QUICKTRONIC PROFESSIONAL QTP8 osram.com QUICKTRONIC PROFESSIONAL QTP8 ECG for T8/26mm fluorescent lamps QTP8 ® LUMILUX T8 GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 01 QUICKTRONIC PROFESSIONAL QTP8 Product Features: Up to 100.000 hours lifetime1 Lamp start with optimised filament preheating within 2 sec. Reliable lamp ignition between -25°C ...+55°C Suitable for luminaires of PC I + II Constant light output for UN = 198V ... 264V CELMA energy classification EEI = A2 Automatic safety shut down at lamp failure Automatic restart after lamp replacement Suitable for emergency installations (DC operation) Technical Data Max. cable diameter for IDC-contakt [mm2]: s2: 0.5; s-f3: 0.75 Max. cable diameter for push-in contact [mm2]: s2: 0.5...1.0 Starting time: t < 2 sec. Line voltage: 230 - 240 V Voltage range (AC): 198 - 264 V Voltage range (DC): 154-276 V; min. 198 V for lamp ignition Line frequency: 0, 50 - 60 Hz Operating frequency: 45 - 60 kHz Electrical strength: 300 V permanent Ambient temperature ta: -25 °C to +55 °C Measuring point temperature tc: Max. +75 °C U-OUT: 380 V 1 at T = 65°C @ Tc. 50.000 h with max. 10% failure rate at tc = 75°C max s = stranded wire 3 s-f = stranded-flexible wire 2 GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 02 QUICKTRONIC PROFESSIONAL QTP8 Inrush current and max. number of ECG per circuit breaker ECG QTP8 QTP8 QTP8 QTP8 QTP8 QTP8 QTP8 QTP8 Inrush Current Ip [A] 14 17 20 20 17 20 20 28 1x18 2x18 3x18 4x18 1x36 2x36 1x58 2x58 Max. number of ECG per circuit breaker TH [µs] 140 155 210 210 155 210 210 230 C: 10A 36 25 17 17 25 17 17 8 B: 16A 59 41 28 28 41 28 28 13 C: 16 A 101 69 47 47 69 47 47 20 Standards and approval marks Safety: acc. to EN 61347-2-3 / IEC 61347-2-3 Radio interference: acc. EN 55015: 2006 + A1: 2007 + A2: 2009 Harmonic content: acc. to EN 61000-3-2 / IEC 61000-3-2 Immunity: acc. to EN 61547 / IEC 61547 Approval marks: Dimensions & weight Description Description Length [mm] Width [mm] Height [mm] Distance Weight [g] Mounting Holes [mm] QTP8 1x18 360 30 30 350 270 QTP8 2x18 423 30 30 415 404 QTP8 3x18 423 40 30 415 500 QTP8 4x18 423 40 30 415 500 QTP8 1x36 360 30 30 350 261 QTP8 2x36 423 30 30 415 404 QTP8 1x58 360 30 30 350 309 QTP8 2x58 423 30 30 415 400 GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 03 QUICKTRONIC PROFESSIONAL QTP8 Lamp wiring QTP8 1x… QTP8 1x Max. permitted cable length in between ECG and lamp: 2.0 m (PIN 21, 22); 1.5 m (PIN 26, 27) QTP8 2x… QTP8 2x Max. permitted cable length in between ECG and lamp: 3.0 m (PIN 21, 22, 23); 1.5 m (PIN 24, 25, 26, 27) QTP8 3x18, 4x18 – 3 lamp operation QTP8 3x18, 4x18 Max. permitted cable length in between ECG and lamp: 1.0 m (PIN 22, 23, 27, 28); 1.5 m (PIN 4, 5, 6, 7, 24, 25, 26) GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 04 QUICKTRONIC PROFESSIONAL QTP8 QTP8 3x18, 4x18 – 4 lamp operation QTP8 3x18, 4x18 Max. permitted cable length in between ECG and lamp: 1.0 m (PIN 22, 23, 27, 28); 1.5 m (PIN 4, 5, 6, 7, 24, 25, 26) Logistic Data Description EAN 10 EAN 40 Packaging Unit QTP8 1x18 4008321131584 4008321131591 20 QTP8 2x18 4008321131607 4008321131614 20 QTP8 3x18 4008321131706 4008321131713 20 QTP8 4x18 4008321131706 4008321131713 20 QTP8 1x36 4008321131621 4008321131638 20 QTP8 2x36 4008321131645 4008321131652 20 QTP8 1x58 4008321131669 4008321131676 20 QTP8 2x58 4008321131683 4008321131690 20 Lifetime Measuring point temperature tc: Lifetime with max. 10% failure rate 75 °C 50,000 h 65 °C 100,000 h GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 05 QUICKTRONIC PROFESSIONAL QTP8 Lamp/ECG System Combination ECG QTP8 QTP8 QTP8 QTP8 Lamp 1x18 2x18 3x18 4x18 QTP8 1x36 QTP8 2x36 QTP8 1x58 QTP8 2x58 L18 2x L18 3x L18 4x L18 L36 L38 2x L36 2x L38 L58 2x L58 HF lamp wattage [W] 16 2x16 3x16 4x16 32 32 32 32 50 2x50 System wattage [W] 18 35 56 73 35 35 71 71 55 110 Line current [A] 0.09 0.17 0.26 0.32 0.16 0.16 0.31 0.31 0.24 0.45 Luminous flux at 25°C [lm] 1300 2x1300 3x1300 4x1300 3200 3200 2x3200 2x3200 5000 2x5000 Luminous flux at 35°C [lm] - Power factor [λ] 0.96 0.97 0.99 0.99 0.96 0.96 0.96 0.96 0.98 0.98 For more information on ECG refer to http://www.osram.com/ecg For more information on System Guarantee refer to http://www.osram.com/guarantee GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 06