Downloads for Isolation Power Transformers (N-51X)

P OWER TRANSFORMER
CHASSIS MOUNT : Isolation
N-51X
Electrical Specifications (@25°C)
1. Maximum Power:
35 VA
2. Input Voltage:
115 V, 50 / 60 Hz
3. Output Voltage:
115V + 5%
4. Full Secondary Load: 0.30 Amps RMS
5. Voltage Regulation: 15 % TYP @ full load to no load
Description:
BLK
BLK
The N-51X is power transformer for isolating equipment from direct connection to the
power line. It is constructed with nonconcentrically wound coils. The primary and
secondary are wound on separate arbors, then assembled on a laminate core
side-by-side separated by insulation. This prevents electrical connection under
normal or overload conditions between the primary and secondary windings.
A
Safety:
WHT
These units are designed with 1500V isolation between winding to winding and
between winding and core. Materials and construction are rated for Class B
insulation system.
B
D
Unit: In inches
D
2.281
3.687
2.125
3.125
C
Weight: 1.70 lbs
Connections: 7.0±1” leads, 0.250±0.062” Skin & Tin
Schematic:
BLK
RED
BLK
RED
RED
C
RED
B
2 HOLES
A
.187 DIA (REF)
Dimensions:
WHT
Input: Blk to Blk
Output: Red to Red
Shield: Wht
RoHS Compliance: As of manufacturing date February 2005, all standard
products meet the requirements of 2002/95/EC, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact
Triad Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd
Perris, California
92571
Publish Date: December 04, 2013