GLM75 Multi Output Instructions

CONDOR DC POWER SUPPLIES INC.
2311 STATHAM PKWY
OXNARD, CA 93033 + 805-486-4565
RATINGS:
Input: 100-240 V ac, 3.1 A, 50/60 Hz
Output: Maximum Continuous Power,
total of all outputs at ambient of 50 °C.
GLM75 MULTI-OUTPUT SERIES
INSTALLATION INSTRUCTIONS
Standard & -L option
26 CFM
0 CFM
110 Watts 75 Watts
With Chassis/Cover (Note 5)
26 CFM
0 CFM
110 Watts
65 Watts
Output #1
Output #2
Output #3
Output #4
MODEL
Note 2
Note 3
Note 2
Note 3
Note 2
Note 3
Note 2
Note 3
GLM75A +5.1 V
8A
10 A
+12 V 2.5 A 3.0 A -12 V 1.0 A 1.0 A +12 V 2.5 A
3.0 A
GLM75B +5.1 V
8A
10 A
+12 V 2.5 A 3.0 A
-5 V
1.0 A 1.0 A +12 V 2.5 A
3.0 A
GLM75C +5.1 V
8A
10 A
+12 V 2.5 A 3.0 A -15 V 1.0 A 1.0 A +15 V 2.5 A
3.0 A
GLM75D +5.1 V
8A
10 A
+24 V 2.5 A 2.5 A -12 V 1.0 A 1.0 A +12 V 2.5 A
3.0 A
GLM75E +5.1 V
8A
10 A
+24 V 2.5 A 2.5 A -15 V 1.0 A 1.0 A +15 V 2.5 A
3.0 A
GLM75F
+5.1 V
8A
10 A
+15 V 2.5 A 3.0 A
-5 V
1.0 A 1.0 A -15 V 2.5 A
3.0 A
GLM75H +5.1 V
8A
10 A
+15 V 2.5 A 3.0 A -15 V 1.0 A 1.0 A +15 V 2.5 A
3.0 A
GLM75J
+5.1 V
8A
10 A
+12 V 2.5 A 3.0 A -12 V 1.0 A 1.0 A
5V
2.0 A
3.0 A
GLM75P +5.1 V
8A
10 A
+24 V 4.0 A 4.0 A -12 V 1.0 A 1.0 A +12 V 2.5 A
3.0 A
Notes:
1.
Model may be followed by –L for chassis bracket, –C or –LC for chassis/cover, or –V for Voltage Adj. Pot (+5.1V).
2.
Maximum ratings for 0 CFM airflow without chassis/cover.
3.
Maximum ratings for 26 CFM airflow.
4.
Maximum Operating Relative Humidity 96 %, no condensation.
5.
Contact Condor Technical Support for airflow requirements when using chassis/cover option.
6.
Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of
power.
CERTIFICATION: All models are Certified to be in compliance with the applicable requirements of UL
2601-1, CSA 22.2 No. 601.1, EN 60601-1, and IEC 60601-1. Refer to the safety agency certificates for
details.
CLASSIFICATION:
(In accordance with
sub-clause 5
of IEC 60601-1)
(5.1) Protection against electric shock = Class I
(5.2) Degree of protection against electric shock = Signal output or intermediate
(5.3) Protection against harmful ingress of water = Ordinary (no protection)
(5.5) Have not been evaluated for use in the presence of a flammable anaesthetic
mixture with air, oxygen, or nitrous oxide. This evaluation is to be made on the
end equipment by the OEM.
(5.6) Mode of operation = Continuous
SAFETY DECLARATION: Condor DC Power Supplies, Inc. declares under our sole
responsibility that all models listed above are in conformity with the applicable requirements
of EN 60950 following the provisions of the Low Voltage Directive 73/23/EEC.
GROUNDING: The Earth (ground) terminal J1, pin 1, must be bonded to Protective Earth in the end
application to preserve the intended safety. Using the Earth terminal on the supply for grounding the end
product’s protective earthing terminal is not recommended. A separate dedicated protective earthing point
should be used.
OUTPUTS: All output commons should be connected to Protective Earth in the end application. The
output(s) are intended for Protectively Earthed Signal Output and Intermediate Circuits only. The output(s)
are not acceptable for patient connection without additional isolation. All DC outputs are SELV under
normal and single fault conditions.
41-34310-0001 Rev. J
Page 1 of 2
OVERVOLTAGE PROTECTION: Only output #1 is monitored for an overvoltage condition. The trippoint for a 5 volt output is 5.6 to 6.8 volts. In some applications where an overvoltage condition could
result in a hazard as defined in applicable safety standards, redundant or additional overvoltage protection
may be required. Consult factory for details.
CAUTION: When performing Dielectric Strength Tests, catastrophic failure of the unit may result if a
Dielectric Strength test voltage greater than 1800 V ac is applied between primary and secondary circuits.
The components providing isolation from primary to secondary cannot be tested while installed in the
power supply without overstressing basic (primary to ground) insulation. All isolating components are
individually 100 % tested at 4800 V ac prior to installation.
ISOLATION: The creepage distance between primary and ground is 4 mm minimum; between primary
and secondary circuits is 8 mm minimum. Secondary to ground creepage is not defined or controlled. The
output common is bypassed to ground using a 0.01 µF 1 kV capacitor. The required creepage and clearance
distances from primary circuits to ground and secondary circuits must be maintained after installation to
preserve the intended safety.
TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in the
applicable safety standards, must not be exceeded after installation to preserve the intended safety. The
output power, ambient air temperature and the availability, amount, direction and/or restriction of airflow
influence the temperatures of these components.
OVERCURRENT PROTECTION: The internal fuse is located in the phase lead only. UL 2601-1, CSA
22.2 No. 601.1, EN 60601-1, and IEC 60601-1 requires that both supply leads (phase and neutral) be
protected against overcurrent except for permanently installed equipment. Complete overcurrent protection
must be provided in the end equipment. Fuse ratings must not exceed that specified for the internal fuse,
must be acceptable for the country in which the end equipment is to be installed.
WARNING! RISK OF FIRE! A blown internal fuse is an indication of catastrophic failure of circuit
component(s). Repair must be performed by Condor authorized personnel. Refer to fuse marking on the
supply for rating.
WARNING! SHOCK HAZARD! Dangerous voltages are present on some components, printed wiring
traces and heatsinks.
CONNECTIONS
EXPLANATION OF SYMBOLS
Multi-Output Models
Alternating Current
J1 Pin
AC Input
J2 Pin
DC Output
J2 Pin
DC Output
1
Ground
1
Output #1 +
8
Output #2 +
Direct Current
3
Neutral
2
Output #1 +
9
Output #2 +
Attention, Consult
5
Line
3
Output #1 +
10
Power Fail
Accompanying Documents
4
Common
11
Output #3 Attention, Dangerous Voltages
5
Common
12
Output #4 6
Common
13
Output #4 +
Earth (Ground)
7
Common
MATING CONNECTORS
J1 Amp Housing 640250-5 Pin 770522-1
CAUTION
Do not exceed 5 A per contact.
J2 Amp Housing 1-640250-3 Pin 770522-1
Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are
carried out by other than authorized agents of Condor DC Power Supplies Inc., or b) the installation of the supply is not in accordance with these installation
instructions and the applicable UL, CSA, and EN/IEC safety standards.