Model SWG050 Series Model Parameter SWG050-05 Rated Input Voltage SWG050-12 100 to 240 VAC (140 to 340 VDC) Allowable Input Voltage 85 to 264 VAC (120 to 370 VDC) Input Current (typ) .74 A (100 VAC) / 0.4 A (200 VAC) Rated Frequency 50 / 60 Hz Allowable Frequency Range Input Conditions Efficiency (typ) 47 to 440 Hz or DC AC 100 V 80% 80% 82% AC 200 V 82% 82% 84% Power Factor (typ) 0.99 A (100 VAC) / 0.93 A (200 VAC) Inrush Current (typ)1,2 15 A (VIN = 100 V) / 30 A (VIN = 200 V) IO = 100% at Cold Start 0.40 mA (VIN = 100 V) / 0.75 mA (VIN = 240 V) 60 Hz IO = 100% per measuring method of IEC60950-1 and PSE Leakage Current (max) Rated Output Voltage 5V 12 V 24 V Rated Output Current 10 A 4.3 A 2.2 A Static Input Variation 20 mV max 48 mV max 96 mV max Static Load Variation Ripple3 Output Conditions SWG050-24 Ripple Noise3 Ambient Temperature Variation 40 mV max 100 mV max 150 mV max 0º to 50º C 80 mVp-pmax 120 mVp-pmax 120 mVp-pmax -10º to 0º C 140 mVp-pmax 160 mVp-pmax 160 mVp-pmax 0º to 50º C 120 mVp-pmax 150 mVp-pmax 150 mVp-pmax -10º to 0º C 160 mVp-pmax 180 mVp-pmax 180 mVp-pmax 0º to 50º C 50 mV max 120 mV max 240 mV max -10º to 0º C 60 mV max 150 mV max 290 mV max 20 mV max 48 mV max 96 mV max Time Course Drift4 Startup Time1 350ms typ (VIN = 100 V IO = 100%) Output Holding Time1 20 ms typ (VIN = 100 V IO = 100%) Voltage Variation Range9 4.00 to 5.50 V 10.0 to 13.2 V 19.2 to 27.0 V Voltage Set Point 5.00 to 5.15 V 12.00 to 12.48 V 24.00 to 24.96 V Overcurrent Protection Detection above 105% of rated current (automatic recovery) Additional Functions Overvoltage Protection5 5.75 to 7.00 V Operations Display 15.0 to 18.0 V Operating Temperature Range –10°C to 71°C (with derating) Storage Temperature Range –20°C to 75°C Operating Humidity Range 20% to 90% RH (no condensation) Storage Humidity Range 20% to 90% RH (no condensation) Cooling Requirements Natural air cooling Vibration Frequency Environmental Conditions Vibration Resistance 10 to 55 Hz Sweep Time 3 minutes Acceleration 19.6 m / s2 (2 G) Vibration Direction Vibration Time Shock Resistance Installation Conditions 30.0 to 37.0 V LED Display: Green x, y, z One hour in each of three directions 196.1m/s2 (20G) 11 ms One each of three directions x, y, z Derating may be required due to mounting orientation Continued on the next page… No.PAN40006-001-E00 SANKEN ELECTRIC CO., LTD. 1 All information subject to change without notice October 2014 Continued from the previous page… Model SWG050 Series Model Parameter Insulation Withstand Voltage Insulation7 Insulation Resistance SWG050-05 SWG050-12 SWG050-24 Input-Output 3000 VAC one minute (leakage current 10 mA or less) Input-FG 2000 VAC one minute (leakage current 10 mA or less) Output-FG 500 VAC one minute (leakage current 100 mA or less) Input-Output Input-FG 50 MΩ (measured with 500 VDC Megger) Output-FG Input/Output Type Terminal Stand Dimensions 31 mm (W) X 82 mm (H) X 120 mm (D) (without terminal stand) Weight 280g maximum (without cover) Safety Standards UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, PSE Designed to meet FCC Class B, VCCI Class B, CISPR22 Class B, EN55011 Class B, EN55022 Class B EMI Safety Harmonic Current Designed to meet IEC61000-3-2 Designed to meet EN61000-4-2 (for electrostatic discharge) Others Designed to meet EN61000-4-3 (for radiated, radio-frequency, electromagnetic field) Designed to meet EN61000-4-4 (for transient burst) Electromagnetic Susceptibility Designed to meet EN61000-4-5 (for lightning surge) Designed to meet EN61000-4-6 (for conductive radio frequency electromagnetic field) Designed to meet EN61000-4-8 (for power supply frequency electromagnetic field immunity) Designed to meet EN61000-4-11 (for voltage dip/variation) Environmental Response Options Designed to meet RoHS directive Remote On/Off Yes Connector JST Cover8 Yes 1. Specified under rated input/output conditions at an ambient temperature of 25°C. 2. More current above noted values may flow at restart (ambient temperature of 25°C). 3. Ripple noise is measured with a 20 MHz oscilloscope using a 1:1 probe. 4. Time-course drift is measured between 30 minutes to 8 hours after applying input voltage at rated input/output at an ambient temperature 25ºC. 5. Reset is performed by reapplying input voltage. 6. Output derating may be required. 7. Insulation conditions are specified at normal temperature and humidity. 8. Derating may be required for the power supply with cover. 9. In the case where output voltage is variable, set a voltage such that Output Voltage Variation, Rated Output Current, and Rated Output Power are not exceeded. No.PAN40006-001-E00 SANKEN ELECTRIC CO., LTD. 2 All information subject to change without notice October 2014