QUICKTRONIC FIT QT-FIT5/8

QUICKTRONIC fit T5/T8
osram.com
QUICKTRONIC FIT
QT-FIT5/8
ECG for T5/16mm and T8/26mm linear
fluorescent lamps
QT- FIT5/8
®
i.e. LUMILUX T5
LE MK-EM T-ECG 13 Edition:.06.2013. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
01
QUICKTRONIC fit T5/T8
Product Features:









50,000 hours lifetime1
Lamp start with optimized filament preheating within 2 s
Suitable for lighting with very high switching cycles
Reliable lamp ignition between -15°C...+50°C
Suitable for luminaries of protection class I
CELMA Energy Efficiency Index A2
Automatic safety shut-down in case of a defect or at the end of the lamp’s life (EoL T.2)
Automatic restart after lamp replacement
Suitable for DC installations
Technical Data
Max. cross section
push-in contact [mm2]:
s2: 0.5 - 1.5
Starting time:
< 2 sec.
Line voltage:
220 - 240 V
Voltage range (AC):
198 - 264 V
Voltage range (DC):
185 – 276 V; for lamp ignition min. 198 V; max. 1 hour 185 - 198V
Line frequency:
Operating frequency:
Electrical strength:
Ambient temperature ta:
Measuring point temperature tc:
U-OUT:
1
2
50 - 60 Hz
40 - 50 kHz
280 V  permanent; 300 V  2 hours
-15°C to +50 °C
Max. +75 °C
430 V
Average lifetime
s = solid wire
LE MK-EM T-ECG 13 Edition:.06.2013. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
02
QUICKTRONIC fit T5/T8
Inrush current and max. number of ECG per circuit breaker
ECG
QT- FIT5/8
QT- FIT5/8
QT- FIT5/8
QT- FIT5/8
Inrush Current
1x18-39
2x18-39
1x54-58
2x54-58
Max. number of ECG per circuit breaker
Ip [A]
TH [µs]
24
40
24
53
230
200
230
200
B: 10A
17
12
17
8
B: 16A
C: 16 A
28
19
28
13
47
32
47
22
Standards and approval marks
Safety:
acc. to EN 61347-2-3 / IEC 61347-2-3
Radio interference:
acc. EN 55015: 2006 + A1: 2007 + A2: 2009
Harmonic content:
acc. to EN 61000-3-2 / IEC 61000-3-2
Immunity:
acc. to EN 61547 / IEC 61547
Approval marks:
Dimensions & weight
Description
Description
Length
[mm]
Width
[mm]
Height
[mm]
Distance
Mounting
Holes [mm]
Weight [g]
QT- FIT5/8 1x18-39
280
30
21
270
160
QT- FIT5/8 2x18-39
QT- FIT5/8 1x54-58
280
280
30
30
21
21
270
270
185
220
QT- FIT5/8 2x54-58
280
30
21
270
165
LE MK-EM T-ECG 13 Edition:.06.2013. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
03
QUICKTRONIC fit T5/T8
Lamp wiring
QT-FIT 5/8 1x…
QT-FIT 5/8 1x…
Max. permitted cable length in between ECG and lamp: 2.0 m (PIN 21, 22); 1.0 m (PIN 23, 24)
QT-FIT 5/8 2x…
Max. permitted cable length in between ECG and lamp: 2.0 m (PIN 21, 22); 1.5 m (PIN 23, 24); 1.0 m (PIN 25,
26)
QT-FIT 5/8 2x…
Logistic Data
Description
EAN 10
EAN 40
Packaging Unit
QT- FIT5/8 1x18-39
4008321873927
4008321873934
20
QT- FIT5/8 2x18-39
4008321873903
4008321873910
20
QT- FIT5/8 1x54-58
4008321873828
4008321873835
20
QT- FIT5/8 2x54-58
4008321873842
4008321873859
20
LE MK-EM T-ECG 13 Edition:.06.2013. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
04
QUICKTRONIC fit T5/T8
Lifetime
Measuring point
temperature tc:
Lifetime
with max. 10% failure rate
75 °C
30,000 h
70 °C
50,000 h
Expected lifetime
ECG ambient temperature (ta) ECG
Lamp
HO 24
HO 39
QT- FIT5/8 1x1839
L18
L30
L36
HO 24
HO 39
QT- FIT5/8 2x1839
L18
L30
L36
QT- FIT 5/8 1x5458
QT- FIT 5/8 2x5458
HO 54
L 58
HO 54
L 58
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
lifetime [h]
temperature at tc-point [°C]
40°C
100,000
55
100,000
55
100,000
55
100,000
55
100,000
55
100,000
55
100,000
60
100,000
50
100,000
55
100,000
55
100,000
50
100,000
50
60,000
65
70,000
65
50°C
70,000
65
60,000
65
70,000
65
70,000
65
60,000
65
100,000
60
70,000
70
100,000
60
100,000
65
100,000
65
80,000
60
80,000
60
30,000
75
40,000
70
60°C
40,000
70
30,000
75
40,000
70
40,000
70
40,000
75
70,000
70
X
X
80,000
70
60,000
75
60,000
75
50,000
70
50,000
70
X
X
X
X
Expected lifetime is the calculation of the ECG lifetime according to
IEC_60929_Edition_4_2011. As background for this estimation, are the MTTF values
according to SN 29500 and the component- parameters used
LE MK-EM T-ECG 13 Edition:.06.2013. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
05
QUICKTRONIC fit T5/T8
Lamp/ECG System Combination
ECG
QT- FIT5/8 1x18-39
QT- FIT5/8 2x18-39
QT- FIT5/8 1x54-58
QT- FIT5/8 2x54-58
Lamp
L 16 ES
L 18
HO 20 ES
HO 24
L 30
L 32 ES
L 36
HO ES 34 W
HO 39
L 16 ES
L 18
HO 20 ES
HO 24
L 30
L 32 ES
L 36
HO ES 34 W
HO 39
HO 50 ES
L 51 ES
HO 54
L 58
HO 50 ES
L 51 ES
HO 54
L 58
HF lamp
wattage [W]
14.2
16
20
23
24
29
32
32
38
14.2
16
20
23
24
29
32
32
38
50
44.5
54
50
50
44.5
54
50
System
wattage [W]
In preparation
21
25
28
33
In preparation
37
38
42
In preparation
39
47
53
63
In preparation
70
75
80
54
In preparation
54
58
108
In preparation
108
110
Line current [A]
In preparation
0.09
0.12
0.13
0.15
In preparation
0.16
0.17
0.19
In preparation
0.18
0.21
0.24
0.27
In preparation
0.31
0.33
0.36
0.24
In preparation
0.24
0.24
0.46
In preparation
0.48
0.48
Luminous flux at
25°C [lm]
1350
1350
1650
1750
3000
2500
3200
3100
3100
1350
1350
1650
1750
3000
2500
3200
3100
3100
4450
4200
4450
5000
4450
4200
4450
5000
Luminous flux at
35°C [lm]
2000
2000
3650
3500
2000
2000
3650
3500
5000
5000
5000
5000
-
Power factor
[λ]
In preparation
0.98
0.98
0.98
0.98
In preparation
0.98
0.98
0.98
In preparation
0.98
0.98
0.98
0.98
In preparation
0.98
0.98
0.98
0.98
In preparation
0.98
0.98
0.98
In preparation
0.98
0.98
For more information on ECG refer to http://www.osram.com
For more information on System Guarantee refer to http://www.osram.com
LE MK-EM T-ECG 13 Edition:.06.2013. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
06