Trifab Trifab VG VG (VersaGlaze (VersaGlaze )) ® ® ® ® Trifab VG 450, 451 & 451T (Thermal) Framing Systems & Trifab®VG 450, 451 & 451T (Thermal) Framing Systems Trifab 451UT (Ultra Thermal) Framing System ® Design Design Versatility + Performance with Unmatched Versatility with Unmatched Fabrication Fabrication Flexibility Flexibility Preston Pointe, Louisville, KY Architect: Potter & Associates Architects PLLC, Louisville, KY Glazing Contractor: Kentucky Mirror & Plate Glass Company, Louisville, KY Trifab® VG (VersaGlaze®) is built on the proven and successful Trifab® platform – with all the versatility its name implies. There are enough framing system choices, fabrication methods, design options and performance levels to please the most discerning building owner, architect and installer. The Trifab® VG family’s newest addition, Trifab® 451UT (Ultra Thermal) framing system, is designed for the most demanding thermal performance and employs a “dual” Isolock® Thermal Break. Aesthetics Trifab® VG framing systems offer designers a choice of front-, center-, back- or multi-plane glass applications. Structural silicone glazing (SSG) and Weatherseal glazing options further expand the designers’ choices, allowing for a greater range of design possibilities for specific project requirements and architectural styles. All systems have a 4-1/2" frame depth – Trifab® VG 450 has 1-3/4" sightlines, while Trifab® VG 451/451T and Trifab® 451UT have 2" sightlines. With seamless incorporation of Kawneer entrances or windows, including GLASSvent® visually frameless ventilators, Trifab® VG can be used on almost any project. These framing systems can also be packaged with Kawneer curtain walls and overhead glazing, thereby providing a full range of proven, and tested, quality products for the owner, architect and installer from a single source supplier. Performance Kawneer’s Isolock® Thermal Break process creates a composite section, prevents dry shrinkage and is available on Trifab® VG 451T. For even greater thermal performance, a “dual” Isolock® Thermal Break is used on Trifab® 451UT. Economy Trifab® VG 450, 451 and 451T framing systems offer four fabrication choices to suit your project (Trifab® 451UT available as screw spline fabrication only): • Screw Spline – for economical continuous runs utilizing two piece vertical members that provide the option to pre-assemble units with controlled shop labor costs and smaller field crews for handling and installation. • Shear Block – for punched openings or continuous runs using tubular moldings with shear block clips that provide tight joints for transporting large pre-assembled multi-lite units. • Stick – for fast, easy field fabrication. Field measurements and material cuts can be done when metal is on the job. • Type B – Same fabrication benefits as shear block except head and sill run through. All systems can be flush glazed from either the inside or outside. The Weatherseal option provides an alternative to SSG vertical mullions for Trifab® VG 450, 451 and 451T. This ABS/ASA rigid polymer extrusion allows complete inside glazing and creates a flush glass appearance on the building exterior without the added labor of scaffolding or swing stages. Additionally, High-Performance (HP) Flashing options are Brighton Landing, Cambridge, MA engineered to eliminate Architects: ADD Inc., Cambridge, MA perimeter sill fasteners and Glazing Contractors: Ipswich Bay associated blind seals. Glass Company, Inc., Rowley, MA Finishes Architectural Class I anodized aluminum finishes are available in clear and Permanodic® color choices. Painted finishes, including fluoropolymer that meet or exceed AAMA 2605, are offered in many standard choices and an unlimited number of specially-designed colors. Trifab® 451UT uses a “dual” Isolock® Thermal Break (right) and features a new HP (High Performance) sill design, which incorporates a screwapplied end dam (left), ensuring positive engagement and tight joints between the sill flashing and end dam. U-factor, CRF values and STC ratings for Trifab® VG vary depending upon the glass plane application. Project specific U-factors can be determined for each individual project. (See the Kawneer Architectural Manual or Kawneer.com for additional information). Thermal simulations showing temperature variations from exterior/cold side to interior/warm side. Trifab® VG 451 Trifab® VG 451T Performance Test Standards Air Performance Water Structural Thermal Thermal Break Acoustical Trifab® 451UT ASTM E 283 AAMA 501 and ASTM E 331 ASTM E 330 AAMA 1503 AAMA 505 and AAMA TIR-A8 AAMA 1801 and ASTM E 1425 Trifab® VG 450, 451 and 451T glazing options (note: Trifab® 451UT available as center set glass plane only). Solvent-free powder coatings add the “green” element with high performance, durability and scratch resistance that meet the standards of AAMA 2604. Front Kawneer Company, Inc. Technology Park / Atlanta 555 Guthridge Court Norcross, GA 30092 © Kawneer Company, Inc. 2010 kawneer.com 770 . 449 . 5555 LITHO IN U.S.A. Form No. 07-2007-06.10 Center Back SSG Weatherseal Multi-Plane TRIFAB® VG 450 JANUARY, 2009 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-07 FEATURES Features s Trifab® VG 450 is 4-1/2" deep with a 1-3/4" sight line s Front, Center, Back or Multi-Plane glass applications s Flush glazed from either the inside or outside s Screw Spline, Shear Block, Stick or Type-B fabrication s SSG / Weatherseal option s 1/8", 1/4" or 3/8" infill options s Permanodic® anodized finishes in 7 choices s Painted finishes in standard and custom choices Optional Features s High performance interlocking flashing Product Applications specialty entrances to be incorporated s Kawneer Sealair® windows or GLASSvent™ are easily incorporated © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. s Storefront, Ribbon Window or Punched Openings s Single-span s Integrated entrance framing allowing Kawneer standard entrances or other For specific product applications, Consult your Kawneer representative. kawneer.com 1 kawneer.com © Kawneer Company, Inc., 2009 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® VG 450 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 JANUARY, 2009 EC 97911-07 TRIFAB® VG 450 JANUARY, 2009 INDEX PICTORIAL VIEWS ........................................................................................ 5-9 CENTER ......................................................................................................... 11 FRONT ........................................................................................................... 23 BACK ............................................................................................................... 39 MULTI-PLANE ................................................................................................. 47 CHARTS (WINDLOAD, DEADLOAD, END REACTION & THERMAL) ..................... 55-73 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-07 3 The following metric (SI) units are found in these details: m – meter cm – centimeter mm – millimeter s – second Pa – pascal MPa – megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com kawneer.com © Kawneer Company, Inc., 2009 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® VG 450 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 JANUARY, 2009 EC 97911-07 TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 5 PICTORIAL VIEW (CENTER) THE SHEAR BLOCK SYSTEM OF FABRICATION ALLOWS A FRAME TO BE PRE-ASSEMBLED AND INSTALLED AS A SINGLE UNIT. HORIZONTALS ARE ATTACHED TO THE VERTICALS WITH SHEAR BLOCKS. SCREW SPLINE ASSEMBLY SHEAR BLOCK ASSEMBLY Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. THE SPLIT VERTICAL IN THE SCREW SPLINE SYSTEM ALLOWS A FRAME TO BE INSTALLED FROM UNITIZED ASSEMBLIES. SCREWS ARE DRIVEN THROUGH THE BACK OF THE VERTICALS INTO SPLINES EXTRUDED IN THE HORIZONTAL FRAMING MEMBERS. THE INDIVIDUAL UNITS ARE THEN SNAPPED TOGETHER TO FORM A COMPLETED FRAME. MULLION MULLION SNAP-IN FILLER SHEAR BLOCK SPLINE SCREWS HEAD HEAD GLASS STOP GLASS STOP SHEAR BLOCK HORIZONTAL HORIZONTAL GLASS STOP GLASS STOP SILL SILL SILL FLASHING SILL FLASHING STICK ASSEMBLY THE STICK SYSTEM ALLOWS ON-SITE ASSEMBLY. HEAD AND SILL RECEPTORS ARE FASTENED TO THE SURROUND. VERTICAL MULLIONS ARE THEN INSTALLED IN THESE RECEPTORS AND ARE HELD IN PLACE BY SNAP-IN INSERTS. INTERMEDIATE HORIZONTAL MEMBERS ARE ATTACHED TO THE VERTICALS WITH SHEAR BLOCKS. FLASHING IS NOT REQUIRED. HEAD RECEPTOR MULLION HEAD INSERT GLASS STOP © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SHEAR BLOCK SHEAR BLOCK HORIZONTAL NOTE: If the end reaction of the mullion (mullion spacing (ft.) times height (ft.) times specified windload (psf) divided by two) is more than 500 lbs., the optional mullion anchors must be used. (See page 14) GLASS STOP SILL INSERT SILL RECEPTOR kawneer.com TRIFAB® VG 450 JANUARY, 2009 PICTORIAL VIEW (FRONT) EC 97911-07 THE SPLIT VERTICAL IN THE SCREW SPLINE SYSTEM ALLOWS A FRAME TO BE INSTALLED FROM UNITIZED ASSEMBLIES. SCREWS ARE DRIVEN THROUGH THE BACK OF THE VERTICALS INTO SPLINES EXTRUDED IN THE HORIZONTAL FRAMING MEMBERS. THE INDIVIDUAL UNITS ARE THEN SNAPPED TOGETHER TO FORM A COMPLETED FRAME. THE SHEAR BLOCK SYSTEM OF FABRICATION ALLOWS A FRAME TO BE PRE-ASSEMBLED AND INSTALLED AS A SINGLE UNIT. HORIZONTALS ARE ATTACHED TO THE VERTICALS WITH SHEAR BLOCKS. SCREW SPLINE ASSEMBLY SHEAR BLOCK ASSEMBLY MULLION SNAP-IN FILLER SPLINE SCREWS MULLION HEAD SHEAR BLOCK HEAD GLASS STOP GLASS STOP SHEAR BLOCK HORIZONTAL HORIZONTAL Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 6 FLAT FILLER FLAT FILLER GLASS STOP GLASS STOP SILL SILL SILL FLASHING SHEAR BLOCK STICK ASSEMBLY HEAD RECEPTOR HEAD INSERT GLASS STOP SHEAR BLOCK MULLION NOTE: If the end reaction of the mullion (mullion spacing (ft.) times height (ft.) times specified windload (psf) divided by two) is more than 500 lbs., the optional mullion anchors must be used. (See page 32) HORIZONTAL GLASS STOP SILL INSERT SILL RECEPTOR kawneer.com © Kawneer Company, Inc., 2009 THE STICK SYSTEM ALLOWS ON-SITE ASSEMBLY. HEAD AND SILL RECEPTORS ARE FASTENED TO THE SURROUND. VERTICAL MULLIONS ARE THEN INSTALLED IN THESE RECEPTORS AND ARE HELD IN PLACE BY SNAP-IN INSERTS. INTERMEDIATE HORIZONTAL MEMBERS ARE ATTACHED TO THE VERTICALS WITH SHEAR BLOCKS. FLASHING IS NOT REQUIRED. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SILL FLASHING JANUARY, 2009 TRIFAB® VG 450 EC 97911-07 PICTORIAL VIEW (FRONT) 7 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. THE STICK SYSTEM ALLOWS ON-SITE ASSEMBLY. HEAD AND SILL RECEPTORS ARE FASTENED TO THE SURROUND. VERTICAL MULLIONS ARE THEN INSTALLED IN THESE RECEPTORS AND ARE HELD IN PLACE BY SNAP-IN INSERTS. INTERMEDIATE HORIZONTAL MEMBERS ARE ATTACHED TO THE VERTICALS WITH SHEAR BLOCKS. FLASHING IS NOT REQUIRED. STICK ASSEMBLY (SSG) STICK ASSEMBLY (WEATHERSEAL) HEAD RECEPTOR HEAD RECEPTOR HEAD INSERT HEAD INSERT GLASS STOP GLASS STOP SHEAR BLOCK SHEAR BLOCK HORIZONTAL GLASS STOP SSG MULLION SSG MULLION GLASS STOP SILL INSERT NOTE: If the end reaction of the mullion (mullion spacing (ft.) times height (ft.) times specified windload (psf) divided by two) is more than 500 lbs., the optional mullion anchors must be used. (See page 32) © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SILL RECEPTOR kawneer.com HORIZONTAL WEATHERSEAL GLASS STOP GLASS STOP SILL INSERT SILL RECEPTOR 8 TRIFAB® VG 450 JANUARY, 2009 PICTORIAL VIEW (FRONT) EC 97911-07 TYPE-B ASSEMBLY PUNCHED OPENING (CAPTURED) TYPE-B ASSEMBLY PUNCHED OPENING (SSG) SPLINE SCREWS SPLINE SCREWS HEAD COPE HEAD HEAD GLASS STOP SSG MULLION GLASS STOP MULLION SHEAR BLOCK SHEAR BLOCK HORIZONTAL HORIZONTAL GLASS STOP GLASS STOP SSG COVER Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. THE PUNCHED OPENING FABRICATION ALLOWS A FRAME TO BE PRE-ASSEMBLED AND INSTALLED AS A SINGLE UNIT. SCREWS ARE DRIVEN THROUGH THE BACK OF THE HEAD AND SILL MEMBERS INTO SPLINES EXTRUDED IN THE VERTICAL FRAMING MEMBERS. INTERMEDIATE HORIZONTALS ARE ATTACHED TO THE VERTICALS WITH SHEAR BLOCKS. SILL SILL SPLINE SCREWS TYPE-B ASSEMBLY PUNCHED OPENING (WEATHERSEAL) SPLINE SCREWS WEATHERSEAL HEAD GLASS STOP SSG MULLION SHEAR BLOCK HORIZONTAL GLASS STOP SSG COVER SILL SPLINE SCREWS kawneer.com © Kawneer Company, Inc., 2009 THE PUNCHED OPENING FABRICATION ALLOWS A FRAME TO BE PRE-ASSEMBLED AND INSTALLED AS A SINGLE UNIT. SCREWS ARE DRIVEN THROUGH THE BACK OF THE HEAD AND SILL MEMBERS INTO SPLINES EXTRUDED IN THE VERTICAL FRAMING MEMBERS. INTERMEDIATE HORIZONTALS ARE ATTACHED TO THE VERTICALS WITH SHEAR BLOCKS. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SPLINE SCREWS TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 PICTORIAL VIEW (BACK) THE SHEAR BLOCK SYSTEM OF FABRICATION ALLOWS A FRAME TO BE PRE-ASSEMBLED AND INSTALLED AS A SINGLE UNIT. HORIZONTALS ARE ATTACHED TO THE VERTICALS WITH SHEAR BLOCKS. SCREW SPLINE ASSEMBLY SHEAR BLOCK ASSEMBLY Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. THE SPLIT VERTICAL IN THE SCREW SPLINE SYSTEM ALLOWS A FRAME TO BE INSTALLED FROM UNITIZED ASSEMBLIES. SCREWS ARE DRIVEN THROUGH THE BACK OF THE VERTICALS INTO SPLINES EXTRUDED IN THE HORIZONTAL FRAMING MEMBERS. THE INDIVIDUAL UNITS ARE THEN SNAPPED TOGETHER TO FORM A COMPLETED FRAME. MULLION MULLION SNAP-IN FILLER SPLINE SCREWS SHEAR BLOCK HEAD HEAD GLASS STOP GLASS STOP SHEAR BLOCK HORIZONTAL HORIZONTAL GLASS STOP GLASS STOP SILL SILL SILL FLASHING SILL FLASHING SHEAR BLOCK THE STICK SYSTEM ALLOWS ON-SITE ASSEMBLY. HEAD AND SILL RECEPTORS ARE FASTENED TO THE SURROUND. VERTICAL MULLIONS ARE THEN INSTALLED IN THESE RECEPTORS AND ARE HELD IN PLACE BY SNAP-IN INSERTS. INTERMEDIATE HORIZONTAL MEMBERS ARE ATTACHED TO THE VERTICALS WITH SHEAR BLOCKS. FLASHING IS NOT REQUIRED. STICK ASSEMBLY HEAD RECEPTOR MULLION HEAD INSERT GLASS STOP © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 9 SHEAR BLOCK HORIZONTAL NOTE: If the end reaction of the mullion (mullion spacing (ft.) times height (ft.) times specified windload (psf) divided by two) is more than 500 lbs., the optional mullion anchors must be used. (See page 43) GLASS STOP SILL INSERT SILL RECEPTOR kawneer.com kawneer.com © Kawneer Company, Inc., 2009 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® VG 450 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 10 JANUARY, 2009 EC 97911-07 JANUARY, 2009 EC 97911-07 TRIFAB® VG 450 11 INDEX (CENTER) MISCELLANEOUS FRAMING..................................................... 14,15 CORNERS......................................................................................... 16 CURVING & TRIM DETAILS ............................................................. 17 ENTRANCE FRAMING .................................................................... 18 ENTRANCE FRAMING (OPEN BACK) ............................................ 19 GLASSvent™ .............................................................................. 20,21 VENTS............................................................................................... 22 © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. BASIC FRAMING DETAILS......................................................... 12,13 kawneer.com TRIFAB® VG 450 12 JANUARY, 2009 BASIC FRAMING DETAILS (CENTER - Outside Glazed) EC 97911-07 SCALE 3" = 1'-0" 2 3 ELEVATION IS NUMBER KEYED TO DETAILS SCREW SPLINE CAD Details = TF_VG_450-SS-Center--CAD.zip 450-CG-001 450-CG-001 SHEAR BLOCK STICK CAD Details = TF_VG_450-SB-Center--CAD.zip CAD Details = TF_VG_450-Stick-Center--CAD.zip 1-3/4" (44.5) TYP. 450-CG-001 450-CG-001 450-CG-005 4 JAMB 5 VERTICAL 450-CG-005 4-1/2" (114.3) TYP. 450-CG-002 5 VERTICAL 1 HEAD 1 HEAD 1-3/4" (44.5) TYP. 1 HEAD 4 JAMB 450-CG-004 450-CG-004 450-CG-003 451-VG-006 2-1/4" (57.2) 5 VERTICAL 4 JAMB 450-CG-003 450-CG-004 450-CG-008 4-1/2" (114.3) TYP. 450-CG-002 2 HORIZONTAL 2 HORIZONTAL 2 HORIZONTAL 450-CG-004 450-CG-011 450-CG-004 450-CG-011 450-CG-004 450-CG-003 450-CG-007 450-CG-001 450-037 *See page 14 for Optional High Performance Flashing. 3 SILL 450-037 3 SILL 2-1/4" (57.2) 3 SILL 450-CG-001 451-VG-106 *See page 14 for Optional High Performance Flashing. kawneer.com © Kawneer Company, Inc., 2009 5 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 13 BASIC FRAMING DETAILS (CENTER - Inside Glazed) SCALE 3" = 1'-0" 4 2 3 ELEVATION IS NUMBER KEYED TO DETAILS SCREW SPLINE CAD Details = TF_VG_450-SS-Center--CAD.zip 450-CG-001 450-CG-001 SHEAR BLOCK STICK CAD Details = TF_VG_450-SB-Center--CAD.zip CAD Details = TF_VG_450-Stick-Center--CAD.zip 1-3/4" (44.5) TYP. 450-CG-001 450-CG-001 450-CG-005 4 JAMB 5 VERTICAL 450-CG-005 450-CG-002 1-3/4" (44.5) TYP. 1 HEAD 4 JAMB 5 VERTICAL 1 HEAD 1 HEAD 450-CG-003 450-CG-003 450-CG-004 451-VG-006 2-1/4" (57.2) 5 VERTICAL 4 JAMB 450-CG-004 450-CG-008 4-1/2" (114.3) TYP. 450-CG-004 450-CG-002 2 HORIZONTAL 2 HORIZONTAL 2 HORIZONTAL 450-CG-011 450-CG-004 450-CG-011 450-CG-003 450-CG-004 450-CG-004 450-CG-007 450-CG-001 3 SILL 450-037 *See page 14 for Optional High Performance Flashing. kawneer.com 450-CG-001 3 SILL 450-037 *See page 14 for Optional High Performance Flashing. 3 SILL 2-1/4" (57.2) © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5 4-1/2" (114.3) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 451-VG-106 14 TRIFAB® VG 450 JANUARY, 2009 MISCELLANEOUS FRAMING (CENTER) EC 97911-07 SCALE 3" = 1'-0" CAD Details SHEAR BLOCK = TF_VG_450-SB-Center--CAD.zip CAD Details STICK = TF_VG_450-Stick-Center--CAD.zip Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CAD Details SCREW SPLINE = TF_VG_450-SS-Center--CAD.zip 451-HP-126 CLIP 450-CG-540 450-CG-010 451-HP-037 HIGH PERFORMANCE FLASHING EXPANSION MULLION 450-026 450-520 450-087 450-110 STEEL REINFORCING SNAP-IN DOOR STOP STEEL REINFORCEMENT 450-VG-006 2" (50.8) 2" (50.8) 2" (50.8) 2" (50.8) 450-VG-006 450-CG-362 450-VG-106 MULLION ANCHOR NOTE: If the end reaction of the mullion (mullion spacing (ft.) times height (ft.) times specified windload (psf) divided by two) is more than 500 lbs., the optional Mullion Anchors must be used. OPTIONAL LIGHTWEIGHT CAN RECEPTORS (Stick System) 450-VG-006 OPTIONAL UNEQUAL LEG CAN RECEPTORS (Stick System) NOTE: Mullion Anchor not used with Lightweight Receptor. kawneer.com © Kawneer Company, Inc., 2009 SNAP-IN FLAT POCKET FILLER Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SNAP-IN FLAT FILLER TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 15 MISCELLANEOUS FRAMING (CENTER) SCALE 3" = 1'-0" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CAD Details SCREW SPLINE = TF_VG_450-SS-Center--CAD.zip CAD Details SHEAR BLOCK = TF_VG_450-SB-Center--CAD.zip CAD Details STICK = TF_VG_450-Stick-Center--CAD.zip 451-VG-570 2" (50.8) TYPICAL 451-VG-570 451-VG-573 451-VG-572 5-1/2" (139.7) TYPICAL 451-VG-374 CLIP HEAVY WEIGHT HEAD COMPENSATING RECEPTOR STANDARD HEAD COMPENSATING RECEPTOR 451-VG-571 451-VG-570 451-VG-572 JAMB COMPENSATING RECEPTOR 450-030 4-1/2" (114.3) 450-CG-004 450-CG-004 450-CG-004 450-029 450-027 4-1/2" (114.3) 450-028 450-CG-004 4-1/2" (114.3) 450-030 6-5/16" MIN. - 8-3/16" MAX. (160.3) (208) 4-5/16" MIN. - 5-9/16" MAX. (109.5) (141.3) 2" (50.8) © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. ONE PIECE HEAD COMPENSATING RECEPTOR 450-027 450-037 450-109 450-031 NARROW SIDELITE BASE 450-CG-002 450-031 NARROW SIDELITE BASE SIDELITE BASE 4-1/2" X 4-1/2" HORIZONTAL NOTE: SIDELITE BASES SHOWN ARE FOR USE WITH SCREW SPLINE AND SHEAR BLOCK SYSTEMS ONLY. kawneer.com 16 TRIFAB® VG 450 JANUARY, 2009 CORNERS (CENTER) EC 97911-07 SCALE 3" = 1'-0" CAD Details STICK = TF_VG_450-Stick-Center--CAD.zip 450-017 450-017 4-1/2" (114.3) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CAD Details SHEAR BLOCK = TF_VG_450-SB-Center--CAD.zip 450-017 4-1/2" (114.3) TYP. 4-1/2" x 4-1/2" TUBE 450-CG-015 TWO PIECE NO POCKET CORNER ONE POCKET CORNER 450-CG-016 450-CG-015 450-CG-035 450-CG-015 TWO POCKET 90o CORNER 450-CG-015 450-CG-015 TWO POCKET VERTICAL POST THREE POCKET 90o CORNER 451-CG-034 450-CG-016 450-CG-028 450-CG-028 450-CG-028 450-CG-028 450-CG-016 451-CG-034 FOUR POCKET 90o CORNER 450-CG-010 135o INSIDE CORNER 135o OUTSIDE CORNER 451-CG-071 451-CG-071 450-CG-010 450-CG-541 450-CG-541 BRAKE METAL FILLERS VARIABLE DEGREE BRAKE METAL CORNER 450-CG-541 155° TO 180° PIVOT MULLION (OUTSIDE CORNER) 450-CG-541 155° TO 180° PIVOT MULLION (INSIDE CORNER) kawneer.com © Kawneer Company, Inc., 2009 060-119 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. CAD Details SCREW SPLINE = TF_VG_450-SS-Center--CAD.zip JANUARY, 2009 TRIFAB® VG 450 EC 97911-07 CURVING & TRIM DETAILS SCALE 3" = 1'-0" 1 1 1-3/4" (44.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CAD Details SCREW SPLINE = TF_VG_450-SS-Center--CAD.zip 175-181 3 175-183 175-182 175-190 175-181 4-1/2" (114.3) 2 CURVING DETAILS (Center Plane Only) 2 175-190 3 175-191 CAD Details SCREW SPLINE = TF_VG_450-SS-Center--CAD.zip CAD Details SHEAR BLOCK = TF_VG_450-SB-Center--CAD.zip CAD Details STICK = TF_VG_450-Stick-Center--CAD.zip STOOL TRIM 450-VG-640 STOOL TRIM CLIP WITH STANDARD FLASHING BRAKE METAL FILLERS STOOL TRIM 451-VG-150 450-VG-640 BRAKE METAL ADAPTOR AT HORIZONTAL STOOL TRIM CLIP WITH HIGH PERFORMANCE FLASHING © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 451-VG-150 BRAKE METAL FILLERS STOOL TRIM 451-VG-150 451-VG-150 069-271 STOOL TRIM CLIP FOR STICK/TYPE-B ASSEMBLY kawneer.com BRAKE METAL ADAPTOR AT VERTICAL 17 TRIFAB® VG 450 18 JANUARY, 2009 ENTRANCE FRAMING (CENTER) EC 97911-07 SCALE 3" = 1'-0" CAD Details ENTRANCE = TF_VG_450_Ent-Center--CAD.zip NOTE: OTHER TYPES OF KAWNEER DOORS MAY BE USED WITH THIS FRAMING SYSTEM. SEE ENTRANCE DETAILS FOR ADDITIONAL INFORMATION. 6 7 1 450-033 INSERT 10 2 4 5 9 8 450-110 STEEL (As Required) 450-501 or 450-019 3 3 Transom area for both double or single acting doors with glass surround. Jambs above transom bar are routed out to accept glass holding insert with or without steel reinforcing. ELEVATIONS ARE NUMBER KEYED TO DETAILS 1-3/4" (44.5) SINGLE ACTING 1 450-081 1 450-502 450-500 450-CG-001 450-CG-001 4-1/2" (114.3) 10 10 450-022 STOPS 450-022 STOPS 450-501 450-081 2 DOUBLE ACTING 4 5 450-501 2 450-502 4-1/2" (114.3) 450-500 1-3/4" (44.5) 450-019 3 SINGLE ACTING DOOR 8 9 450-019 3 Optional Bottom Rail Sweep 069-139 SINGLE ACTING DOOR WITH TRANSOM 069-143 DOUBLE ACTING DOOR WITH TRANSOM DOUBLE ACTING DOOR kawneer.com © Kawneer Company, Inc., 2009 7 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 6 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® VG 450 FRAMING INCORPORATING KAWNEER® “190” DOORS. TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 19 ENTRANCE FRAMING (CENTER-Open Back)) SCALE 3" = 1'-0" CAD Details ENTRANCE = TF_VG_450_Ent-Center--CAD.zip NOTE: OTHER TYPES OF KAWNEER DOORS MAY BE USED WITH THIS FRAMING SYSTEM. SEE ENTRANCE DETAILS FOR ADDITIONAL INFORMATION. 6 7 1 6 7 450-033 INSERT 10 450-CG-002 450-CG-028 2 4 5 9 8 450-110 STEEL (As Required) 3 3 Transom area for both double or single acting doors with glass surround. Jambs above transom bar are routed out to accept glass holding insert with or without steel reinforcing. ELEVATIONS ARE NUMBER KEYED TO DETAILS SINGLE ACTING 1-3/4" (44.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® VG 450 FRAMING INCORPORATING KAWNEER® “190” DOORS. 1 DOUBLE ACTING 450-081 1 450-502 450-500 450-CG-001 450-CG-001 10 10 4 5 450-022 STOPS 450-022 STOPS 450-081 2 450-599 2 450-500 450-599 450-CG-002 450-CG-028 4-1/2" (114.3) 450-502 1-3/4" (44.5) © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4-1/2" (114.3) SINGLE ACTING SINGLE ACTING DOOR DOUBLE ACTING 450-064 450-081 8 9 450-502 450-500 10 10 DOUBLE ACTING DOOR kawneer.com 450-064 TRIFAB® VG 450 20 TM GLASSvent JANUARY, 2009 (CENTER) EC 97911-07 SCALE 3" = 1'-0" CAD Details SHEAR BLOCK = TF_VG_450-SB-Center--CAD.zip CAD Details STICK = TF_VG_450-Stick-Center--CAD.zip PROJECT-OUT VERTICAL SECTION SHOWN OUTSWING CASEMENT VERTICAL SECTION SHOWN 450-CG-011 1 1 3 450-CG-004 450-CG-001 5 6 2 3 7 8 4 450-CG-011 450-CG-001 ELEVATION IS NUMBER KEYED TO DETAILS 2 4 450-CG-004 450-CG-001 450-CG-002 450-CG-002 5 450-CG-001 450-CG-001 450-CG-002 6 7 450-CG-002 8 MAXIMUM / MINIMUM SIZES (1/4" INFILL) PROJECT-OUT MAXIMUM 60" x 36" MINIMUM 12" x 12" OUTSWING CASEMENT MAXIMUM 36" x 60" MINIMUM 12" x 12" kawneer.com © Kawneer Company, Inc., 2009 450-CG-001 PROJECT-OUT HORIZONTAL SECTION SHOWN Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. OUTSWING CASEMENT HORIZONTAL SECTION SHOWN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CAD Details SCREW SPLINE = TF_VG_450-SS-Center--CAD.zip TRIFAB® VG 450 JANUARY, 2009 GLASSventTM (CENTER) EC 97911-07 STOREFRONT GLASSvent™ HARDWARE SELECTION GUIDE PROJECT - OUT OUTSWING CASEMENT Stainless steel 4-bar hinge STANDARD STANDARD Cast white bronze cam lock STANDARD STANDARD Cast white bronze cam lock with pole ring OPTIONAL OPTIONAL Cast white bronze custodial lock with removable handle OPTIONAL OPTIONAL Cast white bronze concealed lock with removable hex key OPTIONAL OPTIONAL Cast white bronze pole/pull ring OPTIONAL Pivot-shoe roto-operator OPTIONAL Multi-point lock with cast white bronze locking handle OPTIONAL Insect screen CAM LOCK REMOVABLE HANDLE OPTIONAL CAM LOCK WITH POLE RING ROTO-OPERATOR OPTIONAL PULL RING CUSTODIAL LOCK STAINLESS STEEL 4 BAR HINGES © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DESCRIPTION CONCEALED LOCK kawneer.com INSECT SCREEN WITH STANDARD WICKET INSECT SCREEN WITH FULL WICKET 21 TRIFAB® VG 450 22 JANUARY, 2009 VENTS (CENTER) EC 97911-07 SCALE 3" = 1'-0" CAD Details SHEAR BLOCK = TF_VG_450-SB-Center--CAD.zip CAD Details STICK = TF_VG_450-Stick-Center--CAD.zip Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CAD Details SCREW SPLINE = TF_VG_450-SS-Center--CAD.zip PROJECT-OUT VERTICAL SECTION 7225 VENTS SHOWN NOTE: OTHER VENT TYPES CAN BE ACCOMMODATED, CONSULT YOUR KAWNEER REPRESENTATIVE FOR OTHER OPTIONS 450-CG-011 1 450-CG-004 1 4 3 2 2 450-CG-004 450-CG-011 PROJECT-OUT HORIZONTAL SECTION 450-CG-005 3 450-CG-005 4 kawneer.com © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. ELEVATION IS NUMBER KEYED TO DETAILS JANUARY, 2009 EC 97911-07 TRIFAB® VG 450 23 INDEX (FRONT) MISCELLANEOUS FRAMING..................................................... 31,32 CORNERS......................................................................................... 33 ENTRANCE FRAMING..................................................................... 34 GLASSvent™ .............................................................................. 35-36 VENTS............................................................................................... 37 © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. BASIC FRAMING DETAILS......................................................... 24-30 kawneer.com TRIFAB® VG 450 24 JANUARY, 2009 BASIC FRAMING DETAILS (FRONT - Outside Glazed) EC 97911-07 SCALE 3" = 1'-0" 5 2 3 ELEVATION IS NUMBER KEYED TO DETAILS SCREW SPLINE SHEAR BLOCK STICK CAD Details = TF_VG_450-SS-Front--CAD.zip CAD Details = TF_VG_450-SB-Front--CAD.zip CAD Details = TF_VG_450-Stick-Front--CAD.zip 1-3/4" (44.5) 450-VG-012 450-VG-001 450-VG-001 450-VG-005 4-1/2" (114.3) 450-VG-026 1-3/4" (44.5) 1 HEAD 4 JAMB 5 VERTICAL 1 HEAD 450-VG-004 1 HEAD 450-VG-004 450-VG-003 4 JAMB 450-VG-004 450-VG-011 450-VG-011 450-VG-004 450-VG-004 450-VG-008 450-VG-011 2 HORIZONTAL 2 HORIZONTAL 450-VG-026 451-VG-006 450-VG-003 4-1/2" (114.3) 2 HORIZONTAL 5 VERTICAL 2-1/4" (57.15) 5 VERTICAL 4 JAMB 4-1/2" (114.3) 450-VG-005 450-VG-026 450-VG-004 450-VG-026 450-VG-007 450-VG-001 450-037 *See page 31 for Optional High Performance Flashing. 3 SILL 450-037 3 SILL 2-1/4" (57.15) 3 SILL 450-VG-001 451-VG-106 *See page 31 for Optional High Performance Flashing. kawneer.com © Kawneer Company, Inc., 2009 450-VG-001 1-3/4" (44.5) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 BASIC FRAMING DETAILS (FRONT - Inside Glazed) 1 4 5 2 3 ELEVATION IS NUMBER KEYED TO DETAILS SCREW SPLINE SHEAR BLOCK STICK CAD Details = TF_VG_450-SS-Front--CAD.zip CAD Details = TF_VG_450-SB-Front--CAD.zip CAD Details = TF_VG_450-Stick-Front--CAD.zip 1-3/4" (44.5) 450-VG-001 450-VG-012 1-3/4" (44.5) 450-VG-001 450-VG-001 450-VG-005 450-VG-026 1-3/4" (44.5) 1 HEAD 450-VG-103 4 JAMB 5 VERTICAL 1 HEAD 450-VG-103 4 JAMB 1 HEAD 5 VERTICAL 2-1/4" (57.15) 5 VERTICAL 4 JAMB 4-1/2" (114.3) 450-VG-005 4-1/2" (114.3) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SCALE 3" = 1'-0" 450-VG-104 4-1/2" (114.3) 450-VG-111 450-VG-111 2 HORIZONTAL 451-VG-006 450-VG-108 450-VG-104 450-VG-104 450-VG-111 2 HORIZONTAL 2 HORIZONTAL 450-VG-104 450-VG-104 450-VG-001 450-VG-001 450-VG-104 450-VG-007 3 SILL 450-037 *See page 31 for Optional High Performance Flashing. kawneer.com 3 SILL 450-037 *See page 31 for Optional High Performance Flashing. 3 SILL 2-1/4" (57.15) © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 25 451-VG-106 TRIFAB® VG 450 JANUARY, 2009 BASIC FRAMING DETAILS (FRONT) EC 97911-07 1 4 1A Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SCALE 3" = 1'-0" 5 2 3 ELEVATION IS NUMBER KEYED TO DETAILS STICK SYSTEM (INSIDE GLAZED) TWO COLOR OPTION STANDARD RECEPTOR with SSG ADAPTOR CAD Details STICK = TF_VG_450-Stick-Front--CAD.zip 1-3/4" (44.5) TYP. 450-VG-131 450-SSG-005 450-SSG-005 450-SSG-005 4-1/2" (114.3) TYP. 450-VG-131 450-VG-130 4 JAMB 5 VERTICAL 450-SSG-129 5B WEATHERSEAL VERTICAL 5A SSG VERTICAL 4A SSG JAMB 1 HEAD 2-1/4" (57.15) 450-SSG-328 451-VG-130 451-VG-006 451-VG-006 450-VG-108 1A HEAD 450-VG-104 450-VG-108 451-VG-130 2 HORIZONTAL 1-3/4" (44.5) 450-SSG-111 450-VG-104 450-SSG-111 2A HORIZONTAL 450-SSG-004 450-SSG-004 451-VG-130 450-VG-104 450-VG-104 450-VG-007 450-VG-007 3 SILL 2-1/4" (57.15) 451-VG-130 3A SILL 451-VG-106 451-VG-106 450-SSG-328 kawneer.com © Kawneer Company, Inc., 2009 450-SSG-250 450-VG-130 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 26 TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 BASIC FRAMING DETAILS (FRONT) 1 4 1A 5 2 3 ELEVATION IS NUMBER KEYED TO DETAILS STICK SYSTEM (INSIDE GLAZED) SSG RECEPTOR STICK SYSTEM (OUTSIDE GLAZED) SSG RECEPTOR CAD Details STICK SSG = TF_VG_450-Stick-SSG-Front--CAD.zip CAD Details STICK SSG = TF_VG_450-Stick-SSG-Front--CAD.zip 1-3/4" (44.5) TYP. 450-SSG-005 450-SSG-005 450-SSG-005 450-SSG-005 4-1/2" (114.3) TYP. 450-SSG-005 1-3/4" (44.5) TYP. 4-1/2" (114.3) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SCALE 3" = 1'-0" 450-SSG-129 4 SSG JAMB 5 SSG VERTICAL 4 SSG JAMB 5 WEATHERSEAL VERTICAL 5 SSG VERTICAL 2 HORIZONTAL 450-SSG-008 1 HEAD 2-1/4" (57.15) 2-1/4" (57.15) 450-SSG-006 1 HEAD 450-SSG-007 450-SSG-111 450-SSG-111 2 HORIZONTAL 450-SSG-004 450-VG-104 450-VG-104 450-SSG-007 kawneer.com 450-SSG-007 3 SILL 450-SSG-106 2-1/4" (57.15) 3 SILL 450-SSG-106 450-SSG-104 450-SSG-004 2-1/4" (57.15) © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 450-SSG-250 450-SSG-129 450-SSG-106 27 TRIFAB® VG 450 JANUARY, 2009 BASIC FRAMING DETAILS (FRONT) EC 97911-07 1 4 1A Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SCALE 3" = 1'-0" 5 2 3 ELEVATION IS NUMBER KEYED TO DETAILS STICK SYSTEM (INSIDE GLAZED) SSG RECEPTOR TWO COLOR OPTION CAD Details STICK SSG = TF_VG_450-Stick-SSG-Front--CAD.zip 450-SSG-005 450-SSG-005 450-SSG-005 450-SSG-250 450-SSG-129 4 SSG JAMB 5 SSG VERTICAL 5 WEATHERSEAL VERTICAL 2-1/4" (57.15) 450-SSG-006 1 HEAD 451-VG-130 450-SSG-008 450-SSG-104 450-SSG-111 2 HORIZONTAL 450-SSG-004 450-VG-104 3 SILL 2-1/4" (57.15) 451-VG-130 450-SSG-106 kawneer.com © Kawneer Company, Inc., 2009 4-1/2" (114.3) TYP. 1-3/4" (44.5) TYP. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 28 TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 BASIC FRAMING DETAILS (FRONT) SCALE 3" = 1'-0" 1A Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 4 5 TYPE-B MULTI-LITE PUNCHED OPENINGS (20 FEET MAXIMUM UNIT WIDTH) 2 3 ELEVATION IS NUMBER KEYED TO DETAILS TYPE-B (INSIDE GLAZED) PUNCHED OPENING CAD Details TYPE-B = TF_VG_450_Type-B_Front--CAD.zip 1-3/4" (44.5) 450-VG-101 4 JAMB 5 VERTICAL 450-VG-103 450-VG-104 4-1/2" (114.3) TYP. 450-VG-111 2 HORIZONTAL 450-VG-104 450-VG-101 3 SILL kawneer.com 450-VG-325 1A HEAD 1-3/4" (44.5) TYP. 1-3/4" (44.5) TYP. 450-VG-327 1 HEAD © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4-1/2" (114.3) 450-VG-005 450-VG-103 450-VG-104 4-1/2" (114.3) TYP. 29 30 TRIFAB® VG 450 JANUARY, 2009 BASIC FRAMING DETAILS (FRONT) EC 97911-07 SCALE 3" = 1'-0" 4 5 TYPE B: MULTI-LITE PUNCHED OPENINGS (20 FEET MAXIMUM UNIT WIDTH) 2 3 ELEVATION IS NUMBER KEYED TO DETAILS TYPE-B (INSIDE GLAZED) SSG/WEATHERSEAL PUNCHED OPENING CAD Details TYPE-B = TF_VG_450_Type-B_Front--CAD.zip 1-3/4" (44.5) TYP. 450-VG-101 450-SSG-005 450-SSG-005 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1A 1 5 SSG VERTICAL 5A WEATHERSEAL VERTICAL Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 JAMB 450-VG-103 450-VG-104 2 HORIZONTAL 450-SSG-004 4-1/2" (114.3) TYP. 1A HEAD 1-3/4" (44.5) TYP. 1 HEAD 1-3/4" (44.5) TYP. 450-VG-327 450-VG-103 450-VG-104 4-1/2" (114.3) TYP. 450-SSG-111 450-VG-104 450-VG-101 3 SILL 450-VG-325 kawneer.com © Kawneer Company, Inc., 2009 450-SSG-250 TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 MISCELLANEOUS FRAMING (FRONT) SCALE 3" = 1'-0" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CAD Details SCREW SPLINE = TF_VG_450-SS-Front--CAD.zip CAD Details SHEAR BLOCK = TF_VG_450-SB-Front--CAD.zip 450-VG-540 450-VG-010 450-026 450-087 EXPANSION MULLION SNAP-IN FLAT POCKET FILLER SNAP-IN FLAT FILLER 451-VG-570 2" (50.8) TYPICAL 451-VG-570 451-VG-573 451-VG-572 5-1/2" (139.7) TYPICAL 451-VG-374 CLIP HEAVY WEIGHT HEAD COMPENSATING RECEPTOR STANDARD HEAD COMPENSATING RECEPTOR 451-VG-571 451-VG-570 ONE PIECE HEAD COMPENSATING RECEPTOR 451-VG-572 JAMB COMPENSATING RECEPTOR © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. CAD Details STICK = TF_VG_450-Stick-Front--CAD.zip 451-HP-126 CLIP 451-HP-037 HIGH PERFORMANCE FLASHING kawneer.com 31 32 TRIFAB® VG 450 JANUARY, 2009 MISCELLANEOUS FRAMING (FRONT) EC 97911-07 SCALE 3" = 1'-0" CAD Details STICK = TF_VG_450-Stick-Front--CAD.zip 450-VG-006 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CAD Details SHEAR BLOCK = TF_VG_450-SB-Front--CAD.zip 2" (50.8) 2" (50.8) 450-VG-006 450-VG-362 2" (50.8) 2" (50.8) MULLION ANCHOR 450-VG-006 450-VG-106 OPTIONAL LIGHTWEIGHT CAN RECEPTORS (Stick System) SSG MULLION ANCHOR NOTE: If the end reaction of the mullion (mullion spacing (ft.) times height (ft.) times specified windload (psf) divided by two) is more than 500 lbs., the optional Mullion Anchors must be used. NOTE: Mullion Anchor not used with Lightweight Receptor. 451-VG-150 BRAKE METAL FILLERS BRAKE METAL FILLERS 451-VG-150 451-VG-150 451-VG-150 BRAKE METAL ADAPTOR AT HORIZONTAL BRAKE METAL ADAPTOR AT VERTICAL STOOL TRIM 450-VG-640 STOOL TRIM CLIP WITH STANDARD FLASHING STOOL TRIM 450-VG-640 STOOL TRIM CLIP WITH HIGH PERFORMANCE FLASHING STOOL TRIM 069-271 STOOL TRIM CLIP FOR STICK/TYPE-B ASSEMBLY kawneer.com © Kawneer Company, Inc., 2009 450-SSG-362 OPTIONAL UNEQUAL LEG CAN RECEPTORS (Stick System) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. CAD Details SCREW SPLINE = TF_VG_450-SS-Front--CAD.zip TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 33 CORNERS (FRONT) SCALE 3" = 1'-0" CAD Details SHEAR BLOCK = TF_VG_450-SB-Front--CAD.zip CAD Details STICK = TF_VG_450-Stick-Front--CAD.zip 450-VG-015 450-017 450-017 4-1/2" (114.3) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CAD Details SCREW SPLINE = TF_VG_450-SS-Front--CAD.zip 060-119 450-VG-015 450-017 450-VG-035 4-1/2" (114.3) TYP. 4-1/2" x 4-1/2" TUBE 450-VG-010 TWO PIECE NO POCKET CORNER ONE POCKET CORNER 450-VG-010 450-VG-010 BRAKE METAL FILLERS TWO POCKET 90o CORNER 450-VG-010 BRAKE METAL FILLERS BRAKE METAL FILLERS TWO POCKET BRAKE METAL POST VARIABLE DEGREE BRAKE METAL OUTSIDE CORNER 450-VG-010 VARIABLE DEGREE BRAKE METAL INSIDE CORNER 450-SSG-016 450-SSG-116 © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 450-VG-010 450-SSG-115 450-SSG-116 450-SSG-115 450-SSG-015 450-SSG-135 90o SSG CORNER o 90 CORNER kawneer.com 135o CORNER 135o SSG CORNER TRIFAB® VG 450 34 JANUARY, 2009 ENTRANCE FRAMING (FRONT) EC 97911-07 SCALE 3" = 1'-0" CAD Details ENTRANCE = TF_VG_450-Entrance-Front--CAD.zip NOTE: OTHER TYPES OF KAWNEER DOORS MAY BE USED WITH THIS FRAMING SYSTEM. SEE ENTRANCE DETAILS FOR ADDITIONAL INFORMATION. 1 450-VG-033 INSERT 6 7 10 2 4 5 9 8 450-VG-019 7 6 3 3 450-VG-019 Transom area for both double or single acting doors with glass surround. Jambs above transom bar are routed out to accept glass holding insert. ELEVATIONS ARE NUMBER KEYED TO DETAILS 1-3/4" (44.5) TYP. SINGLE ACTING 1 DOUBLE ACTING 450-081 1 450-502 450-500 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® VG 450 FRAMING INCORPORATING KAWNEER® “190” DOORS. 450-VG-001 450-VG-001 450-VG-022 10 4 5 450-022 450-VG-022 2 450-VG-019 450-081 450-VG-019 450-502 450-500 4-1/2" (114.3) TYP. 069-177 1-3/4" (44.5) TYP. 069-177 SINGLE ACTING DOOR 450-VG-019 450-VG-019 8 3 9 3 069-139 SINGLE ACTING DOOR WITH TRANSOM 069-143 DOUBLE ACTING DOOR WITH TRANSOM DOUBLE ACTING DOOR kawneer.com © Kawneer Company, Inc., 2009 451-VG-004 450-022 10 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 451-VG-004 4-1/2" (114.3) TYP. TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 35 GLASSvent™ (FRONT) SCALE 3" = 1'-0" CAD Details SHEAR BLOCK = TF_VG_450-SB-Front--CAD.zip CAD Details STICK = TF_VG_450-Stick-Front--CAD.zip PROJECT-OUT VERTICAL SECTION SHOWN OUTSWING CASEMENT VERTICAL SECTION SHOWN 3 450-VG-003 5 450-VG-026 6 2 3 7 8 4 ELEVATION IS NUMBER KEYED TO DETAILS 2 450-VG-011 450-VG-001 4 450-VG-026 OUTSWING CASEMENT HORIZONTAL SECTION SHOWN 450-VG-005 5 © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 450-VG-004 450-VG-011 1 450-VG-004 1 450-VG-004 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CAD Details SCREW SPLINE = TF_VG_450-SS-Front--CAD.zip PROJECT-OUT HORIZONTAL SECTION SHOWN 450-VG-005 450-VG-005 450-VG-005 6 7 8 MAXIMUM / MINIMUM SIZES (1/4" INFILL) kawneer.com PROJECT-OUT MAXIMUM 60" x 36" MINIMUM 12" x 12" OUTSWING CASEMENT MAXIMUM 36" x 60" MINIMUM 12" x 12" TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 GLASSvent™ (FRONT) OUTSWING CASEMENT Stainless steel 4-bar hinge STANDARD STANDARD Cast white bronze cam lock STANDARD STANDARD Cast white bronze cam lock with pole ring OPTIONAL OPTIONAL Cast white bronze custodial lock with removable handle OPTIONAL OPTIONAL Cast white bronze concealed lock with removable hex key OPTIONAL OPTIONAL Cast white bronze pole/pull ring OPTIONAL Pivot-shoe roto-operator OPTIONAL Multi-point lock with cast white bronze locking handle OPTIONAL Insect screen CAM LOCK REMOVABLE HANDLE CONCEALED LOCK OPTIONAL CAM LOCK WITH POLE RING ROTO-OPERATOR INSECT SCREEN WITH STANDARD WICKET OPTIONAL PULL RING CUSTODIAL LOCK STAINLESS STEEL 4 BAR HINGES INSECT SCREEN WITH FULL WICKET kawneer.com © Kawneer Company, Inc., 2009 PROJECT - OUT DESCRIPTION Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. STOREFRONT GLASSvent™ HARDWARE SELECTION GUIDE Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 36 TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 VENTS (FRONT) SCALE 3" = 1'-0" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CAD Details SCREW SPLINE = TF_VG_450-SS-Front--CAD.zip CAD Details SHEAR BLOCK = TF_VG_450-SB-Front--CAD.zip CAD Details STICK = TF_VG_450-Stick-Front--CAD.zip PROJECT-OUT VERTICAL SECTION 450-VG-111 7225 VENTS SHOWN NOTE: OTHER VENT TYPES CAN BE ACCOMMODATED, CONSULT YOUR KAWNEER REPRESENTATIVE FOR OTHER OPTIONS 1 450-VG-104 1 4 3 2 ELEVATION IS NUMBER KEYED TO DETAILS 2 450-VG-104 PROJECT-OUT HORIZONTAL SECTION 450-VG-005 450-VG-005 3 4 © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 450-VG-111 kawneer.com 37 kawneer.com © Kawneer Company, Inc., 2009 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® VG 450 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 38 JANUARY, 2009 EC 97911-07 © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JANUARY, 2009 EC 97911-07 kawneer.com TRIFAB® VG 450 39 INDEX (BACK) BASIC FRAMING DETAILS......................................................... 40,41 MISCELLANEOUS FRAMING..................................................... 42,43 CORNERS......................................................................................... 44 ENTRANCE FRAMING..................................................................... 45 TRIFAB® VG 450 40 JANUARY, 2009 BASIC FRAMING DETAILS (BACK - Outside Glazed) EC 97911-07 SCALE 3" = 1'-0" 5 2 3 ELEVATION IS NUMBER KEYED TO DETAILS SCREW SPLINE SHEAR BLOCK STICK CAD Details = TF_VG_450-SS-Back--CAD.zip CAD Details = TF_VG_450-SB-Back--CAD.zip CAD Details = TF_VG_450-Stick-Back--CAD.zip 450-VG-001 4-1/2" (114.3) TYP. 450-VG-026 450-VG-005 1-3/4" (44.5) TYP. 1 HEAD 450-VG-103 4 JAMB 1 HEAD 450-VG-005 4 JAMB 5 VERTICAL 450-VG-103 1 HEAD 2-1/4" (57.15) 5 VERTICAL 4 JAMB 5 VERTICAL 451-VG-006 450-VG-108 450-VG-104 450-VG-104 450-VG-104 4-1/2" (114.3) TYP. 450-VG-111 450-VG-111 2 HORIZONTAL 450-VG-104 450-VG-104 450-VG-001 3 SILL 450-037 *See page 42 for Optional High Performance Flashing. 450-VG-111 2 HORIZONTAL 450-VG-104 450-VG-001 3 SILL 450-037 450-VG-007 3 SILL 2-1/4" (57.15) 2 HORIZONTAL 451-VG-106 *See page 42 for Optional High Performance Flashing. kawneer.com © Kawneer Company, Inc., 2009 450-VG-001 1-3/4" (44.5) TYP. 4-1/2" (114.3) TYP. 450-VG-012 450-VG-001 1-3/4" (44.5) TYP. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 41 BASIC FRAMING DETAILS (BACK - Inside Glazed) SCALE 3" = 1'-0" 4 5 2 3 ELEVATION IS NUMBER KEYED TO DETAILS SCREW SPLINE SHEAR BLOCK STICK CAD Details = TF_VG_450-SS-Back--CAD.zip CAD Details = TF_VG_450-SB-Back--CAD.zip CAD Details = TF_VG_450-Stick-Back--CAD.zip 450-VG-001 450-VG-026 450-VG-001 450-VG-005 1 HEAD 2-1/4" (57.15) 450-VG-004 450-VG-004 450-VG-008 450-VG-011 *See page 42 for Optional High Performance Flashing. kawneer.com 2 HORIZONTAL 450-VG-026 450-VG-001 450-VG-026 451-VG-130 450-VG-001 3 SILL 450-037 *See page 42 for Optional High Performance Flashing. 3 SILL 2-1/4" (57.15) 450-037 450-VG-011 450-VG-004 450-VG-004 450-VG-011 2 HORIZONTAL 450-VG-026 3 SILL 450-VG-006 450-VG-003 4-1/2" (114.3) TYP. 2 HORIZONTAL 5 VERTICAL 450-VG-004 1-3/4" (44.5) TYP. 450-VG-005 4 JAMB 5 VERTICAL 1 HEAD 450-VG-003 © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 HEAD 4 JAMB 450-VG-004 5 VERTICAL 4 JAMB 1-3/4" (44.5) TYP. 4-1/2" (114.3) TYP. 450-VG-012 450-VG-001 1-3/4" (44.5) TYP. 4-1/2" (114.3) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 451-VG-106 450-VG-007 42 TRIFAB® VG 450 JANUARY, 2009 MISCELLANEOUS FRAMING (BACK) EC 97911-07 SCALE 3" = 1'-0" CAD Details SHEAR BLOCK = TF_VG_450-SB-Back--CAD.zip CAD Details STICK = TF_VG_450-Stick-Back--CAD.zip Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 450-087 450-026 450-VG-010 EXPANSION MULLION SNAP-IN FLAT FILLER FLAT FILLER 451-VG-570 2" (50.8) TYPICAL 451-VG-570 451-VG-573 451-VG-572 5-1/2" (139.7) TYPICAL 451-VG-374 CLIP HEAVY WEIGHT HEAD COMPENSATING RECEPTOR STANDARD HEAD COMPENSATING RECEPTOR 451-VG-571 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 450-VG-540 451-VG-570 ONE PIECE HEAD COMPENSATING RECEPTOR 451-VG-572 JAMB COMPENSATING RECEPTOR 451-HP-126 CLIP 451-HP-037 HIGH PERFORMANCE FLASHING kawneer.com © Kawneer Company, Inc., 2009 CAD Details SCREW SPLINE = TF_VG_450-SS-Back--CAD.zip TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 43 MISCELLANEOUS FRAMING (BACK) SCALE 3" = 1'-0" CAD Details SHEAR BLOCK = TF_VG_450-SB-Back--CAD.zip CAD Details STICK = TF_VG_450-Stick-Back--CAD.zip 450-VG-006 2" (50.8) 450-VG-006 450-VG-362 2" (50.8) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CAD Details SCREW SPLINE = TF_VG_450-SS-Back--CAD.zip MULLION ANCHOR NOTE: If the end reaction of the mullion (mullion spacing (ft.) times height (ft.) times specified windload (psf) divided by two) is more than 500 lbs., the optional Mullion Anchors must be used. 450-VG-106 OPTIONAL LIGHTWEIGHT CAN RECEPTORS 450-VG-006 OPTIONAL UNEQUAL LEG CAN RECEPTORS (Stick System) NOTE: Mullion Anchor not used with Lightweight Receptor. BRAKE METAL FILLERS BRAKE METAL FILLERS 451-VG-150 451-VG-150 451-VG-150 BRAKE METAL ADAPTOR AT HORIZONTAL BRAKE METAL ADAPTOR AT VERTICAL © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 451-VG-150 STOOL TRIM 450-VG-640 STOOL TRIM CLIP WITH STANDARD FLASHING kawneer.com STOOL TRIM STOOL TRIM 450-VG-640 STOOL TRIM CLIP WITH HIGH PERFORMANCE FLASHING 069-271 STOOL TRIM CLIP FOR STICK ASSEMBLY 44 TRIFAB® VG 450 JANUARY, 2009 CORNERS (BACK) EC 97911-07 SCALE 3" = 1'-0" CAD Details SHEAR BLOCK = TF_VG_450-SB-Back--CAD.zip 450-VG-015 4-1/2" (114.3) TYP. 450-017 CAD Details STICK = TF_VG_450-Stick-Back--CAD.zip Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 060-119 450-017 4-1/2" (114.3) TYP. 4-1/2" x 4-1/2" TUBE 450-017 TWO PIECE NO POCKET CORNER ONE POCKET CORNER 450-VG-010 450-VG-010 450-VG-010 BRAKE METAL FILLERS 450-VG-010 BRAKE METAL FILLERS BRAKE METAL FILLERS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 450-VG-010 450-VG-010 90o OUTSIDE BRAKE METAL CORNER TWO POCKET BRAKE METAL POST VARIABLE DEGREE BRAKE METAL OUTSIDE CORNER 450-VG-010 BRAKE METAL FILLERS BRAKE METAL FILLERS 450-VG-010 450-VG-010 450-VG-010 90o INSIDE BRAKE METAL CORNER VARIABLE DEGREE BRAKE METAL INSIDE CORNER kawneer.com © Kawneer Company, Inc., 2009 CAD Details SCREW SPLINE = TF_VG_450-SS-Back--CAD.zip TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 45 ENTRANCE FRAMING (BACK) SCALE 3" = 1'-0" CAD Details ENTRANCE = TF_VG_450-Entrance-Back--CAD.zip NOTE: OTHER TYPES OF KAWNEER DOORS MAY BE USED WITH THIS FRAMING SYSTEM. SEE ENTRANCE DETAILS FOR ADDITIONAL INFORMATION. 1 6 7 10 450-VG-033 INSERT 2 4 9 8 5 450-VG-019 3 3 450-VG-019 Transom area for both double or single acting doors with glass surround. Jambs above transom bar are routed out to accept glass holding insert. ELEVATIONS ARE NUMBER KEYED TO DETAILS SINGLE ACTING 1 DOUBLE ACTING 450-081 1 450-502 450-500 450-VG-001 450-VG-001 4-1/2" (114.3) TYP. 10 450-022 450-022 450-VG-022 450-VG-022 451-VG-004 2 2 450-VG-019 451-VG-004 450-081 4 10 5 450-VG-019 450-502 450-500 069-177 4-1/2" (114.3) TYP. © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 7 6 1-3/4" (44.5) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® VG 450 FRAMING INCORPORATING KAWNEER® “190” DOORS. 1-3/4" (44.5) TYP. 069-177 SINGLE ACTING DOOR 450-VG-019 450-VG-019 8 3 3 069-139 SINGLE ACTING DOOR WITH TRANSOM kawneer.com 9 069-143 DOUBLE ACTING DOOR WITH TRANSOM DOUBLE ACTING DOOR kawneer.com © Kawneer Company, Inc., 2009 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® VG 450 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 46 JANUARY, 2009 EC 97911-07 © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JANUARY, 2009 EC 97911-07 kawneer.com TRIFAB® VG 450 (See appropriate Center, Front or Back Section for Miscellaneous Details.) 47 INDEX (MULTI-PLANE) BASIC FRAMING DETAILS......................................................... 48-53 TRIFAB® VG 450 48 JANUARY, 2009 BASIC FRAMING DETAILS (MULTI-PLANE - Outside Glazed) EC 97911-07 SCREW SPLINE ASSEMBLY BACK FRONT 10 7 FRONT CENTER 11 12 13 2 5 8 3 6 9 14 ELEVATION IS NUMBER KEYED TO DETAILS CAD Details MULTI-PLANE (SCREW SPLINE) = TF_VG_450-SS+SB-MULTI--CAD.zip 10 JAMB 11 VERTICAL 450-CG-002 450-VG-001 12 VERTICAL 450-VG-052 450-VG-001 13 VERTICAL 14 JAMB 450-CG-028 450-VG-069 4-1/2" (114.3) TYP. 450-VG-001 1-3/4" (44.5) TYP. 1 HEAD 450-VG-004 4 HEAD 450-VG-003 450-VG-026 8 HORIZONTAL 450-VG-104 450-CG-004 450-VG-001 450-VG-001 450-CG-011 450-CG-001 9 SILL 6 SILL 450-037 450-CG-003 4-1/2" (114.3) TYP. 450-VG-111 5 HORIZONTAL 3 SILL 450-CG-004 4-1/2" (114.3) TYP. 450-VG-011 2 HORIZONTAL 7 HEAD 450-VG-104 4-1/2" (114.3) 450-VG-004 450-VG-103 1-3/4" (44.5) TYP. CENTER See Pages 12 thru 22 for all CENTER details. 1-3/4" (44.5) TYP. BACK See Pages 40 thru 45 for all BACK details. 1-3/4" (44.5) FRONT See Pages 24 thru 37 for all FRONT details. 450-037 450-037 kawneer.com © Kawneer Company, Inc., 2009 4 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SCALE 3" = 1'-0" TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 49 BASIC FRAMING DETAILS (MULTI-PLANE - Inside Glazed) SCREW SPLINE ASSEMBLY SCALE 3" = 1'-0" 1 4 BACK 11 12 2 5 8 3 6 9 14 ELEVATION IS NUMBER KEYED TO DETAILS 1-3/4" (44.5) TYP. 11 VERTICAL 450-CG-002 450-VG-001 450-VG-052 450-VG-001 13 VERTICAL 14 JAMB 450-CG-028 450-VG-069 4-1/2" (114.3) TYP. 450-VG-001 12 VERTICAL 4 HEAD 450-VG-104 450-VG-104 kawneer.com 8 HORIZONTAL 450-VG-026 450-CG-011 450-VG-001 450-VG-001 450-CG-004 450-CG-001 9 SILL 6 SILL 450-037 450-CG-004 4-1/2" (114.3) TYP. 450-VG-011 5 HORIZONTAL 3 SILL 450-CG-003 4-1/2" (114.3) TYP. 450-VG-111 2 HORIZONTAL 7 HEAD 450-VG-003 4-1/2" (114.3) 450-VG-004 450-VG-103 1-3/4" (44.5) TYP. CENTER See Pages 12 thru 22 for all CENTER details. 450-VG-004 BACK See Pages 40 thru 45 for all BACK details. 1-3/4" (44.5) FRONT See Pages 24 thru 37 for all FRONT details. 1 HEAD © Kawneer Company, Inc., 2009 13 CAD Details MULTI-PLANE (SCREW SPLINE) = TF_VG_450-SS+SB-MULTI--CAD.zip 10 JAMB Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. FRONT CENTER 1-3/4" (44.5) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FRONT 10 7 450-037 450-037 TRIFAB® VG 450 50 JANUARY, 2009 BASIC FRAMING DETAILS (MULTI-PLANE - Outside Glazed) EC 97911-07 SHEAR BLOCK ASSEMBLY BACK FRONT 10 7 FRONT CENTER 11 12 13 2 5 8 3 6 9 14 ELEVATION IS NUMBER KEYED TO DETAILS CAD Details MULTI-PLANE (SHEAR BLOCK) = TF_VG_450-SS+SB-MULTI--CAD.zip 10 JAMB 11 VERTICAL 450-CG-002 450-VG-001 12 VERTICAL 450-VG-052 450-VG-001 13 VERTICAL 14 JAMB 450-CG-028 450-VG-069 4-1/2" (114.3) TYP. 450-VG-001 Note: Transition verticals are required to be two piece. 1-3/4" (44.5) TYP. 1 HEAD 450-VG-004 4 HEAD 450-VG-003 450-VG-103 7 HEAD 1-3/4" (44.5) TYP. CENTER See Pages 12 thru 22 for all CENTER details. 1-3/4" (44.5) TYP. BACK See Pages 40 thru 45 for all BACK details. 1-3/4" (44.5) TYP. FRONT See Pages 24 thru 37 for all FRONT details. 450-CG-004 450-VG-104 4-1/2" (114.3) TYP. 4-1/2" (114.3) TYP. 450-VG-011 450-VG-004 450-VG-111 8 HORIZONTAL 5 HORIZONTAL 2 HORIZONTAL 450-VG-026 450-VG-104 450-CG-011 450-CG-001 9 SILL 6 SILL 450-037 450-CG-004 450-VG-001 450-VG-001 3 SILL 450-CG-003 450-037 450-037 kawneer.com © Kawneer Company, Inc., 2009 4 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SCALE 3" = 1'-0" TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 51 BASIC FRAMING DETAILS (MULTI-PLANE - Inside Glazed) SHEAR BLOCK ASSEMBLY SCALE 3" = 1'-0" 1 4 BACK 11 12 2 5 8 3 6 9 14 ELEVATION IS NUMBER KEYED TO DETAILS Note: Transition verticals are required to be two piece 1-3/4" (44.5) TYP. 11 VERTICAL 450-CG-002 450-VG-001 450-VG-052 450-VG-001 13 VERTICAL 14 JAMB 450-CG-028 450-VG-069 4-1/2" (114.3) TYP. 450-VG-001 12 VERTICAL 4 HEAD 450-VG-111 450-VG-104 kawneer.com 450-CG-011 450-CG-004 8 HORIZONTAL 450-VG-026 450-VG-001 450-VG-001 450-CG-001 9 SILL 6 SILL 450-037 450-CG-004 450-VG-011 5 HORIZONTAL 3 SILL 450-CG-003 4-1/2" (114.3) TYP. 4-1/2" (114.3) TYP. 2 HORIZONTAL 7 HEAD 450-VG-003 450-VG-104 450-VG-004 450-VG-103 1-3/4" (44.5) TYP. CENTER See Pages 12 thru 22 for all CENTER details. 450-VG-004 BACK See Pages 40 thru 45 for all BACK details. 1-3/4" (44.5) TYP. FRONT See Pages 24 thru 37 for all FRONT details. 1 HEAD © Kawneer Company, Inc., 2009 13 CAD Details MULTI-PLANE (SHEAR BLOCK) = TF_VG_450-SS+SB-MULTI--CAD.zip 10 JAMB Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. FRONT CENTER 1-3/4" (44.5) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FRONT 10 7 450-037 450-037 TRIFAB® VG 450 52 JANUARY, 2009 BASIC FRAMING DETAILS (MULTI-PLANE - Outside Glazed) EC 97911-07 STICK ASSEMBLY FRONT 4 BACK FRONT 10 12 13 2 5 8 3 6 9 14 ELEVATION IS NUMBER KEYED TO DETAILS Note: Transition verticals are required to be two piece. 1-3/4" (44.5) TYP. 11 VERTICAL 450-VG-052 450-VG-001 13 VERTICAL 14 JAMB 450-CG-028 450-CG-002 450-VG-001 4-1/2" (114.3) TYP. 450-VG-069 10 JAMB FRONT CENTER 11 CAD Details MULTI-PLANE (STICK) = TF_VG_450-Stick-MULTI--CAD.zip 450-VG-001 7 12 VERTICAL 450-VG-111 450-VG-026 450-VG-104 3 SILL 2-1/4" (57.2) 450-CG-004 450-CG-003 8 HORIZONTAL 450-CG-007 450-VG-007 2-1/4" (57.15) 451-VG-106 450-CG-002 5 HORIZONTAL 450-VG-007 450-CG-008 7 HEAD 4 HEAD 450-VG-011 451-VG-006 450-CG-004 450-VG-104 2 HORIZONTAL 2-1/4" (57.15) 450-VG-108 450-VG-008 1 HEAD 450-VG-004 451-VG-006 451-VG-106 6 SILL 2-1/4" (57.2) 450-VG-004 451-VG-006 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. CENTER See Pages 12 thru 22 for all CENTER details. 2-1/4" (57.15) BACK See Pages 40 thru 45 for all BACK details. 2-1/4" (57.15) FRONT See Pages 24 thru 37 for all FRONT details. 451-VG-106 9 SILL kawneer.com © Kawneer Company, Inc., 2009 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SCALE 3" = 1'-0" TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 53 BASIC FRAMING DETAILS (MULTI-PLANE - Inside Glazed) STICK ASSEMBLY SCALE 3" = 1'-0" 1 BACK FRONT 10 11 12 5 8 3 6 9 1-3/4" (44.5) TYP. 11 VERTICAL 450-VG-001 13 VERTICAL 14 JAMB BACK CENTER See Pages 40 thru 45 for all BACK details. See Pages 12 thru 22 for all CENTER details. 450-VG-006 451-VG-006 2-1/4" (57.2) 2-1/4" (57.15) 451-VG-006 450-VG-108 450-VG-052 450-CG-028 12 VERTICAL FRONT See Pages 24 thru 37 for all FRONT details. 450-CG-002 450-VG-001 2-1/4" (57.15) 14 13 2 450-VG-069 450-VG-001 FRONT CENTER ELEVATION IS NUMBER KEYED TO DETAILS Note: Transition verticals are required to be two piece CAD Details MULTI-PLANE (STICK) = TF_VG_450-Stick-MULTI--CAD.zip 10 JAMB 450-VG-004 450-VG-104 450-VG-008 1 HEAD 450-CG-008 450-CG-002 450-VG-004 450-VG-011 450-VG-104 450-CG-003 450-VG-026 2 HORIZONTAL 3 SILL kawneer.com 450-CG-007 450-VG-007 2-1/4" (57.2) 2-1/4" (57.15) 2-1/4" (57.15) 451-VG-106 451-VG-130 450-CG-004 8 HORIZONTAL 5 HORIZONTAL 450-VG-007 450-CG-004 7 HEAD 4 HEAD 450-VG-111 © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 7 4-1/2" (114.3) TYP. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FRONT 4 451-VG-106 6 SILL 451-VG-106 9 SILL kawneer.com © Kawneer Company, Inc., 2009 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® VG 450 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 54 JANUARY, 2009 EC 97911-07 TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 55 INDEX (CHARTS) CENTER .................................................................................... 56-58 FRONT or BACK....................................................................... 59,60 FRONT (SSG/WEATHERSEAL) .................................................... 61 MULTI-PLANE................................................................................ 62 EXPANSION MULLIONS ............................................................... 63 ENTRANCE FRAMING ............................................................. 64-66 DEADLOAD CHARTS ................................................................ 67,68 END REACTION CHARTS ............................................................... 69 THERMAL CHARTS .................................................................... 70,73 © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WINDLOAD CHARTS kawneer.com TRIFAB® VG 450 56 JANUARY, 2009 WINDLOAD CHARTS (CENTER) EC 97911-07 NOTE: If the end reaction of the mullion (mullion spacing (ft.) times height (ft.) times specified windload (psf) divided by two) is more than 500 lbs., the optional Mullion Anchors must be used. Consult Application Engineering. (Mullion Anchor not used with Lightweight Receptor.) WIDTH IN METERS 1 1.5 WITHOUT HORIZONTALS WIDTH IN METERS .5 2 2 10 3 9 A 8 B C D 7 E 6 5 2.5 2 1.5 4 1 2 3 4 5 6 7 8 HEIGHT IN FEET 3.5 11 4 13 HEIGHT IN METERS 12 12 3.5 11 A3 10 B C 2.5 D E 9 8 7 2 450-CG-001 450-CG-002 6 I = 2.899 (120.67 x 104) S = 1.288 (21.11 x 103) 4 5 1.5 1 2 3 4 5 6 7 8 WIDTH IN FEET WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 HEIGHT IN METERS 4 13 WIDTH IN METERS .5 2 1 1.5 2 15 15 14 14 4 12 B 3.5 11 C D 10 3 E 9 2.5 8 7 2 6 5 1.5 4 1 2 3 4 5 6 WIDTH IN FEET 7 8 A 11 4 B C 3.5 D 10 E3 13 HEIGHT IN FEET A HEIGHT IN METERS 13 12 9 2.5 8 7 450-CG-001 450-CG-002 WITH 450-110 STEEL 4 IA = 2.899 (120.67 x 10 ) SA = 1.288 (21.11 x 103) HEIGHT IN METERS HEIGHT IN FEET 1.5 14 14 HEIGHT IN FEET 1 15 15 2 6 5 1.5 4 1 2 3 4 5 6 7 8 WIDTH IN FEET IS = 1.935 (80.54 x 104) SS = 0.938 (15.37 x 103) kawneer.com © Kawneer Company, Inc., 2009 C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) E = 40 PSF (1920 Pa) WITH HORIZONTALS .5 (720 Pa) (960 Pa) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. A = 15 PSF B = 20 PSF Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L\175 up to 13'-6" and L\240 + 1/4" above 13'-6". These curves are for mullions WITH and WITHOUT HORIZONTALS and are based on precise engineering calculations for stress and deflection. Allowable windload stress for ALUMINUM 15,152 P.S.I. (104 MPa), FORMED STEEL 30,000 P.S.I. (207 MPa), STEEL BAR 20,000 P.S.I. (138 MPa). Charted curves, in all cases, are for the limiting value. For special situations not covered by these curves, contact your Kawneer representative for additional information. TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 WINDLOAD CHARTS (CENTER) (720 Pa) (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) E = 40 PSF (1920 Pa) WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 WIDTH IN METERS .5 2 A3 10 9 B C 2.5 D E 2 8 1.5 4 1 2 3 4 5 6 7 12 A 10 B 3 C D E 2.5 9 8 7 8 450-CG-013 450-CG-002 6 I = 4.481 (186.51 x 104) S = 1.991 (32.63 x 103) 4 5 1.5 1 2 3 4 5 6 7 8 WIDTH IN FEET WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS 1 1.5 3.5 11 2 6 5 HEIGHT IN FEET 3.5 11 4 13 HEIGHT IN METERS 12 7 WIDTH IN METERS 2 .5 15 1 1.5 2 15 14 14 B C 11 10 D E 9 3.5 3 2.5 8 7 5 1.5 4 1 2 3 4 5 6 WIDTH IN FEET 7 8 A 12 B 3.5 C D 3 E 11 10 9 2.5 8 7 2 6 4 13 2 450-CG-013 450-CG-002 with 400-110 STEEL IA = 4.481 (186.51 x 104) SA = 1.991 (32.63 x 103) IS = 0.970 (40.37 x 104) SS = 0.535 (8.76 x 103) 6 5 1.5 4 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 12 HEIGHT IN FEET A HEIGHT IN METERS 4 13 HEIGHT IN FEET 2 HEIGHT IN METERS 4 13 .5 © Kawneer Company, Inc., 2009 1.5 14 14 kawneer.com 1 15 15 HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 15 PSF B = 20 PSF Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 57 TRIFAB® VG 450 JANUARY, 2009 WINDLOAD CHARTS (CENTER) EC 97911-07 (720 Pa) (960 Pa) E = 40 PSF (1920 Pa) WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 WIDTH IN METERS 2 .5 15 2 14 4 3.5 11 10 3 9 A 8 B C D 7 6 2.5 3 4 5 6 7 10 3 A B C 2.5 D E 2 9 8 6 5 I = 2.523 (105.01 x 104) S = 1.121 (18.37 x 103) 4 2 3.5 11 7 450-CG-005 1.5 1 12 2 E 5 4 13 HEIGHT IN FEET 12 HEIGHT IN METERS 13 8 1.5 4 1 2 3 4 5 6 7 8 WIDTH IN FEET WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 WIDTH IN METERS 2 .5 15 1 1.5 2 15 14 14 12 4 B 3.5 11 10 C D 9 E 3 2.5 8 7 A 13 HEIGHT IN FEET A HEIGHT IN METERS 13 4 B 12 3.5 C D E3 11 10 9 2.5 8 7 2 HEIGHT IN METERS HEIGHT IN FEET 1.5 HEIGHT IN METERS 14 HEIGHT IN FEET 1 15 2 6 6 5 1.5 450-CG-005 with 450-110 STEEL 4 5 1.5 4 1 2 3 4 5 6 WIDTH IN FEET 7 8 IA = 2.523 (105.01 x 104) SA = 1.121 (18.37 x 103) 1 2 3 4 5 6 7 8 WIDTH IN FEET IS = 1.935 (80.54 x 104) SS = 0.938 (15.37 x 103) kawneer.com © Kawneer Company, Inc., 2009 C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 15 PSF B = 20 PSF Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 58 TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 WINDLOAD CHARTS (FRONT or BACK) (720 Pa) (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) E = 40 PSF (1920 Pa) WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 WIDTH IN METERS 2 .5 15 3 A B 2.5 9 8 7 C D 6 E 3 4 5 6 7 3.5 11 A3 B C 2.5 D E 10 9 8 2 1.5 2 12 7 2 4 1 4 8 450-VG-012 450-VG-026 6 I = 3.074 (127.95 x 104) S = 1.192 (19.53 x 103) 4 5 1.5 1 2 3 4 5 6 7 8 WIDTH IN FEET WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS WIDTH IN METERS 1 1.5 HEIGHT IN METERS 10 HEIGHT IN FEET 3.5 11 5 2 .5 15 1 1.5 2 15 14 14 11 B 10 C3 D 3.5 9 E 8 2.5 7 13 HEIGHT IN FEET A HEIGHT IN METERS 12 5 1.5 4 1 2 3 4 5 6 WIDTH IN FEET 7 8 4 B 3.5 11 C D 10 E 9 3 2.5 8 7 2 6 A 12 2 450-VG-012 450-VG-026 with 1" x 2-1/2" STEEL BAR IA = 3.074 (127.95 x 104) SA = 1.192 (19.53 x 103) IS = 1.302 (54.19 x 104) SS = 1.042 (17.08 x 103) 6 5 1.5 4 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 4 13 HEIGHT IN FEET 2 13 HEIGHT IN METERS 12 .5 © Kawneer Company, Inc., 2009 1.5 14 4 13 kawneer.com 1 15 14 HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 15 PSF B = 20 PSF Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 59 TRIFAB® VG 450 JANUARY, 2009 WINDLOAD CHARTS (FRONT or BACK) (720 Pa) (960 Pa) E = 40 PSF (1920 Pa) WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 WIDTH IN METERS .5 2 2 10 3 A B 2.5 9 8 7 C D 6 E 5 3 4 5 6 7 3.5 11 A3 B C 2.5 D E 10 9 8 7 2 6 450-VG-005 5 I = 2.978 (123.95 x 104) S = 1.192 (19.53 x 103) 4 2 12 2 1.5 1 HEIGHT IN FEET 3.5 11 HEIGHT IN METERS 12 4 13 8 1.5 4 1 2 3 4 5 6 7 8 WIDTH IN FEET WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 HEIGHT IN METERS 4 13 WIDTH IN METERS 2 .5 15 1 1.5 2 15 14 14 4 A 11 B C3 D 10 9 E 8 3.5 2.5 7 HEIGHT IN FEET 12 4 13 HEIGHT IN METERS 13 A 12 B 3.5 11 C D 10 E 9 3 2.5 8 7 2 HEIGHT IN METERS HEIGHT IN FEET 1.5 14 14 HEIGHT IN FEET 1 15 15 2 6 6 5 1.5 450-VG-005 with 1" x 2-1/2" STEEL BAR 4 5 1.5 4 1 2 3 4 5 6 WIDTH IN FEET 7 8 IA = 2.978 (123.95 x 104) SA = 1.192 (19.53 x 103) 1 2 3 4 5 6 7 8 WIDTH IN FEET IS = 1.302 (54.19 x 104) SS = 1.042 (17.08 x 103) kawneer.com © Kawneer Company, Inc., 2009 C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 15 PSF B = 20 PSF EC 97911-07 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 60 TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 WINDLOAD CHARTS (SSG/WEATHERSEAL) (720 Pa) (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) E = 40 PSF (1920 Pa) WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 WIDTH IN METERS .5 2 1.5 2 14 4 3.5 11 10 3 9 A 8 E D C 2.5 B 7 HEIGHT IN FEET 12 4 13 HEIGHT IN METERS 13 12 3.5 11 10 3 A 9 2.5 8 E D C B 7 2 2 6 6 5 450-SSG-005 1.5 1 2 3 4 5 6 7 5 I = 2.445 (101.76 x 104) S = 1.352 (22.15 x 103) 4 8 1.5 4 1 3 4 5 6 7 8 WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS 1 1.5 WIDTH IN METERS 2 .5 15 1 1.5 2 15 14 14 3.5 E D C B 10 3 9 2.5 8 7 HEIGHT IN FEET A 11 HEIGHT IN METERS 12 4 13 A 12 3.5 11 E D C B 10 3 9 2.5 8 7 2 2 6 6 5 1.5 450-SSG-005 with 1" x 2-1/2" STEEL BAR 4 5 1.5 4 1 2 3 4 5 6 WIDTH IN FEET 7 8 IA = 2.445 (101.76 x 104) SA = 1.352 (22.15 x 103) IS = 1.302 (54.19 x 104) SS = 1.042 (17.08 x 103) 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 4 13 HEIGHT IN FEET 2 WIDTH IN FEET WIDTH IN METERS kawneer.com HEIGHT IN METERS 14 .5 © Kawneer Company, Inc., 2009 1 15 15 HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 15 PSF B = 20 PSF Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 61 TRIFAB® VG 450 62 JANUARY, 2009 WINDLOAD CHARTS (MULTI-PLANE) A = 15 PSF B = 20 PSF WITH HORIZONTALS 1 1.5 (720 Pa) (960 Pa) WITHOUT HORIZONTALS C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) WIDTH IN METERS .5 EC 97911-07 2 WIDTH IN METERS .5 E = 40 PSF (1920 Pa) 15 B 2.5 8 C D 7 6 1.5 2 3 4 5 6 7 8 E 7 2 4 1 9 2 E 5 A 3 B C D 2.5 10 8 WIDTH IN FEET 450-VG-069 450-VG-069 6 I = 3.246 (135.10 x 104) S = 1.132 (18.55 x 103) 4 5 1.5 2 1 WITH HORIZONTALS 1 1.5 4 5 6 7 8 WITHOUT HORIZONTALS WIDTH IN METERS .5 3 WIDTH IN FEET WIDTH IN METERS 2 .5 15 1 1.5 2 15 14 14 10 6 3 A B 2.5 C D 2 E 5 1.5 9 8 7 2 3 4 5 6 7 12 3.5 11 A3 B C 2.5 D E 10 9 8 7 2 4 1 HEIGHT IN FEET 3.5 11 HEIGHT IN METERS 12 4 13 8 450-VG-001 450-CG-002 6 I = 3.031 (126.15 x 104) S = 1.239 (23.30 x 103) 4 5 1.5 1 2 3 4 5 6 7 8 WIDTH IN FEET WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 HEIGHT IN METERS 4 13 WIDTH IN METERS .5 2 1 1.5 2 15 15 14 4 3.5 11 10 3 A B 2.5 9 8 7 C D 6 E 5 1 2 3 4 5 6 WIDTH IN FEET 7 8 12 3.5 11 A3 10 B C 2.5 D E 9 8 7 2 2 1.5 4 HEIGHT IN FEET 12 4 13 HEIGHT IN METERS 13 HEIGHT IN METERS 14 450-VG-052 450-CG-028 6 I = 2.998 (124.79 x 104) S = 1.235 (20.24 x 103) 4 5 1.5 1 2 3 4 5 6 7 8 WIDTH IN FEET kawneer.com © Kawneer Company, Inc., 2009 3 A 9 3.5 11 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 10 12 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3.5 11 4 13 HEIGHT IN FEET 12 HEIGHT IN METERS HEIGHT IN FEET 2 HEIGHT IN METERS 4 13 HEIGHT IN FEET 1.5 14 14 HEIGHT IN FEET 1 15 TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 WINDLOAD CHARTS (EXPANSION MULLIONS) A = 15 PSF B = 20 PSF WITH HORIZONTALS .5 1 1.5 (720 Pa) (960 Pa) WITHOUT HORIZONTALS C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) WIDTH IN METERS 2 WIDTH IN METERS .5 E = 40 PSF (1920 Pa) 15 2 11 A 10 9 3 B C 2.5 D E 2 8 7 1.5 4 1 2 3 4 5 6 7 3.5 11 A B3 10 C D 2.5 E 9 8 7 2 6 5 12 8 WIDTH IN FEET 450-CG-540 450-CG-010 6 I = 3.846 (160.08 x 104) S = 1.710 (28.02 x 103) 4 5 1.5 1 2 1.5 4 5 6 7 8 WITHOUT HORIZONTALS WIDTH IN METERS 1 3 WIDTH IN FEET WITH HORIZONTALS .5 WIDTH IN METERS .5 2 1 1.5 2 15 15 14 12 A 3.5 B C3 D 11 10 9 E 8 2.5 7 4 13 HEIGHT IN FEET 4 HEIGHT IN METERS 13 A 12 B 3.5 11 C D 10 E 9 2.5 8 7 2 2 1.5 4 1 WIDTH IN FEET I = 3.846 (160.08 x 104) S = 1.710 (28.02 x 103) WITH HORIZONTALS IS = 0.970 (40.37 x 104) SS = 0.535 (8.76 x 103) 2 3 4 5 6 7 6 450-CG-540 450-CG-010 WITH 400-110 STEEL 6 5 8 5 1.5 4 1 1 1.5 4 5 6 7 8 WIDTH IN METERS 2 .5 1 1.5 2 15 14 4 3.5 11 A 10 3 B C 2.5 D E 2 9 8 7 6 5 1.5 4 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN FEET 12 4 13 HEIGHT IN METERS 13 12 3.5 11 A B3 C D 2.5 E 10 9 8 7 2 450-VG-540 450-VG-010 6 I = 4.117 (171.36 x 104) S = 1.704 (27.92 x 103) 4 5 1.5 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 14 HEIGHT IN FEET 3 WITHOUT HORIZONTALS 15 © Kawneer Company, Inc., 2009 2 WIDTH IN FEET WIDTH IN METERS .5 3 HEIGHT IN METERS 14 kawneer.com HEIGHT IN METERS 3.5 HEIGHT IN FEET 12 4 13 HEIGHT IN METERS HEIGHT IN FEET 1.5 14 4 13 HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 15 14 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 63 TRIFAB® VG 450 JANUARY, 2009 WINDLOAD CHARTS (ENTRANCES) EC 97911-07 (720 Pa) B = 20 PSF (960 Pa) C = 25 PSF (1200 Pa) WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 WIDTH IN METERS 2 .5 15 14 2 3 9 A 8 7 B C D 6 E 5 2.5 2 1.5 2 1 3 4 5 6 7 3 A B C 2.5 D E 9 8 7 6 450-019 5 I = 2.813 (117.08 x 104) S = 1.250 (20.48 x 103) 8 10 2 450-501 4 3.5 11 1.5 4 1 2 3 4 5 6 7 8 WIDTH IN FEET WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 HEIGHT IN METERS 10 12 HEIGHT IN FEET 3.5 11 4 13 HEIGHT IN METERS 12 WIDTH IN METERS .5 2 1 1.5 2 15 15 14 14 12 B 3.5 11 C D 10 3 E 9 2.5 8 7 2 6 1.5 4 1 2 3 4 5 6 WIDTH IN FEET 7 8 4 11 B C 3.5 D 10 E3 12 9 2.5 8 7 2 450-019 6 WITH 450-110 STEEL 5 450-501 5 A 13 HEIGHT IN FEET A HEIGHT IN METERS 13 4 4 IA = 2.813 (117.08 x 10 ) SA = 1.250 (20.48 x 103) HEIGHT IN METERS HEIGHT IN FEET 1.5 14 4 13 HEIGHT IN FEET 1 15 1.5 4 1 2 3 4 5 6 7 8 WIDTH IN FEET IS = 1.935 (80.57 x 104) SS = 0.938 (15.37 x 103) kawneer.com © Kawneer Company, Inc., 2009 D = 30 PSF (1440 Pa) E = 40 PSF (1920 Pa) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 15 PSF Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 64 TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 WINDLOAD CHARTS (ENTRANCES) (720 Pa) (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) E = 40 PSF (1920 Pa) WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 WIDTH IN METERS .5 2 10 3 A 9 B 2.5 C D E2 8 1.5 2 3 4 5 6 7 3.5 11 A 3 B C D 2.5 E 10 9 8 7 450-599 450-CG-002 4 1 12 2 6 5 HEIGHT IN FEET 3.5 11 4 13 HEIGHT IN METERS 12 7 6 450-064 450-CG-002 5 8 1.5 4 I = 3.226 (134.28 x 104) S = 1.467 (24.04 x 103) 1 2 3 4 5 6 7 8 WIDTH IN FEET WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 WIDTH IN METERS 2 .5 15 1 1.5 2 15 14 12 B 11 C D 10 E 9 3.5 3 2.5 8 7 5 1.5 1 2 3 4 5 6 WIDTH IN FEET 7 8 12 11 C 3.5 D 10 E 3 9 2.5 8 2 450-599 450-CG-002 450-064 450-CG-002 WITH 450-110 STEEL 4 4 B 7 2 6 A 13 HEIGHT IN FEET 13 4 HEIGHT IN METERS A IA = 3.226 (134.28 x 104) SA = 1.467 (24.04 x 103) IS = 1.935 (80.57 x 104) SS = 0.938 (15.37 x 103) 6 5 1.5 4 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 14 HEIGHT IN FEET 2 HEIGHT IN METERS 4 13 © Kawneer Company, Inc., 2009 1.5 14 14 kawneer.com 1 15 15 HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 15 PSF B = 20 PSF Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 65 TRIFAB® VG 450 JANUARY, 2009 WINDLOAD CHARTS (ENTRANCES) EC 97911-07 (720 Pa) E = 40 PSF (1920 Pa) WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 WIDTH IN METERS 2 .5 15 14 2 10 3 9 A B 2.5 8 7 C D 6 E 5 3 4 5 6 7 A3 10 B C 2.5 D E 9 8 2 6 450-VG-019 5 I = 2.985 (124.24 x 104) S = 1.244 (20.38 x 103) 4 2 3.5 11 7 2 1.5 1 12 8 1.5 4 1 2 3 4 5 6 7 8 WIDTH IN FEET WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 HEIGHT IN METERS 3.5 11 HEIGHT IN FEET 12 4 13 HEIGHT IN METERS WIDTH IN METERS .5 2 1 1.5 2 15 15 14 14 4 A 11 B C3 D 10 9 E 8 3.5 2.5 7 HEIGHT IN FEET 12 4 13 HEIGHT IN METERS 13 A 12 B 3.5 11 C D 10 E 9 2.5 8 7 2 2 6 5 1.5 4 1 2 3 4 5 6 WIDTH IN FEET 7 8 3 HEIGHT IN METERS HEIGHT IN FEET 1.5 14 4 13 HEIGHT IN FEET 1 15 450-VG-019 WITH 1" x 2-1/2" STEEL BAR 6 IA = 2.985 (124.24 x 104) SA = 1.244 (20.38 x 103) 4 5 1.5 1 2 3 4 5 6 7 8 WIDTH IN FEET IS = 1.302 (54.19 x 104) SS = 1.042 (17.08 x 103) kawneer.com © Kawneer Company, Inc., 2009 B = 20 PSF (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 15 PSF Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 66 TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 67 DEADLOAD CHARTS Horizontal or deadload limitations are based upon 1/8" (3.2) maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1/4" (6.4) thick glass supported on two setting blocks at the loading points shown. C = (1/8 POINT LOADING) WIDTH IN METERS 1 1.5 WIDTH IN METERS 2 1 11 10 3 7 2 6 5 1.5 4 3 C B A 2 1 450-CG-011 450-CG-003 2.5 8 7 2 6 5 1.5 4 1 3 2 .5 1 C B .5 A 1 0 1 2 3 4 5 6 7 0 8 1 2 3 4 5 6 7 WIDTH IN FEET WIDTH IN FEET WIDTH IN METERS WIDTH IN METERS 1.5 2 1 11 HEIGHT IN METERS 2.5 8 HEIGHT IN FEET 9 HEIGHT IN METERS 1.5 8 2 11 10 10 3 9 3 7 2 6 5 1.5 C 4 B 3 1 A 2 .5 1 450-VG-011 450-VG-111 HEIGHT IN FEET 2.5 8 HEIGHT IN METERS 9 2.5 8 7 2 6 5 1.5 4 3 C B 2 A 1 .5 1 0 1 2 3 4 5 6 WIDTH IN FEET kawneer.com 7 8 0 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS HEIGHT IN FEET 2 10 3 9 HEIGHT IN FEET 1.5 11 1 © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = (1/4 POINT LOADING) B = (1/6 POINT LOADING) TRIFAB® VG 450 68 JANUARY, 2009 DEADLOAD CHARTS EC 97911-07 Horizontal or deadload limitations are based upon 1/8" (3.2) maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1/4" (6.4) thick glass supported on two setting blocks at the loading points shown. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = (1/4 POINT LOADING) B = (1/6 POINT LOADING) C = (1/8 POINT LOADING) WIDTH IN METERS 1 1.5 2 11 10 3 2.5 8 7 2 6 5 1.5 4 1 3 HEIGHT IN METERS HEIGHT IN FEET 9 450-SSG-011 C B 2 .5 A 1 0 1 2 3 4 5 6 7 8 WIDTH IN FEET DEADLOADS ON ENTRANCE TRANSOM BARS WIDTH IN METERS WIDTH IN METERS 1 1.5 1 2 2 10 3 3 7 2 6 5 1.5 4 C 3 B A 2 1 .5 450-500 TRAY 450-502 SINGLE ACTING T-BAR 450-081 DOUBLE ACTING T-BAR HEIGHT IN FEET 2.5 8 HEIGHT IN METERS 9 9 2.5 8 7 2 6 5 1.5 4 1 3 2 C B A 1 1 0 0 1 2 3 4 5 6 WIDTH IN FEET 7 8 1 2 3 4 5 6 7 HEIGHT IN METERS 10 HEIGHT IN FEET 1.5 11 11 .5 8 WIDTH IN FEET kawneer.com © Kawneer Company, Inc., 2009 A = (1/4 POINT LOADING) B = (1/6 POINT LOADING) C = (1/8 POINT LOADING) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Height limitations for transom glass over a doorway are based upon a 1/16" (1.6) maximum allowable deflection at the center of a transom bar. The accompanying charts are calculated for 1/4" (6.4) thick glass supported on two setting blocks placed at the loading points shown. TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 69 END REACTION CHARTS A = 15 PSF B = 20 PSF (720 Pa) (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) WITH HORIZONTALS 1 1.5 WIDTH IN METERS 2 .5 15 451-VG-006 2 14 4 13 12 4 13 A 12 3.5 11 3.5 3 9 A 2.5 8 7 B 6 2 5 C 1.5 4 D 3 E 451-VG-106 451-SSG-006 HEIGHT IN FEET 10 HEIGHT IN METERS 11 10 B 9 C 8 D 7 E 1 2 5 1.5 1 2 .5 1 0 0 2 3 4 5 6 7 8 2.5 6 3 .5 1 3 4 1 451-SSG-106 WIDTH IN FEET 1 2 3 4 5 6 WIDTH IN FEET 500lbs. Max. End Reaction © Kawneer Company, Inc., 2009 1.5 7 8 HEIGHT IN METERS 14 kawneer.com 1 15 2 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. WITHOUT HORIZONTALS E = 40 PSF (1920 Pa) WIDTH IN METERS .5 HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. For each application, end reactions MUST be checked. These charts are used to verify that the end reactions at the head and sill receptors are 500 lbs. (2224N) or less and will meet the specified windload. TRIFAB® VG 450 JANUARY, 2009 THERMAL CHARTS EC 97911-07 Project Specific U-factor Example Calculation 15'-8" 2'-0" 9'-6" 7'-0" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 5'-0" Example Glass U-factor = 0.42 Btu/hr·ft2·oF Total Daylight Opening = 3(5' x 7') + 3(5' x 2') = 135ft2 Total Projected Area = (Total Daylight Opening + Total Area of Framing System) = 15'-8" x 9'-6" = 148.83ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area) = (135 ÷ 148.83)100 = 91% System U-factor vs Percent of Glass Area 0.80 0.60 0.55 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.50 0.45 0.40 0.35 0.49 0.30 0.25 91% 70 75 80 85 90 0.20 Percent of Glass Based on 91% glass and Center of Glass (COG) U-factor of 0.42 System U-factor is equal to 0.49 Btu/hr·ft2·oF kawneer.com © Kawneer Company, Inc., 2009 0.65 System U-factor (BTU/hr·ft2·oF) 0.70 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.75 95 70 TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 71 THERMAL CHARTS TRIFAB® VG 450 (CENTER) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-factor vs Percent of Glass Area 1.50 1.45 1.35 1.30 1.25 COG U-factor 1.20 1.15 1.10 1.06 1.04 1.02 1.00 0.98 0.96 0.94 0.92 0.90 1.05 1.00 0.95 Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. kawneer.com 70 75 80 85 90 95 0.85 © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.90 System U-factor (BTU/hr·ft2·oF) 1.40 TRIFAB® VG 450 JANUARY, 2009 THERMAL CHARTS EC 97911-07 TRIFAB® VG 450 (CENTER) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC 0.85 0.85 0.80 0.80 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.90 0.90 0.75 0.75 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 System SHGC 0.70 0.70 0.15 70 75 80 85 90 95 0.10 Vision Area / Total Area (%) 0.90 0.90 0.85 0.85 0.80 0.80 0.75 0.75 0.70 0.70 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 System VT 0.65 0.65 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 70 75 80 85 90 0.10 Vision Area / Total Area (%) kawneer.com © Kawneer Company, Inc., 2009 COG VT Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System Visible Transmittance (VT) vs Percent of Vision Area 95 72 TRIFAB® VG 450 JANUARY, 2009 EC 97911-07 THERMAL PERFORMANCE MATRIX TRIFAB® VG 450 (CENTER) Glass U-Factor 3 Overall U-Factor 4 0.90 0.99 0.92 1.00 0.94 1.02 0.96 1.03 0.98 1.05 1.00 1.07 1.02 1.08 1.04 1.10 1.06 1.11 SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall Glass U-Factor 4 Glass VT 3 Overall VT 4 0.90 0.81 0.90 0.81 0.85 0.77 0.85 0.76 0.80 0.72 0.80 0.72 0.75 0.68 0.75 0.67 0.70 0.63 0.70 0.63 0.65 0.59 0.65 0.58 0.60 0.54 0.60 0.54 0.55 0.50 0.55 0.49 0.50 0.45 0.50 0.45 0.45 0.41 0.45 0.40 0.40 0.37 0.40 0.36 0.35 0.32 0.35 0.31 0.30 0.28 0.30 0.27 0.25 0.23 0.25 0.22 0.20 0.19 0.20 0.18 © Kawneer Company, Inc., 2009 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Thermal Transmittance 1 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). kawneer.com 73 kawneer.com © Kawneer Company, Inc., 2009 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TRIFAB® VG 450 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 74 JANUARY, 2009 EC 97911-07