Datasheet

SIDACtor ® Protection Thyristors
SLIC Protection
Battrax® Series Positive/Negative - Modified DO-214
Pb e3
RoHS
Description
The Battrax® series offers programmable SIDACtor®
overvoltage protection devices for SLIC applications.
This series is offered in a negative Battrax version and a
positive Battrax version. The B1xx0C_ is for a -VREF supply
and the B2050C_ is for a +VREF supply. Designed using
an SCR and a gate diode, the B1xx0C_ Battrax begins
to conduct at |-VREF| + |-1.2 V| while the B2050C_ Battrax
begins to conduct at |+VREF| + |1.2 V|.
Features and Benefits
• Low voltage overshoot
Agency Approvals
• Low on-state voltage
Agency
• Does not degrade surge
capability after multiple
surge events within
limit.
Agency File Number
E133083
• Robust surge current
ratings
• Gate triggered tracking
devices
• Pb-free E3 means 2nd
level interconnect is
Pb-free and the terminal
finish material is tin(Sn)
(IPC/JEDEC J-STD609A.01)
• Fails short circuit when
surged in excess of
ratings
Pinout Designation
PIN 3
(VREF)
Applicable Global Standards
PIN 1
(Line)
PIN 2
(Ground)
Schematic Symbol
PIN 2
(Ground)
PIN 3
(+VREF)
PIN 1
(Line)
PIN 3
(-VREF)
Gate
• TIA-968-A
• GR 1089 Intra-building
• TIA-968-B
• IEC 61000-4-5
• ITU K.20/21 Enhanced
Level*
• YD/T 1082
• ITU K.20/21 Basic Level
• YD/T 950
• YD/T 993
• GR 1089 Inter-building*
*A-rated parts require series resistance
PIN 1
(Line)
Positive Battrax
B2050C_
Negative Battrax
B1xx0C_
PIN 2
(Ground)
Electrical Characteristics
Part Number
B1100CALRP
B1160CALRP
B1200CALRP
B2050CALRP
B1100CCLRP
B1160CCLRP
B1200CCLRP
B2050CCLRP
VDRM
@lDRM=5µA
VS
@100V/µs
IH
IS
IT
VT
@IT=2.2 Amps
V min
V max
mA min
mA max
A max
V max
I-VREFI + I-1.2VI
I-VREFI + I-1.2VI
I-VREFI + I-1.2VI
I+VREFI + I1.2VI
I-VREFI + I-1.2VI
I-VREFI + I-1.2VI
I-VREFI + I-1.2VI
I+VREFI + I1.2VI
I-VREFI + I-10VI
I-VREFI + I-10VI
I-VREFI + I-10VI
I+VREFI + I10VI
I-VREFI + I-10VI
I-VREFI + I-10VI
I-VREFI + I-10VI
I+VREFI + I10VI
100
160
200
5
100
160
200
5
100
100
100
50
100
100
100
50
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
4
4
4
4
4
4
4
4
Marking
B10A
B16A
B12A
B25A
B10C
B16C
B12C
B25C
Notes:
- Absolute maximum ratings measured at TA= 25ºC (unless otherwise noted).
- Devices are uni-directional
- All electrical characteristics shown are defined from Tip (pin 1) to Ground (pin 2), and Ring
(pin 1) to Ground (pin 2)
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/12/16
Capacitance*
pF
Min
30
30
30
20
30
30
30
20
Max
200
200
200
200
200
200
200
200
- VREF Max Value for the negative Battrax is -200 V.
- VREF Max Value for the positive Battrax is 110 V.
* Off-state capacitance (CO) is measured across pins 1 & 2 at 1 MHz with a 2V bias.
SIDACtor ® Protection Thyristors
SLIC Protection
Surge Ratings
Series
IPP
0.2x310
0.5x700 2
1
1: Current waveform in µs
A min
2: Voltage waveform in µs
ITSM
50/60 Hz
di/dt
A min
A min
A/µs max
2x10
2x10 2
8x20
1.2x50 2
10x160
10x160 2
10x560 1
10x560 2
5x320 1
9x720 2
10x360 1
10x360 2
10x1000 1
10x1000 2
5x310 1
10x700 2
A min
A min
A min
A min
A min
A min
A min
1
1
1
A
20
150
150
90
50
75
75
45
75
20
500
C
50
500
400
200
150
200
175
100
200
50
500
Notes:
- Peak pulse current rating (IPP) is repetitive and guaranteed for the life of the product that remains in thermal equilibrium.
- IPP ratings applicable over temperature range of -40ºC to +85ºC (IPP rating assumes VREF equals +/- 48 V)
- The device must initially be in thermal equilibrium with -40°C < TJ < +150°C
1 Current waveform in µs
2 Voltage waveform in µs
Thermal Considerations
Package
Symbol
Parameter
Value
Unit
TJ
Operating Junction Temperature Range
-40 to +150
°C
TS
Storage Temperature Range
-65 to +150
°C
R0JA
Thermal Resistance: Junction to Ambient
85
°C/W
Modified DO-214AA
PIN 3
(VREF)
PIN 1
(Line)
PIN 2
(Ground)
V-I Characteristics - Negative Battrax
V-I Characteristics - Positive Battrax
+I
+I
IT
IGT
IH
VS VDRM
VT
IDRM
-V
-V
+V
+V
IDRM
VDRM VS
VT
IH
IGT
IT
-I
Normalized DC Holding Current vs. Case Temperature
10
IH
8
6
25 °C
4
2
IH (TC = 25ºC)
2.0
14
12
Ratio of
Percent of VS Change – %
Normalized VS Change vs. Junction Temperature
-I
0
-4
-6
1.8
1.6
1.4
1.0
0.8
0.6
0.4
-8
-40 -20
0
20 40 60 80 100 120 140 160
Junction Temperature (TJ) – °C
25°C
1.2
-40
-20
0
20
40
60
80
100 120 140 160
Case Temperature (TC) - ºC
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/12/16
SIDACtor ® Protection Thyristors
SLIC Protection
IPP – Peak Pulse Current – %IPP
tr x td Pulse Waveform
Peak
Value
100
Environmental Specifications
tr = rise time to peak value
td = decay time to half value
Waveform = tr x td
50
Half Value
0
0
td
tr
t – Time (µs)
Physical Specifications
Lead Material
Copper Alloy
Terminal Finish
100% Matte-Tin Plated
Body Material
UL recognized epoxy meeting flammability
classification 94V-0
High Temp Voltage
Blocking
80% Rated VREF Max. (VDC Peak ) +125°C or
+150°C, 504 or 1008 hrs. MIL-STD-750 (Method
1040) JEDEC, JESD22-A-101
Temp Cycling
-65°C to +150°C, 15 min. dwell, 10 up to 100
cycles. MIL-STD-750 (Method 1051) EIA/JEDEC,
JESD22-A104
Biased Temp &
Humidity
52 VDC (+85°C) 85%RH, 504 up to 1008 hrs. EIA/
JEDEC, JESD22-A-101
High Temp Storage
+150°C 1008 hrs. MIL-STD-750 (Method 1031)
JEDEC, JESD22-A-101
Low Temp Storage
-65°C, 1008 hrs.
Thermal Shock
0°C to +100°C, 5 min. dwell, 10 sec. transfer,
10 cycles. MIL-STD-750 (Method 1056) JEDEC,
JESD22-A-106
Autoclave (Pressure
Cooker Test)
+121°C, 100%RH, 2atm, 24 up to 168 hrs. EIA/
JEDEC, JESD22-A-102
Resistance to Solder
Heat
+260°C, 30 secs. MIL-STD-750 (Method 2031)
Moisture Sensitivity
Level
85%RH, +85°C, 168 hrs., 3 reflow cycles
(+260°C Peak). JEDEC-J-STD-020, Level 1
Soldering Parameters
- Temperature Min (Ts(min))
Pre Heat
- Temperature Max (Ts(max))
- Time (Min to Max) (ts)
Pb-Free assembly
(see Fig. 1)
+150°C
+200°C
60-180 secs.
Average ramp up rate (Liquidus Temp (TL)
to peak)
3°C/sec. Max.
TS(max) to TL - Ramp-up Rate
3°C/sec. Max.
Reflow
- Temperature (TL) (Liquidus)
+217°C
- Temperature (tL)
60-150 secs.
Peak Temp (TP)
+260(+0/-5)°C
Time within 5°C of actual Peak Temp (tp)
30 secs. Max.
Ramp-down Rate
6°C/sec. Max.
Time 25°C to Peak Temp (TP)
8 min. Max.
Battrax Series
Pos-Neg Mod DO-214 Part Numbering.eps
Do not exceed
+260°C
For Pg. 126
Part Numbering
Figure 1
TP
tP
Critical Zone
TL to TP
Ramp-up
Temperature
Reflow Condition
TL
TS(max)
tL
Ramp-down
Preheat
TS(min)
tS
25
time to peak temperature
(t 25ºC to peak)
Time
Compak PM Drawing for pg 126 Bat Pos-Neg.eps
Part Marking
Bx xx 0 C x L RP
TYPE
B1: Negative Battrax SIDACtor
B2: Positive Battrax SIDACtor
HOLDING CURRENT
05: 5 mA
16: 160 mA
10: 100 mA 20: 200 mA
CONSTRUCTION VARIABLE
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/12/16
REEL PACK
RoHS COMPLIANT
IPP RATING
PACKAGE TYPE
XXXX
XXXXX
Part Number Code
(Refer to Electrical Characteristics Table)
Date Code
SIDACtor ® Protection Thyristors
SLIC Protection
Dimensions — Modified DO-214AA
PIN 3
B
D
M
N
Dimensions
P
A C
A
B
C
D
E
F
G
H
K
M
N
P
PIN 1
PIN 2
H
E
J
0.079
(2.0)
0.079
(2.0)
F
K
G
0.079
(2.0)
0.040
(1.0)
0.110
(2.8)
0.030
(0.76)
Dimensions are in inches
(and millimeters).
Inches
Millimeters
Min
Max
Min
Max
0.130
0.201
0.077
0.159
0.030
0.075
0.002
0.077
0.006
0.022
0.027
0.052
0.156
0.220
0.087
0.181
0.063
0.096
0.008
0.104
0.016
0.028
0.033
0.058
3.30
5.10
1.95
4.05
0.75
1.90
0.05
1.95
0.15
0.56
0.69
1.32
3.95
5.60
2.20
4.60
1.60
2.45
0.20
2.65
0.41
0.71
0.84
1.47
Pad Outline
(MM)
Packing Options
Package Type
C
Description
Quantity
Added Suffix
Industry Standard
Modified DO-214AA 3-leaded
Tape and Reel Pack
2500
RP
EIA-481-D
Tape and Reel Specification — Modified DO-214AA
0.157
0.157 (4.0)
(4.0)
0.472
0.472
(12.0)
(12.0)
Pin 2
0.36
(9.2)
0.360
(9.2)
0.315
(8.0)
0.315
(8.0)
Pin 1
12.99
(330.0)
0.512 (13.0)
Arbor Hole Dia.
Pin 3
0.059Dimensions
aretape
in inches
DIA Cover
(1.5) (and millimeters).
Dimensions are in inches
(and millimeters).
Direction of Feed
0.49
(12.4)
Additional Information
Datasheet
Resources
Samples
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/12/16