pdf

QUICKTRONIC FIT T8
osram.com
QUICKTRONIC FIT T8
QT-FIT8
ECG for T8/ 26mm linear fluorescent
lamps
QT-FIT8
LUMILUX® T8
GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
01
QUICKTRONIC FIT T8
Product Features:
50.000 hours lifetime with max. failure rate of 10%
Lamp start with optimized filament preheating within 2 sec.
Suitable for lighting with high switching cycles
Reliable lamp ignition between -15°C...+50°C
Suitable for luminaries of protection class I
CELMA Energy-Efficiencies-Index A2
Automatic safety shut-down in case of a defect or at the end of the lamp’s life (EoL T.2)
Automatic restart after lamp replacement
Suitable for emergency installations (DC, 0 Hz)
Technical Data
Max. cable diameter for
2
push-in contact [mm ]:
1
s : 0.5 - 1.5
Starting time:
t: 2 sec.
Line voltage:
220 - 240 V
Voltage range (AC):
198 - 264 V
Voltage range (DC):
185 - 264 V; for lamp ignition min. 198 V; max. 1 hour 185 - 198V
Line frequency:
50 - 60 Hz
Operating frequency:
40 - 50 kHz
Electrical strength:
Ambient temperature ta:
Measuring point temperature tc:
U-OUT:
1
280 V  permanent; 300 V  2 hours
-15 °C to +50 °C
Max. +70 °C
430 V
s = solid wire
GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
02
QUICKTRONIC FIT T8
Inrush current and max. number of ECG per circuit breaker
ECG
QT-FIT8
QT-FIT8
QT-FIT8
QT-FIT8
QT-FIT8
QT-FIT8
QT-FIT8
QT-FIT8
Inrush Current
Ip [A]
15
15
15
15
15
15
15
15
1x18
2x18
3x18, 4x18
1x36
2x36
3x36
1x58-70
2x58-70
Max. number of ECG per circuit breaker
TH [µs]
200
200
200
200
200
200
200
200
B: 10A
17
17
8
17
8
8
17
8
C: 10A
13
28
-
B: 16A
28
28
13
28
13
13
28
13
C: 16 A
49
49
22
49
22
22
49
22
Standards and approval marks
Safety:
acc. to EN 61347-2-3 / IEC 61347-2-3
Radio interference:
acc. EN 55015: 2006 + A1: 2007 + A2: 2009
Harmonic content:
acc. to EN 61000-3-2 / IEC 61000-3-2
Immunity:
acc. to EN 61547 / IEC 61547
Approval marks:
Dimensions & weight
Description
Description
Length
[mm]
Width
[mm]
Height
[mm]
Distance
Mounting
Holes [mm]
Weight [g]
QT-FIT8 1x18
280
30
28
270
260
QT-FIT8 2x18
360
30
28
350
350
QT-FIT8 3x18, 4x18
280
40
28
270
370
QT-FIT8 1x36
280
30
28
270
270
QT-FIT8 2x36
360
30
28
350
350
QT-FIT8 3x36
280
40
28
270
390
QT-FIT8 1x58-70
280
30
28
270
280
QT-FIT8 2x58-70
360
30
28
350
350
GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
03
QUICKTRONIC FIT T8
Lamp wiring
QT-FIT8 1x…
Max. permitted cable length in between ECG and lamp: 2.0 m (PIN 21, 22); 1.0 m (PIN 23, 24)
QT-FIT8 2x...
Max. permitted cable length in between ECG and lamp: 2.0 m (PIN 21, 22); 1.5 m (PIN 23, 24); 1.0 m (PIN 25,
26)
QT-FIT8 3x18, 4x18, QT-FIT8 3x36 – 3 lamp operation
QT-FIT8 3x18, 4x18
QT-FIT8 3x36
Max. permitted cable length in between ECG and lamp: 1.0 m (PIN 25, 26); 1.5 m (PIN 4, 5, 21, 22, 23, 24)
GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
04
QUICKTRONIC FIT T8
QT-FIT8 3x18, 4x18 – 4 lamp operation
QT-FIT8 3x18, 4x18
Max. permitted cable length in between ECG and lamp: 1.0 m (PIN 6, 7, 25, 26); 1.5 m (PIN 4, 5, 21, 22, 23, 24)
Logistic Data
Description
EAN 10
EAN 40
Packaging Unit
QT-FIT8 1x18
4008321294180
4008321294197
20
QT-FIT8 2x18
4008321294241
4008321294258
20
QT-FIT8 3x18, 4x18
4008321294302
4008321294319
20
QT-FIT8 1x36
4008321294203
4008321294210
20
QT-FIT8 2x36
4008321294265
4008321294272
20
QT-FIT8 3x36
4008321512055
4008321512062
20
QT-FIT8 1x58-70
4008321294227
4008321294234
20
QT-FIT8 2x58-70
4008321294289
4008321294296
20
Lifetime
Measuring point
temperature tc:
70 °C
Lifetime
with max. 10% failure rate
50,000 h
GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
05
QUICKTRONIC FIT T8
Lamp/ECG System Combination
ECG
QT-FIT8 1x18
QT-FIT8 2x18
QT-FIT8 3x18, 4x18
QT-FIT8 1x36
QT-FIT8 2x36
QT-FIT8 3x36
QTP8 1x58-70
QTP8 2x58-70
Lamp
L18
2
L16 ES
2x L18
2
2x L16 ES
3x L18
2
3x L16 ES
4x L18
2
4x L16 ES
L36
2
L32 ES
2x L36
2
2x L32 ES
3x L36
2
3x L32 ES
L58
L70
2
L 51 ES
2x L58
2x L70
2
2x L 51 ES
HF lamp
wattage [W]
16
14.2
2x16
2x14.2
3x16
3x14.2
4x16
4x14.2
32
29
2x32
2x29
3x32
3x29
50
57
44.5
2x50
2x57
2x44.5
System
wattage [W]
19
17.2
36
32.4
54
47.1
74
64
36
32
71
64
105
100
54
62
50
109
124
96
Line current [A]
0.09
0.08
0.16
0.14
0.25
0.21
0.33
0.28
0.16
0.15
0.32
0.30
0.48
0.43
0.24
0.28
0.23
0.48
0.55
0.43
Luminous flux at
25°C [lm]
1350
1100
2x 1300
2x 1100
3x 1350
3x 1100
4x 1350
4x 1100
3200
2500
2x 3200
2x 2500
3x 3500
3x 2500
5000
5900
4200
2x 5000
2x 5900
2x4200
Luminous flux at
35°C [lm]
-
Power factor
[λ]
0.95
0.90c
0.98
0.97
0.97
0.98
0.99
0.98
0.96
0.93c
0.98
0.97
0.99
0.99
0.96
0.96
0.96
0.98
0.98
0.98
For more information on ECG refer to http://www.osram.com/ecg
For more information on System Guarantee refer to http://www.osram.com/guarantee
2
Additional Lamp-ballast combination without ENEC; ta = +10 °C to +50 °C
GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
06