G5Q PCB Power Relay A Miniature Power Relay with 1-pole 10A Switching Capacity • Compact single pole relay. • Excellent switching performance for a variety of loads. • Small, yet provide 8-kV impulse withstand voltage (between coil and contacts). • Low coil power consumption (SPST-NO: 200 mW, SPDT: 400 mW) • Coil insulation system: Class F (UL1446). • IEC/EN 60335-1 conformed. (-HA Model) RoHS Compliant ■Model Number Legend ■Application Examples G 5 Q -@ @ @-@ - @ ——— — — 1 2 3 4 5 1. Number of Poles 1 : 1-pole 2. Contact Form None : SPDT (1c) A : SPST-NO (1a) 3. Enclosure rating None : Flux protection 4 : Sealed • Ideal for output applications of control equipments. 4. Classification None : Standard EU : High-capacity G 5 Q 5. Market Code None : General purpose HA : Home Appliance according to IEC/EN60335-1 ■Ordering Information Terminal Shape Market Code Classification Contact form SPST-NO (1a) Standard SPDT (1c) General purpose PCB terminals SPST-NO (1a) High-capacity SPDT (1c) SPST-NO (1a) SPDT (1c) Home Appliance Enclosure rating Flux protection Sealed Flux protection Sealed Flux protection Sealed Flux protection Sealed Flux protection Model G5Q-1A G5Q-1A4 G5Q-1 G5Q-14 G5Q-1A-EU G5Q-1A4-EU G5Q-1-EU G5Q-14-EU G5Q-1A-EU-HA G5Q-1-EU-HA Rated coil voltage 5VDC 9VDC 12VDC 24VDC Minimum packing unit 5VDC 12VDC 24VDC 40 pcs/tube 12VDC 24VDC Note. When ordering, add the rated coil voltage to the model number. Example: G5Q-1A DC5 Rated coil voltage ■Ratings ●Coil Contact form Rated voltage Rated current (mA) Coil resistance (Ω) Must operate voltage (V) Must release voltage (V) % of rated voltage 5 VDC 125 40 9 VDC 405 22.2 12 VDC 720 16.7 24 VDC 2880 8.3 75% max. 5% min. 5 VDC 63 80 9 VDC 202 44.4 SPDT (1c) 12 VDC 360 33.3 24 VDC 1440 16.7 Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil. Max. voltage (V) SPST-NO (1a) Power consumption (mW) Approx. 200 190% (at 23°C) Approx. 400 1 G5Q PCB Power Relay ●Contacts Load Resistive load SPST-NO (1a) Standard High-capacity Standard Item Contact Type Contact material Single Ag-Alloy (Cd free) Rated load (resistive) 10 A at 125 VAC 3 A at 125 VAC 3 A at 250 VAC 5 A at 30 VDC Rated carry current Max. switching voltage Max. switching current SPDT (1c) 10 A at 125 VAC (NO) 3 A at 125 VAC (NO) 3 A at 250 VAC (NO) 5 A at 30 VDC (NO) 3 A at 125 VAC (NC) 3 A at 250 VAC (NC) 3 A at 30 VDC (NC) 10 A at 250 VAC 3 A at 125 VAC 3 A at 250 VAC 5 A at 30 VDC High-capacity 10 A at 250 VAC (NO) 3 A at 125 VAC (NO) 3 A at 250 VAC (NO) 5 A at 30 VDC (NO) 3 A at 125 VAC (NC) 3 A at 250 VAC (NC) 3 A at 30 VDC (NC) 10 A (NO)/3 A (NC) 277 VAC, 30 VDC AC: 10 A (NO)/3 A (NC) DC: 5 A (NO)/3 A (NC) ■Characteristics Item Classification 100 mΩ max. Operate time 10 ms max. Release time 5 ms max. Insulation resistance *2 G 5 Q Standard model Contact resistance *1 Dielectric strength 1,000 MΩ min. Between coil and contacts 4,000 VAC, 50/60 Hz for 1 min Between contacts of the same polarity 1,000 VAC, 50/60 Hz for 1 min Impulse withstand voltage (between coil and contacts) 8 kV (1.2 x 50 μs) Vibration resistance Destruction Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Shock resistance Destruction 1,000 m/s2 Malfunction 100 m/s2 Durability 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Mechanical 10,000,000 operations (18,000 operations per hour) Electrical • NO 25,000 operations: 10 A at 250 VAC resistive load (operation: ON for 1 sec, OFF for 3 sec) <High-capacity type> 50,000 operations: 10 A at 125 VAC resistive load (operation: ON for 1 sec, OFF for 3 sec) 200,000 operations: 3 A at 125 VAC resistive load (operation: ON for 1 sec, OFF for 1 sec) 100,000 operations: 3 A at 250 VAC resistive load (operation: ON for 1 sec, OFF for 1 sec) 100,000 operations: 5 A at 30 VDC resistive load (operation: ON for 1 sec, OFF for 1 sec) • NC 200,000 operations: 3 A at 125 VAC resistive load (operation: ON for 1 sec, OFF for 1 sec) 100,000 operations: 3 A at 250 VAC resistive load (operation: ON for 1 sec, OFF for 1 sec) 100,000 operations: 3 A at 30 VDC resistive load (operation: ON for 1 sec, OFF for 1 sec) Failure rate (P level) (reference *3) 10 mA at 5 VDC Ambient operating temperature -40°C to 105°C (with no icing or condensation) -40°C to 85°C (with no icing or condensation) <High-capacity type> Ambient operating humidity 5% to 85% Weight Approx. 6.5 g Note. Note. Values in the above table are the initial values at 23°C. *1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method. *2. Testing conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. *3. This value was measured at a switching frequency of 120 operations/min. 2 G5Q PCB Power Relay ■Engineering Data ●Ambient Temperature VS. Maximum Coil Voltage Maximum coil voltage (% of rated) Switching current (A) ●Maximum Switching Capacity 100 AC resistive load (NO) 10 DC resistive load (NO) ●Shock Malfunction Y 200 1,000 180 160 X 1,000 140 Z 1,000 120 NC NO Contact 300 Contact 100 80 300 1,000 Z' 60 AC resistive load (NC) 1,000 X' 40 DC resistive load (NC) 1 1 1,000 Y' 20 10 100 0 -40 1000 -20 0 20 23 40 100 120 105 Ambient temperature (°C) Switching voltgate (V) 60 80 Note. The Maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Unit: m/s2 Shock direction Sample: G5Q-14 12 VDC X X' Number of Relays: 5 pcs Y Test conditions: Shock is applied Z in ±X, ±Y, and ±Z directions three Z' times each with without energizing the Relays to check Y' the number of malfunctions. Requirement: None malfuction 100 m/s2 ■Dimensions (Unit: mm) G5Q-1A G5Q-1A4 G5Q-1A-EU (-HA) G5Q-1A4-EU PCB Mounting Holes (Bottom View) Tolerance: ±0.1 mm 10.3MAX (10.0)* 20.3MAX (20.0)* . .1 (1.18) 3 -1. ±0 dia 4 (1.19) 1 0.27 MAX (No coil polarity) 10.16±0.1 1 0.4 x 0.4 7.62 10.16 G5Q-1 G5Q-14 G5Q-1-EU (-HA) G5Q-14-EU * Average value 7.62 PCB Mounting Holes (Bottom View) Tolerance: ±0.1 mm 10.3MAX (10.0)* 20.3MAX (20.0)* (1.18) . .3 5-1 .1 ±0 (1.19) 15.8MAX (15.5)* 0.4 3.4 0.4 x 0.4 3 5 7.62±0.1 3.4 2 7.62±0.1 15.8MAX (15.5)* 0.4 Terminal Arrangement/ Internal Connections (Bottom View) dia Terminal Arrangement/ Internal Connections (Bottom View) 1 2 3 7.62±0.1 5 0.27 MAX 2.54±0.1 1 5.08 2.54 (No coil polarity) 5.08±0.1 7.62 10.16 4 10.16±0.1 * Average value 3 G 5 Q G5Q PCB Power Relay ■Approved Standards UL Recognized: (File No. E41515) CSA Certified: Model (File No. LR31928) Contact form Coil ratings Number of test operations Contact ratings 10 A 250 VAC N.O. only (Resistive) 40°C G5Q-1 G5Q-1-EU G5Q-1A G5Q-1A-EU 10 A 30 VDC N.O. only (Resistive) 40°C SPST-NO (1a) SPDT (1c) 5 to 48 VDC 4 A 120 VAC N.O. only (Resistive) 40°C 3 A 250 VAC N.C. only (Resistive) 40°C 3 A 30 VDC N.C. only (Resistive) 40°C EN/IEC, VDE Model 100,000 6,000 (Certified/No.40009467) Contact form SPST-NO (1a) SPDT (1c) Contact ratings Number of test operations 10 A making and 0 A breaking, 250 VAC (cosφ=1) 105°C 5 A marking and 3 A breaking, 30 VDC (0 ms) 105°C 10,000 5 A 250 VAC (cosφ=1) (N.O.) 105°C 75,000 10 A 250 VAC (cosφ=1) (N.O.) 65°C 5 A 30 VDC (0 ms) (N.O.) 65°C 3 A 30 VDC (0 ms) (N.C.) 65°C 10,000 4 A 250 VAC (cosφ=1) (N.O.) 85°C 100,000 Coil ratings G5Q-1 G5Q-1A 5 to 48 VDC G5Q-1-EU (-HA) G5Q-1A-EU (-HA) G 5 Q 6,000 Creepage distance 6.4 mm min. Clearance distance 5.5 mm min. Insulation material group IIIa Type of insulation coil-contact circuit open contact circuit Basic (Rated voltage 400 V) / Reinforced (Rated voltage 250 V) Micro disconnection Rated Insulation voltage 250 V Pollution degree 2 Rated voltage system 250 V / 400 V (EU flux type only) Over voltage category III Category of protection according to IEC 61810-1 RT II (Flux protection) / RT III (Sealed) Glow wire according to IEC 60335-1 <HA Models only> GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12) Tracking Index of relay base PTI 250 V min. (housing parts) Flammability class according to UL94 V-0 Coil Insulation system F Class (UL 1446) ■Precautions ●Please refer to “PCB Relays Common Precautions” for correct use. • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company 4 Contact: www.omron.com/ecb Cat. No. J155-E1-08 0316(0207)(O)