TRIFAB® 400 OCTOBER, 2010 FEATURES Features • • • • • • • Trifab® 400 is 4" deep with a 1-3/4" sightline Center plane glass applications Flush glazed from either the inside or outside Screw Spline, Shear Block or Stick fabrication 1/8", 1/4" or 3/8" infill options Permanodic® anodized finishes in 7 choices Painted finishes in standard and custom choices Product Applications • • • • Storefront, Ribbon Window or Punched Openings Single-span Integrated entrance framing allowing Kawneer standard entrances or other specialty entrances to be incorporated GLASSvent™ is easily incorporated © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-22 For specific product applications, Consult your Kawneer representative. kawneer.com 1 kawneer.com © Kawneer Company, Inc., 2010 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® 400 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 OCTOBER, 2010 EC 97911-22 TRIFAB® 400 OCTOBER, 2010 INDEX PICTORIAL VIEWS............................................................................ 4-6 BASIC FRAMING MEMBERS........................................................... 7,8 ENTRANCE FRAMING.................................................................... 9,10 MISCELLANEOUS FRAMING............................................................ 11 GLASSventTM . .............................................................................. 12,13 WINDLOAD CHARTS.................................................................... 14-19 DEADLOAD CHARTS........................................................................ 20 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-22 3 Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com TRIFAB® 400 OCTOBER, 2010 PICTORIAL VIEW (SCREW SPLINE ASSEMBLY) EC 97911-22 SCREW SPLINE MULLION SPLINE SCREW SNAP-IN FILLER HEAD INTERMEDIATE HORIZONTAL SNAP-IN FILLER SILL SILL FLASHING GLASS STOP kawneer.com © Kawneer Company, Inc., 2010 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. THE SPLIT VERTICAL IN THE SCREW SPLINE SYSTEM ALLOWS A FRAME TO BE INSTALLED FROM UNITIZED ASSEMBLIES. SCREWS ARE DRIVEN THROUGH THE BACK OF THE VERTICALS INTO SPLINES EXTRUDED IN THE HORIZONTAL FRAMING MEMBERS. THE INDIVIDUAL UNITS ARE THEN SNAPPED TOGETHER TO FORM A COMPLETED FRAME. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OCTOBER, 2010 kawneer.com TRIFAB® 400 EC 97911-22 PICTORIAL VIEW (SHEAR BLOCK ASSEMBLY) THE SHEAR BLOCK SYSTEM OF FABRICATION ALLOWS A FRAME TO BE PRE ASSEMBLED AND INSTALLED AS A SINGLE UNIT. HORIZONTALS ARE ATTACHED TO THE VERTICALS WITH SHEAR BLOCKS. MULLION SHEAR BLOCK AT HEAD HEAD INTERMEDIATE HORIZONTAL SHEAR BLOCK AT HORIZONTAL/SILL FLASHING GLASS STOP SILL 5 OCTOBER, 2010 PICTORIAL VIEW (STICK ASSEMBLY) EC 97911-22 THE STICK SYSTEM OF FABRICATION ALLOWS ON-SITE ASSEMBLY. HEAD AND SILL RECEPTORS ARE FASTENED TO THE SURROUND. VERTICAL MULLIONS ARE THEN INSTALLED IN THESE RECEPTORS AND ARE HELD IN PLACE BY SNAP-IN INSERTS. INTERMEDIATE HORIZONTAL MEMBERS ARE ATTACHED TO THE VERTICALS WITH SHEAR BLOCKS. FLASHING IS NOT REQUIRED. NOTE: IF END REACTION OF THE MULLION (MULLION SPACING (ft.) TIMES HEIGHT (ft.) TIMES SPECIFIED WINDLOAD (psf) DIVIDED BY TWO) IS MORE THAN 500 LBS. THE OPTIONAL HEAVYWEIGHT HEAD/SILL RECEPTOR 400-006 MUST BE USED. (See Page 11 for details) LIGHTWEIGHT HEAD RECEPTOR HEAD INSERT TUBE MULLION SHEAR BLOCK AT HORIZONTAL INTERMEDIATE HORIZONTAL Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® 400 SILL INSERT LIGHTWEIGHT SILL RECEPTOR WEEP HOLES AT 1/4 POINTS (Typical) kawneer.com © Kawneer Company, Inc., 2010 SNAP-IN FILLER Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 6 TRIFAB® 400 OCTOBER, 2010 EC 97911-22 BASIC FRAMING MEMBERS 3 4 5 ELEVATION IS NUMBER KEYED TO DETAILS SCREW SPLINE SYSTEM CAD DETAILS = Trifab_400_pg01.dwg SHEAR BLOCK SYSTEM STICK SYSTEM CAD DETAILS = Trifab_400_pg02.dwg CAD DETAILS = Trifab_400_pg03.dwg 1-3/4" (44.5) TYP. 1-3/4" (44.5) TYP. 400-005 1 VERTICAL MULLION 2 JAMB 1 VERTICAL MULLION 3 HEAD 400-012 2 JAMB 4" (101.6) TYP. 4" (101.6) TYP. 4 INTERMEDIATE HORIZONTAL 400-004 400-003 4 INTERMEDIATE HORIZONTAL 400-012 1 VERTICAL MULLION 2 JAMB 3 LIGHTWEIGHT HEAD 400-012 400-001 400-005 2" (50.8) 400-001 1-3/4" (44.5) TYP. 400-001 4" (101.6) 4" (101.6) 4" (101.6) 450-CG-002 1-3/4" (44.5) TYP. 3 HEAD 400-004 400-011 4 INTERMEDIATE HORIZONTAL 400-044 400-007 4" (101.6) TYP. 4-1/2" (114.3) 400-004 400-CG-002 400-004 5 SILL kawneer.com 400-004 400-003 400-028 400-003 400-CG-002 5 SILL 400-003 400-004 400-028 © Kawneer Company, Inc., 2010 2 1 1-3/4" (44.5) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SCALE 3" = 1'-0" Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 7 5 LIGHTWEIGHT SILL 400-044 400-008 TRIFAB® 400 8 OCTOBER, 2010 BASIC FRAMING MEMBERS EC 97911-22 SCALE 3" = 1'-0" INSIDE GLAZING MEMBERS SCREW SPLINE SYSTEM CAD DETAILS = Trifab_400_pg04.dwg SHEAR BLOCK SYSTEM STICK SYSTEM CAD DETAILS = Trifab_400_pg05.dwg CAD DETAILS = Trifab_400_pg06.dwg 400-044 HEAD 400-003 400-004 400-003 400-011 400-004 400-008 400-004 450-CG-002 400-011 INTERMEDIATE HORIZONTAL 400-004 400-003 400-004 400-001 400-004 400-007 400-012 SILL 400-028 400-044 400-028 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB 400 CAN BE INSTALLED FOR INSIDE GLAZING SIMPLY BY REVERSING THE SYSTEM SUCH THAT THE REMOVABLE GLASS STOPS ARE LOCATED AT THE HEAD AND ON THE INTERIOR SIDE. ALTERNATE MULLION & SIDELITE BASE MEMBERS 450-CG-002 400-010 400-540 HEAVY TUBE MULLION HEAVY SCREW SPLINE MULLION EXPANSION TUBE MULLION 2" (51.0) * SIDELITE BASES SHOWN FOR USE WITH SCREW SPLINE & SHEAR BLOCK SYSTEMS ONLY. CAD DETAILS = Trifab_400_pg09.dwg 450-030 *SIDELITE BASE 450-030 450-028 450-031 *SIDELITE BASE 450-029 8-3/16" Max. (208.0) 4-5/16" Min. (109.5) 450-109 5-9/16" Max. (141.3) 400-026 400-028 4-1/2" (114.3) 400-004 6-15/16" Min. (176.2) 2" (51.0) 4" (101.6) 450-031 *SIDELITE BASE kawneer.com © Kawneer Company, Inc., 2010 400-013 400-014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. CAD DETAILS = Trifab_400_pg01.dwg THRU pg06. TRIFAB® 400 OCTOBER, 2010 EC 97911-22 9 ENTRANCE FRAMING SCALE 3" = 1'-0" CAD DETAILS = Trifab_400_pg10.dwg (Offset Pivot/Butt Hung) CAD DETAILS = Trifab_400_pg11.dwg (Center Hung) NOTE: OTHER TYPES OF KAWNEER DOORS MAY BE USED WITH THIS FRAMING SYSTEM. SEE ENTRANCE DETAILS FOR ADDITIONAL INFORMATION. 1 4 5 450-033 10 450-033 2 6 8 7 9 400-501 or 400-019 4 3 400-501 or 400-019 TRANSOM AREA 5 Transom area for both double and single acting doors with glass surround. Jambs above transom bar are routed out to accept glass holding Insert 450-033 with or without steel reinforcing. (400-110 Steel Reinforcing shown dashed) 3 ELEVATIONS ARE NUMBER KEYED TO DETAILS 400-501 400-501 4" (101.6) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® 400 FRAMING INCORPORATING KAWNEER "190" DOORS. 1-3/4" (44.5) TYP. 400-012 1-3/4" (44.5) TYP. 4" (101.6) TYP. 6 450-022 STOPS 450-022 STOPS 2 2 400-502 7 SINGLE ACTING DOOR 400-019 400-019 400-081 450-500 TRAY 8 © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 10 9 DOUBLE ACTING DOOR 400-502 10 400-081 450-500 TRAY 3 3 OPTIONAL SWEEP 69-139 SINGLE ACTING DOOR WITH TRANSOM kawneer.com 69-143 DOUBLE ACTING DOOR WITH TRANSOM SINGLE ACTING DOOR WITHOUT TRANSOM DOUBLE ACTING DOOR WITHOUT TRANSOM TRIFAB® 400 10 OCTOBER, 2010 ENTRANCE FRAMING (Open Back) EC 97911-22 SCALE 3" = 1'-0" CAD DETAILS = Trifab_400_pg12.dwg (Offset Pivot/Butt Hung) CAD DETAILS = Trifab_400_pg13.dwg (Center Hung) OPEN BACK FRAMING INCORPORATING KAWNEER "190" DOORS 5 10 450-CG-002 4 2 6 8 7 450-033 450-033 9 400-064 or 400-599 3 3 NOTE: Sidelite mullions must be orientated to provide at least one (1) deep vertical pocket per lite to facilitate glazing. 450-CG-002 Flat Filler 450-126 (3" Long) used at perimeter fastener locations or Pocket Filler 450-CG-002, 450-CG-028 for sidelites. 450-500 TRAY 450-126 8 10 OPTIONAL SWEEP 69-139 SINGLE ACTING DOOR WITH TRANSOM 400-064 400-064 400-081 450-126 2 400-502 7 DOUBLE ACTING DOOR 400-502 10 9 400-081 450-500 TRAY 3 69-143 DOUBLE ACTING DOOR WITH TRANSOM SINGLE ACTING DOOR WITHOUT TRANSOM DOUBLE ACTING DOOR WITHOUT TRANSOM kawneer.com © Kawneer Company, Inc., 2010 450-022 STOPS SINGLE ACTING DOOR Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 6 450-022 STOPS 3 400-599 400-599 4" (101.6) TYP. 2 5 TRANSOM AREA 1-3/4" (44.5) TYP. 400-001 400-064 or 400-599 4 ELEVATIONS ARE NUMBER KEYED TO DETAILS 1 450-CG-028 Transom area for both double and single acting doors with glass surround. Jambs above transom bar are routed out to accept glass holding Insert 450-033 with or without steel reinforcing. (400-110 Steel Reinforcing shown dashed) 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OTHER TYPES OF KAWNEER DOORS MAY BE USED WITH THIS FRAMING SYSTEM. SEE ENTRANCE DETAILS FOR ADDITIONAL INFORMATION. 450-CG-028 NOTE: TRIFAB® 400 OCTOBER, 2010 EC 97911-22 MISCELLANEOUS FRAMING SCALE 3" = 1'-0" 450-CG-028 450-CG-028 400-075 BRAKE METAL FILLER THREE POCKET CORNER -02 8 TWO POCKET CORNER 7 -CG 8 -CG -02 -010 -02 8 450 0 -01 -CG 8 450 400 400 FOUR POCKET CORNER -02 -CG -02 400 400-075 450 ONE POCKET CORNER 400-071 400-541 400-541 027 - 400 ADJUSTABLE BRAKE METAL CORNER 135° INSIDE CORNER STOOL TRIM CLIP BRAKE METAL FILLER 451-VG-150 BRAKE METAL ADAPTOR (Vertically/Horizontally) 400-520 450-087 061-223 PERIMETER FILLER kawneer.com STOOL TRIM 450-VG-140 HEAVYWEIGHT HEAD and SILL RECEPTOR (Stick Assembly) 450-026 451-VG-150 400-542 HEAD and JAMB COMPENSATING RECEPTOR (Screw Spline or Shear Block Assembly) 400-006 155° to 180° PIVOT MULLION 135° OUTSIDE CORNER BRAKE METAL FILLER 451-VG-572 400-006 © Kawneer Company, Inc., 2010 450-CG-028 450-CG-028 450-026 450-026 450-026 400-075 400-075 450 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 450-CG-028 CAD DETAILS = Trifab_400_pg07.dwg CAD DETAILS = Trifab_400_pg09.dwg Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 11 SNAP-IN DOOR STOP SNAP-IN FLUSH POCKET FILLER 4" x 4" TUBE 061-200 1-3/4" x 4" TUBE 061-110 1-3/4" x 1-3/4" TUBE TRIFAB® 400 OCTOBER, 2010 GLASSvent EC 97911-22 TM SCALE 3" = 1'-0" CAD DETAILS = Trifab_400_pg08.dwg OUTSWING CASEMENT VERTICAL SECTION 400-004 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. PROJECT-OUT VERTICAL SECTION 400-011 3 1 400-001 5 6 2 3 7 8 400-004 400-001 4 ELEVATION IS NUMBER KEYED TO DETAILS 2 4 400-011 OUTSWING CASEMENT VERTICAL SECTION 400-005 400-005 400-005 400-005 5 6 7 8 MAXIMUM / MINIMUM SIZES (1/4" INFILL) PROJECT-OUT MAXIMUM 60" x 36" MINIMUM 12" x 12" OUTSWING CASEMENT MAXIMUM 36" x 60" MINIMUM 12" x 12" kawneer.com © Kawneer Company, Inc., 2010 PROJECT-OUT VERTICAL SECTION Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 12 TRIFAB® 400 OCTOBER, 2010 EC 97911-22 GLASSventTM STOREFRONT GLASSvent™ HARDWARE SELECTION GUIDE PROJECT - OUT OUTSWING CASEMENT Stainless steel 4-bar hinge STANDARD STANDARD Cast white bronze cam lock STANDARD STANDARD Cast white bronze cam lock with pole ring OPTIONAL OPTIONAL Cast white bronze custodial lock with removable handle OPTIONAL OPTIONAL Cast white bronze concealed lock with removable hex key OPTIONAL OPTIONAL Cast white bronze pole/pull ring OPTIONAL Pivot-shoe roto-operator OPTIONAL Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DESCRIPTION Multi-point lock with cast white bronze locking handle Insect screen CAM LOCK REMOVABLE HANDLE OPTIONAL CAM LOCK WITH POLE RING PULL RING ROTO-OPERATOR OPTIONAL CUSTODIAL LOCK STAINLESS STEEL 4 BAR HINGES © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. OPTIONAL CONCEALED LOCK kawneer.com INSECT SCREEN WITH STANDARD WICKET INSECT SCREEN WITH FULL WICKET 13 14 TRIFAB® 400 OCTOBER, 2010 WINDLOAD CHARTS EC 97911-22 NOTE: If the end reaction of the mullion spacing (ft.) times mullion height (ft.) times specified windload (P.S.F.), divided by two is more than 500 lbs., the optional heavyweight head/sill receptor 400-006 must be used. 1 1.5 WITHOUT HORIZONTALS E = 40 PSF (1920 Pa) WIDTH IN METERS WIDTH IN METERS 2 1 15 14 3 9 A 2.5 8 7 B C D 6 E 5 2 2 3 4 5 6 7 10 3 A B 2.5 C D E 2 9 8 6 5 4 8 1.5 1 2 3 4 5 6 7 8 WIDTH IN FEET WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN METERS 1 1.5 1 2 1.5 2 15 15 14 4 3.5 11 A 10 B3 C D 9 8 E 7 2.5 2 6 5 1.5 1 2 3 4 5 6 WIDTH IN FEET 7 8 4 13 400-001 450-CG-002 IA = 2.291 (95.36. X 104) SE = 1.145 (18.76 X 103) HEIGHT IN FEET 12 HEIGHT IN METERS 13 12 3.5 B C3 D 10 9 E 8 7 2.5 2 6 5 4 400-110 STEEL A 11 HEIGHT IN METERS 14 HEIGHT IN FEET 3.5 11 7 I = 2.291 (95.36. X 104) SE = 1.145 (18.76 X 103) 1.5 1 400-001 450-CG-002 12 HEIGHT IN METERS 10 HEIGHT IN FEET 3.5 11 4 13 HEIGHT IN METERS HEIGHT IN FEET 12 4 2 14 4 13 4 1.5 15 1.5 1 2 3 4 5 6 7 8 WIDTH IN FEET Is = 0.970 (40.37 X 104) Ss = 0.535 (8.77 X 103) kawneer.com © Kawneer Company, Inc., 2010 WITH HORIZONTALS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. A = 15 PSF (720 Pa) B = 20 PSF (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L\175 up to 13'-6" and L\240 + 1/4" above 13'-6". These curves are for mullions WITH and WITHOUT HORIZONTALS and are based on precise engineering calculations for stress and deflection. Allowable windload stress for ALUMINUM 15,152 P.S.I. (104 MPa). STEEL 30,000 P.S.I. (206 MPa). Charted curves, in all cases, are for the limiting value. For special situations not covered by these curves, contact your Kawneer representative for additional information. TRIFAB® 400 EC 97911-22 WINDLOAD CHARTS A = 15 PSF (720 Pa) B = 20 PSF (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) E = 40 PSF (1920 Pa) WITH HORIZONTALS 1 1.5 WIDTH IN METERS 2 1 15 3 9 6 2.5 A B C2 D 5 1.5 8 E 1 2 3 4 5 6 7 400-005 10 3 9 A B 2.5 C D E2 8 7 IA = 1.882 (78.33 X 104) SA = 0.941 (15.42 X 103) 6 5 4 8 1.5 1 2 3 4 5 6 7 8 WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN METERS 1.5 2 1 15 1.5 2 15 14 14 A 10 3 B C D 2.5 9 8 E 7 2 6 5 1.5 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN FEET 3.5 11 4 13 HEIGHT IN METERS 12 400-005 IA = 1.882 (78.33 X 104) SA = 0.941 (15.42 X 103) 400-110 STEEL Is = 0.970 (40.37 X 104) Ss = 0.535 (8.77 X 103) 12 A 11 B 10 C D E 9 8 7 3 2.5 2 6 5 4 3.5 1.5 1 2 3 4 5 6 7 WIDTH IN FEET 8 HEIGHT IN METERS 4 13 HEIGHT IN FEET 3.5 11 WIDTH IN FEET 1 © Kawneer Company, Inc., 2010 12 HEIGHT IN METERS 10 HEIGHT IN FEET 3.5 11 4 13 HEIGHT IN METERS 12 7 kawneer.com 2 14 4 13 4 1.5 15 14 4 15 WITHOUT HORIZONTALS WIDTH IN METERS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. OCTOBER, 2010 WINDLOAD CHARTS EC 97911-22 A = 15 PSF (720 Pa) B = 20 PSF (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) E = 40 PSF (1920 Pa) WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS 1 1.5 WIDTH IN METERS 1 2 10 3 9 A 2.5 B C D 2 E 8 7 6 5 2 3 4 5 6 7 3.5 11 10 3 A B C 2.5 D E 2 9 8 6 5 4 8 1.5 1 2 3 4 5 6 7 8 WIDTH IN FEET WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN METERS 1 1.5 2 1 15 1.5 2 15 14 14 10 A 9 3 B 2.5 C D E 2 8 7 6 5 1.5 1 2 3 4 5 6 WIDTH IN FEET 7 8 400-013 450-CG-002 I = 3.432 (142.85 X 104) SE = 1.716 (28.12 X 103) HEIGHT IN FEET 3.5 11 4 13 HEIGHT IN METERS 12 12 3.5 11 A 3 B C D 2.5 E 10 9 8 7 2 6 5 4 HEIGHT IN METERS 4 13 HEIGHT IN FEET 12 7 I = 2.791 (116.17 X 104) S = 1.395 (22.86 X 103) 1.5 1 400-010 400-540 HEIGHT IN FEET 3.5 11 HEIGHT IN METERS HEIGHT IN FEET 12 4 13 HEIGHT IN METERS 4 13 4 2 14 14 4 1.5 15 15 1.5 1 2 3 4 5 6 7 8 WIDTH IN FEET kawneer.com © Kawneer Company, Inc., 2010 OCTOBER, 2010 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® 400 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 16 © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® 400 EC 97911-22 WINDLOAD CHARTS 4 kawneer.com 1 2 3 1.5 9 8 7 6 WIDTH IN FEET 4 5 6 7 A = 15 PSF (720 Pa) B = 20 PSF (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) E = 40 PSF (1920 Pa) WIDTH IN METERS 2 15 1 14 13 4 12 11 3.5 10 A 5 8 3 B 2.5 C D E2 1.5 400-014 I = 3.212 (133.69 X 104) S = 1.606 (26.32 X 103) 4 1 2 3 1.5 13 12 11 3.5 10 9 8 A 3 B C D 2.5 7 E 6 2 5 1.5 WIDTH IN FEET 4 5 6 7 8 HEIGHT IN METERS WITH HORIZONTALS HEIGHT IN FEET 1 HEIGHT IN METERS OCTOBER, 2010 17 WITHOUT HORIZONTALS WIDTH IN METERS 15 2 14 4 TRIFAB® 400 OCTOBER, 2010 EC 97911-22 WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS 1 1.5 WIDTH IN METERS 2 1 15 14 3 9 6 2.5 A B C2 D E 5 1.5 8 7 1 2 3 4 5 6 7 400-501 3.5 11 10 3 9 A B 2.5 C D E 2 8 7 400-019 6 I = 2.093 (87.12 X 104) S = 1.044 (17.11 X 103) 5 4 8 1.5 1 2 3 4 5 6 7 8 WIDTH IN FEET WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN METERS 1 1.5 2 1 15 1.5 2 15 14 14 A 10 B3 C D 9 8 E 7 2.5 2 6 5 1.5 1 2 3 4 5 6 7 WIDTH IN FEET 8 HEIGHT IN FEET 3.5 11 HEIGHT IN METERS 12 4 13 400-501 400-019 I = 2.093 (87.12 X 104) S = 1.044 (17.11 X 103) 400-110 STEEL Is = 0.970 (40.37 X 104) Ss = 0.535 (8.77 X 103) 12 3.5 A B C3 D E 2.5 11 10 9 8 7 2 6 5 4 HEIGHT IN METERS 4 13 HEIGHT IN FEET 12 HEIGHT IN METERS 10 HEIGHT IN FEET 3.5 11 4 13 HEIGHT IN METERS HEIGHT IN FEET 12 4 2 14 4 13 4 1.5 15 1.5 1 2 3 4 5 6 7 8 WIDTH IN FEET kawneer.com © Kawneer Company, Inc., 2010 A = 15 PSF (720 Pa) B = 20 PSF (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) E = 40 PSF (1920 Pa) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WINDLOAD CHARTS (Entrance Framing) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 18 TRIFAB® 400 OCTOBER, 2010 WINDLOAD CHARTS (Open Back Entrance) A = 15 PSF (720 Pa) B = 20 PSF (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) E = 40 PSF (1920 Pa) WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS 1 1.5 WIDTH IN METERS 2 1 15 3 9 6 A 2.5 B C D 2 E 5 1.5 8 7 1 2 3 4 5 6 7 400-599 450-CG-002 400-064 450-CG-002 10 3 A B C 2.5 D E 2 9 8 7 6 I = 2.105 (87.62 X 104) S = 1.043 (17.09 X 103) 5 4 8 1.5 1 2 3 4 5 6 7 8 WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN METERS 1.5 1 2 1.5 2 15 15 3.5 11 A 10 B 3 C D 2.5 E 9 8 7 2 6 400-599 450-CG-002 400-064 450-CG-002 I = 2.105 (87.62 X 10 ) S = 1.043 (17.09 X 103) 4 5 1.5 1 2 3 4 5 6 7 WIDTH IN FEET 8 400-110 STEEL Is = 0.970 (40.37 X 104) Ss = 0.535 (8.77 X 103) HEIGHT IN FEET 12 HEIGHT IN METERS 4 13 13 4 12 A 3.5 B C3 D E 2.5 11 10 9 8 7 2 6 5 4 1.5 1 2 3 4 5 6 7 WIDTH IN FEET 8 HEIGHT IN METERS 14 14 HEIGHT IN FEET 3.5 11 WIDTH IN FEET 1 kawneer.com 12 HEIGHT IN METERS 10 HEIGHT IN FEET 3.5 11 4 13 HEIGHT IN METERS HEIGHT IN FEET 12 4 2 14 4 13 4 1.5 15 14 © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-22 19 20 TRIFAB® 400 OCTOBER, 2010 DEADLOAD CHARTS EC 97911-22 A = (1/4 POINT LOADING) B = (1/6 POINT LOADING) C = (1/8 POINT LOADING) WIDTH IN METERS 1 1.5 WIDTH IN METERS 2 1 11 10 3 2 6 5 1.5 4 1 3 2 C .5 B A 1 1 2 3 4 5 6 7 HEIGHT IN METERS 7 400-004 STOP 400-004 STOP 2.5 8 450-CG-002 FILLER 400-003 TWO PIECE HORIZONTAL 400-011 TUBE HORIZONTAL 3 9 2.5 8 HEIGHT IN FEET 9 HEIGHT IN FEET 2 7 2 6 5 1.5 4 3 C B 2 A 1 0 8 2 1 WIDTH IN FEET 3 4 5 6 7 1 HEIGHT IN METERS 10 0 1.5 11 .5 8 WIDTH IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Horizontal or deadload limitations are based upon 1/8" (3.2) maximum allowable deflection at the center of an intermediate horizontal member. The accompanying chart is calculated for 1/4" (6.4) thick glass supported on two setting blocks placed at the loading points shown. DEADLOADS ON ENTRANCE TRANSOM BARS WIDTH IN METERS 1 1.5 WIDTH IN METERS 2 1 11 10 3 9 5 B 4 A 3 2 2 1.5 1 .5 1 1 2 3 4 5 6 WIDTH IN FEET 7 8 450-500 TRAY 400-502 SINGLE ACTING T-BAR 400-081 DOUBLE ACTING T-BAR HEIGHT IN FEET C 6 HEIGHT IN METERS 7 2.5 8 7 2 6 5 1.5 4 1 3 2 C .5 B A 1 0 1 2 3 4 5 6 7 HEIGHT IN METERS 2.5 8 HEIGHT IN FEET 2 10 3 9 0 1.5 11 8 WIDTH IN FEET kawneer.com © Kawneer Company, Inc., 2010 A = (1/4 POINT LOADING) B = (1/6 POINT LOADING) C = (1/8 POINT LOADING) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Height limitations for transom glass over a doorway are based on a 1/16" (1.6) maximum allowable deflection at the center of a transom bar. The accompanying chart is calculated for 1/4" (6.4) thick glass supported on two setting blocks placed at the loading points shown.