GLC40 Instructions

SL POWER ELECTRONICS CORP.
6050 King Drive, Bldg. A
Ventura, CA 93003 + 805-486-4565
Internet: www.slpower.com
GLC40 SERIES
INSTALLATION INSTRUCTIONS
MODEL NUMBERS: GLC40A, GLC40B, GLC40D, and GLC40-X, where X represents the output voltage, which may be
any number from 3.3 through 48. Models may or may not be followed by suffix –XXX and/or G, where XXX may be any
number from 001 thru 999. The –XXX suffix are used for value added configurations that have no impact on safety and
suffix G indicates compliance to RoHS.
RATINGS:
Input: 100-240 V ac, 1.3 A, 50/60 Hz
Output: 40 W max or see table for standard output voltage models.
Model
GLC40A
GLC40B
GLC40D
GLC40-3.3
GLC40-5
GLC40-9
GLC40-12
GLC40-15
GLC40-24
GLC40-28
GLC40-48
Watts1
40
40
40
26.4
40
40
40
40
40
40
40
Output #1
+5.1 V dc, 3 A
+5.1 V dc, 3 A
+5.1 V dc, 3 A
3.3 V dc, 8 A
5.0 V dc, 8 A
9.0 V dc, 4.4 A
12.0 V dc, 3.3 A
15.0 V dc, 2.7 A
24.0 V dc, 1.7 A
28.0 V dc ,1.4 A
48.0 V dc, 0.83 A
Output #2
Output #3
+12 V dc, 2 A
-12 V dc, 0.3 A
+15 V dc, 2 A
-15 V dc, 0.3 A
+24 V dc, 1 A
-12 V dc, 0.3 A
Notes:
1. Maximum continuous output power at 50 °C - Total of all Outputs.
2. Maximum Relative Humidity 96 %, no condensation.
3. Storage: -40 to +85 °C. Units should be allowed to warm-up
under non-condensing conditions before application of power.
SAFETY DECLARATION: SL Power Electronics Corp. declares under our sole responsibility that all models
listed above are in conformity with the applicable requirements of EN60950-1 following the provisions of the
Low Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the applicable
requirements of UL 60950, CSA 22.2 No. 60950 (L3M1), and EN 60950-1 for Pollution Degree 2 environment
and Class I TN-S power systems. The outputs of the supplies meet the requirements for SELV and are not an energy hazard.
Protection Class I requires that the ground terminal be bonded to Protective Earth in the end application. Using this terminal
for the primary system earthing terminal is not recommended.
Creepage and clearance distances from primary circuits to ground and secondary circuits, as defined in the applicable safety
standards, must be maintained after installation to preserve the intended safety.
EXPLANATION OF SYMBOLS
The maximum operating temperatures of certain safety components, as defined in the
applicable safety standards, must not be exceeded after installation to preserve the
intended safety. The output power, ambient air temperature and the availability, amount,
direction and/or restriction of airflow influence the temperatures of these components.
WARNING! RISK OF FIRE!
A blown fuse is an indication of catastrophic failure of circuit component(s). Repair
must be performed by SL Power Electronics Corp. authorized personnel. Fuse F1 must
be replaced with T 2 A 250 V (slow blow), UL Listed and CSA Certified type.
J1 Pin
1
3
AC Input
Line
Neutral
CAUTION:
Do not exceed 5 A
per contact.
Mating Connectors:
Contacts:
Amp P/N 640250-3
Amp P/N 770476-1
CONNECTIONS
Multi-Output Models
J2 Pin
DC Output
1
Output #2 (+)
2
Output #1 (+)
3
Output #1 (+)
4
Common
5
Common
6
Output #3 (-)
Amp P/N 640250-6
Amp P/N 770476-1
Alternating Current
Direct Current
Attention, Consult
Accompanying Documents
Attention, Dangerous Voltages
Earth (Ground)
Single Output Models
J2 Pin
Sense
1
Output (+)
2
Output (+)
3
Output (+)
4
Common
5
Common
6
Common
Amp P/N 640250-6
Amp P/N 770476-1
SL Power Electronics Corp. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than
authorized agents of SL Power Electronics Corp., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, IEC/EN
safety standards.
41-33897-0001 Rev. H 9/22/06