GPFC125 Commercial/GPFM125 Medical 125 Watt Global Performance Switchers FEATURES: • • • • • Compact 125 watt multiple output Power density of 4 watts per cubic inch Power Factor Correction to meet EN61000-3-2 Small package 6.00 x 3.5 x 1.5 inches Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) • Commercial approved to UL1950, IEC950, CSA22.2 No. 950 and EN60950. • Medical approved to UL2601-1, IEC601-1, CSA22.2 No. 601.1, EN60601-1 • marked to LVD SPECIFICATIONS: Ac Input Remote Sense 90-264 Vac, 47-63 Hz single phase. Provided as a standard feature on V1 of all models. Input Current Temperature Range Maximum input current 2A at 90 Vac, 60 Hz with full rated load. Input current harmonic content meets the requirements of IEC1000-3-2. Active circuitry provides high power factor as listed at .96 min., .99 typical. All data taken with full output loading. 0 to 50 °C at full rated output power. For operation above 50 °C, derate output power and current by 2.5 % per °C. DC Output Power 125 W with 150 LFM of air, 50 W convection cooled, 80 W convection cooled with unit mounted to min. 12 x 12 x .125 in. thick aluminim plate. Peak ratings are for 60 s maximum duration, 10% duty cycle. With optional cover installed,125 W, 200 LFM airflow is required(-C suffix). Inrush Current Inrush 240 Vac is less than 37 A, averaged over the first ac half-cycle under cold start conditions. Limiting provided by internal thermistors. Input Protection Internal ac fuse provided on all models. Fuse does not blow on overload or short circuit — fuse blows only if a catastrophic failure occurs in the unit. Efficiency 72 to 85% at full rated load. Depending upon model and load distribution. Minimum Load Supply will function with no load on any output. To maintain regulation with full load on V2, 3 and 4 output V1 requires a minimum load of (2A + V4 current). Lower minimum load may be obtained if less then full load is drawn from auxiliary outputs. Overload Protection Fully protected against short circuit and output overload. Total output power limited to approximately 150 Watts. Cycling type limits on output 1, 2 & 3, linear fold back on output 4. Recovery after fault is automatic. Overvoltage Protection Built in on all models - See Output table for individual model output limits. Output Noise 0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Transient Response 500 ms typical response time for return to within 0.5% of final value for a 50% load step change, ∆i/∆t< 0.2 A ms. Maximum voltage deviation is 3.5%. Temperature Coefficient 0.03% / °C typical on all outputs. 52 Altitude Operating: Non-Operating -500 to 10,000 ft. MSL -500 to 40,000 ft MSL Shock and Vibration All models are designed to meet the following specifications; Random Vibration Operating: 0.003 g2/Hz, 1.5 grms overall, 3 axes, 10 min. / axis Non-Operating: 0.026 g2/Hz, 5.0 grms overall, 3 axes, 1 hr. / axis Shock Operating: Half-sine, 20 gpk, 10 ms, 3 axes, 6 shocks total Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6 shocks total EMI/EMC Compliance All models include built-in EMI filtering to meet the EMC requirements below. EMI SPECIFICATIONS COMPLIANCE LEVEL Conducted Emissions-GPFC125 Conducted Emissions-GPFM125 Static Discharge RF Field Susceptibility Fast Transients / Bursts Surge Susceptibility Conducted RF Susceptibility Voltage Sags & Surges Line Frequency Harmonics EN55022, Class B; FCC Class B EN55011,Class B; FCC Class B EN61000-4-2, 6 kV contact 8 kV air EN61000-4-3, 3V/meter EN61000-4-4, 2 kV, 5 kHz EN61000-4-5, 1 kV diff., 2 kV com. EN61000-4-6, 3V EN61000-4-11 EN61000-3-2 Class A Commercial Safety Approvals All models are approved to UL1950, CSA22.2 No. 950-95, IEC950, EN60950. CB certificate available. Exceeds FCC and CISPR22 Class B conducted emissions requirement Medical Safety Approvals All models are Certified to be in compliance with the applicable requirements of UL2601, CSA 22.2 No. 601.1-M90, IEC 601-1 (1988), EN 60601-1: 1990. CB certificate available. Leakage Current The maximum leakage current is as follows: Test Condition Normal Single Fault 132 Vac @ 60 Hz input 70 µA 120 µA 264 Vac @ 50 Hz input 130 µA 240 µA Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com GPFC125 Commercial/GPFM125 Medical 125 Watt Multiple Output Commercial Model GPFC125A Medical Model GPFM125A GPFC125B GPFM125B GPFC125C GPFM125C GPFC125D GPFM125D GPFC125E GPFM125E GPFC125F GPFM125F GPFC125G GPFM125G GPFC125H GPFM125H Voltage Output No. 1 2 3 4 Output Voltage +5 V +12 V 12 V (C) -12 V Output Current (A) 9A 4A 2.5 A 0.3 A Qutput Current (B) 16 A 7A 4A 1A Voltage Adjustment ±5% ±5% --- OVP 6.2 ±0.6 V ---- Total Regulation 1% 1% 1% 1% Ripple/ Noise 1% 1% 1% 1% 1 +5 V 9A 16 A ±5% 6.2 ±0.6 V 1% 1% 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 +12 V 12 V (C) -5 V +5 V +12 V 15 V (C) -15 V +5 V +24 V 12 V (C) -12 V +5 V +24 V 15 V (C) -15 V +5 V +15 V 15 V (C) -5V +5 V +3.3 V 12 V (C) -12 V +3.3 V +5 V 12 V (C) -12 V 4A 2.5 A 0.3 A 9A 4A 2.5 A 0.3 A 9A 3A 2.5 A 0.3 A 9A 3A 2.5 A 0.3 A 9A 3.5 A 2.5 A 0.3 A 9A 7A 2.5 A 0.3 A 9A 4A 2.5 A 0.3 A 7A 4A 1A 16 A 7A 4A 1A 16 A 4.5 A 4A 1A 16 A 4.5 A 4A 1A 16 A 6A 4A 1A 16 A 10 A 4A 1A 16 A 7A 4A 1A ±5% --±5% ±5% --±5% ±5% --±5% ±5% --±5% ±5% --±5% ±5% --±5% ±5% --- ---6.2 ±0.6 V ---6.2 ±0.6 V ---6.2 ±0.6 V ---6.2 ±0.6 V ---6.2 ±0.6 V 4.2 ±0.6 V --4.2 ±0.6 V 6.2 ±0.6 V --- 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 2% 1% 1% 2% 1% 1% 1% Notes: A. Continuous rating for unrestricted convection cooling. B. Peak rating or continuous rating with 150 LFM air cooling. C. Output 3 is isolated. Can be connected as + or - output. GPFC125/GPFM125 MECHANICAL SPECIFICATIONS INPUT: J1 AMP P.C.B. HEADER P/N 640445-5 PIN 1) AC LINE PIN 2) N/C PIN 3) AC NEUTRAL PIN 4) N/C PIN 5) AC GROUND MATING CONNECTOR AMP P/N HOUSING 640250-5 CONTACT 770476-1 SIGNALS: J2 AMP P.C.B. HEADER P/N 640456-4 MATING CONNECTOR P/N 640440-4 PIN 1) POWER FAIL PIN 2) -SENSE PIN 3) +SENSE PIN 4) COMMON OUTPUT: J3 AMP P.C.B HEADER P/N 1-640445-3 PIN 1) -V4OUT PIN 2-4) +V1OUT PINS 5-9) COMMON PIN 10,11) +V2 OUT PIN 12) +V3OUT PIN 13) -V3RTN MATING CONNECTOR AMP P/N HOUSING 1-640250-3 CONTACT 770476-1 OPTIONAL COVER P/N 08-30466-2125 WEIGHT: 1.25 LBS [ .56 KG] Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com 53