Introduction MOS FET Relays General-purpose G3VM-@AR/@DR DIP 4-pin, High-current and Low-ON-resistance Type High-load-voltage MOS FET Relays in DIP 4-pin packages that achieve the low ON resistance and high switching capacity of a mechanical relay • 20-V Relay: Continuous load current of 3 A max. • 40-V Relay: Continuous load current of 2.5 A max. • 60-V Relay: Continuous load current of 2 A max. Note: The actual product is marked differently from the image shown here. • 100-V Relay: Continuous load current of 1 A max. RoHS Compliant ■Application Examples • Communication equipment • Security equipment • Test & Measurement equipment • Industrial equipment High-dielectricstrength ■Package • Power circuit ■Model Number Legend (Unit : mm, Average) PCB Terminals 1 2 3 4 4.58 6.4 Surface-mounting Terminals 5 2. Contact form 1 : 1a (SPST-NO) 3.65 5. Other informations When specifications overlap, serial code is added in the recorded order. Small and Highload-voltage 4. Additional functions R: Low ON resistance 4.58 3. Package A : DIP 4-pin with PCB terminals D : DIP 4-pin with surface-mounting terminals Low-output-capacitance and Low-ON-resistance 1. Load Voltage 2 : 20 V 4 : 40 V 6 : 60 V 10 : 100 V 3.65 Current-limiting G3V M- @ @ @ @ @ DIP 4-pin 6.4 Certified Models with Standards Certification Note: The actual product is marked differently from the image shown here. ■Ordering Information Stick packaging Package 1a (SPST-NO) Load voltage Continuous load current (peak value) * (peak value) * Model PCB Terminals Surface-mounting Terminals 20 V 3A G3VM-21AR G3VM-21DR 40 V 2.5 A G3VM-41AR G3VM-41DR 60 V 2A G3VM-61AR G3VM-61DR 100 V 1A G3VM-101AR G3VM-101DR Tape packaging Minimum package quantity Model Surface-mounting Terminals Minimum package quantity G3VM-21DR(TR) 100 pcs. G3VM-41DR(TR) G3VM-61DR(TR) 1,500 pcs. G3VM-101DR(TR) * The AC peak and DC value are given for the load voltage and continuous load current. Note: To order tape packaging for Relays with surface-mounting terminals, add “(TR)” to the end of the model number. 103 DIP SOP SSOP USOP VSON G3VM-@AR/@DR DIP4 Contact form Small and HighMulti-contact-pair High-current and (2a, 2b, and 1a1b) Low-ON-resistance dielectric-strength • Load voltage: 20 V, 40 V, 60 V, or 100 V MOS FET Relays Item LED forward current High-load-voltage Input General-purpose ■Absolute Maximum Ratings (Ta = 25°C) Repetitive peak LED forward current Symbol G3VM-21AR G3VM-21DR G3VM-41AR G3VM-41DR IF G3VM-61AR G3VM-61DR G3VM-101AR G3VM-101DR 30 Unit IFP 1 A ΔIF/°C -0.3 mA/°C LED reverse voltage VR 5 V Small and HighMulti-contact-pair High-current and (2a, 2b, and 1a1b) Low-ON-resistance dielectric-strength Load voltage (AC peak/DC) TJ 125 20 40 60 100 IO 3 2.5 2 1 A ΔIO/°C -30 -25 -20 -10 mA/°C Pulse ON current lop 9 7.5 6 3 Connection temperature TJ Dielectric strength between I/O (See note 1.) Ambient operating temperature ON current reduction rate Ambient storage temperature Soldering temperature 100 μs pulses, 100 pps Ta ≥ 25°C °C VOFF Continuous load current (AC peak/DC) Measurement conditions mA LED forward current reduction rate Connection temperature Output Introduction G3VM-@AR/@DR V A 125 °C VI-O 2,500 Vrms Ta -40 to +85 °C Tstg -55 to +125 °C − 260 °C Ta ≥ 25°C t=100 ms, Duty=1/10 AC for 1 min With no icing or condensation 10 s Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. High-dielectricstrength Current-limiting Low-output-capacitance and Low-ON-resistance Small and Highload-voltage Certified Models with Standards Certification DIP SOP SSOP USOP VSON G3VM-@AR/@DR 104 MOS FET Relays G3VM-21AR G3VM-21DR Symbol LED forward voltage VF Reverse current Capacitance between terminals IR Minimum Typical Maximum Maximum CT Typical IFT (IFC) Release LED forward current IFC (IFT) Maximum resistance with output ON RON Typical Minimum 0.1 Output Maximum COFF Typical CI-O Typical IF 40 50 80 3 RL pF V=0, f=1 MHz mA IO=1 A mA IOFF=10 μA mΩ G3VM-21AR/21DR/41AR/41DR/61AR/61DR : IF=5 mA, t < 1s, IO=2 A G3VM-101AR/DR : IF=5 mA, t < 1s, IO=1 A μA VOFF=Load voltage ratings 250 200 700 1 300 250 200 0.8 1000 108 1 pF V=0, f=1 MHz pF f=1 MHz, VS=0 V MΩ VI-O=500 VDC, ROH≤60% ms IF=5 mA, RL=200 Ω, VDD=20 V (See note 2.) 0.8 5 0.3 1 VDD VOUT Low-output-capacitance and Low-ON-resistance 4 2 80 150 RI-O 1 IF=10 mA VR=5 V IF 10% 90% t ON Small and Highload-voltage VOUT t OFF ■Recommended Operating Conditions Item Symbol Load voltage (AC peak/DC) VDD Maximum G3VM-21AR G3VM-21DR G3VM-41AR G3VM-41DR G3VM-61AR G3VM-61DR G3VM-101AR G3VM-101DR Unit 16 32 48 80 V Minimum Operating LED forward current IF IO Ambient operating temperature Ta Typical 10 Maximum 25 Maximum 3 2.5 mA 2 Minimum -20 Maximum 65 1 A °C ■Spacing and Insulation Minimum Creepage distances 7.0 Clearance distances 7.0 Internal isolation thickness 0.4 Unit mm 105 DIP SOP SSOP USOP VSON G3VM-@AR/@DR Continuous load current (AC peak/DC) 5 Certified Models with Standards Certification For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute Maximum Ratings and Electrical Characteristics. Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions. Item Current-limiting Minimum Typical Typical Turn-ON time tON Maximum Typical Turn-OFF time tOFF Maximum Note: 2. Turn-ON and Turn-OFF Times V μA High-dielectricstrength ILEAK Measurement conditions 0.5 3 Maximum Insulation resistance between I/O terminals 0.7 Maximum Typical Current leakage when the relay is open Capacitance between terminals Capacitance between I/ O terminals 70 G3VM-101AR Unit G3VM-101DR Small and HighMulti-contact-pair High-current and (2a, 2b, and 1a1b) Low-ON-resistance dielectric-strength Trigger LED forward current G3VM-41AR G3VM-61AR G3VM-41DR G3VM-61DR 1.18 1.33 1.48 10 High-load-voltage Input Item General-purpose ■Electrical Characteristics (Ta = 25°C) Introduction G3VM-@AR/@DR MOS FET Relays ● LED forward current vs. Ambient temperature ● Continuous load current vs. Ambient temperature ● LED forward current vs. LED forward voltage IO - Ta 25 15 G3VM-21AR/DR 3 G3VM-41AR/DR G3VM-61AR/DR 2 G3VM-101AR/DR 10 1 1 0.1 -40 -20 0 20 40 60 80 0 -40 100 -20 0 20 ● Continuous load current vs. On-state voltage 80 G3VM-61AR/DR 1 High-dielectricstrength G3VM-101AR/DR 0 -1 400 G3VM-61AR/DR G3VM-41AR/DR 0 0.1 0.2 0 0.3 1.2 1.3 1.4 1.5 1.6 1.7 1.5 G3VM-21AR/DR IO=1A t<1s 1 G3VM-41AR/DR 0.5 G3VM-101AR/DR G3VM-61AR/DR 0 -40 -20 0 20 80 100 -40 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) G3VM-41AR/DR 1 tOFF tOFF tON G3VM-21AR/DR Certified Models with Standards Certification tON 10 10 VDD=20V, RL=200Ω, Ta=25°C G3VM-61AR/DR 1 tOFF 0.1 0.01 100 tON G3VM-101AR/DR 1 10 LED forward current IF (mA) 100 LED forward current IF (mA) ● Turn ON, Turn OFF time vs. Ambient temperature G3VM-21AR/21DR/41AR/41DR G3VM-61AR/61DR/101AR/101DR ● Current leakage vs. Ambient temperature tON, tOFF - Ta tON, tOFF - Ta 10 G3VM-@AR/@DR VDD=20V, RL=200Ω, IF=5mA G3VM-21AR/DR tON tON 1 G3VM-41AR/DR tOFF Turn ON, Turn OFF time tON, tOFF (ms) Small and Highload-voltage Turn ON, Turn OFF time tON, tOFF (ms) tON, tOFF - IF VDD=20V, RL=200Ω, Ta=25°C 1 60 G3VM-61AR/61DR/101AR/101DR 10 0.1 40 Ambient temperature Ta (°C) tON, tOFF - IF Turn ON, Turn OFF time tON, tOFF (ms) 1.1 G3VM-21AR/DR -0.1 ● Turn ON, Turn OFF time vs. LED forward current G3VM-21AR/21DR/41AR/41DR 0.01 1 IFT - Ta 200 On-state voltage VON (V) Turn ON, Turn OFF time tON, tOFF (ms) Current-limiting Low-output-capacitance and Low-ON-resistance -0.2 0.9 ● Trigger LED forward current vs. Ambient temperature G3VM-101AR/DR 300 G3VM41AR/DR -0.3 0.8 LED forward voltage VF (V) G3VM-101AR/DR: IO=1A, IF=5mA, t<1s The others: IO=2A, IF=5mA, t<1s 100 -3 0.01 100 RON - Ta G3VM-21AR/DR Ta=25°C IF=5mA 2 60 ● On-state resistance vs. Ambient temperature IO - VON 3 40 Ambient temperature Ta (°C) Ambient temperature Ta (°C) Trigger LED forward current IFT (mA) 0 -2 DIP SOP SSOP USOP VSON Ta=25°C 10 5 ILEAK - Ta 10 VDD=20V, RL=200Ω, IF=5mA G3VM-61AR/DR 1 tON Current leakage ILEAK (nA) Small and HighMulti-contact-pair High-current and (2a, 2b, and 1a1b) Low-ON-resistance dielectric-strength 20 100 LED forward current IF (mA) 30 IF - VF 4 Continuous load current IO (A) 35 On-state resistance RON (mΩ) High-load-voltage IF - Ta LED forward current IF (mA) General-purpose ■Engineering Data Continuous load current IO (A) Introduction G3VM-@AR/@DR 100 VOFF=Load voltage ratings 10 G3VM-41AR/DR G3VM-101AR/DR 1 G3VM-21AR/DR G3VM-101AR/DR 0.1 tOFF G3VM-61AR/DR G3VM-21AR/DR 0.1 0.1 -40 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) 106 -40 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) 0.01 -20 0 20 40 60 80 Ambient temperature Ta (°C) MOS FET Relays ●Appearance General-purpose ■Appearance / Terminal Arrangement / Internal Connections ●Terminal Arrangement/Internal Connections (Top View) DIP (Dual Inline Package) High-load-voltage DIP 4-pin Mold pin mark (See note 3.) OMRON logo Model name (See note 2.) Pin 1 mark 932 LOT.NO. Small and HighMulti-contact-pair High-current and (2a, 2b, and 1a1b) Low-ON-resistance dielectric-strength Note: 1. The actual product is marked differently from the image shown here. Note: 2. “G3VM” does not appear in the model number on the Relay. Note: 3. The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. ■Dimensions (Unit: mm) PCB Terminals Surface-mounting Terminals Weight: 0.25 g Weight: 0.25 g PCB Dimensions (BOTTOM VIEW) 2.54 Four, 0.8-dia. holes (0.61) 2.54 4.58±0.25 4.58±0.25 Actual Mounting Pad Dimensions 6.4±0.25 7.62±0.25 0.8±0.25 (Recommended Value, Top View) 7.62±0.25 High-dielectricstrength (0.61) (1.52) (1.52) 6.4±0.25 2.54 3.65+0.15 -0.25 1.2±0.15 0.5±0.1 2.54±0.25 7.85 to 8.80 3.65+0.15 -0.25 4.0+0.25 -0.2 1.0 min. 8.3 to 8.8 1.2±0.15 2.54±0.25 Current-limiting 0.25+0.1 -0.05 2.5 min. Introduction G3VM-@AR/@DR 1.0 min. 10.0 max. 1.3 1.5 Low-output-capacitance and Low-ON-resistance Note: The actual product is marked differently from the image shown here. ■Approved Standards UL recognized Contact form File No. UL (recognized) 1a (SPST-NO) E80555 Small and Highload-voltage Approved Standards Certified Models with Standards Certification ■Safety Precautions • Refer to the Common Precautions for All MOS FET Relays for precautions that apply to all MOS FET Relays. DIP SOP SSOP USOP VSON G3VM-@AR/@DR 107