SWG100 Datasheet

Model SWG100 Series
Model
Parameter
SWG100-05
Rated Input Voltage
Input Conditions
Allowable Input Voltage
85 to 264 VAC (120 to 370 VDC)
Input Current (typ)
1.3 A (100 VAC) / 0.7 A (200 VAC)
Rated Frequency
50 / 60 Hz
Allowable Frequency Range
47 to 63 Hz
Efficiency (typ)
AC 100 V
82%
AC 200 V
84%
Power Factor (typ)
SWG100-24
81%
84%
83%
86%
0.99 A (100 VAC) / 0.93 A (200 VAC)
Inrush Current (typ)1,2
20 A (VIN = 100 V) / 40 A (VIN = 200 V) IO = 100% at Cold Start
0.40 mA (VIN = 100 V) / 0.75 mA (VIN = 240 V) 60 Hz IO = 100% per measuring method of
IEC60950-1 and PSE
Leakage Current (max)
Rated Output Voltage
5V
12 V
24 V
Rated Output Current
20 A
8.5 A
4.5 A
Static Input Variation
20 mV max
48 mV max
96 mV max
Static Load Variation
40 mV max
100 mV max
150 mV max
Ripple3
Output Conditions
SWG100-12
100 to 240 VAC (140 to 340 VDC)
Ripple Noise3
Ambient Temperature
Variation
0º to 50º C
80 mVp-pmax
120 mVp-pmax
120 mVp-pmax
-10º to 0º C
140 mVp-pmax
160 mVp-pmax
160 mVp-pmax
0º to 50º C
120 mVp-pmax
150 mVp-pmax
150 mVp-pmax
-10º to 0º C
160 mVp-pmax
180 mVp-pmax
180 mVp-pmax
0º to 50º C
50 mV max
120 mV max
240 mV max
-10º to 0º C
60 mV max
150 mV max
290 mV max
48 mV max
96 mV max
Time Course Drift4
20 mV max
Startup Time1
350 ms typ (VIN = 100 V IO = 100%)
Output Holding Time1
20 ms typ (VIN = 100 V IO = 100%)
Voltage Variation Range9
4.00 to 5.50 V
10.0 to 13.2 V
19.2 to 27.0 V
Voltage Set Point
5.00 to 5.15 V
12.00 to 12.48 V
24.00 to 24.96 V
Overcurrent Protection
Detection above 105% of rated current (automatic recovery)
Additional Functions Overvoltage Protection5
5.75 to 7.00 V
Operations Display
15.0 to 18.0 V
LED Display: Green
Operating Temperature Range
–10°C to 71°C (with derating)
Storage Temperature Range
–20°C to 75°C
Operating Humidity Range
20% to 90% RH (no condensation)
Storage Humidity Range
20% to 90% RH (no condensation)
Cooling Requirements
Natural air cooling
Vibration Frequency
Environmental
Conditions
Vibration
Resistance
10 to 55 Hz
Sweep Time
3 minutes
Acceleration
19.6 m / s2 (2 G)
Vibration Direction
Vibration Time
Shock Resistance
Installation Conditions
30.0 to 37.0 V
x, y, z
One hour in each of three directions
196.1m/s2 (20G) 11 ms One each of three directions x, y, z
Derating may be required due to mounting orientation
Continued on the next page…
No.PAN40006-001-E00
SANKEN ELECTRIC CO., LTD.
1
All information subject to
change without notice
October 2014
Continued from the previous page…
Model SWG100 Series
Model
Parameter
Insulation
Withstand
Voltage
Insulation7
Insulation
Resistance
SWG100-05
SWG100-12
SWG100-24
Input-Output
3000 VAC one minute (leakage current 10 mA or less)
Input-FG
2000 VAC one minute (leakage current 10 mA or less)
Output-FG
500 VAC one minute (leakage current 100 mA or less)
Input-Output
Input-FG
50 MΩ (measured with 500 VDC Megger)
Output-FG
Input/Output Type
Terminal Stand
Dimensions
32 mm (W) X 93 mm (H) X 147 mm (D) (without terminal stand)
Weight
440g maximum (without cover)
Safety Standards
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, PSE
Designed to meet FCC Class B, VCCI Class B, CISPR22 Class B, EN55011 Class B,
EN55022 Class B
EMI Safety
Harmonic Current
Designed to meet IEC61000-3-2
Designed to meet EN61000-4-2 (for electrostatic discharge)
Others
Designed to meet EN61000-4-3 (for radiated, radio-frequency, electromagnetic field)
Designed to meet EN61000-4-4 (for transient burst)
Electromagnetic Susceptibility
Designed to meet EN61000-4-5 (for lightning surge)
Designed to meet EN61000-4-6 (for conductive radio frequency electromagnetic field)
Designed to meet EN61000-4-8 (for power supply frequency electromagnetic field
immunity)
Designed to meet EN61000-4-11 (for voltage dip/variation)
Environmental Response
Designed to meet RoHS directive
Remote On/Off
Options
Connector
Yes
JST (escept 5 V output)
Cover8
Yes
1. Specified under rated input/output conditions at an ambient temperature of 25°C.
2. More current above noted values may flow at restart (ambient temperature of 25°C).
3. Ripple noise is measured with a 20 MHz oscilloscope using a 1:1 probe.
4. Time-course drift is measured between 30 minutes to 8 hours after applying input voltage at rated input/output at an ambient temperature 25ºC.
5. Reset is performed by reapplying input voltage.
6. Output derating may be required.
7. Insulation conditions are specified at normal temperature and humidity.
8. Derating may be required for the power supply with cover.
9. In the case where output voltage is variable, set a voltage such that Output Voltage Variation, Rated Output Current, and Rated Output Power are
not exceeded.
No.PAN40006-001-E00
SANKEN ELECTRIC CO., LTD.
2
All information subject to
change without notice
October 2014