CONDOR DC POWER SUPPLIES INC. 2311 STATHAM PKWY OXNARD, CA 93033 + 805-486-4565 Internet: www.condorpower.com INSTALLATION INSTRUCTIONS GLM110 SERIES MODEL NUMBERS: GLM110-X, where X = 12, 15, 24, 212, 215, or 524. May be followed by suffix –L to indicate optional chassis or –LC to indicate chassis/cover and/or suffix –XXX where XXX may be any number from 001 thru 999 to indicate value added configurations that have no impact on safety and/or suffix G to indicate compliance to RoHS. RATINGS: Input: 100-240 V ac, 2.9 A, 50/60 Hz Output: 0 CFM 0 CFM 26 CFM 60 Watts Max 75 Watts Max 110 Watts Max MODEL Output Volts With Cover Without Cover With or without cover GLM110-12 #1 12 5.0 A 6.3 A 9.1 A GLM110-15 #1 15 4.0 A 5.0 A 7.3 A GLM110-24 #1 24 2.5 A 3.2 A 4.6 A GLM110-212 #1 +12 5.0 A 6.3 A 9.1 A #2 -12 2.5 A 2.5 A 3.0 A GLM110-215 #1 +15 4.0 A 5.0 A 7.3 A #2 2.5 A 2.5 A 3.0 A −15 GLM110-524 #1 +24 2.5 A 3.2 A 4.6 A #2 +5 1.5 A 1.5 A 2.0 A Notes: 1. Maximum ambient temperature for rated output current is 50 °C. 2. Maximum Operating Relative Humidity 96 %, no condensation. 3. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power. CERTIFICATION: All models are Certified to be in compliance with the applicable requirements of UL 60601-1, CSA 22.2 No. 601.1, and EN 60601-1. CLASSIFICATION: (5.1) Protection against electric shock = Class I (In accordance with sub- (5.2) Degree of protection against electric shock = Signal output or intermediate clause 5 of IEC 60601-1) (5.3) Protection against harmful ingress of water = Ordinary (no protection) (5.5) Have not been evaluated for use in the presence of a flammable anaesthetic mixture with air, oxygen, or nitrous oxide. This evaluation is to be made on the end equipment by the OEM. (5.6) Mode of operation = Continuous SAFETY DECLARATION: Condor DC Power Supplies, Inc. declares under our sole responsibility that all models listed above are in conformity with the applicable requirements of EN 60950-1 following the provisions of the Low Voltage Directive 73/23/EEC. GROUNDING: Protection Class I requires that the ground terminal be bonded to Protective Earth in the end application. Using this terminal for the primary system earthing terminal is not recommended. OUTPUTS: Output common or return should be connected to Protective Earth in the end application. The output is intended for Protectively Earthed Signal Output and Intermediate Circuits only. The output is not acceptable for patient connection without additional isolation. The DC output is SELV under normal and single fault conditions. 41-34727-0001 Rev. D 10/21/05 Page 1 of 2 OVERVOLTAGE PROTECTION: The output is monitored for an overvoltage condition. In some applications where an overvoltage condition could result in a hazard as defined in applicable safety standards, redundant or additional overvoltage protection may be required. Consult factory for details. CAUTION: When performing Dielectric Strength Tests, catastrophic failure of the unit may result if a Dielectric Strength test voltage greater than 1800 V ac is applied between primary and secondary circuits. The components providing isolation from primary to secondary cannot be tested while installed in the power supply without overstressing basic (primary to ground) insulation. All isolating components are individually 100 % tested at 4800 V ac prior to installation. ISOLATION: The creepage distance between primary and ground is 4 mm minimum; between primary and secondary circuits is 8 mm minimum. Secondary to ground creepage is not defined or controlled. The required creepage and clearance distances from primary circuits to ground and secondary circuits must be maintained after installation to preserve the intended safety. TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in the applicable safety standards, must not be exceeded after installation to preserve the intended safety. The output power, ambient air temperature and the availability, amount, direction and/or restriction of airflow influence the temperatures of these components. OVERCURRENT PROTECTION: The internal fuse is located in the phase lead only. EN 60601-1 requires that both supply leads (phase and neutral) be protected against overcurrent. Complete overcurrent protection must be provided in the host equipment. Fuse ratings must not exceed that specified for the internal fuse, must meet the requirements of EN EXPLANATION OF SYMBOLS 60601-1, and be acceptable for the country in which the host Alternating Current equipment is to be installed. Direct Current WARNING! RISK OF FIRE! A blown internal fuse is an indication of catastrophic failure of circuit component(s). Refer to fuse marking on the supply for rating. Repair must be performed by Condor authorized personnel. Attention, Consult Accompanying Documents Attention, Dangerous Voltages WARNING! SHOCK HAZARD! Dangerous voltages are present on some components, printed wiring traces and heatsinks. Earth (Ground) CONNECTIONS J1 Pin 1 3 5 AC Input Ground Neutral Line J2 Pin 1 2 3 4 5 6 7 Single Output Models DC Output J2 Pin DC Output + Output 8 Return + Output 9 Return + Output 10 Power Fail + Output 11 N/C Return 12 N/C Return 13 N/C Return MATING CONNECTORS J1 J2 Amp/Tyco Housing 640250-5 Contact 640706-1 Amp/Tyco Housing 1-640250-3 Contact 640706-1 J2 Pin 1 2 3 4 5 6 7 Multi-Output Models DC Output J2 Pin DC Output Output #1 8 Common Output #1 9 Common Output #1 10 Power Fail Output #1 11 N/C Common 12 Output #2 (-) Common 13 Output #2 (+) Common CAUTION: Do not exceed 5 A per contact. Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than authorized agents of Condor DC Power Supplies Inc., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, and EN/IEC safety standards. 41-34727-0001 Rev. D 10/21/05 Page 2 of 2