GPC130 Safety Certificates

File E135803
Project 91SC12645
December 11, 1991
REPORT
ON
COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY
EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT
Condor DC Power Supplies Inc.
Oxnard, California
Copyright
©
1991 Underwriters Laboratories Inc.
Underwriters Laboratories Inc. authorizes the above named company to reproduce
this Report provided it is reproduced in its entirety.
Underwriters Laboratories Inc. authorizes the above named company to reproduce
that portion of this Report consisting of this Cover Page through Page 4.
File E135803
Vol. 1
Sec. 10
and Report
Page 1
Issued:
Revised:
1991-12-11
2005-02-02
DESCRIPTION
PRODUCT COVERED:
Component - Switching Power Supplies For Use In Information Technology
Equipment, Models GPx130A, GPx130B, GPx130C, GPx130D, GPx130E, SP1290, SP1426,
SP1495, and SP1789. All model numbers may be followed by the suffixes -T, T1, -T2, and/or -C.
x - Can be either C or M.
ELECTRICAL RATINGS:
Input:
100-240 V ac, 47-63 Hz, 3.5 A,
Model
V1
A1
V2
A2
V3
A3
V4
A4
GPx130A
+5
20
+12
5.0
-12
1.2
+12
1.2
GPx130B
+5
20
+12
5.0
-5
1.2
-12
1.2
GPx130C
+5
20
+12
5.0
-15
1.2
+15
1.2
GPx130D
+5
20
+24
3.5
-12
1.2
+12
1.2
GPx130E
+5
20
+24
3.5
-15
1.2
+15
1.2
SP1290
+5
8
+12
5.0
+16.5
0.5
+16.5
0.5
+5
20
+12
5.0
-5
1.2
-12
3.0
6
+12
2.2
-5.2
1
-12
1
+13.4
4.47
-12
1.2
+12
1.2
SP1426
+
SP1495
+5.1
SP1789
+5
20
The units have been evaluated for a maximum ambient of 50°C.
+ - Model SP1426 has been evaluated with a 35 cfm fan.
File E135803
Vol. 1
Sec. 10
Page 2
and Report
Issued:
12-11-91
ENGINEERING CONSIDERATION (NOT FOR FIELD REPRESENTATIVE'S USE):
This product was investigated under the Standard for Information
Technology Equipment, UL 1950, First Edition, dated March 15, 1989.
This product is for use only in (or with) complete equipment where the
acceptability of the combination is determined by Underwriters Laboratories
Inc.
Abnormal Tests done at UL were performed with a single layer of
cheesecloth over the unit. The Abnormal Test data submitted by the client
under the Client Data Program had not been performed with cheesecloth over the
unit. This data was accepted due to engineering considerations that a
requirement of a 25 CFM fan 4 in. from the unit would keep the unit as cool as
if no cheesecloth was on the unit. (It was found that addition of the
cheesecloth raised the temperature of the transformer by 23°C). The
possibility of a Fire Hazard during abnormals was checked visually.
Schematics of the models can be found in the Tests Reference Section.
The equipment is considered:
Class I (earthed), intended for use on a TN power system.
File E135803
Vol. 1
Sec. 10
Page 3
and Report
Issued:
12-11-91
Conditions of Acceptability - When installed in the end-use equipment,
considerations shall be given to the following:
1.
This component has been judged on the basis of the required spacings in
the Standard for Information Technology Equipment, Sub-clause 2.9, which
would cover the component itself if submitted for unrestricted Listing.
2.
This power supply shall be installed in compliance with the enclosure,
mounting, creepage, clearance, casualty, markings and segregation
requirements of the end-use application.
3.
The need for conducting leakage current tests is to be determined as
part of the end-product evaluation.
4.
This power supply has only been evaluated for use in a pollution degree
2 environment.
5.
The input and output connectors have not been evaluated for field
connections and are only intended for connection to mating connectors of
internal wiring inside the end-use machine. The acceptability of these
and the mating connectors relative to secureness, insulating materials,
and temperature shall be considered.
6.
This power supply shall be properly bonded to earth in the end-use
product as this unit was investigated for Class I construction as
defined in UL 1950. The bonding terminal has not been investigated as a
protective earthing terminal. An additional evaluation shall be made if
the power supply is intended for use in other than Class I equipment.
7.
The secondary outputs of this power supply are considered SELV.
8.
This power supply was evaluated under the assumption that the power
source is a TN-S system as defined by UL 1950.
File E135803
Vol. 1
Sec. 10
and Report
Page 4
Issued:
Revised:
1991-12-11
2005-02-02
9.
These power supplies have been evaluated for use in a
25°C, 35°C and a 50°C ambient. The end use product
shall ensure that a minimum 25 cfm fan is provided with
the unit. An additional evaluation should be made if
the power supply is intended to be used in an ambient
greater than 50°C.
10.
The end-use product shall ensure that a fuse replacement warning for the
primary fuse is provided.
11.
The end use product shall ensure that a 43 cfm fan is provided with the
unit if the power supply is provided with a cover.
12.
Model SP1426 has been evaluated using a 35 cfm fan.
13.
Model SP1789 was originally evaluated for use in a 70°°C ambient.
de-rated to 50°°C ambient per client request.
It was
Certificate of Compliance
Certificate:
1893151 (LR 46516)
Master Contract:
150684
Project:
1893151
Date Issued:
2007/04/19
Issued to:
SL Power Electronics Corp.
7105 Northland Terrace
Minneapolis, MN 55428-1534
USA
Attention: Mr. Dan Mitchell
The products listed below are eligible to bear the CSA Mark shown
with adjacent indicators 'C' and 'US'
Issued by:
Kourosh Saysan, Eng'g Tech.
Authorized by: Shane Stevenson, Product
Group Manager
PRODUCTS
CLASS 5311 07
CLASS 5311 87
CLASS 5311 20
CLASS 5311 96
- POWER SUPPLIES - Component Type - (CSA 60950-1-03)
- POWER SUPPLIES - Component Type - Certified to US Stds. - (CSA
60950-1-03/UL 60950-1, First Edition, NRTL Program)
- POWER SUPPLIES - Component Type - For Use in Medical Equipment
- POWER SUPPLIES - Component Acceptance - Certified to US Standards
CLASS 5311 07 / 87 - POWER SUPPLIES - Component Type
!
The 'C' and 'US' indicators adjacent to the CSA Mark signify that the product has been evaluated to the applicable CSA and ANSI/UL Standards, for use in Canada and the
U.S., respectively. This 'US' indicator includes products eligible to bear the 'NRTL' indicator. NRTL, i.e. National Recognized Testing Laboratory, is a designation granted
by the U.S. Occupational Safety and Health Administration (OSHA) to laboratories which have been recognized to perform certification to U.S. Standards.
DQD 507 Rev. 2004-06-30
Certificate:
1893151 (LR 46516)
Master Contract:
150684
Project:
1893151
Date Issued:
2007/04/19
"# $%&'( )*+ ', &(("-.( / )
, .0"1' 23 '!4 5 64 /7-( 6&/74 6&- /7&!- "&- /7&!- 5 &'( 8 9 !
"# $%&'( )*+ ', &(("-.( / )
, .0"1' 23 '!4 5 64 /7-( 6&/74 "&- /7&!- "4 /7&!- 5 &'( 8 9 !
"# $%&'( )*+ ', &(("-.( / )
, .0"1' 23 '!4 5 64 /7-( 6&/74 "&4 /7&!- 6&4 /7&!- 5 &'( 8 9 !
"# $%&'(: )*+ ', &(("-.( / )
, .0"1' 23 '!4 5 64 /7-( 6-.
/7'!4 6&- /7&!- "&- /7&!- 5 &'( 9 !
"# $%&'( )*+ ', &(("-.( / )
, .0"1' 23 '!4 5 64 /7-( 6-.
/7'!4 6&4 /7&!- "&4 /7&!- 5 &'( 8 9 !
"# %&-;( )*+ ', &(("-.( / )
, .0"1' 23 '!4 5 64 /7< 6&- /74
6&1!4 /7(!4 "&1!4 /7(!4 5 &&1!4 8 9 !
"# %&.-1 )*+ ', &(("-.( / )
, .0"1' 23 '!4 5 64 /7-( 6&- /74
"&- /7' "4 /7&!- 5 &'( 8 9 !
" # %&.;4 )*+ ', &(("-.( / )
, .0"1' 23 '!4 5 64!& /71!( 6&/7-!-( "4!- /7&!( "&- /7&!( 5 04 8 9 !
CLASS 5311 20 / 96 - POWER SUPPLIES - Component Type - For Use in Medical Equipment
# !
"# $%#&'( )*+ ', &(("-.( / )
, .0"1' 23 '!4 5 64 /7-( 6&/74 6&- 7&!- "&- /7&!- 5 &'( 8 9 !
"# $%#&'( )*+ ', &(("-.( / )
, .0"1' 23 '!4 5 64 /7-( 6&/74 "&- /7&!- "4 /7&!- 5 &'( 8 9 !
"# $%#&'( )*+ ', &(("-.( / )
, .0"1' 23 '!4 5 64 /7-( 6&/74 "&4 /7&!- 6&4 /7&!- 5 &'( 8 9 !
"# $%#&'(: )*+ ', &(("-.( / )
, .0"1' 23 '!4 64 /7-( 6-.
/7'!4 6&- /7&!- "&- /7&!- 5 &'( 8 9 !
"# $%#&'( )*+ ', &(("-.( / )
, .0"1' 23 '!4 5 64 /7-( 6-.
/7'!4 6&4 /7&!- "&4 /7&!- 5 &'( 8 9 !
"# #%&'4< )*+ ', &(("-.( / )
, .0"1' 23 '!4 5 64 /7&- 6&-
DQD 507 Rev. 2004-06-30
Certificate:
1893151 (LR 46516)
Master Contract:
150684
Project:
1893151
Date Issued:
2007/04/19
/74 6&- /7&!- "&- /7&!- 5 &'( 8 9 !
"# #%&'<( )*+ ', &(("-.( / )
, .0"1' 23 '!4 5 64 /7-( 6&<
/7.!1 6&- /7&!- "&- /7&!- 5 &'( 8 9 !
"# #%&4(< )*+ ', &(("-.( / )
, .0"1' 23 '!4 5 64 /7< 6&0
/7- "&0 /7- "4 /7-!4 5 &-& 8 9 !
"# #%&404 )*+ ', &(("-.( / )
, .0"1' 23 '!4 5 64 /7&' 6&0
/7- "&0 /7- "&0 /7- "4 /7-!4 5 &'( 8 9 !
=
>
&! #9 9 4(? -1 @# ).' @# +,!
-! 9 >
" A +5 #
.' @# !
" A B !
" & A B !
" - A B !
'! 9 >
" CCC + + ((&
;;;5 $ D2!
APPLICABLE REQUIREMENTS
=7 --!- = ("#&;;& " $ D
" %
=7 --!- = (!."-((. " $ )%
+ $,
=7 --!- = 1(;4("&>-((' " " " %
&> $ D
=7 --!- = 1(&!&"#;( " # =7E* 1(;4("&"-((- " " " %
& " $ D
E* 1(1(& &
" # %
> $ D
DQD 507 Rev. 2004-06-30
Supplement to Certificate of Compliance
Certificate:
Master Contract:
1893151
150684
The products listed, including the latest revision described below, are eligible to be
marked in accordance with the referenced Certificate.
Product Certification History
Project
Date
Description
1893151
2007/04/19
Update and Reissue Report LR 46516-122C to Include Minor Report Corrections, add
Suffix "G" Denoting RoHS Compliance and Update Name/Address on C of C
Descriptive Report
and Test Results
MASTER CONTRACT: 150684 (LR 46516C)
REPORT: 1893151
PROJECT: 1893151
Edition 1:
April 19, 2007; Project 1893151 – Vancouver
Issued by Kourosh Saysan, Eng’g Tech;
Reviewed by Shane Stevenson, AScT.
Reviewed by Orest Ewanchyna, P. Eng.
Contents:
Certificate of Compliance - Pages 1 to 3
Supplement to Certificate of Compliance – Page 1
Description and Tests – Pages 1 to 3
Attachment 1: Category Report No 109, Rev. L, for Subject Models,
consisting of: Pages - 1 to 10
Figure - 1
Illustrations – 1 to 19
PRODUCTS
CLASS 5311 07 / 87 - POWER SUPPLIES - Component Type
Component type power supplies intended for use with Information Technology Equipment Including Electrical
Business Equipment, where the suitability of the combination is to be determined by CSA International.
Models GPC130A, GPC130B, GPC130C, GPC130D, GPC130E, SP1290, SP1426, SP1495.
CLASS 5311 20 / 96 - POWER SUPPLIES - Component Type - For Use in Medical Equipment
Component power supplies for use with Medical Equipment, where the suitability of the combination is to be
determined by CSA International.
Models GPM130A, GPM130B, GPM130C, GPM130D, GPM130E, MSP1358, MSP1380, MSP1508, MSP1575.
Notes:
1.
2.
3.
Maximum ambient temperature for the maximum rated output power is 50°C with 26 CFM
airflow (43 CFM with cover).
The following suffixes may be used:
- C = Cover; Must use minimum 43 CFM for full rated output power.
- T = Terminal block for input and output.
- T1 = Terminal block for input only.
- T2 = Terminal block for output only.
The following suffixes may be used:
- XXX indicates value added configurations that have no impact on safety which may be any
number from 001 through 999; and G indicates compliance to RoHS.
THE STANDARD CSA 60950-1-03/UL 60950-1, 1st EDITION DESIGN MANUAL (ISSUED WITH REPORT 1125259,
PROJECT 1722945) IS AN INTEGRAL PART OF THIS REPORT.
This report shall not be reproduced, except in full, without the approval of CSA International.
1893151_rep\1\sg
DQD 507.10 Rev. 2005-08-31
MASTER CONTRACT: 150684
REPORT: 1893151
PROJECT: 1893151
Page No: 2
Date Issued: April 19, 2007
MARKINGS
As described in the attached Category Report No 109 on the subject models. A CSA Mark, adjacent to the
submittor's name and/or file number "LR 46516" or submittor's Master Contract "150684".
Model designation, complete electrical rating in volts, number of phases and wires, hertz and amperes, and a date
code or serial number traceable to the month and year of manufacture and manufacturing facility.
ALTERATIONS
Markings, as described above, appear on each unit.
FACTORY TESTS
As described in the attached Category Report No 109 on the subject models.
DESCRIPTION
The subject model was certified under Category Report No 109 Category file LR 46516C. Please refer to the
attached report for full description of the subject models.
1893151_rep\2\sg
DQD 507.10 Rev. 2005-08-31
MASTER CONTRACT: 150684
REPORT: 1893151
PROJECT: 1893151
Page No: 3
Date Issued: April 19, 2007
TESTS
The tests described in the attached Category Report were performed by the category facility.
Edition: 1 (Project 1893151)
Re-issued Report LR 46516-122C to include minor report corrections, add suffix "G" denoting RoHS compliance
and update name/address on Certificate of Compliance.
1893151_rep\3\sg
DQD 507.10 Rev. 2005-08-31