Literature

TRIFAB® 400
OCTOBER, 2010
FEATURES
Features
•
•
•
•
•
•
•
Trifab® 400 is 4" deep with a 1-3/4" sightline
Center plane glass applications
Flush glazed from either the inside or outside
Screw Spline, Shear Block or Stick fabrication
1/8", 1/4" or 3/8" infill options
Permanodic® anodized finishes in 7 choices
Painted finishes in standard and custom choices
Product Applications
•
•
•
•
Storefront, Ribbon Window or Punched Openings
Single-span
Integrated entrance framing allowing Kawneer standard entrances or other
specialty entrances to be incorporated
GLASSvent™ is easily incorporated
© Kawneer Company, Inc., 2010
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-22
For specific product applications,
Consult your Kawneer representative.
kawneer.com
1
kawneer.com
© Kawneer Company, Inc., 2010
BLANK PAGE
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
TRIFAB® 400
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
OCTOBER, 2010
EC 97911-22
TRIFAB® 400
OCTOBER, 2010
INDEX
PICTORIAL VIEWS............................................................................ 4-6
BASIC FRAMING MEMBERS........................................................... 7,8
ENTRANCE FRAMING.................................................................... 9,10
MISCELLANEOUS FRAMING............................................................ 11
GLASSventTM . .............................................................................. 12,13
WINDLOAD CHARTS.................................................................... 14-19
DEADLOAD CHARTS........................................................................ 20
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED
ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT
CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR
GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference.
Numbers in parentheses ( ) are millimeters unless otherwise noted.
The following metric (SI) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
© Kawneer Company, Inc., 2010
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-22
3
Kawneer reserves the right to change configurations without prior notice when deemed necessary
for product improvement.
kawneer.com
TRIFAB® 400
OCTOBER, 2010
PICTORIAL VIEW (SCREW SPLINE ASSEMBLY)
EC 97911-22
SCREW SPLINE MULLION
SPLINE SCREW
SNAP-IN FILLER
HEAD
INTERMEDIATE
HORIZONTAL
SNAP-IN FILLER
SILL
SILL
FLASHING
GLASS STOP
kawneer.com
© Kawneer Company, Inc., 2010
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
THE SPLIT VERTICAL IN THE SCREW SPLINE SYSTEM ALLOWS A FRAME
TO BE INSTALLED FROM UNITIZED ASSEMBLIES. SCREWS ARE DRIVEN
THROUGH THE BACK OF THE VERTICALS INTO SPLINES EXTRUDED IN
THE HORIZONTAL FRAMING MEMBERS. THE INDIVIDUAL UNITS ARE THEN
SNAPPED TOGETHER TO FORM A COMPLETED FRAME.
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
4
© Kawneer Company, Inc., 2010
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
OCTOBER, 2010
kawneer.com
TRIFAB® 400
EC 97911-22
PICTORIAL VIEW (SHEAR BLOCK ASSEMBLY)
THE SHEAR BLOCK SYSTEM OF FABRICATION ALLOWS A FRAME TO BE
PRE ASSEMBLED AND INSTALLED AS A SINGLE UNIT. HORIZONTALS ARE
ATTACHED TO THE VERTICALS WITH SHEAR BLOCKS.
MULLION
SHEAR BLOCK
AT HEAD
HEAD
INTERMEDIATE
HORIZONTAL
SHEAR BLOCK
AT HORIZONTAL/SILL
FLASHING
GLASS STOP
SILL
5
OCTOBER, 2010
PICTORIAL VIEW (STICK ASSEMBLY)
EC 97911-22
THE STICK SYSTEM OF FABRICATION ALLOWS ON-SITE
ASSEMBLY. HEAD AND SILL RECEPTORS ARE FASTENED
TO THE SURROUND. VERTICAL MULLIONS ARE THEN
INSTALLED IN THESE RECEPTORS AND ARE HELD IN
PLACE BY SNAP-IN INSERTS. INTERMEDIATE HORIZONTAL
MEMBERS ARE ATTACHED TO THE VERTICALS WITH SHEAR
BLOCKS. FLASHING IS NOT REQUIRED.
NOTE:
IF END REACTION OF THE MULLION
(MULLION SPACING (ft.) TIMES HEIGHT (ft.)
TIMES SPECIFIED WINDLOAD (psf)
DIVIDED BY TWO) IS MORE THAN 500 LBS.
THE OPTIONAL HEAVYWEIGHT HEAD/SILL
RECEPTOR 400-006 MUST BE USED.
(See Page 11 for details)
LIGHTWEIGHT
HEAD RECEPTOR
HEAD INSERT
TUBE MULLION
SHEAR BLOCK
AT HORIZONTAL
INTERMEDIATE
HORIZONTAL
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
TRIFAB® 400
SILL INSERT
LIGHTWEIGHT
SILL RECEPTOR
WEEP HOLES AT 1/4 POINTS
(Typical)
kawneer.com
© Kawneer Company, Inc., 2010
SNAP-IN FILLER
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
6
TRIFAB® 400
OCTOBER, 2010
EC 97911-22
BASIC FRAMING MEMBERS
3
4
5
ELEVATION IS NUMBER KEYED TO DETAILS
SCREW SPLINE SYSTEM
CAD DETAILS = Trifab_400_pg01.dwg
SHEAR BLOCK SYSTEM
STICK SYSTEM
CAD DETAILS = Trifab_400_pg02.dwg
CAD DETAILS = Trifab_400_pg03.dwg
1-3/4"
(44.5)
TYP.
1-3/4"
(44.5)
TYP.
400-005
1
VERTICAL
MULLION
2
JAMB
1
VERTICAL
MULLION
3
HEAD
400-012
2
JAMB
4"
(101.6)
TYP.
4"
(101.6)
TYP.
4
INTERMEDIATE
HORIZONTAL
400-004
400-003
4
INTERMEDIATE
HORIZONTAL
400-012
1
VERTICAL
MULLION
2
JAMB
3
LIGHTWEIGHT
HEAD
400-012
400-001
400-005
2"
(50.8)
400-001
1-3/4"
(44.5)
TYP.
400-001
4"
(101.6)
4"
(101.6)
4"
(101.6)
450-CG-002
1-3/4"
(44.5)
TYP.
3
HEAD
400-004
400-011
4
INTERMEDIATE
HORIZONTAL
400-044
400-007
4"
(101.6) TYP.
4-1/2"
(114.3)
400-004
400-CG-002
400-004
5
SILL
kawneer.com
400-004
400-003
400-028
400-003
400-CG-002
5
SILL
400-003
400-004
400-028
© Kawneer Company, Inc., 2010
2
1
1-3/4"
(44.5)
TYP.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
SCALE 3" = 1'-0"
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
7
5
LIGHTWEIGHT
SILL
400-044
400-008
TRIFAB® 400
8
OCTOBER, 2010
BASIC FRAMING MEMBERS
EC 97911-22
SCALE 3" = 1'-0"
INSIDE GLAZING MEMBERS
SCREW SPLINE SYSTEM
CAD DETAILS = Trifab_400_pg04.dwg
SHEAR BLOCK SYSTEM
STICK SYSTEM
CAD DETAILS = Trifab_400_pg05.dwg
CAD DETAILS = Trifab_400_pg06.dwg
400-044
HEAD
400-003
400-004
400-003
400-011
400-004
400-008
400-004
450-CG-002
400-011
INTERMEDIATE
HORIZONTAL
400-004
400-003
400-004
400-001
400-004
400-007
400-012
SILL
400-028
400-044
400-028
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
TRIFAB 400 CAN BE INSTALLED FOR INSIDE GLAZING SIMPLY BY REVERSING THE SYSTEM SUCH THAT THE REMOVABLE GLASS STOPS
ARE LOCATED AT THE HEAD AND ON THE INTERIOR SIDE.
ALTERNATE MULLION & SIDELITE BASE MEMBERS
450-CG-002
400-010
400-540
HEAVY
TUBE
MULLION
HEAVY
SCREW SPLINE
MULLION
EXPANSION
TUBE MULLION
2"
(51.0)
* SIDELITE BASES SHOWN FOR USE WITH SCREW SPLINE & SHEAR BLOCK SYSTEMS ONLY.
CAD DETAILS = Trifab_400_pg09.dwg
450-030
*SIDELITE BASE
450-030
450-028
450-031
*SIDELITE BASE
450-029
8-3/16" Max.
(208.0)
4-5/16" Min.
(109.5)
450-109
5-9/16" Max.
(141.3)
400-026
400-028
4-1/2"
(114.3)
400-004
6-15/16" Min.
(176.2)
2"
(51.0)
4"
(101.6)
450-031
*SIDELITE BASE
kawneer.com
© Kawneer Company, Inc., 2010
400-013
400-014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
CAD DETAILS = Trifab_400_pg01.dwg THRU pg06.
TRIFAB® 400
OCTOBER, 2010
EC 97911-22
9
ENTRANCE FRAMING
SCALE 3" = 1'-0"
CAD DETAILS = Trifab_400_pg10.dwg (Offset Pivot/Butt Hung)
CAD DETAILS = Trifab_400_pg11.dwg (Center Hung)
NOTE:
OTHER TYPES OF KAWNEER DOORS MAY BE USED WITH THIS FRAMING SYSTEM.
SEE ENTRANCE DETAILS FOR ADDITIONAL INFORMATION.
1
4
5
450-033
10
450-033
2
6
8
7
9
400-501
or
400-019
4
3
400-501
or
400-019
TRANSOM AREA
5
Transom area for both double and single acting doors with glass
surround. Jambs above transom bar are routed out to accept glass
holding Insert 450-033 with or without steel reinforcing.
(400-110 Steel Reinforcing shown dashed)
3
ELEVATIONS ARE NUMBER KEYED TO DETAILS
400-501
400-501
4"
(101.6)
TYP.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
TRIFAB® 400 FRAMING INCORPORATING KAWNEER "190" DOORS.
1-3/4"
(44.5)
TYP.
400-012
1-3/4"
(44.5)
TYP.
4"
(101.6)
TYP.
6
450-022
STOPS
450-022
STOPS
2
2
400-502
7
SINGLE ACTING DOOR
400-019
400-019
400-081
450-500
TRAY
8
© Kawneer Company, Inc., 2010
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
10
9
DOUBLE ACTING DOOR
400-502
10
400-081
450-500
TRAY
3
3
OPTIONAL
SWEEP
69-139
SINGLE ACTING DOOR
WITH TRANSOM
kawneer.com
69-143
DOUBLE ACTING DOOR
WITH TRANSOM
SINGLE ACTING DOOR
WITHOUT TRANSOM
DOUBLE ACTING DOOR
WITHOUT TRANSOM
TRIFAB® 400
10
OCTOBER, 2010
ENTRANCE FRAMING (Open Back)
EC 97911-22
SCALE 3" = 1'-0"
CAD DETAILS = Trifab_400_pg12.dwg (Offset Pivot/Butt Hung)
CAD DETAILS = Trifab_400_pg13.dwg (Center Hung)
OPEN BACK FRAMING INCORPORATING KAWNEER "190" DOORS
5
10
450-CG-002
4
2
6
8
7
450-033
450-033
9
400-064
or
400-599
3
3
NOTE: Sidelite mullions must be orientated to provide at least
one (1) deep vertical pocket per lite to facilitate glazing.
450-CG-002
Flat Filler 450-126 (3" Long) used at perimeter fastener locations
or Pocket Filler 450-CG-002, 450-CG-028 for sidelites.
450-500
TRAY
450-126
8
10
OPTIONAL
SWEEP
69-139
SINGLE ACTING DOOR
WITH TRANSOM
400-064
400-064
400-081
450-126
2
400-502
7
DOUBLE ACTING DOOR
400-502
10
9
400-081
450-500
TRAY
3
69-143
DOUBLE ACTING DOOR
WITH TRANSOM
SINGLE ACTING DOOR
WITHOUT TRANSOM
DOUBLE ACTING DOOR
WITHOUT TRANSOM
kawneer.com
© Kawneer Company, Inc., 2010
450-022
STOPS
SINGLE ACTING DOOR
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
6
450-022
STOPS
3
400-599
400-599
4"
(101.6)
TYP.
2
5
TRANSOM AREA
1-3/4"
(44.5)
TYP.
400-001
400-064
or
400-599
4
ELEVATIONS ARE NUMBER KEYED TO DETAILS
1
450-CG-028
Transom area for both double and single acting doors with glass
surround. Jambs above transom bar are routed out to accept glass
holding Insert 450-033 with or without steel reinforcing.
(400-110 Steel Reinforcing shown dashed)
1
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
OTHER TYPES OF KAWNEER DOORS MAY BE USED WITH THIS FRAMING SYSTEM.
SEE ENTRANCE DETAILS FOR ADDITIONAL INFORMATION.
450-CG-028
NOTE:
TRIFAB® 400
OCTOBER, 2010
EC 97911-22
MISCELLANEOUS FRAMING
SCALE 3" = 1'-0"
450-CG-028
450-CG-028
400-075
BRAKE METAL
FILLER
THREE POCKET CORNER
-02
8
TWO POCKET CORNER
7
-CG
8
-CG
-02
-010
-02
8
450
0
-01
-CG
8
450
400
400
FOUR POCKET CORNER
-02
-CG
-02
400
400-075
450
ONE POCKET CORNER
400-071
400-541
400-541
027
-
400
ADJUSTABLE
BRAKE METAL CORNER
135° INSIDE CORNER
STOOL TRIM CLIP
BRAKE METAL
FILLER
451-VG-150
BRAKE METAL ADAPTOR
(Vertically/Horizontally)
400-520
450-087
061-223
PERIMETER
FILLER
kawneer.com
STOOL TRIM
450-VG-140
HEAVYWEIGHT
HEAD and SILL RECEPTOR
(Stick Assembly)
450-026
451-VG-150
400-542
HEAD and JAMB
COMPENSATING
RECEPTOR
(Screw Spline or Shear
Block Assembly)
400-006
155° to 180°
PIVOT MULLION
135° OUTSIDE CORNER
BRAKE METAL
FILLER
451-VG-572
400-006
© Kawneer Company, Inc., 2010
450-CG-028
450-CG-028
450-026
450-026
450-026
400-075
400-075
450
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
450-CG-028
CAD DETAILS = Trifab_400_pg07.dwg
CAD DETAILS = Trifab_400_pg09.dwg
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
11
SNAP-IN
DOOR STOP
SNAP-IN
FLUSH POCKET
FILLER
4" x 4" TUBE
061-200
1-3/4" x 4"
TUBE
061-110
1-3/4" x 1-3/4"
TUBE
TRIFAB® 400
OCTOBER, 2010
GLASSvent
EC 97911-22
TM
SCALE 3" = 1'-0"
CAD DETAILS = Trifab_400_pg08.dwg
OUTSWING CASEMENT
VERTICAL SECTION
400-004
1
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
PROJECT-OUT
VERTICAL SECTION
400-011
3
1
400-001
5
6
2
3
7
8
400-004
400-001
4
ELEVATION IS NUMBER KEYED TO DETAILS
2
4
400-011
OUTSWING CASEMENT
VERTICAL SECTION
400-005
400-005
400-005
400-005
5
6
7
8
MAXIMUM / MINIMUM SIZES (1/4" INFILL)
PROJECT-OUT
MAXIMUM 60" x 36"
MINIMUM 12" x 12"
OUTSWING CASEMENT MAXIMUM 36" x 60"
MINIMUM 12" x 12"
kawneer.com
© Kawneer Company, Inc., 2010
PROJECT-OUT
VERTICAL SECTION
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
12
TRIFAB® 400
OCTOBER, 2010
EC 97911-22
GLASSventTM
STOREFRONT GLASSvent™ HARDWARE SELECTION GUIDE
PROJECT - OUT
OUTSWING CASEMENT
Stainless steel 4-bar hinge
STANDARD
STANDARD
Cast white bronze cam lock
STANDARD
STANDARD
Cast white bronze cam lock with pole ring
OPTIONAL
OPTIONAL
Cast white bronze custodial lock
with removable handle
OPTIONAL
OPTIONAL
Cast white bronze concealed lock
with removable hex key
OPTIONAL
OPTIONAL
Cast white bronze pole/pull ring
OPTIONAL
Pivot-shoe roto-operator
OPTIONAL
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DESCRIPTION
Multi-point lock with cast white
bronze locking handle
Insect screen
CAM LOCK
REMOVABLE
HANDLE
OPTIONAL
CAM LOCK
WITH POLE RING
PULL RING
ROTO-OPERATOR
OPTIONAL
CUSTODIAL
LOCK
STAINLESS STEEL
4 BAR HINGES
© Kawneer Company, Inc., 2010
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
OPTIONAL
CONCEALED LOCK
kawneer.com
INSECT SCREEN
WITH STANDARD WICKET
INSECT SCREEN
WITH FULL WICKET
13
14
TRIFAB® 400
OCTOBER, 2010
WINDLOAD CHARTS
EC 97911-22
NOTE:
If the end reaction of the mullion spacing (ft.) times mullion height (ft.) times specified windload (P.S.F.), divided by two is more than 500 lbs., the
optional heavyweight head/sill receptor 400-006 must be used.
1
1.5
WITHOUT HORIZONTALS
E = 40 PSF (1920 Pa)
WIDTH IN METERS
WIDTH IN METERS
2
1
15
14
3
9
A 2.5
8
7
B
C
D
6
E
5
2
2
3
4
5
6
7
10
3
A
B 2.5
C
D
E
2
9
8
6
5
4
8
1.5
1
2
3
4
5
6
7
8
WIDTH IN FEET
WIDTH IN FEET
WITH HORIZONTALS
WITHOUT HORIZONTALS
WIDTH IN METERS
WIDTH IN METERS
1
1.5
1
2
1.5
2
15
15
14
4
3.5
11
A
10
B3
C
D
9
8
E
7
2.5
2
6
5
1.5
1
2
3
4
5
6
WIDTH IN FEET
7
8
4
13
400-001
450-CG-002
IA = 2.291 (95.36. X 104)
SE = 1.145 (18.76 X 103)
HEIGHT IN FEET
12
HEIGHT IN METERS
13
12
3.5
B
C3
D
10
9
E
8
7
2.5
2
6
5
4
400-110 STEEL
A
11
HEIGHT IN METERS
14
HEIGHT IN FEET
3.5
11
7
I = 2.291 (95.36. X 104)
SE = 1.145 (18.76 X 103)
1.5
1
400-001
450-CG-002
12
HEIGHT IN METERS
10
HEIGHT IN FEET
3.5
11
4
13
HEIGHT IN METERS
HEIGHT IN FEET
12
4
2
14
4
13
4
1.5
15
1.5
1
2
3
4
5
6
7
8
WIDTH IN FEET
Is = 0.970 (40.37 X 104)
Ss = 0.535 (8.77 X 103)
kawneer.com
© Kawneer Company, Inc., 2010
WITH HORIZONTALS
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
A = 15 PSF (720 Pa)
B = 20 PSF (960 Pa)
C = 25 PSF (1200 Pa)
D = 30 PSF (1440 Pa)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L\175 up to 13'-6" and L\240 + 1/4" above 13'-6".
These curves are for mullions WITH and WITHOUT HORIZONTALS and are based on precise engineering calculations for stress and deflection.
Allowable windload stress for ALUMINUM 15,152 P.S.I. (104 MPa). STEEL 30,000 P.S.I. (206 MPa). Charted curves, in all cases, are for the limiting
value. For special situations not covered by these curves, contact your Kawneer representative for additional information.
TRIFAB® 400
EC 97911-22
WINDLOAD CHARTS
A = 15 PSF (720 Pa)
B = 20 PSF (960 Pa)
C = 25 PSF (1200 Pa)
D = 30 PSF (1440 Pa)
E = 40 PSF (1920 Pa)
WITH HORIZONTALS
1
1.5
WIDTH IN METERS
2
1
15
3
9
6
2.5
A
B
C2
D
5
1.5
8
E
1
2
3
4
5
6
7
400-005
10
3
9
A
B 2.5
C
D
E2
8
7
IA = 1.882 (78.33 X 104)
SA = 0.941 (15.42 X 103)
6
5
4
8
1.5
1
2
3
4
5
6
7
8
WIDTH IN FEET
WITH HORIZONTALS
WITHOUT HORIZONTALS
WIDTH IN METERS
WIDTH IN METERS
1.5
2
1
15
1.5
2
15
14
14
A
10
3
B
C
D 2.5
9
8
E
7
2
6
5
1.5
1
2
3
4
5
6
WIDTH IN FEET
7
8
HEIGHT IN FEET
3.5
11
4
13
HEIGHT IN METERS
12
400-005
IA = 1.882 (78.33 X 104)
SA = 0.941 (15.42 X 103)
400-110 STEEL
Is = 0.970 (40.37 X 104)
Ss = 0.535 (8.77 X 103)
12
A
11
B
10
C
D
E
9
8
7
3
2.5
2
6
5
4
3.5
1.5
1
2
3
4
5
6
7
WIDTH IN FEET
8
HEIGHT IN METERS
4
13
HEIGHT IN FEET
3.5
11
WIDTH IN FEET
1
© Kawneer Company, Inc., 2010
12
HEIGHT IN METERS
10
HEIGHT IN FEET
3.5
11
4
13
HEIGHT IN METERS
12
7
kawneer.com
2
14
4
13
4
1.5
15
14
4
15
WITHOUT HORIZONTALS
WIDTH IN METERS
HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
OCTOBER, 2010
WINDLOAD CHARTS
EC 97911-22
A = 15 PSF (720 Pa)
B = 20 PSF (960 Pa)
C = 25 PSF (1200 Pa)
D = 30 PSF (1440 Pa)
E = 40 PSF (1920 Pa)
WITH HORIZONTALS
WITHOUT HORIZONTALS
WIDTH IN METERS
1
1.5
WIDTH IN METERS
1
2
10
3
9
A
2.5
B
C
D
2
E
8
7
6
5
2
3
4
5
6
7
3.5
11
10
3
A
B
C 2.5
D
E
2
9
8
6
5
4
8
1.5
1
2
3
4
5
6
7
8
WIDTH IN FEET
WIDTH IN FEET
WITH HORIZONTALS
WITHOUT HORIZONTALS
WIDTH IN METERS
WIDTH IN METERS
1
1.5
2
1
15
1.5
2
15
14
14
10
A
9
3
B
2.5
C
D
E
2
8
7
6
5
1.5
1
2
3
4
5
6
WIDTH IN FEET
7
8
400-013
450-CG-002
I = 3.432 (142.85 X 104)
SE = 1.716 (28.12 X 103)
HEIGHT IN FEET
3.5
11
4
13
HEIGHT IN METERS
12
12
3.5
11
A
3
B
C
D 2.5
E
10
9
8
7
2
6
5
4
HEIGHT IN METERS
4
13
HEIGHT IN FEET
12
7
I = 2.791 (116.17 X 104)
S = 1.395 (22.86 X 103)
1.5
1
400-010
400-540
HEIGHT IN FEET
3.5
11
HEIGHT IN METERS
HEIGHT IN FEET
12
4
13
HEIGHT IN METERS
4
13
4
2
14
14
4
1.5
15
15
1.5
1
2
3
4
5
6
7
8
WIDTH IN FEET
kawneer.com
© Kawneer Company, Inc., 2010
OCTOBER, 2010
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
TRIFAB® 400
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
16
© Kawneer Company, Inc., 2010
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
TRIFAB® 400
EC 97911-22
WINDLOAD CHARTS
4
kawneer.com
1
2
3
1.5
9
8
7
6
WIDTH IN FEET
4
5
6
7
A = 15 PSF (720 Pa)
B = 20 PSF (960 Pa)
C = 25 PSF (1200 Pa)
D = 30 PSF (1440 Pa)
E = 40 PSF (1920 Pa)
WIDTH IN METERS
2
15
1
14
13
4
12
11
3.5
10
A
5
8
3
B 2.5
C
D
E2
1.5
400-014
I = 3.212 (133.69 X 104)
S = 1.606 (26.32 X 103)
4
1
2
3
1.5
13
12
11
3.5
10
9
8
A
3
B
C
D 2.5
7
E
6
2
5
1.5
WIDTH IN FEET
4
5
6
7
8
HEIGHT IN METERS
WITH HORIZONTALS
HEIGHT IN FEET
1
HEIGHT IN METERS
OCTOBER, 2010
17
WITHOUT HORIZONTALS
WIDTH IN METERS
15
2
14
4
TRIFAB® 400
OCTOBER, 2010
EC 97911-22
WITH HORIZONTALS
WITHOUT HORIZONTALS
WIDTH IN METERS
1
1.5
WIDTH IN METERS
2
1
15
14
3
9
6
2.5
A
B
C2
D
E
5
1.5
8
7
1
2
3
4
5
6
7
400-501
3.5
11
10
3
9
A
B 2.5
C
D
E
2
8
7
400-019
6
I = 2.093 (87.12 X 104)
S = 1.044 (17.11 X 103)
5
4
8
1.5
1
2
3
4
5
6
7
8
WIDTH IN FEET
WIDTH IN FEET
WITH HORIZONTALS
WITHOUT HORIZONTALS
WIDTH IN METERS
WIDTH IN METERS
1
1.5
2
1
15
1.5
2
15
14
14
A
10
B3
C
D
9
8
E
7
2.5
2
6
5
1.5
1
2
3
4
5
6
7
WIDTH IN FEET
8
HEIGHT IN FEET
3.5
11
HEIGHT IN METERS
12
4
13
400-501
400-019
I = 2.093 (87.12 X 104)
S = 1.044 (17.11 X 103)
400-110 STEEL
Is = 0.970 (40.37 X 104)
Ss = 0.535 (8.77 X 103)
12
3.5
A
B
C3
D
E
2.5
11
10
9
8
7
2
6
5
4
HEIGHT IN METERS
4
13
HEIGHT IN FEET
12
HEIGHT IN METERS
10
HEIGHT IN FEET
3.5
11
4
13
HEIGHT IN METERS
HEIGHT IN FEET
12
4
2
14
4
13
4
1.5
15
1.5
1
2
3
4
5
6
7
8
WIDTH IN FEET
kawneer.com
© Kawneer Company, Inc., 2010
A = 15 PSF (720 Pa)
B = 20 PSF (960 Pa)
C = 25 PSF (1200 Pa)
D = 30 PSF (1440 Pa)
E = 40 PSF (1920 Pa)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
WINDLOAD CHARTS (Entrance Framing)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
18
TRIFAB® 400
OCTOBER, 2010
WINDLOAD CHARTS (Open Back Entrance)
A = 15 PSF (720 Pa)
B = 20 PSF (960 Pa)
C = 25 PSF (1200 Pa)
D = 30 PSF (1440 Pa)
E = 40 PSF (1920 Pa)
WITH HORIZONTALS
WITHOUT HORIZONTALS
WIDTH IN METERS
1
1.5
WIDTH IN METERS
2
1
15
3
9
6
A
2.5
B
C
D
2
E
5
1.5
8
7
1
2
3
4
5
6
7
400-599
450-CG-002
400-064
450-CG-002
10
3
A
B
C 2.5
D
E
2
9
8
7
6
I = 2.105 (87.62 X 104)
S = 1.043 (17.09 X 103)
5
4
8
1.5
1
2
3
4
5
6
7
8
WIDTH IN FEET
WITH HORIZONTALS
WITHOUT HORIZONTALS
WIDTH IN METERS
WIDTH IN METERS
1.5
1
2
1.5
2
15
15
3.5
11
A
10
B
3
C
D
2.5
E
9
8
7
2
6
400-599
450-CG-002
400-064
450-CG-002
I = 2.105 (87.62 X 10 )
S = 1.043 (17.09 X 103)
4
5
1.5
1
2
3
4
5
6
7
WIDTH IN FEET
8
400-110 STEEL
Is = 0.970 (40.37 X 104)
Ss = 0.535 (8.77 X 103)
HEIGHT IN FEET
12
HEIGHT IN METERS
4
13
13
4
12
A
3.5
B
C3
D
E
2.5
11
10
9
8
7
2
6
5
4
1.5
1
2
3
4
5
6
7
WIDTH IN FEET
8
HEIGHT IN METERS
14
14
HEIGHT IN FEET
3.5
11
WIDTH IN FEET
1
kawneer.com
12
HEIGHT IN METERS
10
HEIGHT IN FEET
3.5
11
4
13
HEIGHT IN METERS
HEIGHT IN FEET
12
4
2
14
4
13
4
1.5
15
14
© Kawneer Company, Inc., 2010
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-22
19
20
TRIFAB® 400
OCTOBER, 2010
DEADLOAD CHARTS
EC 97911-22
A = (1/4 POINT LOADING)
B = (1/6 POINT LOADING)
C = (1/8 POINT LOADING)
WIDTH IN METERS
1
1.5
WIDTH IN METERS
2
1
11
10
3
2
6
5
1.5
4
1
3
2
C .5
B
A
1
1
2
3
4
5
6
7
HEIGHT IN METERS
7
400-004
STOP
400-004
STOP
2.5
8
450-CG-002
FILLER
400-003
TWO PIECE
HORIZONTAL
400-011
TUBE
HORIZONTAL
3
9
2.5
8
HEIGHT IN FEET
9
HEIGHT IN FEET
2
7
2
6
5
1.5
4
3
C
B
2
A
1
0
8
2
1
WIDTH IN FEET
3
4
5
6
7
1
HEIGHT IN METERS
10
0
1.5
11
.5
8
WIDTH IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Horizontal or deadload limitations are based upon 1/8" (3.2) maximum allowable deflection at the center of an intermediate horizontal member.
The accompanying chart is calculated for 1/4" (6.4) thick glass supported on two setting blocks placed at the loading points shown.
DEADLOADS ON ENTRANCE TRANSOM BARS
WIDTH IN METERS
1
1.5
WIDTH IN METERS
2
1
11
10
3
9
5
B
4
A
3
2
2
1.5
1
.5
1
1
2
3
4
5
6
WIDTH IN FEET
7
8
450-500
TRAY
400-502
SINGLE ACTING
T-BAR
400-081
DOUBLE ACTING
T-BAR
HEIGHT IN FEET
C
6
HEIGHT IN METERS
7
2.5
8
7
2
6
5
1.5
4
1
3
2
C
.5
B
A
1
0
1
2
3
4
5
6
7
HEIGHT IN METERS
2.5
8
HEIGHT IN FEET
2
10
3
9
0
1.5
11
8
WIDTH IN FEET
kawneer.com
© Kawneer Company, Inc., 2010
A = (1/4 POINT LOADING)
B = (1/6 POINT LOADING)
C = (1/8 POINT LOADING)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Height limitations for transom glass over a doorway are based on a 1/16" (1.6) maximum allowable deflection at the center of a transom bar.
The accompanying chart is calculated for 1/4" (6.4) thick glass supported on two setting blocks placed at the loading points shown.