Power Supply Make and Model
Delta Electronics DPS-800QB A
Power Supply Output Rating* (watts)
800W
Minimum and Maximum # of Power Supplies
1 to 2
Input Power Range (AC or DC)
115Vac and 230Vac
Power Supply Efficiency at Specified Loadings*
87.40@10%, 91.67@20%, 94.09@50%, 91.95@100%
Power Supply Power Factor at Specified Loadings*
0.89@10%,0.96 @20%, 0.99@50%, 0.99@100%
Microsoft Windows Server 2008 R2 Standard
Microsoft Windows Server 2008 R2 Enterprise etc.
Microsoft Windows Server 2008 R2 Standard
Operating Systems Supported
Installed Operating System for Testing
* Note: Power supply information is for a single power supply only
System Configurations
Minimum
Typical
Maximum
N8100-1846Y
N8100-1846Y
N8100-1821Y
Intel Xeon E5-2420
1.90GHz x2
DDR3-1600
2GB x2
Intel Xeon E5-2420
1.90GHz x2
DDR3-1600
32GB x6
Intel Xeon E5-2430
2.20GHz x2
DDR3-1600
32GB x12
SATA 6Gbps 7200rpm
250GB x1
SAS 6Gbps 10000rpm
900GB x3
SAS 6Gbps 10000rpm
900GB x26
None
SAS Raid Card x1
SAS Raid Card x2
Ethernet card x4
Power Supply Number and Redundancy Configuration
Delta DPS-800QA
800W x1
Delta DPS-800QA
800W x2
Delta DPS-800QA
800W x2
Management Controller or Service Processor Installed?
Yes
Yes
Yes
Minimum
Typical
Maximum
Configuration ID
Processor Information
Memory Information
Internal Storage
I/O Devices
Other Hardware Features / Accessories
Power Data
Idle Category (1S and 2S only)
ENERGY STAR Idle Power Allowance (1S and 2S only)
Category D: Managed Dual Installed Processor (2P) Servers
150W
594W
1224W
Measured Idle Power (watts)
77.3
128.2
354.5
Power at Full Load* (watts)
137.6
189.5
444.1
Benchmark / Method Used for Full Load Test
Use SiSoftware Sandra Engineer (.NET Multi-Media)
230V / 60Hz
Test Voltage and Frequency for Idle and Full Load Test
Range of Total Estimated Energy Usage ** (kWh/year)
1,354 to 2,411
2,246 to 3,320
6,211 to 7,781
Link to Detailed Power Calculator (if available)
* Note: Full load power represents the sustained, average power at 100% load of the given workload, and does not necessarily represent the absolute peak power or the
highest average, sustained power possible for other workloads.
** Note: Estimated kWh/year gives the absolute range of energy use a user could expect from continuous operation (24x7x365) and ranges from 100% Idle usage to 100%
full load operation. The calculation also includes typical data center overhead at a ratio of 1 watt of overhead to every 1 watt of IT load (corresponding to a PUE of 2.0).
Closer approximations may be found by using established power calculators and specific information about the intended operating environment (e.g., average time at
Idle, data center PUE, etc.).
Benchmark #1
Power and Performance for Benchmark #1
Minimum
Maximum
137.6W
189.5W
444.1W
50.81Mpixel/s
50.85Mpixel/s
57.52Mpixel/s
Power Performance Ratio (perf score/avg. power)
0.37
0.27
0.13
Link to Full Benchmark Report (Where Available)
N/A
N/A
N/A
Power and Performance for Benchmark #2 (optional)
Minimum
Typical
Maximum
Benchmark #2
Avg. Power Measured During Benchmark Run
Typical
SiSoftware Sandra Engineer (.NET Multi-Media)
Benchmark Used and Type of Workload
Benchmark Performance Score
Benchmark Used and Type of Workload
Avg. Power Measured During Benchmark Run
Benchmark Performance Score
Power Performance Ratio (perf score/avg. power)
Link to Full Benchmark Report (Where Available)
ENERGY STAR Power and Performance Data Sheet
Model Name: Express5800/R120d-2E
Page 2 of 3
Power Saving Features
Processor Dynamic Voltage and Frequency Scaling
Processor or Core Reduced Power States
Power Capping
Variable Speed Fan Control Based on Power or Thermal Readings
Low Power Memory States
Low Power I/O States
Liquid Cooling Capability
Enabled on
Shipment
End-User Enabling
Required
Yes
Yes
No
Yes
No
No
No
No
No
Yes
No
No
No
No
Other1:
Other2:
Other3:
Other4:
Power and Temperature Measurement and Reporting
Input Power Available & Accuracy?
Yes, +/- 5% for 80W~800W, +/-10W for ~100W
Input Air Temp Available & Accuracy?
Yes, +/- 2(゚c)
Processor Utilization Available?
Yes
Other Data Measurements Available & Accuracy?
Compatible Protocols for Data Collection
IPMI
Averaging method and time period
Non Averaging, 1 sec. interval sampling.
Thermal Information *
Minimum
Typical
Maximum
137.6W
189.5W
444.1W
Delta Temperature at Exhaust at Peak Temp. (˚C)
2.7
3.8
8.1
Airflow at Maximum Fan Speed (CFM) at Peak Temp.
96.3
198.2
110.6
Airflow at Nominal Fan Speed (CFM) at Nominal Temp.
62.8
60.2
52.6
Total Power Dissipation (watts)
* References: ASHRAE Extended Environmental Envelope Final August 1, 2008
Thermal Guidelines for Data Processing Environments, ASHRAE, 2004, ISBN 1-931862-43-5
Peak temperature is defined as 35 ˚C, Nominal Temperature is defined as 18 - 27 ˚C
Notes
1. SPECpower_ssj2008 is a registered trademark of the Standard Performance Evaluation Corporation (SPEC). Benchmark results stated above reflect results published on
XX/XX/XX. For the latest SPECpower_ssj2008 benchmark results, visit http://www.spec.org/power_ssj2008.
ENERGY STAR Qualified Configurations
Include specific information on ENERGY STAR Qualified SKUs or configurations
Qualified Configuration ID: N8100-1846Y, -1821Y, -1816Y, -1843Y
ENERGY STAR Power and Performance Data Sheet
Model Name: Express5800/R120d-2E
Page 3 of 3
ENERGY STAR Qualified Configurations (Continued)
Include specific information on ENERGY STAR Qualified SKUs or configurations