EnCORETM FEBRUARY, 2014 EC 97911-055 FEATURES FEATURES Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. • • • • • • • • • • Economical 1-3/4" sight line with a 3-9/16", 4-1/2" or 6" depth Front or Center (4-1/2") glass applications Outside glazed Screw Spline, Shear Block or Type-B fabrication SSG option Infill options up to 1-1/8" Thermal break via. Polymer glazing clip PermanodicTM anodized finishes in seven standard choices Painted finishes in standard and custom choices OPTIONAL FEATURES PRODUCT APPLICATIONS • • • • • Storefront, Ribbon Window or Punched Openings Low to mid-rise Single-span Curved frames Integrated entrance framing allowing Kawneer entrances or other specialty entrances to be included • Kawneer windows or GLASSventTM for storefront are easily incorporated © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. • Two color capability • 1-1/4" perimeter sight line • Project specific U-factors (See Thermal Charts) For specific product applications, consult your Kawneer Representative kawneer.com ADMC080 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EnCORETM BLANK PAGE ADMC080 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 FEBRUARY, 2014 EC 97911-055 EnCORETM FEBRUARY, 2014 INDEX PICTORIAL VIEWS........................................................................... 5-8 BASIC FRAMING DETAILS............................................................ 9-20 MISCELLANEOUS FRAMING...................................................... 21,22 GLAZING CHART.............................................................................. 22 GLASSventTM FOR STOREFRONT.............................................. 23,24 VENTS................................................................................................ 25 ENTRANCE FRAMING................................................................. 26-32 WINDLOAD/DEADLOAD CHARTS.............................................. 33-41 DEADLOAD CHARTS.................................................................. 42-46 THERMAL CHARTS..................................................................... 47-51 GLAZING CLIP CHART..................................................................... 52 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-055 3 Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMC080 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EnCORETM BLANK PAGE ADMC080 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 FEBRUARY, 2014 EC 97911-055 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FEBRUARY, 2014 kawneer.com EnCORETM EC 97911-055 PICTORIAL VIEW (SCREW SPLINE ASSEMBLY) SPLIT MULLION FLAT FILLER HEAD SPLINE SCREWS WATER DEFLECTOR INTERMEDIATE HORIZONTAL SPLINE SCREWS SETTING BLOCK CHAIR GLAZING CLIP SILL COVER SILL FLASHING ADMC080 5 (Standard Mullion Show SSG Optional) HEAD SHEAR BLOCK SETTING BLOCK CHAIR GLAZING CLIP SILL COVER SILL FLASHING ADMC080 kawneer.com © Kawneer Company, Inc., 2014 PICTORIAL VIEW (SHEAR BLOCK ASSEMBLY) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EnCORETM Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 6 FEBRUARY, 2014 EC 97911-055 MULLION WATER DEFLECTOR INTERMEDIATE HORIZONTAL © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FEBRUARY, 2014 kawneer.com EnCORETM EC 97911-055 PICTORIAL VIEW (TYPE-B ASSEMBLY) MULLION HEAD GLAZING CLIP SHEAR BLOCK WATER DEFLECTOR INTERMEDIATE HORIZONTAL SPLINE SCREWS SETTING BLOCK CHAIR GLAZING CLIP SILL 5/16" Dia. WEEP HOLE COVER ADMC080 7 PICTORIAL VIEW (TYPE-B SSG ASSEMBLY) SSG MULLION HEAD SHEAR BLOCK SPLINE SCREWS ADMC080 COVER SETTING BLOCK CHAIR GLAZING CLIP SILL kawneer.com © Kawneer Company, Inc., 2014 DETAILS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EnCORETM Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 8 FEBRUARY, 2014 EC 97911-055 GLAZING CLIP INTERMEDIATE HORIZONTAL 175155 4 JAMB kawneer.com 175003 2 2 HORIZONTAL 175021 175505 3 SILL 1-3/4" (44.5) TYP. MULLION 175155 175155 175155 5 4 JAMB 5 SPLIT MULLION ADMC080 175007 175023 175171 ADAPTER HORIZONTAL 175155 1 HEAD 175007 175155 175021 3-9/16" (90.5) TYP. 175002 FLASHING 175155 175155 175155 175155 1/4" INFILL 5/8" (15.9) 175155 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-055 175005 175001 175027 175025 175021 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. FEBRUARY, 2014 EnCORETM 9 3-9/16" SYSTEM (SCREW SPLINE) SCALE 3" = 1'-0" ELEVATION IS NUMBER KEYED TO DETAILS 1" INFILL 175001 1 HEAD 175003 175171 ADAPTER 2A HORIZONTAL W/ 1/4" ADAPTER 175001 175002 FLASHING 175504 3 SILL 175005 175155 5A SPLIT MULLION W/ 1/4" ADAPTER 175155 175155 4 JAMB 5 MULLION 5/8" (15.9) 3 SILL ADMC080 175051 175073 175071 175504 1-3/4" (44.5) TYP. 175050 1 HEAD 1 HEAD w/ caulk leg 175053 175171 ADAPTER 2 HORIZONTAL 2A HORIZONTAL W/ 1/4" ADAPTER 175051 175052 FLASHING 3 SILL 1-3/4" (44.5) TYP. 175055 175155 175155 4 JAMB 5 SPLIT MULLION 175155 5A SPLIT MULLION W/ 1/4" ADAPTER kawneer.com © Kawneer Company, Inc., 2014 1" INFILL Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. ELEVATION IS NUMBER KEYED TO DETAILS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 175155 175155 4-1/2" SYSTEM (SCREW SPLINE) 175057 2 HORIZONTAL 175155 1 HEAD 175057 175155 175155 EnCORETM 175171 ADAPTER 4-1/2" (114.3) TYP. 175052 FLASHING 175155 175155 175071 175055 175051 175155 1/4" INFILL 5/8" (15.9) 4-1/2" (114.3) TYP. 175077 175505 175075 175071 10 FEBRUARY, 2014 EC 97911-055 SCALE 3" = 1'-0" 175053 kawneer.com 175003 2 HORIZONTAL 2 HORIZONTAL 175021 3 SILL ADMC080 175007 175023 175171 ADAPTER 1 HEAD 175156 175156 175021 175007 175002 FLASHING 175156 175156 175156 175156 1/4" INFILL 175005 175156 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-055 175001 175027 175505 175025 175021 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. FEBRUARY, 2014 EnCORETM 11 4-1/2" SYSTEM - CENTER GLAZED (SCREW SPLINE) SCALE 3" = 1'-0" ELEVATION IS NUMBER KEYED TO DETAILS 1" INFILL 175001 1 HEAD 175003 175171 ADAPTER 2A HORIZONTAL W/ 1/4" ADAPTER 175001 175002 FLASHING 175504 3 SILL 175005 175156 175156 175156 175156 175156 4 JAMB 5 MULLION 4 JAMB 5 SPLIT MULLION 5A SPLIT MULLION W/ 1/4" ADAPTER 175155 175155 4 JAMB 5 MULLION ADMC080 1" INFILL 175101 175121 1-3/4" (44.5) TYP. 3 SILL 175100 1 HEAD 1 HEAD w/ caulk leg 175103 2 HORIZONTAL 2A HORIZONTAL W/ 1/4" ADAPTER 175101 175102 FLASHING 175504 1-3/4" (44.5) TYP. 175105 175155 175155 4 JAMB 5 SPLIT MULLION 175155 5A SPLIT MULLION W/ 1/4" ADAPTER kawneer.com © Kawneer Company, Inc., 2014 ELEVATION IS NUMBER KEYED TO DETAILS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 6" SYSTEM (SCREW SPLINE) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 175123 175107 175155 175155 175155 EnCORETM 175171 ADAPTER 2 HORIZONTAL 175155 175121 175107 175505 6" (152.4) TYP. 175155 1 HEAD 175105 175101 175102 FLASHING 175155 175155 1/4" INFILL 5/8" (15.9) 175127 6" (152.4) TYP. 3 SILL 5/8" (15.9) 175125 175121 175155 12 FEBRUARY, 2014 EC 97911-055 SCALE 3" = 1'-0" 175103 175171 ADAPTER EnCORETM FEBRUARY, 2014 EC 97911-055 3-9/16" SYSTEM (SHEAR BLOCK) NOTE: TYPE-B SYSTEM SIMILAR EXCEPT HEAD & SILL RUN THROUGH. SCALE 3" = 1'-0" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 13 ELEVATION IS NUMBER KEYED TO DETAILS 1/4" INFILL 1" INFILL 175155 175155 175155 175003 175021 175001 1 HEAD 1 HEAD 2 HORIZONTAL 175023 175155 175155 175003 175002 FLASHING 175504 2 HORIZONTAL 175171 ADAPTER 3 SILL 2A HORIZONTAL W/ 1/4" ADAPTER 175002 FLASHING 175171 ADAPTER 175001 175155 175155 175155 4 JAMB 5 MULLION 5A MULLION W/ 1/4" ADAPTER 175008 175008 175155 175155 4 JAMB 5 MULLION kawneer.com 6 SSG MULLION 6 SSG mullion 6a w/ 1/4" adapter inside seal ADMC080 175008 175171 ADAPTER 175028 175171 ADAPTER 175027 3 SILL 175023 175505 175003 175003 175155 175021 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 175155 175001 6A W/ 1/4" ADAPTER outside seal EnCORETM FEBRUARY, 2014 4-1/2" SYSTEM (SHEAR BLOCK) SCALE 3" = 1'-0" EC 97911-055 ELEVATION IS NUMBER KEYED TO DETAILS 1/4" INFILL 1" INFILL 175155 175155 175155 175053 175071 175051 1 HEAD 1 HEAD 175073 2 HORIZONTAL 175171 ADAPTER 3 SILL 2 HORIZONTAL 2A HORIZONTAL W/ 1/4" ADAPTER 175071 175171 ADAPTER 175053 175051 175505 3 SILL 175155 175155 4 JAMB 5 MULLION 5A MULLION W/ 1/4" ADAPTER 175058 175058 175058 6 ssg mullion 6a w/ 1/4" adapter inside seal 6A W/ 1/4" ADAPTER outside seal 175171 ADAPTER 175073 175071 175078 175155 175155 4 JAMB 5 MULLION 6 SSG MULLION ADMC080 175171 ADAPTER 175155 175053 175052 FLASHING kawneer.com © Kawneer Company, Inc., 2014 175052 FLASHING 175155 175053 175155 175155 175051 175504 175155 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. NOTE: TYPE-B SYSTEM SIMILAR EXCEPT HEAD & SILL RUN THROUGH. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 14 EnCORETM FEBRUARY, 2014 EC 97911-055 4-1/2" SYSTEM - CENTER GLAZED (SHEAR BLOCK) SCALE 3" = 1'-0" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 15 NOTE: TYPE-B SYSTEM SIMILAR EXCEPT HEAD & SILL RUN THROUGH. ELEVATION IS NUMBER KEYED TO DETAILS 1/4" INFILL 1" INFILL 175156 175156 175156 175003 175001 175021 1 HEAD 1 HEAD 2 HORIZONTAL 175023 175156 175156 175156 175002 FLASHING 175171 ADAPTER 175504 2 HORIZONTAL 3 SILL 2A HORIZONTAL W/ 1/4" ADAPTER 175003 175156 175156 175156 4 JAMB 5 MULLION 5A MULLION W/ 1/4" ADAPTER 175008 175008 175008 6 SSG MULLION 6A W/ 1/4" ADAPTER INSIDE SEAL 6A W/ 1/4" ADAPTER OUTSIDE SEAL 175171 ADAPTER 175023 175028 175021 175171 ADAPTER 3 SILL 175156 175156 4 JAMB 5 MULLION kawneer.com 6 SSG MULLION ADMC080 175171 ADAPTER 175505 175001 175002 FLASHING 175003 175152 175021 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 175003 175001 EnCORETM FEBRUARY, 2014 6" SYSTEM (SHEAR BLOCK) EC 97911-055 ELEVATION IS NUMBER KEYED TO DETAILS 1/4" INFILL 1" INFILL 175155 175101 175121 1 HEAD 1 HEAD 2 HORIZONTAL 175101 175155 175155 175103 175155 175123 175102 FLASHING 175171 ADAPTER 175504 2 HORIZONTAL 175103 175101 175103 175121 175155 2A HORIZONTAL W/ 1/4" ADAPTER 3 SILL 175171 ADAPTER 175102 FLASHING 175505 3 SILL 175155 175155 4 JAMB 5 MULLION 5A MULLION W/ 1/4" ADAPTER 175108 175108 175108 175155 175155 4 JAMB 5 MULLION 6 SSG MULLION 6 SSG MULLION 6A W/ 1/4" ADAPTER INSIDE SEAL 6A W/ 1/4" ADAPTER OUTSIDE SEAL ADMC080 175171 ADAPTER 175155 175171 ADAPTER 175123 175121 175128 kawneer.com © Kawneer Company, Inc., 2014 175155 175155 175103 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. NOTE: TYPE-B SYSTEM SIMILAR EXCEPT HEAD & SILL RUN THROUGH. SCALE 3" = 1'-0" Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 16 175129 kawneer.com 175029 4-1/2" SYSTEM center glazed 175155 ADMC080 175009 175156 175156 175079 4-1/2" SYSTEM 175059 175155 175155 175029 3-9/16" SYSTEM 175009 175155 175155 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-055 1/4" INFILL 175029 175155 175079 175155 175029 175156 175129 6" SYSTEM 175109 175155 175155 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. FEBRUARY, 2014 EnCORETM 175155 17 90° OUTSIDE CORNERS SCALE 3" = 1'-0" 1" INFILL 175009 175155 175059 175155 175009 175156 175109 175155 175155 175156 175156 175059 175155 175155 175009 175029 1/4" INFILL 175155 3-9/16" SYSTEM 175155 175029 175009 4-1/2" SYSTEM 175155 175155 175079 175156 175029 175155 175129 ADMC080 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 175155 175155 175079 90° INSIDE CORNERS 4-1/2" SYSTEM center glazed 175156 175009 6" SYSTEM 175155 175109 kawneer.com © Kawneer Company, Inc., 2014 175009 175029 EnCORETM Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 175109 175129 18 FEBRUARY, 2014 EC 97911-055 SCALE 3" = 1'-0" 1" INFILL 175059 55 51 17 55 51 17 6" SYSTEM 175155 ADMC080 175109 09 51 17 29 51 17 175129 4-1/2" SYSTEM center glazed 56 51 17 56 51 17 175009 175029 09 50 17 29 50 17 © Kawneer Company, Inc., 2014 4-1/2" SYSTEM 55 51 17 55 51 17 175059 175079 59 50 17 3-9/16" SYSTEM 55 51 17 55 51 17 175009 175029 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 09 50 79 50 17 kawneer.com 17 29 50 17 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. FEBRUARY, 2014 EnCORETM EC 97911-055 135° OUTSIDE CORNERS SCALE 3" = 1'-0" 1/4" INFILL 1" INFILL 175155 175155 175155 175155 175156 175156 175155 19 29 50 17 175155 55 51 17 5 5 51 17 ADMC080 09 50 4-1/2" SYSTEM center glazed 17 175009 09 3-9/16" SYSTEM 50 17 175009 1/4" INFILL 175155 4-1/2" SYSTEM 175155 175155 175155 6" SYSTEM 175155 kawneer.com © Kawneer Company, Inc., 2014 175059 29 50 17 175029 135° INSIDE CORNERS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 59 50 17 79 50 17 175079 EnCORETM Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 09 51 17 175109 55 51 17 55 51 17 17 51 29 55 51 17 55 51 175029 4-1/2" (114.3) 55 51 5/8" (15.9) 175155 17 55 51 17 1-3/4" (44.5) 17 175129 20 FEBRUARY, 2014 EC 97911-055 SCALE 3" = 1'-0" 1" INFILL 175155 EnCORETM FEBRUARY, 2014 EC 97911-055 MISCELLANEOUS FRAMING SCALE 3" = 1'-0" 1-1/4" narrow perimeter 1-1/4" narrow perimeter Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. screw spline system with 1/4" infill screw spline system with 1" infill 175011 175031 175157 3-9/16" SYSTEM 175012 175507 175061 175081 175157 4-1/2" SYSTEM 175062 175157 175507 175062 175506 175031 175158 4-1/2" SYSTEM center glazed 175012 175011 175158 175507 175012 175506 175131 175157 175111 6" SYSTEM 175112 175157 175507 175112 175506 heavy mullions 279505 279500 279500 279502 3-9/16" non-thermal 175004 (IN LIEU OF 175003) 175054 (IN LIEU OF 175053) 3-9/16" thermal 279506 279500 279500 279503 4-1/2" non-thermal 175104 (IN LIEU OF 175103) 279507 279501 6" non-thermal 175006 (IN LIEU OF 175005) 4-1/2" thermal 279504 279501 © Kawneer Company, Inc., 2014 175012 175506 head receptors Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 175157 175056 (IN LIEU OF 175055) 6" thermal 175106 (IN LIEU OF 175105) NOTE: HEAVY MULLIONS CAN BE USED WITH STANDARD FACE COVERS 175155 & 175156 kawneer.com ADMC080 21 22 EnCORETM FEBRUARY, 2014 MISCELLANEOUS FRAMING / GLAZING CHART EC 97911-055 SCALE 3" = 1'-0" HORIZONTAL / CROSSRAIL ASSEMBLY (SCREW SPLINE SYSTEM) 175029 175009 EnCORETM GLAZING CHART 1/2" INFILL ADAPTER (SHOWN WITH 3-9/16" DEEP SYSTEM) INFILL THICKNESS ADAPTER for 1" Infill Pocket WEATHERING (Both Sides) 1/8" 175171 027077 Heavy 1/4" 175171 027074 Standard 3/8" 175171 027076 Light 1/2" 175173 027074 Standard 5/8" 175173 027076 Light 3/4" 175175 027074 Standard 7/8" – 027077 Heavy 1" – 027074 Standard 1-1/8" – 027076 Light 175173 ADAPTER HEAD 175173 ADAPTER 175173 ADAPTER 175173 ADAPTER HORIZONTAL MULLION 175109 175059 175155 175156 175129 175079 175155 BRAKE METAL NOTE: For infill thicknesses in 1/16" increments or oversize glass, use a combination of the Std. (027074) with either the Light (27076) or the Heavy (027077) gaskets. SSG GLAZING CHART INFILL THICKNESS SSG ADAPTER HORIZONTAL WEATHERING SSG WEATHERING 1/4" 175172 027074 Std. 175302 1/2" 175173 027074 Std. 175302 ADMC080 kawneer.com © Kawneer Company, Inc., 2014 175059 175155 175156 175129 175079 175155 175156 175156 BRAKE METAL 175109 175009 175029 JAMB Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1" INFILL Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1/4" INFILL EnCORETM FEBRUARY, 2014 EC 97911-055 23 GLASSventTM FOR STOREFRONT SCALE 3" = 1'-0" PROJECT-OUT 1 1 5 175051 175053 6 2 3 3 452132 452132 7 8 4 ELEVATION IS NUMBER KEYED TO DETAILS 452132 452132 2 4 175053 175051 452132 175155 © Kawneer Company, Inc., 2014 5 452132 175155 175051 OUTSWING CASEMENT Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 175155 175155 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OUTSWING CASEMENT PROJECT-OUT 175053 175053 175155 175155 6 175053 452132 7 NOTE: Bronze spacer is recommended when 1" insulating glass is used. MAXIMUM / MINIMUM SIZES (1" INFILL) PROJECT-OUT MAXIMUM 60" x 36" MINIMUM 14" x 14" OUTSWING CASEMENT MAXIMUM 36" x 60" MINIMUM 14" x 14" kawneer.com 175052 ADMC080 452132 175155 8 EnCORETM GLASSvent TM FEBRUARY, 2014 FOR STOREFRONT EC 97911-055 PROJECT - OUT OUTSWING CASEMENT Stainless steel 4-bar hinge STANDARD STANDARD Cast white bronze cam lock STANDARD STANDARD Cast white bronze cam lock with pole ring OPTIONAL OPTIONAL Cast white bronze custodial lock with removable handle OPTIONAL OPTIONAL Cast white bronze concealed lock with removable hex key OPTIONAL OPTIONAL Cast white bronze pole/pull ring OPTIONAL Pivot-shoe roto-operator OPTIONAL Multi-point lock with cast white bronze locking handle OPTIONAL Insect screen CAM LOCK OPTIONAL CAM LOCK WITH POLE RING PULL RING REMOVABLE HANDLE PIVOT-SHOE ROTO-OPERATOR CONCEALED LOCK INSECT SCREEN WITH STANDARD WICKET ADMC080 OPTIONAL ACCESS CONTROL LOCK STAINLESS STEEL 4 BAR HINGES INSECT SCREEN WITH FULL WICKET kawneer.com © Kawneer Company, Inc., 2014 DESCRIPTION Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. GLASSventTM FOR STOREFRONT HARDWARE SELECTION GUIDE Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 24 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FEBRUARY, 2014 1 2 kawneer.com EnCORETM EC 97911-055 VENTS SCALE 3" = 1'-0" 175053 175155 8225TL IsoLockTM WINDOW SHOWN 175155 NOTE: Other vent types can be accommodated. Consult your Kawneer Representative for other options. 175174 VENT ADAPTER 1 3 175174 VENT ADAPTER 175053 175174 VENT ADAPTER 175174 VENT ADAPTER 3 ADMC080 4 2 ELEVATION IS NUMBER KEYED TO DETAILS 175155 175053 175053 175155 4 25 EnCORETM FEBRUARY, 2014 4-1/2" ENTRANCE FRAMING (FRONT GLAZED) SCALE 3" = 1'-0" EC 97911-055 EnCORETM FRAMING INCORPORATING KAWNEER "190" DOORS. 175155 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. NOTE: Other types of Kawneer doors may be used with this framing. See the Entrance Section for additional information. 175051 1 TRANSOM HEAD ELEVATION IS NUMBER KEYED TO DETAILS 175251 STOPS 175251 STOPS 175251 STOPS 175206 175221 175653 041045 2 OFFSET PIVOT/ BUTT HUNG TRANSOM BAR 2 S/A OFFSET ARM OFFSET PIVOT/ BUTT HUNG TRANSOM BAR 2 C.O.C. CENTER PIVOT TRANSOM BAR 175206 175221 175653 450500 TRAY 041045 3 OFFSET PIVOT/ BUTT HUNG HEADER 3 S/A OFFSET ARM OFFSET PIVOT/ BUTT HUNG HEADER ADMC080 3 C.O.C. CENTER PIVOT HEADER kawneer.com © Kawneer Company, Inc., 2014 450500 TRAY Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 26 EnCORETM FEBRUARY, 2014 EC 97911-055 27 4-1/2" ENTRANCE FRAMING (FRONT GLAZED) SCALE 3" = 1'-0" Transom area for both double or single acting doors with glass surround. Jambs above transom area are routed out to accept pocket insert 175253. 175253 POCKET INSERT 175155 4 DOOR JAMB AT TRANSOM 175642 175058 175058 175273 175273 175053 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 175232 or 175242 4 DOOR JAMB AT TRANSOM (OPTIONAL) 5 SINGLE ACTING SSG DOOR JAMB W/ DOOR ADAPTER 5 DOUBLE ACTING SSG DOOR JAMB W/ DOOR ADAPTER 175053 175232 175053 5 SINGLE ACTING DOOR JAMB 5 DOUBLE ACTING DOOR JAMB 175642 175232 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 175233 175643 5 SINGLE ACTING DOOR JAMB W/ DOOR ADAPTER 5 DOUBLE ACTING DOOR JAMB W/ DOOR ADAPTER 175051 175051 HOLE PLUG 175164 175164 HOLE PLUG 175643 6 SINGLE ACTING DOOR JAMB kawneer.com 6 DOUBLE ACTING DOOR JAMB 6 SINGLE ACTING DOOR JAMB W/ DOOR ADAPTER ADMC080 175233 6 DOUBLE ACTING DOOR JAMB W/ DOOR ADAPTER EnCORETM FEBRUARY, 2014 4-1/2" ENTRANCE FRAMING (CENTER GLAZED) SCALE 3" = 1'-0" EC 97911-055 EnCORETM FRAMING INCORPORATING KAWNEER "190" DOORS. 175156 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. NOTE: Other types of Kawneer doors may be used with this framing. See the Entrance Section for additional information. 175001 1 TRANSOM HEAD ELEVATION IS NUMBER KEYED TO DETAILS 175251 STOP 175251 STOP 175252 STOP 175252 STOP 175251 STOP 175206 175221 175653 450500 TRAY 041045 2 OFFSET PIVOT/ BUTT HUNG TRANSOM BAR 2 S/A OFFSET ARM OFFSET PIVOT/ BUTT HUNG TRANSOM BAR 2 C.O.C. CENTER PIVOT TRANSOM BAR 175206 175221 175653 450500 TRAY 041045 3 OFFSET PIVOT/ BUTT HUNG HEADER 3 S/A OFFSET ARM OFFSET PIVOT/ BUTT HUNG HEADER ADMC080 3 C.O.C. CENTER PIVOT HEADER kawneer.com © Kawneer Company, Inc., 2014 175252 STOP Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 28 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FEBRUARY, 2014 kawneer.com EnCORETM EC 97911-055 4-1/2" ENTRANCE FRAMING (CENTER GLAZED) SCALE 3" = 1'-0" Transom area for both double or single acting doors with glass surround. Jambs above transom area are routed out to accept pocket insert 175253. 175231 or 175641 175253 POCKET INSERT 4 DOOR JAMB AT TRANSOM 175641 175231 5 SINGLE ACTING DOOR JAMB 5 DOUBLE ACTING DOOR JAMB 175641 175231 6 SINGLE ACTING DOOR JAMB 6 DOUBLE ACTING DOOR JAMB ADMC080 29 EnCORETM 30 FEBRUARY, 2014 6" ENTRANCE FRAMING (FRONT GLAZED) SCALE 3" = 1'-0" EC 97911-055 EnCORETM FRAMING INCORPORATING KAWNEER "190" DOORS. 175155 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. NOTE: Other types of Kawneer doors may be used with this framing. See the Entrance Section for additional information. 175101 1 TRANSOM HEAD ELEVATION IS NUMBER KEYED TO DETAILS 175251 STOPS 175251 STOPS 175251 STOPS 175207 450500 TRAY 041045 2 OFFSET PIVOT/ BUTT HUNG TRANSOM BAR 2 S/A OFFSET ARM OFFSET PIVOT/ BUTT HUNG TRANSOM BAR 2 C.O.C. CENTER PIVOT TRANSOM BAR 175207 175222 175654 450500 TRAY 041045 3 OFFSET PIVOT/ BUTT HUNG HEADER 3 S/A OFFSET ARM OFFSET PIVOT/ BUTT HUNG HEADER ADMC080 3 C.O.C. CENTER PIVOT HEADER kawneer.com © Kawneer Company, Inc., 2014 175222 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 175654 EnCORETM FEBRUARY, 2014 EC 97911-055 6" ENTRANCE FRAMING (FRONT GLAZED) SCALE 3" = 1'-0" 175108 175273 175273 175103 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 175155 4 DOOR JAMB AT TRANSOM 5 SINGLE ACTING SSG DOOR JAMB W/ DOOR ADAPTER 5 DOUBLE ACTING SSG DOOR JAMB W/ DOOR ADAPTER 175103 175103 175233 175643 5 SINGLE ACTING DOOR JAMB W/ DOOR ADAPTER 5 DOUBLE ACTING DOOR JAMB W/ DOOR ADAPTER 175101 175101 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 175108 HOLE PLUG 175164 175164 HOLE PLUG 175643 6 SINGLE ACTING DOOR JAMB W/ DOOR ADAPTER kawneer.com ADMC080 175233 6 DOUBLE ACTING DOOR JAMB W/ DOOR ADAPTER 31 EnCORETM FEBRUARY, 2014 ENTRANCE FRAMING OPTIONS SCALE 3" = 1'-0" EC 97911-055 175640 060148 SINGLE ACTING DOOR JAMB DOUBLE ACTING DOOR JAMB 175058 175053 175053 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. COMMON DOOR JAMBS HOLE PLUG 175274 175234 SINGLE ACTING DOOR JAMB W/ DOOR ADAPTER DOUBLE ACTING DOOR JAMB W/ DOOR ADAPTER SINGLE ACTING SSG DOOR JAMB W/ DOOR ADAPTER 175103 175103 175108 HOLE PLUG 175644 175234 SINGLE ACTING DOOR JAMB W/ DOOR ADAPTER DOUBLE ACTING DOOR JAMB W/ DOOR ADAPTER ADMC080 HOLE PLUG 175274 SINGLE ACTING SSG DOOR JAMB W/ DOOR ADAPTER kawneer.com © Kawneer Company, Inc., 2014 HOLE PLUG 175644 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 32 EnCORETM FEBRUARY, 2014 EC 97911-055 33 WINDLOAD CHARTS WITH HORIZONTALS 1 1.5 (720 Pa) B = 20 PSF (960 Pa) WITHOUT HORIZONTALS WIDTH IN METERS D = 30 PSF (1440 Pa) 2 .5 E = 40 PSF (1920 Pa) 15 12 7 2 6 A 1.5 B C D 1 E 5 4 HEIGHT IN FEET 2.5 8 175003 175007 9 3 4 5 6 7 2.5 8 7 A 2 B C D 1.5 E 6 175155 5 175156 175156 4 1 I = 0.564 (23.48 x 10 ) S = 0.326 (5.34 x 103) 2 1 8 .5 1 2 6 7 8 WITHOUT HORIZONTALS WIDTH IN METERS 2 .5 175007 175006 14 4 13 12 9 2.5 8 7 2 6 A B 1.5 C D E 1 5 4 3 2 .5 2 3 4 5 6 WIDTH IN FEET 7 8 4 13 3.5 11 175155 175155 175156 175156 175004 175023 HEIGHT IN FEET 3 2 12 HEIGHT IN METERS 10 1.5 14 3.5 11 1 15 175027 1.5 175025 1 15 HEIGHT IN FEET 5 WITH HORIZONTALS .5 © Kawneer Company, Inc., 2014 4 WIDTH IN FEET WIDTH IN METERS 1 3 WIDTH IN FEET 10 3 9 2.5 8 7 A B C D E 1.5 6 5 4 1 3 175155 175155 2 175156 175156 1 I = 0.792 (32.96 x 104) S = 0.465 (7.62 x 103) ADMC080 .5 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 1 3 9 3 .5 2 10 175155 4 2 3.5 11 175005 3 HEIGHT IN METERS 10 4 13 3.5 11 kawneer.com 2 HEIGHT IN METERS 12 1 1.5 14 4 13 1 1 15 14 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. A = 15 PSF C = 25 PSF (1200 Pa) WIDTH IN METERS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L\175 up to 13'-6" and L\240 + 1/4" above 13'-6". These curves are for mullions WITH and WITHOUT HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM (assuming full lateral buckling support) 15,152 psi (104 MPa), FORMED STEEL 30,000 P.S.I. (207 MPa), STEEL BAR 20,000 psi (138 MPa). Charted curves, in all cases, are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. EnCORETM FEBRUARY, 2014 WINDLOAD CHARTS EC 97911-055 WITHOUT HORIZONTALS 2 WIDTH IN METERS .5 E = 40 PSF (1920 Pa) 15 14 12 9 2.5 8 7 2 6 A B 1.5 C D E 1 5 4 3 2 175008 175028 HEIGHT IN FEET 3 2 3 4 5 6 7 10 3 9 2.5 8 7 A 2 B C D 1.5 E 6 5 4 I = 0.654 (27.22 x 104) S = 0.466 (7.64 x 103) 1 3 2 .5 1 3.5 11 HEIGHT IN METERS 1 8 .5 1 2 3 4 5 6 7 8 WIDTH IN FEET WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 WIDTH IN METERS 2 .5 15 1 1.5 2 15 14 14 4 3 9 2.5 8 7 A 2 B C 1.5 D E 6 5 4 175155 175155 175156 175156 2 .5 1 2 3 4 5 6 7 10 3 9 6 2.5 A B C D2 E 5 1.5 8 7 4 1 3 3.5 11 HEIGHT IN FEET 10 HEIGHT IN METERS 11 12 175053 3.5 175057 12 4 13 175055 13 HEIGHT IN METERS HEIGHT IN FEET 10 4 13 3.5 11 HEIGHT IN FEET 2 HEIGHT IN METERS 12 1 1.5 14 4 13 1 1 15 I = 1.277 (53.15 x 104) S = 0.639 (10.47 x 103) 2 1 8 WIDTH IN FEET 1 3 .5 1 2 3 4 5 6 7 8 WIDTH IN FEET ADMC080 kawneer.com © Kawneer Company, Inc., 2014 (960 Pa) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1.5 B = 20 PSF D = 30 PSF (1440 Pa) WIDTH IN METERS 1 (720 Pa) C = 25 PSF (1200 Pa) WITH HORIZONTALS .5 A = 15 PSF Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 34 EnCORETM FEBRUARY, 2014 EC 97911-055 WINDLOAD CHARTS B = 20 PSF (960 Pa) WITHOUT HORIZONTALS 2 WIDTH IN METERS .5 E = 40 PSF (1920 Pa) 15 12 2.5 8 A B2 C D E 1.5 7 6 5 2 3 4 5 6 7 8 7 A B C 6 D E 2 1 8 .5 1 2 3 4 5 6 7 8 WIDTH IN FEET WIDTH IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS .5 1 1.5 WIDTH IN METERS 2 .5 15 1 1.5 2 175077 14 12 3 9 2.5 A B 2 C D E 1.5 8 7 6 5 3.5 11 175155 175155 175156 175156 175054 175073 HEIGHT IN FEET 10 HEIGHT IN METERS 3.5 11 4 13 10 3 9 A 2.5 B C D 2 E 8 7 6 5 4 1.5 4 1 3 2 2 .5 1 2 3 4 5 6 WIDTH IN FEET 7 8 1 3 175155 175156 175155 175156 I = 1.747 (72.72 x 104) S = 0.877 (14.37 x 103) ADMC080 1 .5 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 12 175075 4 13 175057 175056 15 14 HEIGHT IN FEET 1 1.5 WIDTH IN METERS © Kawneer Company, Inc., 2014 2.5 2 3 .5 1 3 9 4 I = 1.511 (62.89 x 104) S = 0.745 (12.21 x 103) 1 2 10 5 4 3 3.5 11 175078 HEIGHT IN FEET 3 9 175058 HEIGHT IN METERS 10 4 13 3.5 11 kawneer.com 2 HEIGHT IN METERS 12 1 1.5 14 4 13 1 1 15 14 HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1.5 (720 Pa) D = 30 PSF (1440 Pa) WIDTH IN METERS 1 A = 15 PSF C = 25 PSF (1200 Pa) WITH HORIZONTALS .5 35 EnCORETM FEBRUARY, 2014 WINDLOAD CHARTS EC 97911-055 WIDTH IN METERS D = 30 PSF (1440 Pa) 2 15 .5 12 C D2 7 6 E 5 HEIGHT IN FEET B 2.5 8 175103 175107 9 3 1 2 8 7 2 6 1.5 .5 4 5 6 7 1.5 2 1 .5 1 2 I = 3.229 (134.40 x 104) S = 1.094 (17.93 x 103) 175106 WIDTH IN METERS 1 175156 8 WITH HORIZONTALS .5 175156 2 3 4 5 6 7 8 WIDTH IN FEET WITHOUT HORIZONTALS WIDTH IN METERS 175127 3 175155 175125 2 175155 175107 1 1 3 WIDTH IN FEET .5 15 1 1.5 2 15 14 4 13 12 12 7 E 9 6 5 2 175155 175155 175156 175156 175104 175123 HEIGHT IN FEET 8 A 3 B C 2.5 D 10 HEIGHT IN METERS 3.5 11 4 13 A 10 B3 C D E 2.5 9 8 7 2 6 5 1.5 4 3.5 11 HEIGHT IN METERS 14 HEIGHT IN FEET 9 4 3 1.5 4 1 3 2 1 A3 B C 2.5 D E 10 5 1.5 4 1 3.5 11 175105 A 4 12 HEIGHT IN METERS 10 2 13 3.5 11 1.5 14 4 13 1 15 E = 40 PSF (1920 Pa) 14 HEIGHT IN FEET WITHOUT HORIZONTALS 2 .5 1 2 3 4 5 6 WIDTH IN FEET 7 1 3 1 8 175155 175155 175156 175156 .5 1 2 3 4 5 6 7 8 WIDTH IN FEET I = 4.325 (180.02 x 104) S = 1.626 (26.65 x 103) ADMC080 kawneer.com © Kawneer Company, Inc., 2014 1.5 (960 Pa) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 B = 20 PSF C = 25 PSF (1200 Pa) WIDTH IN METERS .5 (720 Pa) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. WITH HORIZONTALS A = 15 PSF HEIGHT IN METERS 36 EnCORETM FEBRUARY, 2014 EC 97911-055 WINDLOAD CHARTS (960 Pa) WITHOUT HORIZONTALS WIDTH IN METERS .5 12 2.5 8 7 C 6 D 5 E 4 2 175108 175128 2 2 3 4 5 6 7 10 9 2.5 8 7 C 6 D E 4 2 1 8 1 2 1.5 .5 175641 175642 8 1 1.5 2 12 3 9 A B 2.5 8 C D 7 E 6 5 2 3.5 11 175231 175232 HEIGHT IN FEET 10 HEIGHT IN METERS 3.5 11 4 13 A3 B C 2.5 D E 10 9 8 7 2 6 5 1.5 4 1.5 4 1 3 2 2 .5 1 2 3 4 5 6 WIDTH IN FEET 7 1 3 1 8 I = 2.919 (121.50 x 104) S = 1.297 (21.25 x 103) ADMC080 .5 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 12 HEIGHT IN FEET 7 14 4 13 © Kawneer Company, Inc., 2014 6 15 14 kawneer.com 5 WIDTH IN METERS 2 15 1 4 WITHOUT HORIZONTALS WIDTH IN METERS 1 3 WIDTH IN FEET WITH HORIZONTALS .5 1.5 .5 I = 4.005 (166.70 x 104) S = 1.533 (25.12 x 103) WIDTH IN FEET 2 1 3 .5 1 A B3 5 1.5 1 3 3.5 11 HEIGHT IN FEET B 9 4 12 HEIGHT IN METERS A3 10 2 13 3.5 11 1.5 14 4 13 1 15 E = 40 PSF (1920 Pa) 14 1 B = 20 PSF D = 30 PSF (1440 Pa) 2 15 HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1.5 (720 Pa) C = 25 PSF (1200 Pa) WIDTH IN METERS 1 A = 15 PSF HEIGHT IN METERS WITH HORIZONTALS .5 37 1 1 2 1 3 1.5 4 5 2 15 14 13 12 11 10 9 3 A 8 7 B C D 6 E 5 3 2 WIDTH IN FEET 6 7 2.5 2 (720 Pa) B = 20 PSF (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) 175640 4 1.5 1 .5 8 I = 2.799 (116.50 x 104) S = 1.233 (20.21 x 103) ADMC080 .5 E = 40 PSF (1920 Pa) 15 4 3.5 1 1 2 1 3 1.5 4 5 2 14 13 4 12 11 3.5 10 9 8 7 3 A B C 2.5 D E 6 2 5 4 1.5 3 1 2 .5 6 7 8 WIDTH IN FEET kawneer.com © Kawneer Company, Inc., 2014 WINDLOAD CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EnCORETM HEIGHT IN METERS WIDTH IN METERS A = 15 PSF HEIGHT IN FEET .5 HEIGHT IN METERS WITH HORIZONTALS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. HEIGHT IN FEET 38 FEBRUARY, 2014 EC 97911-055 WITHOUT HORIZONTALS WIDTH IN METERS EnCORETM FEBRUARY, 2014 EC 97911-055 WINDLOAD CHARTS B = 20 PSF (960 Pa) 2 WITHOUT HORIZONTALS WIDTH IN METERS .5 E = 40 PSF (1920 Pa) 15 D 9 8 E 7 2.5 2 6 5 1.5 4 1 3 175155 175156 175155 175156 2 .5 1 2 3 4 5 6 WIDTH IN FEET 7 8 A 12 B 3.5 C D 3 E 10 9 2.5 8 7 2 6 5 1.5 4 1 3 I = 4.005 (166.70 x 10 ) S = 1.533 (25.12 x 103) 4 WITH 1/2" x 3-1/4" STEEL BAR I = 1.430 (59.49 x 104) S = 0.880 (14.43 x 103) ADMC080 4 13 11 HEIGHT IN FEET C3 10 175105 11 3.5 HEIGHT IN METERS B 175107 A 12 HEIGHT IN FEET 2 14 175103 4 13 kawneer.com 1.5 2 1 .5 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS 14 1 1 15 © Kawneer Company, Inc., 2014 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1.5 (720 Pa) D = 30 PSF (1440 Pa) WIDTH IN METERS 1 A = 15 PSF C = 25 PSF (1200 Pa) WITH HORIZONTALS .5 39 EnCORETM 40 FEBRUARY, 2014 WINDLOAD CHARTS EC 97911-055 1.5 WIDTH IN METERS 2 .5 15 1.5 2 14 A 13 A 12 B 3.5 12 B 3.5 9 E 8 7 2.5 2 6 5 175155 175155 175156 175156 4 C D3 10 9 E 8 7 2.5 2 6 5 1.5 4 1.5 4 1 2 2 .5 1 2 3 4 5 6 WIDTH IN FEET 7 8 1 3 1 175155 175155 175156 175156 .5 1 2 3 4 5 6 7 8 WIDTH IN FEET I = 4.325 (180.02 x 104) S = 1.626 (26.65 x 103) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3 1 11 HEIGHT IN FEET 10 175123 C D3 175104 11 HEIGHT IN METERS 13 4 HEIGHT IN METERS 14 HEIGHT IN FEET 1 15 WITH 1/2" x 3-1/4" STEEL BAR I = 1.430 (59.49 x 104) S = 0.880 (14.43 x 103) ADMC080 kawneer.com © Kawneer Company, Inc., 2014 1 WITHOUT HORIZONTALS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. .5 175127 WIDTH IN METERS 175125 WITH HORIZONTALS 175107 175106 A = 15 PSF (720 Pa) B = 20 PSF (960 Pa) C = 25 PSF (1200 Pa) D = 30 PSF (1440 Pa) E = 40 PSF (1920 Pa) EnCORETM FEBRUARY, 2014 EC 97911-055 41 WINDLOAD CHARTS A = 15 PSF (720 Pa) B = 20 PSF (960 Pa) C = 25 PSF (1200 Pa) E = 40 PSF (1920 Pa) WITH HORIZONTALS WITHOUT HORIZONTALS WIDTH IN METERS .5 1 1.5 WIDTH IN METERS 2 .5 15 2 14 175128 A 13 A4 12 B 3.5 12 B 3 9 2.5 8 7 C 6 D 5 E 4 1.5 1 3 1 2 I = 4.005 (166.70 x 104) S = 1.533 (25.12 x 103) WITH 1/2" x 3-1/4" STEEL BAR I = 1.430 (59.49 x 104) S = 0.880 (14.43 x 103) .5 1 2 3 4 5 6 7 3.5 11 HEIGHT IN FEET 10 HEIGHT IN METERS 13 10 8 2.5 8 7 C 6 D 5 E 4 2 © Kawneer Company, Inc., 2014 1.5 .5 1 2 3 4 5 6 WIDTH IN FEET ADMC080 2 1 3 1 WIDTH IN FEET 3 9 7 8 HEIGHT IN METERS 175108 2 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1.5 4 11 kawneer.com 1 15 14 HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. D = 30 PSF (1440 Pa) EnCORETM 42 FEBRUARY, 2014 DEADLOAD CHARTS EC 97911-055 Horizontal or deadload limitations are based upon 1/8" (3.2) maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1/4" (6.4) and 1" (25.4) thick glass supported on two setting blocks placed at the loading points shown. A = 1/4 POINT LOADING 175003 175005 B = 1/6 POINT LOADING 175006 175004 WIDTH IN METERS 1.5 WIDTH IN METERS 1 2 10 3 2.5 8 7 2 6 5 1.5 4 HEIGHT IN FEET 9 1 3 2 C B A 1 2 3 4 5 6 7 3 9 2.5 8 7 2 6 5 1.5 4 1 3 2 .5 .5 1 0 8 1 2 WIDTH IN FEET 3 4 WIDTH IN METERS 2 1 1.5 2 13 12 12 3.5 11 10 10 7 2 6 5 1.5 4 HEIGHT IN FEET 2.5 8 HEIGHT IN METERS 3 9 1 3 1 1 2 3 4 5 6 7 3 9 2.5 8 7 2 6 5 1.5 4 1 3 C B A .5 2 3.5 11 2 C .5 B A 1 0 8 WIDTH IN FEET HEIGHT IN METERS 13 HEIGHT IN FEET 7 175025 WIDTH IN METERS 1.5 6 WIDTH IN FEET 175023 1 5 C B A 8 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 3.5 11 HEIGHT IN METERS HEIGHT IN FEET 12 3.5 10 0 2 HEIGHT IN METERS 12 11 0 1.5 13 13 1 2 3 4 5 6 7 8 WIDTH IN FEET ADMC080 kawneer.com © Kawneer Company, Inc., 2014 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. C = 1/8 POINT LOADING EnCORETM FEBRUARY, 2014 EC 97911-055 43 DEADLOAD CHARTS Horizontal or deadload limitations are based upon 1/8" (3.2) maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1/4" (6.4) and 1" (25.4) thick glass supported on two setting blocks placed at the loading points shown. A = 1/4 POINT LOADING 175053 175055 B = 1/6 POINT LOADING 175056 WIDTH IN METERS WIDTH IN METERS 1 1.5 2 1 12 10 3 2.5 8 7 2 6 5 1.5 4 HEIGHT IN FEET 9 1 3 2 1 2 3 4 5 6 7 3 9 2.5 8 7 2 6 5 1.5 4 1 3 2 C .5 B A 1 3.5 11 HEIGHT IN METERS HEIGHT IN FEET 10 .5 1 0 8 1 2 4 175073 1 1.5 2 7 1 1.5 2 13 12 12 3.5 11 10 10 3 2.5 8 7 2 6 5 1.5 4 C 3 B A 2 1 1 2 3 4 5 6 7 HEIGHT IN FEET 9 3.5 11 HEIGHT IN METERS HEIGHT IN FEET 6 WIDTH IN METERS 13 1 3 9 2.5 8 7 2 6 5 1.5 4 1 3 2 .5 C .5 B A 1 0 8 WIDTH IN FEET kawneer.com 5 175075 WIDTH IN METERS © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3 C B A 8 WIDTH IN FEET WIDTH IN FEET 0 2 12 3.5 11 0 1.5 13 HEIGHT IN METERS 13 1 2 3 4 5 6 WIDTH IN FEET ADMC080 7 8 HEIGHT IN METERS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. C = 1/8 POINT LOADING 175054 EnCORETM 44 FEBRUARY, 2014 DEADLOAD CHARTS EC 97911-055 Horizontal or deadload limitations are based upon 1/8" (3.2) maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1/4" (6.4) and 1" (25.4) thick glass supported on two setting blocks placed at the loading points shown. A = 1/4 POINT LOADING 175103 175105 B = 1/6 POINT LOADING WIDTH IN METERS 2 1 13 12 10 2 6 5 1.5 4 HEIGHT IN FEET 7 HEIGHT IN METERS 2.5 8 1 3 2 2 3 4 5 6 7 2.5 8 7 2 6 5 1.5 4 1 2 1 0 8 1 2 WIDTH IN FEET 3 4 WIDTH IN METERS 2 1 13 1.5 2 13 12 12 3.5 11 10 10 3 2.5 8 7 2 6 5 C 4 B 3 1.5 HEIGHT IN FEET 9 1 1 2 3 4 5 6 7 2.5 8 7 2 6 5 1.5 4 1 2 .5 1 3 9 3 A 2 3.5 11 HEIGHT IN METERS HEIGHT IN FEET 7 175125 WIDTH IN METERS 1.5 6 .5 WIDTH IN FEET 175123 1 5 C B A 8 C B .5 A 1 0 8 WIDTH IN FEET 1 2 3 4 5 6 7 8 WIDTH IN FEET ADMC080 kawneer.com © Kawneer Company, Inc., 2014 1 3 9 3 C B .5 A 1 3.5 11 3 9 0 2 12 3.5 10 HEIGHT IN FEET 1.5 13 11 0 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1.5 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 175106 WIDTH IN METERS 1 HEIGHT IN METERS 175104 HEIGHT IN METERS C = 1/8 POINT LOADING EnCORETM FEBRUARY, 2014 EC 97911-055 45 DEADLOAD CHARTS DEADLOADS ON ENTRANCE TRANSOM BARS Height limitations for transom glass over a doorway are based on a maximum 1/16" (1.6) mid-point deflection of a transom bar supporting glass bearing on two setting blocks placed at the loading points shown. B = 1/6 POINT LOADING 175221 WITH 1/4" GLASS 175653 175653 WIDTH IN METERS 1 1.5 WIDTH IN METERS 2 1 12 10 10 2 6 5 1.5 4 HEIGHT IN FEET 7 HEIGHT IN METERS 2.5 8 1 2 1 2 3 4 5 6 7 2 6 5 1.5 4 C B A 2 0 8 1 2 3 4 5 6 7 WIDTH IN FEET 175206 175206 WIDTH IN METERS WIDTH IN METERS 1 1.5 2 1 1 .5 8 WITH 1/4" GLASS 1.5 2 13 12 3.5 10 10 7 2 6 5 1.5 4 HEIGHT IN FEET 2.5 8 HEIGHT IN METERS 3 9 1 3 2 1 2 3 4 5 6 7 3 9 2.5 8 7 2 6 5 1.5 4 1 3 2 .5 1 3.5 11 C B A 1 C B A 8 0 WIDTH IN FEET 1 2 3 4 5 6 WIDTH IN FEET ADMC080 7 8 .5 HEIGHT IN METERS 12 11 HEIGHT IN FEET 7 1 13 © Kawneer Company, Inc., 2014 2.5 8 WIDTH IN FEET WITH 1" GLASS kawneer.com 3 9 3 C .5 B A 1 3.5 11 3 9 0 2 12 3.5 11 0 1.5 13 HEIGHT IN METERS 13 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 175221 C = 1/8 POINT LOADING WITH 1" GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 1/4 POINT LOADING 46 EnCORETM FEBRUARY, 2014 DEADLOAD CHARTS EC 97911-055 DEADLOADS ON ENTRANCE TRANSOM BARS Height limitations for transom glass over a doorway are based on a maximum 1/16" (1.6) mid-point deflection of a transom bar supporting glass bearing on two setting blocks placed at the loading points shown. 175222 C = 1/8 POINT LOADING WITH 1/4" GLASS WITH 1" GLASS 175654 WIDTH IN METERS WIDTH IN METERS 1 1.5 2 1 12 10 10 2 6 5 1.5 4 HEIGHT IN FEET 7 HEIGHT IN METERS 1 3 2 C B .5 A 1 1 2 3 4 5 6 7 2.5 8 7 2 6 5 1.5 4 C 3 B 2 A 1 0 8 1 2 3 4 5 6 7 WIDTH IN FEET WIDTH IN FEET 175207 175207 WIDTH IN METERS WIDTH IN METERS WITH 1" GLASS 1 1.5 2 1 13 1 .5 8 WITH 1/4" GLASS 1.5 2 13 12 12 3.5 11 10 10 3 2.5 8 7 2 6 5 1.5 4 HEIGHT IN FEET 9 1 3 2 C B A 1 1 2 3 4 5 6 7 3.5 11 HEIGHT IN METERS HEIGHT IN FEET 3 9 3 9 2.5 8 7 2 6 5 1.5 4 1 3 C B .5 A 2 .5 1 0 8 WIDTH IN FEET HEIGHT IN METERS HEIGHT IN FEET 2.5 8 3.5 11 3 9 0 2 12 3.5 11 0 1.5 13 HEIGHT IN METERS 13 1 2 3 4 5 6 7 8 WIDTH IN FEET ADMC080 kawneer.com © Kawneer Company, Inc., 2014 175654 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. B = 1/6 POINT LOADING 175222 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 1/4 POINT LOADING EnCORETM FEBRUARY, 2014 EC 97911-055 THERMAL CHARTS Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) 15'-8" F.W. 2'-0" D.L.O. 9'-6" F.H. 7'-0" D.L.O. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 5'-0" D.L.O. Example Glass U-value = 0.42 Btu/hr·ft2·°F Total Daylight Opening = 3(5' x 7') + 3(5'x2') = 135 ft2 Total Projected Area = (Total Daylight Opening + Total Area of Framing System) = 15'-8" x 9'-6" = 148.83 ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area) = (135 ÷ 148.83)100 = 91% System U-factor vs Percent of Glass Area 0.40 0.30 Percent of Glass Based on 91% glass and center of glass U-factor of 0.42, System U-factor is equal to 0.49 Btu/hr·ft2·°F kawneer.com ADMC080 70 75 80 85 0.20 90 91% 95 0.50 0.49 E PL © Kawneer Company, Inc., 2014 M A COG U-factor 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.60 System U-factor Btu/hr·ft2·°F 0.70 EX Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.80 47 COG U-factor 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 System U-factor vs Percent of Glass Area Vision Area / Total Area (%) ADMC080 kawneer.com © Kawneer Company, Inc., 2014 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EnCORETM Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System U-Factor (Btu/h·ft2·°F) 48 FEBRUARY, 2014 EC 97911-055 Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.45 0.40 0.35 kawneer.com System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FEBRUARY, 2014 EnCORETM EC 97911-055 0.30 0.25 0.20 0.15 0.10 0.05 Charts are generated per AAMA 507. ADMC080 49 THERMAL CHARTS System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Vision Area / Total Area (%) COG SHGC 0.75 0.70 0.65 0.60 0.55 0.50 0.30 0.25 0.20 0.15 0.10 0.05 Charts are generated per AAMA 507. THERMAL CHARTS Vision Ares / Total Area (%) COG VT 0.75 0.70 0.65 0.60 0.55 0.50 0.40 0.35 ADMC080 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EnCORETM kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.45 System VT 50 FEBRUARY, 2014 EC 97911-055 System Visible Transmittance (VT) vs Percent of Vision Area EnCORETM FEBRUARY, 2014 EC 97911-055 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.61 0.46 0.59 0.44 0.58 0.42 0.56 0.40 0.55 0.38 0.53 0.36 0.51 0.34 0.50 0.32 0.48 0.30 0.46 0.28 0.45 0.26 0.43 0.24 0.42 0.22 0.40 0.20 0.38 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.68 0.75 0.67 0.70 0.64 0.70 0.63 0.65 0.59 0.65 0.58 0.60 0.55 0.60 0.54 0.55 0.50 0.55 0.49 0.50 0.46 0.50 0.45 0.45 0.41 0.45 0.40 0.40 0.37 0.40 0.36 0.35 0.33 0.35 0.31 0.30 0.28 0.30 0.27 0.25 0.24 0.25 0.22 0.20 0.19 0.20 0.18 0.15 0.15 0.15 0.13 0.10 0.10 0.10 0.09 0.05 0.06 0.05 0.04 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SHGC Matrix 2 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). kawneer.com ADMC080 51 52 EnCORETM FEBRUARY, 2014 GLAZING CLIP CHART EC 97911-055 Locate the largest lite of glass on each ELEVATION. Determine the width and height for the largest glass lite. Use the smallest of the two dimensions for the MODULE (FT) spacing. Match that Module (ft) spacing with the required wind load on the chart below. SAMPLE CALCULATION Lite "W" 3'-0" x 5'-3-1/2" 3'-0" 12" O.C. for 30 PSF 10" O.C. for 35 PSF 60 55 50 45 A = 6" O.C. B = 7" O.C. C = 8" O.C. D = 9" O.C. E = 10" O.C. F = 12" O.C. 40 35 30 15 2 3 4 5 F 6 E7 D A B C 8 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 20 MODULE (FT) 3'-0" Y Y W Y Y X SAMPLE ELEVATION ADMC080 kawneer.com © Kawneer Company, Inc., 2014 25 5'-3-1/2" WIND LOAD (PSF) STEP 1: STEP 2: STEP 3: STEP 4: Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Clip spacing of each elevation must be checked to meet wind load requirements. Glazing clips should be located 3" from each end of member and subsequently spaced per formula below: