Switch Ready Network Zone System specifications The switch ready network zone system shall include copper/fiber uplinks and downlinks optimized for industrial Ethernet switches. System shall incorporate redundant power supplies with maintenance - free UPS. The enclosure shall be UL Type 4/12/4X and IP66 rated. A removable, pre-engineered back plate with DIN rails shall be incorporated in the enclosure. Pre-installed accessory side panels, fiber slack spool, and L rings shall be included for cable management. The door shall be secured with 3mm double bit or slotted latch drive feature. The door shall hinge on the right or left. Class 2 power circuits shall be pre-wired, labeled, and tested. A barrier shall be present to isolate IT personnel from high voltage power circuit. technical information Standards: UL 508A Standard for Industrial Control Panels, UL Type 4/12 or 4X, IP66 Rated Dimensions: Z23R: 36.0"H x 24.0"W x 11.7"D (914mm x 610mm x 297mm) Z22R: 24.0"H x 24.0"W x 11.7"D (610mm x 610mm x 297mm) Color and material: Enclosures: Gray, 14 gauge cold roll steel or 316 stainless steel Back panels: 14 gauge galvannealed steel or 304 stainless steel Thermal analysis: Validated to 40°C ambient outside of enclosure or 60°C maximum within enclosure at up to 95% (non-condensing) humidity Installation: Wall mount with optional outside-mount flange key features and benefits Switch ready solution: Reduces time required for planning, designing, procurement, and installation, resulting in simpler specification and faster implementation Designed to accept customer supplied industrial switches: Offer management and diagnostics from within IT and controls environments to optimize network traffic Copper/fiber uplinks Enables troubleshooting of network connections and verification of or patch field and field terminations copper/fiber connectivity: Installed no battery, maintenance-free UPS: Prevents rebooting of switch during short power outages and includes networked remote management which monitors Hold Time and Lifetime from the plant floor or office, saving time and money Included redundant power supplies: Minimize the risk of equipment failure for improved network reliability Isolation barrier: Segregates higher line voltage from lower voltage switch for increased safety Bonding provisions and grounding bar: Ensure path to ground to protect personnel and equipment Gland plate: Allows quick and easy access to machine ingress points into enclosure Detailed installation guide: Provides easy, repeatable design instructions assuring consistency and saving time on the job-site applications The Panduit Switch Ready Network Zone System is designed to rapidly deploy an EtherNet/IP*** network between the enterprise and plant floor. Copper/fiber connectivity and power features minimize engineering and installation time resulting in faster implementation. The Switch Ready Network Zone System provides usability similar to IT switches for industrial switches on the plant floor. This ensures that management and control of the network does not get in the way of making the most effective use of available network data. With UL Type 4/12/4X and IP66 ratings, the enclosures provide reliability and high performance, as an integral component of the end-to-end solution for Industrial Networks. *Rockwell Automation and Allen-Bradley are registered by Rockwell Automation in the Patent and Trademark Office of the United States. **Stratix, Stratix 8000, Stratix 5700 and Integrated Architecture are trademarks of Rockwell Automation. ***EtherNet/IP is a trademark of ODVA. w w w . pa n d u it.c o m /n e two rkzone SPECIFICATION SHEET Switch Ready Network Zone System See part number table on pages 2-3 Related Products PanZone® NEMA 4X Rated Compression Fittings Cable diameters 0.115" – 0.250": Cable diameters 0.230" – 0.395": Cable diameters 0.170" – 0.450": Drain kit: PZNF1 PZNF2 PZNF3 PZNDVK IndustrialNet ™ TX6™ Connectors Category 6 UTP bulkhead connector: Category 6 STP bulkhead connector: IAEBH6 IAEBH6S Fiber Uplink Accessories Surface mount fiber box: CBXF6BL-AY LC OptiCam® connector: FLCDMCXAQY LC connector module: CMDSAQLCBL LC patch 10Gig patch cord: FXE10-10M1Y Opti-Core® Interlocking Armored Cable: FOPRX12Y DIN Rail Patching Accessories Mini-Com ® Copper 8-Port DIN Rail Patch Panel: Mini-Com® Fiber 8-Port DIN Rail Patch Panel: Mini-Com® Single Port DIN Rail Mount Adapter: CDPP8RG FDME8RG CADIN1IG^ IndustrialNet ™ TX6™ PLUS Patch Cords UTP with dust cap: UTP without dust cap Shielded with dust cap: Shielded without dust cap: IUTPSP3BL^^ IUTPSPNC3BL^^ ISTPSP1MBL^^^ ISTPSPNC1MBL^^^ TX6500™ Copper Cable Category 6, UTP:PUR6504BU-UY Suggested Allen-Bradley* Stratix** products, available from Rockwell Automation* 1783-MS10T Stratix 8000** switch 1783-MX08T Stratix 8000 copper expansion module 1783-MX08F Stratix 8000 fiber expansion module 1783-BMS10CGN Stratix 5700** 10-port switch with Network Address Translation (NAT) 1783-BMS20CGN Stratix 5700 20-port switch with NAT ^For standard colors other than International Gray, replace IG in part number with BL (Black), EI (Electric Ivory), IW (Off White), or WH (White). ^^For lengths other than 3 feet (5, 7, 10, 15, or 20 feet) change the length designation in the part number to the desired length. ^^^For lengths other than 1 meter (2, 3, or 5 meters) change the length designation in the part number to the desired length. Switch Ready Network Zone System Control Room Manufacturing Cell Zone Infrastructure Deploying Zone Network Topology A highly effective way to deploy EtherNet/IP*** solutions in a plant floor environment is to follow the recommendations from Rockwell Automation* and Cisco**** in their Converged Plantwide Ethernet (CPwE) design and implementation guide. In this guide the use of zoned network topology is recommended as a best practice. Using Panduit’s Network Zone System integrated with Stratix** switches from Rockwell Automation* provides a platform for implementing small VLANs for Cell/Area Zones, as recommended in the CPwE to improve manageability and limit Layer 2 broadcast domains‡. S S T A S C T K A 1 C K T A S C T K A 2 C K 1 2 C O NS C OL O E NS OL E Plant Level Zone R 10 1 .6 0A-A 0 24 .9 TA I , R 50010 N-60 VA 1 .6 0A-Z H G 0 24 .9 T~ A I , 500N-60 V HG ~Z Machine Level Zone A D C C A D C C A D C C The zone enclosures allow all cables within a Cell/Area Zone to be managed and patched within a single enclosure. By using a zone cabling architecture approach, network cabling becomes easier to locate, manage, and maintain because each additional device is routed within the same pathways and enclosures. Managed cabling helps reduce the number of home runs throughout a facility and helps reduce abandoned cable in plenum spaces, helping make the workplace run more efficiently and safely. Following a zone topology allows a highly scalable and flexible deployment using building blocks of the CPwE architecture. Switch Ready Network Zone Systems - More options available at www.panduit.com/networkzone Part number Layout Image Enclosure Type Z23R-S15 4/12 Steel Z23R-S15S 4/12 Steel Z23R-615 4X 316 SS Z23R-615S 4X 316 SS Z23R-S25 4/12 Steel Z23R-S25S 4/12 Steel Z23R-625 4X 316 SS Z23R-625S 4X 316 SS Z22R-S15 4/12 Steel Z22R-S15S 4/12 Steel Industrial Switch(es) (1) user defined industrial switch with max power of 35 watts at 24 Vdc Downlink Port Connectivity Provided (6) LC adaptors, (2) LC patch cords (16) Cat 6 STP jacks and cords (6) LC adaptors, (2) LC patch cords (16) Cat 6 UTP jacks and cords (6) LC adaptors, (2) LC patch cords (16) Cat 6 UTP jacks and cords 19" 48-port patch panel CPP48WBLY (16) Cat 6 UTP jacks and cords (6) LC adaptors, (4) LC patch cords (16) Cat 6 STP jacks and cords (6) LC adaptors, (4) LC patch cords (6) LC adaptors, (2) LC patch cords (6) LC adaptors, (2) LC patch cords (1) 8-port patch panel CDPP8RG Z22R-615 4X 316 SS Z22R-615S 4X 316 SS (8) Cat 6 STP jacks and cords (6) LC adaptors, (2) LC patch cords Z22R-S25 4/12 Steel (16) Cat 6 UTP jacks and cords (6) LC adaptors, (4) LC patch cords Z22R-S25S 4/12 Steel Z22R-625 4X 316 SS Z22R-625S 4X 316 SS (2) user defined industrial switches with max power of 35 watts at 24 Vdc (8) Cat 6 UTP jacks and cords (16) Cat 6 STP jacks and cords (16) Cat 6 UTP jacks and cords (16) Cat 6 STP jacks and cords Power Input Din Rail Mounting Cable Management Isolation Barrier Gland Plate 7 inch deep strain relief bar and adjustable ring managers Barrier to cover high voltage equipment on lower DIN rail One removable machinable gland plate (3) 16.7 inch long DIN rails (6) LC adaptors, (4) LC patch cords (6) LC adaptors, (4) LC patch cords (8) Cat 6 STP jacks and cords Panduit Industrial Network UPS (6) LC adaptors, (2) LC patch cords (16) Cat 6 STP jacks and cords (8) Cat 6 UTP jacks and cords (1) user defined industrial switch with max power of 35 watts at 24 Vdc Uplink Port Connectivity Provided (16) Cat 6 UTP jacks and cords (16) Cat 6 STP jacks and cords (2) user defined industrial switches with max power of 35 watts at 24 Vdc Downlink Patch Field No battery, maintenancefree UPS with remote management UPS003024024015; Estimated Hold Time = 7 minutes fully expanded with Load Sense Module UPS003LSM (one UPS and LSM per switch) 100-250 Vac Single Phase (6) LC adaptors, (2) LC patch cords (2) 16.7 inch long DIN rails (6) LC adaptors, (4) LC patch cords (2) 8-port patch panels CDPP8RG (6) LC adaptors, (4) LC patch cords (6) LC adaptors, (4) LC patch cords ‡ For additional reference see the Panduit Popular Configuration Drawing “Overview of Industrial Switch Deployment” PCD0001. Leveraging the Rockwell Automation* Integrated Architecture** technology simplifies switch configuration and integration while providing machine-based diagnostics and troubleshooting tools. Stratix** Industrial Ethernet Switches also leverage the Cisco**** operating system, bringing the world’s leading switching technology to the plant floor environment. Advanced switch feature sets include: STP/RSTP/MST, Resilient Ethernet Protocol (REP), Flexlinks, EtherChannel (link aggregation), QoS, IGMP snooping with querier, VLANs with trunking, IEEE 1588 PTP v2, IPv6 support, storm control with alarming, egress traffic shaping; compatible with Cisco**** Network Assistant (CNA) and CiscoWorks. *Rockwell Automation and Allen-Bradley are registered by Rockwell Automation in the Patent and Trademark Office of the United States. **Stratix, Stratix 8000, Stratix 5700 and Integrated Architecture are trademarks of Rockwell Automation. ***EtherNet/IP is a trademark of ODVA. ****Cisco is a registered trademark of Cisco Technology Inc. Switch Ready Network Zone System configuration options Z23R-S25 Z22R-S15 WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA Markham, Ontario [email protected] Phone: 800.777.3300 PANDUIT EUROPE LTD. London, UK [email protected] Phone: 44.20.8601.7200 PANDUIT SINGAPORE PTE. LTD. Republic of Singapore [email protected] Phone: 65.6305.7575 PANDUIT JAPAN Tokyo, Japan [email protected] Phone: 81.3.6863.6000 PANDUIT LATIN AMERICA Guadalajara, Mexico [email protected] Phone: 52.33.3777.6000 PANDUIT AUSTRALIA PTY. LTD. Victoria, Australia [email protected] Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information Visit us at www.panduit.com Contact Customer Service by email: [email protected] or by phone: 800.777.3300 ©2015 Panduit Corp. ALL RIGHTS RESERVED. ZCSP20--WW-ENG 10/2015