TRIFAB® VG 450 (2" SIGHTLINE) OCTOBER, 2010 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC-97911-22 FEATURES FEATURES • • • • • • • • • • Economical 2" sight line 2-1/4" frame depth (Veneer) and 4-1/2" frame depth (Captured) Front glass plane Flush glazed from either the Inside or Outside (Veneer is outside glazed) Stick fabrication SSG / Weatherseal option 1/8", 1/4" or 3/8" infill options Permanodic® anodized finishes in 7 choices Painted finishes in standard and custom choices • • • • Storefront, Ribbon window or Punched openings Low to Mid-rise Single-Span Integrated entrance framing allowing Kawneer standard entrances or other specialty entrances to be included © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. PRODUCT APPLICATIONS For specific product applications, Consult your Kawneer representative. kawneer.com 1 kawneer.com © Kawneer Company, Inc., 2010 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® VG 450 (2" SIGHTLINE) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 OCTOBER, 2010 EC-97911-22 OCTOBER, 2010 TRIFAB® VG 450 (2" SIGHTLINE) 3 INDEX DETAILS 2" x 4-1/2" FRAMING MEMBERS OUTSIDE GLAZED................................................................................ 5 INSIDE GLAZED.................................................................................... 6 OUTSIDE GLAZED with SSG ADAPTER............................................. 7 INSIDE GLAZED with SSG ADAPTER................................................. 8 2" x 2-1/4" VENEER FRAMING MEMBERS OUTSIDE GLAZED................................................................................ 9 OUTSIDE GLAZED SSG...................................................................... 10 CORNERS.................................................................................................. 11 ENTRANCE FRAMING.............................................................................. 12 WINDLOAD CHARTS........................................................................... 13,14 END REACTION CHARTS........................................................................ 15 GUIDE SPECIFICATIONS........................................................................1-4 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC-97911-22 Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com BLANK PAGE kawneer.com © Kawneer Company, Inc., 2010 DETAILS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® VG 450 (2" SIGHTLINE) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 OCTOBER, 2010 EC-97911-22 © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 HEAD kawneer.com 4-1/2" (114.3) TYP. SCALE 3" = 1'-0" 2" (50.8) TYP. 4-1/2" (114.3) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OCTOBER, 2010 EC-97911-22 TRIFAB® VG 450 (2" SIGHTLINE) 5 OUTSIDE GLAZED (2" x 4-1/2") DETAILS 1 4 5 4 JAMB 450-VG-004 450-VG-004 6 2 3 ELEVATION IS NUMBER KEYED TO DETAILS CAD DETAILS = TF_VG_450-2_pg01.dwg 2" (50.8) TYP. 134-WC-001 134-WC-005 134-WC-001 5 VERTICAL 6 JAMB 450-VG-106 4-3/4" (120.7) 450-VG-007 134-WC-011 2 HORIZONTAL 450-VG-026 4-3/4" (120.7) 450-VG-008 3 SILL 450-VG-006 1 HEAD 3 SILL 2" (50.8) TYP. INSIDE GLAZED (2" x 4-1/2") SCALE 3" = 1'-0" 4 5 3 4 JAMB 450-VG-106 6 2 3A ELEVATION IS NUMBER KEYED TO DETAILS CAD DETAILS = TF_VG_450-2_pg02.dwg 2" (50.8) TYP. 134-WC-001 134-WC-005 134-WC-001 5 VERTICAL 450-VG-006 450-VG-108 4-3/4" (120.7) 450-VG-104 2 HORIZONTAL 134 -WC-111 450-VG-104 4-3/4" (120.7) 4-3/4" (120.7) 450-VG-007 450-VG-107 3A SILL 450-VG-006 kawneer.com © Kawneer Company, Inc., 2010 DETAILS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® VG 450 (2" SIGHTLINE) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4-1/2" (114.3) TYP. 4-1/2" (114.3) TYP. 6 OCTOBER, 2010 EC-97911-22 1 6 JAMB © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 134-WC-001 4 JAMB 1 HEAD 3 SILL kawneer.com 2" (50.8) TYP. 4-1/2" (114.3) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OCTOBER, 2010 TRIFAB® VG 450 (2" SIGHTLINE) 7 EC-97911-22 OUTSIDE GLAZED with SSG ADAPTOR (2" x 4-1/2") DETAILS SCALE 3" = 1'-0" 1 4 5 451-SSG-004 6 2 3 ELEVATION IS NUMBER KEYED TO DETAILS CAD DETAILS = TF_VG_450-2_pg03.dwg 2" (50.8) TYP. 134-SSG-005 134-WC-001 5 VERTICAL 6 JAMB 450-VG-106 134-SSG-328 4-3/4" (120.7) 450-VG-007 134 -SSG-111 2 HORIZONTAL 450-VG-104 4-3/4" (120.7) 450-VG-007 134-SSG-328 450-VG-106 8 TRIFAB® VG 450 (2" SIGHTLINE) DETAILS INSIDE GLAZED with SSG ADAPTOR (2" x 4-1/2") SCALE 3" = 1'-0" OCTOBER, 2010 EC-97911-22 4 5 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 6 5A 2 3 ELEVATION IS NUMBER KEYED TO DETAILS CAD DETAILS = TF_VG_450-2_pg04.dwg 2" (50.8) TYP. 134-SSG-005 134-WC-001 134-WC-001 4-1/2" (114.3) TYP. 134-SSG-005 450-SSG-250 450-VG-108 134-SSG-328 450-VG-104 4-3/4" (120.7) 451-SSG-004 134 -SSG-111 2 HORIZONTAL 450-VG-104 4-3/4" (120.7) 450-VG-007 3 SILL 134-SSG-328 450-VG-106 kawneer.com © Kawneer Company, Inc., 2010 450-VG-006 2" (50.8) TYP. 1 HEAD 6 JAMB Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5A WEATHERSWEAL VERTICAL 5 SSG VERTICAL 4 JAMB © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SCALE 3" = 1'-0" 450-087 1 HEAD 3 SILL kawneer.com 2" (50.8) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OCTOBER, 2010 EC-97911-22 TRIFAB® VG 450 (2" SIGHTLINE) 9 OUTSIDE GLAZED (2" x 2-1/4" VENEER) DETAILS 1 4 5 132-WC-005 4 JAMB 2 HORIZONTAL 450-VG-004 6 2 3 ELEVATION IS NUMBER KEYED TO DETAILS CAD DETAILS = TF_VG_450-2_pg05.dwg 2" (50.8) TYP. 132-WC-329 132-WC-005 132-WC-005 450-087 5 VERTICAL 6 JAMB 132-WC-106 132-WC-007 2-1/4" (57.1) TYP. 450-VG-004 132-WC-329 132-WC-011 132-WC-008 132-WC-006 OUTSIDE GLAZED - SSG (2" x 2-1/4" VENEER) 4 450-087 1 HEAD 3 SILL 5 132-WC-005 4 JAMB 2 HORIZONTAL 6 2 3 ELEVATION IS NUMBER KEYED TO DETAILS CAD DETAILS = TF_VG_450-2_pg06.dwg 2" (50.8) TYP. 132-SSG-005 132-WC-329 132-WC-005 5 VERTICAL 132-WC-106 134-SSG-328 132-WC-007 2-1/4" (57.1) TYP. 451-SSG-004 132-WC-329 132-SSG-111 132-WC-007 132-WC-106 134-SSG-328 kawneer.com © Kawneer Company, Inc., 2010 DETAILS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® VG 450 (2" SIGHTLINE) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SCALE 3" = 1'-0" 2" (50.8) TYP. 10 OCTOBER, 2010 EC-97911-22 1 450-087 6 JAMB OCTOBER, 2010 TRIFAB® VG 450 (2" SIGHTLINE) 11 CORNERS DETAILS EC-97911-22 SCALE 3" = 1'-0" CAD DETAILS = TF_VG_450-2_pg07.dwg 4-1/2" (114.3) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 450-VG-015 450-017 450-017 450-VG-015 450-017 60-119 TUBE 450-VG-035 4-1/2" (114.3) TYP. 4-1/2" x 4-1/2" TUBE 450-VG-010 450-VG-010 TWO PIECE NO POCKET CORNER 450-VG-010 BRAKE METAL FILLERS ONE POCKET CORNER TWO POCKET 90o CORNER 450-VG-010 BRAKE METAL FILLERS BRAKE METAL FILLERS TWO POCKET BRAKE METAL POST VARIABLE DEGREE BRAKE METAL OUTSIDE CORNER 450-VG-010 VARIABLE DEGREE BRAKE METAL INSIDE CORNER 450-SSG-016 450-SSG-116 © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 450-VG-010 450-SSG-115450-SSG-116 450-SSG-115 450-SSG-015 450-SSG-135 90o SSG CORNER 90 CORNER o kawneer.com 135o CORNER 135o SSG CORNER 12 TRIFAB® VG 450 (2" SIGHTLINE) DETAILS ENTRANCE FRAMING OCTOBER, 2010 EC-97911-22 SCALE 3" = 1'-0" 451-VG-004 450-022 450-VG-022 134-WC-019 134-WC-019 451-502 451-502 69-177 69-177 FOR SURFACE CLOSER 451-VG-004 450-022 450-VG-022 SINGLE ACTING DOOR JAMBS 451-079 451-079 41-045 41-045 FOR SAM-II COC CLOSER Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CAD DETAILS (C/H with Husky COC) = TF_VG_450-2_Entrance_pg01.dwg (O/P or B/H with Surface Closer) = TF_VG_450-2_Entrance_pg02.dwg (O/P or B/H with Sam-II COC) = TF_VG_450-2_Entrance_pg03.dwg SINGLE ACTING HEADER / TRANSOM BAR 134-WC-019 134-WC-019 451-VG-004 450-022 450-500 TRAY 450-500 TRAY FOR CONCEALED CLOSER DOUBLE ACTING DOOR JAMBS DOUBLE ACTING HEADER / TRANSOM BAR 134-WC-019 134-WC-019 450-VG-033 450-VG-033 TRANSOM AREA Transom area for both double and single acting doors with glass surround. Jambs above transom bar are routed out to accept glass holding Insert (450-VG-033). kawneer.com © Kawneer Company, Inc., 2010 451-081 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 450-VG-022 451-081 OCTOBER, 2010 TRIFAB® VG 450 (2" SIGHTLINE) 13 WINDLOAD CHARTS CHARTS EC-97911-22 WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 WIDTH IN METERS .5 2 10 3 9 A B 2.5 8 7 C D 6 E 5 2 134-WC-005 HEIGHT IN FEET 3.5 11 HEIGHT IN METERS 12 12 3 4 5 6 7 A 10 8 7 2 5 8 1.5 2 1 3 4 5 6 7 8 WIDTH IN FEET WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS .5 1 1.5 WIDTH IN METERS 2 .5 15 1 1.5 2 15 14 4 A 11 B C3 D 10 9 E 8 7 3.5 2.5 2 6 5 1.5 1 2 3 4 5 6 7 WIDTH IN FEET 8 HEIGHT IN FEET 12 4 A B 3.5 13 HEIGHT IN METERS 13 12 11 E 9 7 IA = 2.892 (120.37 X 104) SA = 1.125 (18.44 X 103) 6 1" x 2-1/2" STEEL BAR 4 3 2.5 8 134-WC-005 Is = 1.302 (54.19 X 104) Ss = 1.042 (17.08 X 103) C D 10 2 5 1.5 1 2 3 4 5 6 7 WIDTH IN FEET 8 HEIGHT IN METERS 14 HEIGHT IN FEET 3 B C 2.5 D E 9 4 2 3.5 11 6 I = 2.892 (120.37 X 104) S = 1.125 (18.44 X 103) 1.5 1 4 13 WIDTH IN METERS © Kawneer Company, Inc., 2010 2 HEIGHT IN METERS 4 13 kawneer.com 1.5 14 14 4 1 15 15 4 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. A = 15 PSF (720 Pa) B = 20 PSF (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) E = 40 PSF (1920 Pa) WITH HORIZONTALS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L\175 up to 13'-6" and L\240 + 1/4" above 13'-6". These curves are for mullions WITH and WITHOUT HORIZONTALS and are based on precise engineering calculations for stress and deflection. Allowable windload stress for ALUMINUM 15,152 P.S.I. (104 MPa). STEEL 20,000 P.S.I. (138 MPa). Charted curves, in all cases, are for the limiting value. For special situations not covered by these curves, contact your Kawneer representative for additional information. 14 TRIFAB® VG 450 (2" SIGHTLINE) CHARTS WINDLOAD CHARTS OCTOBER, 2010 WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 WIDTH IN METERS 2 .5 15 14 3 9 A 8 B C D 6 E 5 1 2 3 4 5 6 7 2.5 4 2 134-SSG-005 3.5 11 10 3 A B C 2.5 9 8 D 7 I = 2.672 (111.22 X 10 ) S = 1.437 (23.55 X 103) 6 4 1.5 12 E 5 4 8 1 2 3 4 5 6 7 2 1.5 8 WIDTH IN FEET WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 HEIGHT IN METERS 10 HEIGHT IN FEET 3.5 11 7 WIDTH IN METERS 2 .5 15 1 1.5 2 15 14 4 A 11 3.5 B C3 10 9 2.5 8 7 D 6 E 5 1 2 3 4 5 6 7 WIDTH IN FEET 8 2 1.5 HEIGHT IN FEET 12 4 13 HEIGHT IN METERS 13 12 B C 11 10 3.5 3 9 2.5 8 134-SSG-005 7 IA = 2.672 (111.22 X 104) SA = 1.437 (23.55 X 103) 6 1" x 2-1/2" STEEL BAR 4 Is = 1.302 (54.19 X 104) Ss = 1.042 (17.08 X 103) A D E 5 1 2 3 4 5 6 7 HEIGHT IN METERS 14 HEIGHT IN FEET 2 13 HEIGHT IN METERS HEIGHT IN FEET 12 4 1.5 14 4 13 4 1 15 2 1.5 8 WIDTH IN FEET kawneer.com © Kawneer Company, Inc., 2010 WITH HORIZONTALS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. A = 15 PSF (720 Pa) B = 20 PSF (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) E = 40 PSF (1920 Pa) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC-97911-22 OCTOBER, 2010 TRIFAB® VG 450 (2" SIGHTLINE) 15 END REACTION CHARTS CHARTS EC-97911-22 A = 15 PSF (720 Pa) B = 20 PSF (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) E = 40 PSF (1920 Pa) WITH HORIZONTALS WIDTH IN METERS .5 1 1.5 WIDTH IN METERS 2 .5 14 9 A 2.5 8 7 B 6 2 5 C 1.5 4 D 3 E 450-VG-006 2 3 4 5 6 WIDTH IN FEET 7 8 B 9 C 8 D 7 E 6 3 2.5 2 1.5 4 1 450-VG-106 1 3 2 500lbs. Max. End Reaction 1 10 5 .5 1 3.5 11 HEIGHT IN FEET 3 A 12 HEIGHT IN METERS 10 4 13 3.5 11 © Kawneer Company, Inc., 2010 2 .5 1 0 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 12 kawneer.com 1.5 14 4 13 0 1 15 2 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. WITHOUT HORIZONTALS 15 HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. For each application, end reactions MUST be checked. These charts are used to verify that the end reactions at the head and sill receptors are 500 lbs. (2224N) or less and will meet the specified windload.