Datasheet

New Product
Remote Reset Rocker Switch
A8GS
Minimum size class in the industry Rocker switch with reset function
• Zero standby power by Reset function.
• High inrush-current durability.
Conforming to TV-8 rating. (Inrush 117A)
• Model variation for Micro loads.
• Model variation of micro load and high capacity combination. (DPST)
It is able to operate micro load and high capacity load at the same time.
• Contact gap of 3 mm minimum.
• UL and cUL standard approved, Conforming to EN standards.
• Model variation for 3.3VDC circuit.
RoHS Compliant
(Please refer the Precautions)
Usage example
Saving energy by cutting the standby power.
Saving energy by preventing forgetting to turn OFF main power.
Turning OFF main power by remote.
Turning OFF main power of many equipments at the same time.
* There are 2 kinds of main models A8GS. (Delay OFF Function model and Remote Reset model) With regard to the models with Delay OFF Function, please refer to the other catalog.
List of Models
1. Reset function type
SPST
Contact Form
1 to 2: Power contact terminal
a, b: Micro load contact terminal
+, -: Coil terminal
Terminals
No Marking
Marking on caps
Contact Form
1 to 2: Power contact terminal
a, b: Micro load contact terminal
+, -: Coil terminal
Terminals
Reset voltage
No Marking
Power contact terminal × 1
+
-
+
a
b
1
+
2
-
1
2
Quantity
per box
-
5V model
A8GS-S1105
3.3V model
A8GS-S1103
Quick-connect terminals
#187 (t=0.8)
5V model
3.3V model
A8GS-P1185
A8GS-P1183
A8GS-S1205
A8GS-S1203
A8GS-P1285
A8GS-P1283
A8GS-P1215
A8GS-P1213
A8GS-S1305
A8GS-S1303
A8GS-P1385
A8GS-P1383
A8GS-P1315
A8GS-P1313
CT Connector
Reset voltage
Marking on caps
Micro load contact terminal × 1
Solder terminals
5V model
A8GS-P1115
3.3V model
A8GS-P1113
50
DPST
Micro load contact terminal × 1 + Power contact terminal × 1
+
1
2
-
a
b
Quantity
per box
Micro load contact terminal : CT Connector
Micro load contact terminal : CT Connector
Power contact terminal : Quick-connect
Power contact terminal : Solder terminals
terminals #187 (t=0.8)
5V model
3.3V model
5V model
3.3V model
A8GS-C1185
A8GS-C1183
A8GS-C1115
A8GS-C1113
A8GS-C1285
A8GS-C1283
A8GS-C1215
A8GS-C1213
A8GS-C1385
A8GS-C1383
A8GS-C1315
A8GS-C1313
50
1
A8GS
DPST
Power contact terminal × 2
Contact Form
1 to 4: Power contact terminal
+, -: Coil terminal
Terminals
Reset voltage
No Marking
Marking on caps
+
1
2
-
3
4
Quantity
per box
Quick-connect terminals
#187 (t=0.8)
5V model
3.3V model
A8GS-D1185
A8GS-D1183
5V model
A8GS-D1115
3.3V model
A8GS-D1113
A8GS-D1285
A8GS-D1283
A8GS-D1215
A8GS-D1213
A8GS-D1385
A8GS-D1383
A8GS-D1315
A8GS-D1313
Solder terminals
50
Note: 1. [ V ] is shown at the end of model name for TV-8 approved models. (Example : A8GS-P1185V, A8GS-C1185V, A8GS-D1185V)
Note: 2. TV-8 approved model is only for Power switch circuit.
Note: 3. [ 3 ] is shown at the end of model name for reset voltage 3.3 VDC models. (Example : A8GS-P1183).
[ 5 ] is shown at the end of model name for reset voltage 5 VDC models. (Example : A8GS-P1185).
2. Without Reset function type
SPST
Contact Form
1 to 4: Power contact terminal
a, b: Micro load contact terminal
Micro load contact
terminal × 1
1
a
Terminals
No Marking
Contact Form
1 to 2 Power contact terminal
a, b: Micro load contact terminal
Terminals
No Marking
Power contact terminal × 2
2
b
A8GS-S1100
Quick-connect
terminals
#187 (t=0.8)
A8GS-P1180
A8GS-S1200
A8GS-P1280
A8GS-S1300
A8GS-P1380
CT Connector
Marking on caps
DPST
Power contact terminal × 1
1
2
3
4
A8GS-P1110
Quick-connect
terminals
#187 (t=0.8)
A8GS-D1180
A8GS-D1110
A8GS-P1210
A8GS-D1280
A8GS-D1210
A8GS-P1310
A8GS-D1380
A8GS-D1310
Solder
terminals
Solder
terminals
DPST
Micro load contact terminal × 1 + Power contact terminal × 1
1
2
a
b
Quantity
per box
Micro load contact terminal : CT Connector
Micro load contact terminal : CT Connector
Power contact terminal : Quick-connect
Power contact terminal : Solder terminals
terminals #187 (t=0.8)
A8GS-C1180
A8GS-C1110
Marking on caps
A8GS-C1280
A8GS-C1210
A8GS-C1380
A8GS-C1310
50
Note: 4. These models are without reset function, it has same function with standard Rocker switch.
Ratings
Contact Ratings
Power contact terminal
Rated voltage
Rated current
(Resistive load)
125 VAC
16 A
250 VAC
10 A
Micro load contact terminal
5 VDC
0.2 A
Note: 1. The above ratings were tested under the following conditions:
(1) Ambient temperature : 20 ± 2 °C
(2) Ambient humidity
: 65 ± 5 % RH
(3) Switching frequency : 7 times/min
Reset Coil Ratings
Model
Rated voltage,
current
Operating
voltage range
Rated usage cycle
Coil resistance
(Coil temperature: 20 ± 2 °C)
Reset voltage : 5V model
(A8GS-@@@@5)
5VDC 455 mA
4.5 to 5.5 VDC
ON: 50 to 100 ms
OFF: Min 5 sec
11 Ω ± 20 %
ON: 50 to 100 ms
Reset voltage : 3.3V model
11 Ω ± 20 %
3.3VDC 300 mA
3.0 to 3.6 VDC
OFF: Min 5 sec
(A8GS-@@@@3)
Note: 1. Voltage for coil should be set within operating voltage range and applied time should be within rated usage cycle.
Otherwise the performance of the coil may be deteriorated.
Note: 2. In case of applying voltage within the range from 5.5 to 24 VDC to the coil, contact your OMRON sales representative.
2
Quantity
per box
50
A8GS
Contact specifications
Micro load contact
Power contact
Gold alloy
Silver alloy
3 mm
3 mm
Material
Contact gap
Minimum applicable
3 VDC 1 mA
5 VDC 200 mA
load (Reference value) *
* Please refer to ''Using Micro loads'' in ''Precautions''(P6) for more information on the minimum applicable load.
Characteristics
Permissible operating Mechanical
frequency
Electrical
Switch operation: 20 times/min max, Coil operation: 7 times/min max
Insulation resistance
100 MΩ min (at 500 VDC with insulation tester)
Contact resistance
(initial value)
Dielectric strength
Vibration resistance *
Shock resistance *
7 times/min max
Power contact terminal
100 mΩ max (6 VDC to 8 V, 1 A Voltage drop method)
Micro load contact terminal
100 mΩ max (6 VDC to 8 V, 0.1 A Voltage drop method)
Between terminals of the
same polarity
AC2,000 V 50/60 Hz 1 min
Between terminals of the
different polarity
AC2,000 V 50/60 Hz 1 min
Between each terminals of the
switch and terminals of coil
AC4,000 V 50/60 Hz 1 min
Between each terminals of
switch and ground
AC4,000 V 50/60 Hz 1 min
Malfunction
10 to 55 Hz 1.5 mm double amplitude (Malfunction within 1 ms)
Malfunction
300 m/s2 min (Malfunction within 1 ms)
Destruction
1000 m/s2 max
−10 to +55 °C (with no icing or condensation, 60 % RH max)
Ambient operating temperature
90 %RH max (+5 to 35 °C with no icing or condensation)
Ambient operating humidity
Mechanical
Durability
Switch operation: 30,000 operations min, Coil operation: 10,000 operations min
Electrical
Switch operation: 10,000 operations min
Inrush current
117 A max.
Degree of protection
IEC IP40
Contact release time **
100 ms max
Weight
A8GS-Sxxxx: around 9 g
A8GS-Pxxxx: around 10 g
A8GS-Cxxxx: around 11 g
A8GS-Dxxxx: around 12 g
Note: 1. Above specification values are initial values.
*For the testing condition in individual specification, contact your OMRON sales representative.
**Time from voltage applied to reset coil to actual contacts opening.
Approved Safety Standards
UL (UL61058-1)
TÜV (EN61058-1)
Approved safety
standards ratings
TV-8
approved ratings *
16 A 125 VAC
Power contact terminal
TV-8
10 A 250 VAC
Approved safety
standards ratings
TV-8
approved ratings *
Power contact terminal
10 (4) A 250 VAC
8/128 A 250 VAC
Micro load contact terminal
0.2 A 5 VDC
0.2 A 5 VDC
Micro load contact terminal
−
−
Note: 1. Approved safety standard ratings for Signal Switch Circuit is only for 'A8GS-Cxxxx' model. 'A8GS-Sxxxx' model is not approved.
*These ratings are only for TV-8 rating approved models.
Connector for Signal Switch Circuit and Coil Circuit
CT connectors produced by Tyco Electronics Corporation or XR connectors produced by JST shall be used
for connection of Signal and Coil circuit. Other connectors shall not be used.
Tyco Electronics Corporation: CT connecter
Pressure welding type
Micro load
contact terminal
Coil terminal
Connector
Terminal no.
Connection with
Switch
1
a (Switch COM)
2
---
3
b (Switch NO)
1
+ (Coil)
2
- (Coil)
Housing
Contact
AWG #30-26
AWG #26-22
179609-1
179227-1
179228-3
179228-2
Cramping type
JST: XR Connector
AWG #28-26
AWG #24
AWG #28-26
173977-3
2-179694-3
3XR-6@-P*
173977-2
2-179694-2
2XR-6@-P*
* @ indicates Housing color.
3
A8GS
Operation
Remote Reset Function
Button is operated for turning OFF of Power and Micro load contact terminal by applying external signal to coil.
Manual Operation
Power and Micro load contact terminal are operated to turn ON/OFF by manual, same as standard Rocker switch.
OFF
Button operating
condition
Power / Micro load
contact terminal
(1) Manual ON
OFF
(2) Manual OFF
ON
OFF
Remote Reset Function Operation
It is able to turn OFF Power and Micro load contact terminal from manual ON condition by applying voltage to coil.
OFF
Button operating
condition
Power / Micro load
contact terminal
(1) Manual ON
OFF
(3) Remote Reset
ON
Coil terminal
Button is
returned
automatically.
OFF
No voltage applied
No voltage applied
Voltage applied
Switch circuit and operating condition
OFF
+
(1) Manual ON
1
2
3
4
+
Load
1
2
3
4
(2) Manual OFF
+
Load
1
2
3
4
(3) Remote Reset
+
Load
-
-
-
-
Power
supply
Power
supply
Power
supply
Power
supply
1
2
3
4
* 5VDC applied to coil terminal
Note: 1. The above circuit is referring to the 'A8GS-Dxxxx' model.
4
Load
A8GS
30
14.9
A8GS-P1@85
A8GS-P1@15*
A8GS-P1@83
A8GS-P1@13*
17
A8GS-S1@05
A8GS-S1@03
17
Dimensions (Unit: mm) /Operating Characteristics
12.2
OFF
6. 9
12.2
OFF
28.5
2
28. 5
2
6.8
ON
14.9
30
ON
1.3
27
CT Connector
1.0 ± 0.6 N
0.8
1.5 ± 0.9 N
30
14.9
14.9
12.2
OFF
ON
OFF
12.2
28.5
28. 5
2
2
6.8
6. 9
ON
17
A8GS-D1@ 85
A8GS-D1@ 15*
A8GS-D1@ 83
A8GS-D1@ 13*
30
14.3
CT Connector
Operating force (OF)
17
A8GS-C1@85
A8GS-C1@ 15*
A8GS-C1@ 83
A8GS-C1@13*
10
27
CT Connector
Operating force (OF)
4.75
14.3
1.3
4.75
10
0.8
11.5±0.8
14.3
CT Connector
CT Connector
2.0 ± 1.2 N
Operating force (OF)
2.0 ± 1.2 N
Accessories parts (Sold Separately)
Protector can improve resistance against external force to
the actuator from side (angled) direction.
17
A8GS-@@@@0
(No reset function model)
4.75
10
27
CT Connector
Operating force (OF)
1.3
0.8
14.3
27
30
14.9
12.2
OFF
6. 8
ON
Protector
Model: A8GS-211(P)
Color: Black
Mounting image
28. 5
2
8.8
27
14.3
22.5
33.6
• The above model is referring the 'A8GS-S1100'.
• No reset function models are without coil circuit.
• Specifications are same with reset function models.
Note: 1. Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions.
Note: 2. When initial operation or operation after reset, operating force is increased, due to switch structure.
Note: 3. TV-8 approved models are same outline and characteristics with standard models.
* Solder terminals model has different hole shape, compare with Quick-connect terminals. Outline and characteristics are same.
5
A8GS
Panel Cutout
Panel thickness: 0.8 to 2.3 mm
26.5 ±0.1
R by cutting
15.2 ±0.1
The rollover of the panel shall be on the front face.
And panel back side shall be Edge shape by processing.
OFF
3.95 ±0.1
1.9 ±0.1
Panel cutout design is for prevention of false insertion.
Please be careful about the direction of the protrusion.
27.7 ±0.1
ON
Edge
(Operating surface direction)
Note: 1. Recommendation panel material is "SPCC", however, in case of soft material or Panel back side shape is not edge,
mounting strength may down. Please check and try by actual mounting panel and set the Panel thickness and hole dimension.
Precautions
WARNING
Do not wire the switch or touch any terminal of the
Switch while power is being supplied. Or it may result in
electric shock.
•Handling
• Do not apply excessive operating force to the switch.
• Do not drop or apply the excessive shock.
Otherwise the switch may be damaged or deformed.
• Do not impose force to operating part from an angle, Otherwise the
switch may be damaged or deformed.
Cautions
Use the switch within the rated voltage and current ranges, otherwise
the switch may have deteriorated durability. Radiate heat, or burn out.
This particularly applies to the instantaneous voltages and currents
when switching.
Caution of usage
•Mounting
• Easy to mount by snap fitting.
• Do not impose excessive force on switch at the time of panel mounting.
• Do not detach the switch after installed. Otherwise, the holding
strength may be loose.
• Apply the force to housing when installing to panel. Do not apply
the force to the button (rocker) part when installing to the panel.
Pushing position
Correct
Incorrect
•Environment for storage and use
• To prevent the terminals color change and others while storage,
Do not keep for a long term in the following conditions.
(1) High temperature, high humid environment
(2) Corrosive gas
(3) The place where the direct rays of the sun
(4) The place where the sea breeze
(5) Environmental with a sudden temperature change
This switch is not sealed to prevent from entering dust and liquid.
Do not use under dust and liquid condition.
• Switch shall not be icing or condensation.
• Strong magnetic field may cause malfunction.
Check function is recommended under practical use conditions.
•Using Micro Loads
•Wiring
• Confirm the size of the receptacles and be sure to connect them firmly.
• Use an appropriate wire allowable to carry current.
• Be sure that there is no mechanical stress on terminals and coil terminals.
Otherwise, the switch may malfunction and/or damaged.
(Example: Too strong wiring)
In case of using the switch under the micro loads, please refer the
Minimum applicable load and set the load more than minimum
applicable load.
Even when using micro load within the operating range, if inrush
current occurs, it may increase contact wear and so deteriorate
durability. Therefore, insert a contact protection circuit where
necessary.
The minimum applicable load is the L-level reference value.
This value indicates the malfunction reference level for the
reliability level of 60 %. (λ 60)
• Take appropriate insulation distance between switch terminal and
other metal parts after wiring.
• Coil has polarity, please confirm polarity when wiring.
• Do not apply continuous voltage more than 10 seconds at any
time. Otherwise, insulation deterioration may occur by heat of coil.
Please consider the circuit design.
• Reverse voltage may cause of accurate discrete semiconductor
devices. In case of controlling by accurate discrete semiconductor
devices, Please consider the circuit design. (Example : add the
surge absorbing circuit)
• In case of manual soldering, soldering time is max 4 sec by soldering
iron (Max 350 °C at the iron tip) and do not add the stress to terminals.
• In case of touching the soldering iron to the root of terminals, it may
cause Housing parts melt.
6
The equation, λ 60 = 0.5 x 10-6 /operations indicates that the
estimated malfunction rate is less than 1/2,000,000 operations with
a reliability level of 60 %.
•RoHS Compliant
The "RoHS Compliant" designation indicates that the listed models
do not contain the six hazardous substances covered by the RoHS
Directive.
Reference: The following standards are used to determine
compliance for the six substances.
Lead
: 1,000 ppm max.
Mercury
: 1,000 ppm max.
Cadmium
: 100 ppm max.
Hexavalent chromium : 1,000 ppm max.
PBB
: 1,000 ppm max.
PBDE
: 1,000 ppm max.
MEMO
7
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. A222-E1-03
1014(0313)(O)