GPC130 Instructions

GPC130 SERIES
INSTALLATION INSTRUCTIONS
SL POWER ELECTRONICS CORP.
6050 King Drive, Bldg. A
Ventura, CA 93003 + 805-486-4565
Internet: www.slpower.com
MODEL NUMBERS: GPC130X, where X may be the letter A, B, C, D, E or F. Models may be followed by suffixes: -T, T1, -T2 –C, -XXX and/or G. Suffix –T indicates terminal block used on input and output connectors; -T1 indicates terminal
block used on input; -T2 indicates terminal block used on output; -C indicates cover is provided; -XXX indicates value added
configurations that have no impact on safety which may be any number from 001 thru 999; and G indicates compliance to
RoHS.
RATINGS:
Input: 100-240 V ac, 3.5 A, 50/60 Hz
Outputs:
- 130 Watts Maximum Continuous Power {Total of all Outputs} at 50 °C with 26 CFM airflow.
- 110 Watts Maximum Continuous Power {Total of all Outputs} at 50 °C with convection cooling.
Model
Output #1
Output #2
Output #3
Output #4
GPC130A
+5 V 20 A
+12 V 5.0 A
-12 V 1.2 A
+12 V 1.2 A
GPC130B
+5 V 20 A
+12 V 5.0 A
-5 V 1.2 A
-12 V 1.2 A
GPC130C
+5 V 20 A
+12 V 5.0 A
-15 V 1.2 A
+15 V 1.2 A
GPC130D
+5 V 20 A
+24 V 3.5 A
-12 V 1.2 A
+12 V 1.2 A
GPC130E
+5 V 20 A
+24 V 3.5 A
-15 V 1.2 A
+15 V 1.2 A
GPC130F
+5V 20 A
+15V 4.0 A
-5 V 1.2 A
-15 V 1.2 A
Notes:
1.
2.
3.
4.
Minimum airflow for forced air cooling with cover is 43 cfm.
Operation with cover and no airflow is not recommended.
Maximum operating Relative Humidity 96 %, no condensation.
Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power.
SAFETY DECLARATION: SP Power Electronics Corp. declares under our sole responsibility that all models
listed above are in conformity with the applicable requirements of EN60950-1 following the provisions of the Low
Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the applicable requirements of
UL 1950, CSA 22.2 No. 234 (Level 3), and EN 60950-1 for Pollution Degree 2 environment and Class I TN-S power
systems. The output(s) of these supplies meet the requirements for SELV and are not an energy hazard.
GROUNDING: Protection Class I requires that the chassis and/or J1-5/TB1-3 be bonded to Protective Earth in the end
application. Using J1-5/TB1-3 for the primary system earthing terminal is not recommended.
Creepage and clearance distances from primary circuits to ground and secondary circuits, as defined in the applicable safety
standards, must be maintained after installation to preserve the intended safety.
The maximum operating temperatures of certain safety components, as defined in the applicable safety standards, must not be
exceeded after installation to preserve the intended safety. The output power, ambient air temperature and the availability,
amount, direction and/or restriction of airflow influence the temperatures of these components.
WARNING! RISK OF FIRE!
A blown fuse is an indication of catastrophic failure of circuit component(s). Repair must be performed by SL Power
Electronics Corp. authorized personnel. Fuse F1 must be replaced with F 4 A 250 V, UL Listed and CSA Certified type.
CONNECTIONS
J1
1
3
5
TB1
1
2
3
AC INPUT
Line
Neutral
Ground
J2
1
2
3
4
SIGNAL OUTPUTS
No Connection
Output #1 + Sense
Output #1 - Sense
Power Fail
MATING CONNECTORS:
CAUTION:
Do not exceed 5 A per pin on J3 or
15 A per terminal on TB2.
EXPLANATION OF SYMBOLS
J3
1,2
3,4
5,6
7-12
13-16
TB2
1
2
3
4-6
7,8
DC OUTPUTS
Output #4 (+)
Output #3 (-)
Output #2 (+)
Common
Output #1 (+)
Alternating Current
Direct Current
Attention, Consult
Accompanying Documents
Attention, Dangerous Voltages
Earth (Ground)
J1 AMP Housing 640250-5 Contact 770476-1
J2 Amp 640456-4
J3 AMP Housing 1-640250-6 Contact 770476-1
SL Power Electronics Corp. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried
out by other than authorized agents of SL Power Electronics Corp., or b) the installation of the supply is not in accordance with these installation instructions and the
applicable UL, CSA, IEC/EN safety standards.
41-33109-0001 Rev. G 10/24/06