File E135803 Project 91SC12645 December 11, 1991 REPORT ON COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT Condor DC Power Supplies Inc. Oxnard, California Copyright © 1991 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above named company to reproduce this Report provided it is reproduced in its entirety. Underwriters Laboratories Inc. authorizes the above named company to reproduce that portion of this Report consisting of this Cover Page through Page 4. File E135803 Vol. 1 Sec. 10 and Report Page 1 Issued: Revised: 1991-12-11 2005-02-02 DESCRIPTION PRODUCT COVERED: Component - Switching Power Supplies For Use In Information Technology Equipment, Models GPx130A, GPx130B, GPx130C, GPx130D, GPx130E, SP1290, SP1426, SP1495, and SP1789. All model numbers may be followed by the suffixes -T, T1, -T2, and/or -C. x - Can be either C or M. ELECTRICAL RATINGS: Input: 100-240 V ac, 47-63 Hz, 3.5 A, Model V1 A1 V2 A2 V3 A3 V4 A4 GPx130A +5 20 +12 5.0 -12 1.2 +12 1.2 GPx130B +5 20 +12 5.0 -5 1.2 -12 1.2 GPx130C +5 20 +12 5.0 -15 1.2 +15 1.2 GPx130D +5 20 +24 3.5 -12 1.2 +12 1.2 GPx130E +5 20 +24 3.5 -15 1.2 +15 1.2 SP1290 +5 8 +12 5.0 +16.5 0.5 +16.5 0.5 +5 20 +12 5.0 -5 1.2 -12 3.0 6 +12 2.2 -5.2 1 -12 1 +13.4 4.47 -12 1.2 +12 1.2 SP1426 + SP1495 +5.1 SP1789 +5 20 The units have been evaluated for a maximum ambient of 50°C. + - Model SP1426 has been evaluated with a 35 cfm fan. File E135803 Vol. 1 Sec. 10 Page 2 and Report Issued: 12-11-91 ENGINEERING CONSIDERATION (NOT FOR FIELD REPRESENTATIVE'S USE): This product was investigated under the Standard for Information Technology Equipment, UL 1950, First Edition, dated March 15, 1989. This product is for use only in (or with) complete equipment where the acceptability of the combination is determined by Underwriters Laboratories Inc. Abnormal Tests done at UL were performed with a single layer of cheesecloth over the unit. The Abnormal Test data submitted by the client under the Client Data Program had not been performed with cheesecloth over the unit. This data was accepted due to engineering considerations that a requirement of a 25 CFM fan 4 in. from the unit would keep the unit as cool as if no cheesecloth was on the unit. (It was found that addition of the cheesecloth raised the temperature of the transformer by 23°C). The possibility of a Fire Hazard during abnormals was checked visually. Schematics of the models can be found in the Tests Reference Section. The equipment is considered: Class I (earthed), intended for use on a TN power system. File E135803 Vol. 1 Sec. 10 Page 3 and Report Issued: 12-11-91 Conditions of Acceptability - When installed in the end-use equipment, considerations shall be given to the following: 1. This component has been judged on the basis of the required spacings in the Standard for Information Technology Equipment, Sub-clause 2.9, which would cover the component itself if submitted for unrestricted Listing. 2. This power supply shall be installed in compliance with the enclosure, mounting, creepage, clearance, casualty, markings and segregation requirements of the end-use application. 3. The need for conducting leakage current tests is to be determined as part of the end-product evaluation. 4. This power supply has only been evaluated for use in a pollution degree 2 environment. 5. The input and output connectors have not been evaluated for field connections and are only intended for connection to mating connectors of internal wiring inside the end-use machine. The acceptability of these and the mating connectors relative to secureness, insulating materials, and temperature shall be considered. 6. This power supply shall be properly bonded to earth in the end-use product as this unit was investigated for Class I construction as defined in UL 1950. The bonding terminal has not been investigated as a protective earthing terminal. An additional evaluation shall be made if the power supply is intended for use in other than Class I equipment. 7. The secondary outputs of this power supply are considered SELV. 8. This power supply was evaluated under the assumption that the power source is a TN-S system as defined by UL 1950. File E135803 Vol. 1 Sec. 10 and Report Page 4 Issued: Revised: 1991-12-11 2005-02-02 9. These power supplies have been evaluated for use in a 25°C, 35°C and a 50°C ambient. The end use product shall ensure that a minimum 25 cfm fan is provided with the unit. An additional evaluation should be made if the power supply is intended to be used in an ambient greater than 50°C. 10. The end-use product shall ensure that a fuse replacement warning for the primary fuse is provided. 11. The end use product shall ensure that a 43 cfm fan is provided with the unit if the power supply is provided with a cover. 12. Model SP1426 has been evaluated using a 35 cfm fan. 13. Model SP1789 was originally evaluated for use in a 70°°C ambient. de-rated to 50°°C ambient per client request. It was Certificate of Compliance Certificate: 1893151 (LR 46516) Master Contract: 150684 Project: 1893151 Date Issued: 2007/04/19 Issued to: SL Power Electronics Corp. 7105 Northland Terrace Minneapolis, MN 55428-1534 USA Attention: Mr. Dan Mitchell The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' Issued by: Kourosh Saysan, Eng'g Tech. Authorized by: Shane Stevenson, Product Group Manager PRODUCTS CLASS 5311 07 CLASS 5311 87 CLASS 5311 20 CLASS 5311 96 - POWER SUPPLIES - Component Type - (CSA 60950-1-03) - POWER SUPPLIES - Component Type - Certified to US Stds. - (CSA 60950-1-03/UL 60950-1, First Edition, NRTL Program) - POWER SUPPLIES - Component Type - For Use in Medical Equipment - POWER SUPPLIES - Component Acceptance - Certified to US Standards CLASS 5311 07 / 87 - POWER SUPPLIES - Component Type ! The 'C' and 'US' indicators adjacent to the CSA Mark signify that the product has been evaluated to the applicable CSA and ANSI/UL Standards, for use in Canada and the U.S., respectively. This 'US' indicator includes products eligible to bear the 'NRTL' indicator. NRTL, i.e. National Recognized Testing Laboratory, is a designation granted by the U.S. Occupational Safety and Health Administration (OSHA) to laboratories which have been recognized to perform certification to U.S. Standards. DQD 507 Rev. 2004-06-30 Certificate: 1893151 (LR 46516) Master Contract: 150684 Project: 1893151 Date Issued: 2007/04/19 "# $%&'( )*+ ', &(("-.( / ) , .0"1' 23 '!4 5 64 /7-( 6&/74 6&- /7&!- "&- /7&!- 5 &'( 8 9 ! "# $%&'( )*+ ', &(("-.( / ) , .0"1' 23 '!4 5 64 /7-( 6&/74 "&- /7&!- "4 /7&!- 5 &'( 8 9 ! "# $%&'( )*+ ', &(("-.( / ) , .0"1' 23 '!4 5 64 /7-( 6&/74 "&4 /7&!- 6&4 /7&!- 5 &'( 8 9 ! "# $%&'(: )*+ ', &(("-.( / ) , .0"1' 23 '!4 5 64 /7-( 6-. /7'!4 6&- /7&!- "&- /7&!- 5 &'( 9 ! "# $%&'( )*+ ', &(("-.( / ) , .0"1' 23 '!4 5 64 /7-( 6-. /7'!4 6&4 /7&!- "&4 /7&!- 5 &'( 8 9 ! "# %&-;( )*+ ', &(("-.( / ) , .0"1' 23 '!4 5 64 /7< 6&- /74 6&1!4 /7(!4 "&1!4 /7(!4 5 &&1!4 8 9 ! "# %&.-1 )*+ ', &(("-.( / ) , .0"1' 23 '!4 5 64 /7-( 6&- /74 "&- /7' "4 /7&!- 5 &'( 8 9 ! " # %&.;4 )*+ ', &(("-.( / ) , .0"1' 23 '!4 5 64!& /71!( 6&/7-!-( "4!- /7&!( "&- /7&!( 5 04 8 9 ! CLASS 5311 20 / 96 - POWER SUPPLIES - Component Type - For Use in Medical Equipment # ! "# $%#&'( )*+ ', &(("-.( / ) , .0"1' 23 '!4 5 64 /7-( 6&/74 6&- 7&!- "&- /7&!- 5 &'( 8 9 ! "# $%#&'( )*+ ', &(("-.( / ) , .0"1' 23 '!4 5 64 /7-( 6&/74 "&- /7&!- "4 /7&!- 5 &'( 8 9 ! "# $%#&'( )*+ ', &(("-.( / ) , .0"1' 23 '!4 5 64 /7-( 6&/74 "&4 /7&!- 6&4 /7&!- 5 &'( 8 9 ! "# $%#&'(: )*+ ', &(("-.( / ) , .0"1' 23 '!4 64 /7-( 6-. /7'!4 6&- /7&!- "&- /7&!- 5 &'( 8 9 ! "# $%#&'( )*+ ', &(("-.( / ) , .0"1' 23 '!4 5 64 /7-( 6-. /7'!4 6&4 /7&!- "&4 /7&!- 5 &'( 8 9 ! "# #%&'4< )*+ ', &(("-.( / ) , .0"1' 23 '!4 5 64 /7&- 6&- DQD 507 Rev. 2004-06-30 Certificate: 1893151 (LR 46516) Master Contract: 150684 Project: 1893151 Date Issued: 2007/04/19 /74 6&- /7&!- "&- /7&!- 5 &'( 8 9 ! "# #%&'<( )*+ ', &(("-.( / ) , .0"1' 23 '!4 5 64 /7-( 6&< /7.!1 6&- /7&!- "&- /7&!- 5 &'( 8 9 ! "# #%&4(< )*+ ', &(("-.( / ) , .0"1' 23 '!4 5 64 /7< 6&0 /7- "&0 /7- "4 /7-!4 5 &-& 8 9 ! "# #%&404 )*+ ', &(("-.( / ) , .0"1' 23 '!4 5 64 /7&' 6&0 /7- "&0 /7- "&0 /7- "4 /7-!4 5 &'( 8 9 ! = > &! #9 9 4(? -1 @# ).' @# +,! -! 9 > " A +5 # .' @# ! " A B ! " & A B ! " - A B ! '! 9 > " CCC + + ((& ;;;5 $ D2! APPLICABLE REQUIREMENTS =7 --!- = ("#&;;& " $ D " % =7 --!- = (!."-((. " $ )% + $, =7 --!- = 1(;4("&>-((' " " " % &> $ D =7 --!- = 1(&!&"#;( " # =7E* 1(;4("&"-((- " " " % & " $ D E* 1(1(& & " # % > $ D DQD 507 Rev. 2004-06-30 Supplement to Certificate of Compliance Certificate: Master Contract: 1893151 150684 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Product Certification History Project Date Description 1893151 2007/04/19 Update and Reissue Report LR 46516-122C to Include Minor Report Corrections, add Suffix "G" Denoting RoHS Compliance and Update Name/Address on C of C Descriptive Report and Test Results MASTER CONTRACT: 150684 (LR 46516C) REPORT: 1893151 PROJECT: 1893151 Edition 1: April 19, 2007; Project 1893151 – Vancouver Issued by Kourosh Saysan, Eng’g Tech; Reviewed by Shane Stevenson, AScT. Reviewed by Orest Ewanchyna, P. Eng. Contents: Certificate of Compliance - Pages 1 to 3 Supplement to Certificate of Compliance – Page 1 Description and Tests – Pages 1 to 3 Attachment 1: Category Report No 109, Rev. L, for Subject Models, consisting of: Pages - 1 to 10 Figure - 1 Illustrations – 1 to 19 PRODUCTS CLASS 5311 07 / 87 - POWER SUPPLIES - Component Type Component type power supplies intended for use with Information Technology Equipment Including Electrical Business Equipment, where the suitability of the combination is to be determined by CSA International. Models GPC130A, GPC130B, GPC130C, GPC130D, GPC130E, SP1290, SP1426, SP1495. CLASS 5311 20 / 96 - POWER SUPPLIES - Component Type - For Use in Medical Equipment Component power supplies for use with Medical Equipment, where the suitability of the combination is to be determined by CSA International. Models GPM130A, GPM130B, GPM130C, GPM130D, GPM130E, MSP1358, MSP1380, MSP1508, MSP1575. Notes: 1. 2. 3. Maximum ambient temperature for the maximum rated output power is 50°C with 26 CFM airflow (43 CFM with cover). The following suffixes may be used: - C = Cover; Must use minimum 43 CFM for full rated output power. - T = Terminal block for input and output. - T1 = Terminal block for input only. - T2 = Terminal block for output only. The following suffixes may be used: - XXX indicates value added configurations that have no impact on safety which may be any number from 001 through 999; and G indicates compliance to RoHS. THE STANDARD CSA 60950-1-03/UL 60950-1, 1st EDITION DESIGN MANUAL (ISSUED WITH REPORT 1125259, PROJECT 1722945) IS AN INTEGRAL PART OF THIS REPORT. This report shall not be reproduced, except in full, without the approval of CSA International. 1893151_rep\1\sg DQD 507.10 Rev. 2005-08-31 MASTER CONTRACT: 150684 REPORT: 1893151 PROJECT: 1893151 Page No: 2 Date Issued: April 19, 2007 MARKINGS As described in the attached Category Report No 109 on the subject models. A CSA Mark, adjacent to the submittor's name and/or file number "LR 46516" or submittor's Master Contract "150684". Model designation, complete electrical rating in volts, number of phases and wires, hertz and amperes, and a date code or serial number traceable to the month and year of manufacture and manufacturing facility. ALTERATIONS Markings, as described above, appear on each unit. FACTORY TESTS As described in the attached Category Report No 109 on the subject models. DESCRIPTION The subject model was certified under Category Report No 109 Category file LR 46516C. Please refer to the attached report for full description of the subject models. 1893151_rep\2\sg DQD 507.10 Rev. 2005-08-31 MASTER CONTRACT: 150684 REPORT: 1893151 PROJECT: 1893151 Page No: 3 Date Issued: April 19, 2007 TESTS The tests described in the attached Category Report were performed by the category facility. Edition: 1 (Project 1893151) Re-issued Report LR 46516-122C to include minor report corrections, add suffix "G" denoting RoHS compliance and update name/address on Certificate of Compliance. 1893151_rep\3\sg DQD 507.10 Rev. 2005-08-31