Datasheet

Photomicrosensor (Transmissive)
EE-SX461-P11
Be sure to read Precautions on page 24.
■ Dimensions
■ Features
Note: All units are in millimeters unless otherwise indicated.
•
•
•
•
•
171826-3 (Tyco
Electronics AMP)
Snap-in-mounting model.
Mounts to 0.8- to 1.6-mm-thick panels.
With a 15-mm-wide slot.
Photo IC output signals directly connect with C-MOS and TTL.
Connects to Tyco Electronics AMP’s EI-series connectors.
■ Absolute Maximum Ratings (Ta = 25°C)
Item
2 (Aperture
width)
Optical
axis
Two, R1
Symbol
Rated value
Power supply voltage
VCC
7V
Output voltage
VOUT
28 V
Output current
IOUT
16 mA
Permissible output dissipation
POUT
250 mW
(see note)
Ambient temper- Operating
ature
Storage
Topr
–20°C to 75°C
Tstg
–40°C to 85°C
Soldering temperature
Tsol
---
(15)
Note: Refer to the temperature rating chart if the ambient temperature exceeds 25°C.
Internal Circuit
V
Unless otherwise specified, the
tolerances are as shown below.
O
G
Dimensions
3 mm max.
Terminal No.
V
O
G
Name
3 < mm ≤ 6
Tolerance
±0.3
±0.375
Power supply
(Vcc)
6 < mm ≤ 10
±0.45
Output (OUT)
Ground (GND)
10 < mm ≤ 18
±0.55
18 < mm ≤ 30
±0.65
Recommended Mating Connectors:
Tyco Electronics AMP 171822-3 (crimp connector)
172142-3 (crimp connector)
OMRON
EE-1005 (with harness)
■ Electrical and Optical Characteristics (Ta = 25°C, VCC = 5 V±10%)
Item
Symbol
Current consumption
Value
ICC
35 mA max.
Condition
With and without incident
Low-level output voltage
VOL
0.3 V max.
IOUT = 16 mA with incident
High-level output voltage
VOH
(VCC x 0.9) V min.
VOUT = VCC without incident, RL = 47 kΩ
Response frequency
f
3 kHz min.
VOUT = VCC, RL = 47 kΩ (see note)
Note: The value of the response frequency is measured by
rotating the disk as shown below.
Disk
2.1 mm
2 mm
56
2 mm
t = 0.2 mm
EE-SX461-P11 Photomicrosensor (Transmissive)
■ Engineering Data
Sensing Position Characteristics
(Typical)
d2 = 0±1.1 mm
Output transistor
Light interrupting plate
Center of optical axis
VCC = 5 V
Ta = 25°C
RL = 47 kΩ
d
OFF
d2
ON
−3
Ambient temperature Ta (°C)
Center of optical axis
Sensing Position Characteristics
(Typical)
VCC = 5 V
Ta = 25°C
RL = 47 kΩ
d1 = 0±1.1 mm
Output transistor
Output allowable dissipation Pc (mW)
Output Allowable Dissipation vs.
Ambient Temperature Characteristics
−2
−1
0
1
2
3
Distance d (mm)
Distance d (mm)
EE-1005 Connector
1,000±20
(1) (2)
No.
(3)
Name
Model
Quantity
Maker
Wiring
1
Receptacle
housing
171822-3
1
Tyco Electronics
AMP
2
Receptacle
contact
170262-1
3
Tyco Electronics
AMP
1
Red
VCC
3
Lead wire
UL1007 AWG24
3
---
2
Orange
OUT
3
Yellow
GND
Connector
circuit no.
Lead wire color
Output when connected to
EE-SX461-P11
■ Recommended Mounting Hole Dimensions and Mounting and Dismounting Method
Dismounting by Hand
Squeeze the mounting tabs as shown in the following illustration and
press the mounting tabs upwards.
Optical axis
Sensor edge
(to post header)
Center of
sensing
slot
EE-SX461-P11
Sensor edge
(2)
The Photomicrosensor can be mounted to 0.8- to 1.6-mm-thick
panels.
Refer to the above mounting hole dimensions and open the
mounting holes in the panel to which the Photomicrosensor will be
mounted.
Insert into the holes the Photomicrosensor’s mounting portions with
a force of three to five kilograms but do not press in the
Photomicrosensor at one time. The Photomicrosensor can be easily
mounted by inserting the mounting portions halfway and then slowly
pressing the Photomicrosensor onto the panel.
There are two ways to dismount the Photomicrosensor. Refer to the
following.
Dismounting with Screwdriver
Press the mounting hooks of the Photomicrosensor with a flat-blade
screwdriver as shown in the following illustration and pull up the
Photomicrosensor.
Panel
(1)
(1)
Pressed mounting holes are ideal for mounting the
Photomicrosensor. When mounting the Photomicrosensor to a panel
that has pressed mounting holes for the Photomicrosensor, be sure
to mount the Photomicrosensor on the pressing side of the panel,
otherwise it may be difficult to mount the Photomicrosensor and an
insertion force of five to six kilograms may be required.
When mounting the Photomicrosensor to a panel that has mounting
holes opened by pressing, make sure that the mounting holes have
no burrs, otherwise the lock mechanism of the Photomicrosensor will
not work perfectly. After mounting the Photomicrosensor to a panel,
be sure to check if the lock mechanism is working perfectly.
EE-SX461-P11
EE-SX461-P11
Flat-blade
screwdriver
(2)
(2)
(1)
Mounting hook
Flat-blade
screwdriver
(1)
Panel
Mounting hook
This tapered portion must be on
the lower side of the panel,
otherwise the Photomicrosensor
will not be locked in.
Panel
Mounting tab
EE-SX461-P11 Photomicrosensor (Transmissive)
57