SIDACtor ® Protection Thyristors SLIC Protection Battrax® Series Positive/Negative - Modified DO-214 Pb e3 RoHS Description The Battrax® series offers programmable SIDACtor® overvoltage protection devices for SLIC applications. This series is offered in a negative Battrax version and a positive Battrax version. The B1xx0C_ is for a -VREF supply and the B2050C_ is for a +VREF supply. Designed using an SCR and a gate diode, the B1xx0C_ Battrax begins to conduct at |-VREF| + |-1.2 V| while the B2050C_ Battrax begins to conduct at |+VREF| + |1.2 V|. Features and Benefits • Low voltage overshoot Agency Approvals • Low on-state voltage Agency • Does not degrade surge capability after multiple surge events within limit. Agency File Number E133083 • Robust surge current ratings • Gate triggered tracking devices • Pb-free E3 means 2nd level interconnect is Pb-free and the terminal finish material is tin(Sn) (IPC/JEDEC J-STD609A.01) • Fails short circuit when surged in excess of ratings Pinout Designation PIN 3 (VREF) Applicable Global Standards PIN 1 (Line) PIN 2 (Ground) Schematic Symbol PIN 2 (Ground) PIN 3 (+VREF) PIN 1 (Line) PIN 3 (-VREF) Gate • TIA-968-A • GR 1089 Intra-building • TIA-968-B • IEC 61000-4-5 • ITU K.20/21 Enhanced Level* • YD/T 1082 • ITU K.20/21 Basic Level • YD/T 950 • YD/T 993 • GR 1089 Inter-building* *A-rated parts require series resistance PIN 1 (Line) Positive Battrax B2050C_ Negative Battrax B1xx0C_ PIN 2 (Ground) Electrical Characteristics Part Number B1100CALRP B1160CALRP B1200CALRP B2050CALRP B1100CCLRP B1160CCLRP B1200CCLRP B2050CCLRP VDRM @lDRM=5µA VS @100V/µs IH IS IT VT @IT=2.2 Amps V min V max mA min mA max A max V max I-VREFI + I-1.2VI I-VREFI + I-1.2VI I-VREFI + I-1.2VI I+VREFI + I1.2VI I-VREFI + I-1.2VI I-VREFI + I-1.2VI I-VREFI + I-1.2VI I+VREFI + I1.2VI I-VREFI + I-10VI I-VREFI + I-10VI I-VREFI + I-10VI I+VREFI + I10VI I-VREFI + I-10VI I-VREFI + I-10VI I-VREFI + I-10VI I+VREFI + I10VI 100 160 200 5 100 160 200 5 100 100 100 50 100 100 100 50 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 4 4 4 4 4 4 4 4 Marking B10A B16A B12A B25A B10C B16C B12C B25C Notes: - Absolute maximum ratings measured at TA= 25ºC (unless otherwise noted). - Devices are uni-directional - All electrical characteristics shown are defined from Tip (pin 1) to Ground (pin 2), and Ring (pin 1) to Ground (pin 2) © 2016 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 05/12/16 Capacitance* pF Min 30 30 30 20 30 30 30 20 Max 200 200 200 200 200 200 200 200 - VREF Max Value for the negative Battrax is -200 V. - VREF Max Value for the positive Battrax is 110 V. * Off-state capacitance (CO) is measured across pins 1 & 2 at 1 MHz with a 2V bias. SIDACtor ® Protection Thyristors SLIC Protection Surge Ratings Series IPP 0.2x310 0.5x700 2 1 1: Current waveform in µs A min 2: Voltage waveform in µs ITSM 50/60 Hz di/dt A min A min A/µs max 2x10 2x10 2 8x20 1.2x50 2 10x160 10x160 2 10x560 1 10x560 2 5x320 1 9x720 2 10x360 1 10x360 2 10x1000 1 10x1000 2 5x310 1 10x700 2 A min A min A min A min A min A min A min 1 1 1 A 20 150 150 90 50 75 75 45 75 20 500 C 50 500 400 200 150 200 175 100 200 50 500 Notes: - Peak pulse current rating (IPP) is repetitive and guaranteed for the life of the product that remains in thermal equilibrium. - IPP ratings applicable over temperature range of -40ºC to +85ºC (IPP rating assumes VREF equals +/- 48 V) - The device must initially be in thermal equilibrium with -40°C < TJ < +150°C 1 Current waveform in µs 2 Voltage waveform in µs Thermal Considerations Package Symbol Parameter Value Unit TJ Operating Junction Temperature Range -40 to +150 °C TS Storage Temperature Range -65 to +150 °C R0JA Thermal Resistance: Junction to Ambient 85 °C/W Modified DO-214AA PIN 3 (VREF) PIN 1 (Line) PIN 2 (Ground) V-I Characteristics - Negative Battrax V-I Characteristics - Positive Battrax +I +I IT IGT IH VS VDRM VT IDRM -V -V +V +V IDRM VDRM VS VT IH IGT IT -I Normalized DC Holding Current vs. Case Temperature 10 IH 8 6 25 °C 4 2 IH (TC = 25ºC) 2.0 14 12 Ratio of Percent of VS Change – % Normalized VS Change vs. Junction Temperature -I 0 -4 -6 1.8 1.6 1.4 1.0 0.8 0.6 0.4 -8 -40 -20 0 20 40 60 80 100 120 140 160 Junction Temperature (TJ) – °C 25°C 1.2 -40 -20 0 20 40 60 80 100 120 140 160 Case Temperature (TC) - ºC © 2016 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 05/12/16 SIDACtor ® Protection Thyristors SLIC Protection IPP – Peak Pulse Current – %IPP tr x td Pulse Waveform Peak Value 100 Environmental Specifications tr = rise time to peak value td = decay time to half value Waveform = tr x td 50 Half Value 0 0 td tr t – Time (µs) Physical Specifications Lead Material Copper Alloy Terminal Finish 100% Matte-Tin Plated Body Material UL recognized epoxy meeting flammability classification 94V-0 High Temp Voltage Blocking 80% Rated VREF Max. (VDC Peak ) +125°C or +150°C, 504 or 1008 hrs. MIL-STD-750 (Method 1040) JEDEC, JESD22-A-101 Temp Cycling -65°C to +150°C, 15 min. dwell, 10 up to 100 cycles. MIL-STD-750 (Method 1051) EIA/JEDEC, JESD22-A104 Biased Temp & Humidity 52 VDC (+85°C) 85%RH, 504 up to 1008 hrs. EIA/ JEDEC, JESD22-A-101 High Temp Storage +150°C 1008 hrs. MIL-STD-750 (Method 1031) JEDEC, JESD22-A-101 Low Temp Storage -65°C, 1008 hrs. Thermal Shock 0°C to +100°C, 5 min. dwell, 10 sec. transfer, 10 cycles. MIL-STD-750 (Method 1056) JEDEC, JESD22-A-106 Autoclave (Pressure Cooker Test) +121°C, 100%RH, 2atm, 24 up to 168 hrs. EIA/ JEDEC, JESD22-A-102 Resistance to Solder Heat +260°C, 30 secs. MIL-STD-750 (Method 2031) Moisture Sensitivity Level 85%RH, +85°C, 168 hrs., 3 reflow cycles (+260°C Peak). JEDEC-J-STD-020, Level 1 Soldering Parameters - Temperature Min (Ts(min)) Pre Heat - Temperature Max (Ts(max)) - Time (Min to Max) (ts) Pb-Free assembly (see Fig. 1) +150°C +200°C 60-180 secs. Average ramp up rate (Liquidus Temp (TL) to peak) 3°C/sec. Max. TS(max) to TL - Ramp-up Rate 3°C/sec. Max. Reflow - Temperature (TL) (Liquidus) +217°C - Temperature (tL) 60-150 secs. Peak Temp (TP) +260(+0/-5)°C Time within 5°C of actual Peak Temp (tp) 30 secs. Max. Ramp-down Rate 6°C/sec. Max. Time 25°C to Peak Temp (TP) 8 min. Max. Battrax Series Pos-Neg Mod DO-214 Part Numbering.eps Do not exceed +260°C For Pg. 126 Part Numbering Figure 1 TP tP Critical Zone TL to TP Ramp-up Temperature Reflow Condition TL TS(max) tL Ramp-down Preheat TS(min) tS 25 time to peak temperature (t 25ºC to peak) Time Compak PM Drawing for pg 126 Bat Pos-Neg.eps Part Marking Bx xx 0 C x L RP TYPE B1: Negative Battrax SIDACtor B2: Positive Battrax SIDACtor HOLDING CURRENT 05: 5 mA 16: 160 mA 10: 100 mA 20: 200 mA CONSTRUCTION VARIABLE © 2016 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 05/12/16 REEL PACK RoHS COMPLIANT IPP RATING PACKAGE TYPE XXXX XXXXX Part Number Code (Refer to Electrical Characteristics Table) Date Code SIDACtor ® Protection Thyristors SLIC Protection Dimensions — Modified DO-214AA PIN 3 B D M N Dimensions P A C A B C D E F G H K M N P PIN 1 PIN 2 H E J 0.079 (2.0) 0.079 (2.0) F K G 0.079 (2.0) 0.040 (1.0) 0.110 (2.8) 0.030 (0.76) Dimensions are in inches (and millimeters). Inches Millimeters Min Max Min Max 0.130 0.201 0.077 0.159 0.030 0.075 0.002 0.077 0.006 0.022 0.027 0.052 0.156 0.220 0.087 0.181 0.063 0.096 0.008 0.104 0.016 0.028 0.033 0.058 3.30 5.10 1.95 4.05 0.75 1.90 0.05 1.95 0.15 0.56 0.69 1.32 3.95 5.60 2.20 4.60 1.60 2.45 0.20 2.65 0.41 0.71 0.84 1.47 Pad Outline (MM) Packing Options Package Type C Description Quantity Added Suffix Industry Standard Modified DO-214AA 3-leaded Tape and Reel Pack 2500 RP EIA-481-D Tape and Reel Specification — Modified DO-214AA 0.157 0.157 (4.0) (4.0) 0.472 0.472 (12.0) (12.0) Pin 2 0.36 (9.2) 0.360 (9.2) 0.315 (8.0) 0.315 (8.0) Pin 1 12.99 (330.0) 0.512 (13.0) Arbor Hole Dia. Pin 3 0.059Dimensions aretape in inches DIA Cover (1.5) (and millimeters). Dimensions are in inches (and millimeters). Direction of Feed 0.49 (12.4) Additional Information Datasheet Resources Samples © 2016 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 05/12/16