QUICKTRONIC fit T5/T8 osram.com QUICKTRONIC FIT QT-FIT5/8 ECG for T5/16mm and T8/26mm linear fluorescent lamps QT- FIT5/8 ® i.e. LUMILUX T5 LE MK-EM T-ECG 13 Edition:.06.2013. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 01 QUICKTRONIC fit T5/T8 Product Features: 50,000 hours lifetime1 Lamp start with optimized filament preheating within 2 s Suitable for lighting with very high switching cycles Reliable lamp ignition between -15°C...+50°C Suitable for luminaries of protection class I CELMA Energy Efficiency Index A2 Automatic safety shut-down in case of a defect or at the end of the lamp’s life (EoL T.2) Automatic restart after lamp replacement Suitable for DC installations Technical Data Max. cross section push-in contact [mm2]: s2: 0.5 - 1.5 Starting time: < 2 sec. Line voltage: 220 - 240 V Voltage range (AC): 198 - 264 V Voltage range (DC): 185 – 276 V; for lamp ignition min. 198 V; max. 1 hour 185 - 198V Line frequency: Operating frequency: Electrical strength: Ambient temperature ta: Measuring point temperature tc: U-OUT: 1 2 50 - 60 Hz 40 - 50 kHz 280 V permanent; 300 V 2 hours -15°C to +50 °C Max. +75 °C 430 V Average lifetime s = solid wire LE MK-EM T-ECG 13 Edition:.06.2013. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 02 QUICKTRONIC fit T5/T8 Inrush current and max. number of ECG per circuit breaker ECG QT- FIT5/8 QT- FIT5/8 QT- FIT5/8 QT- FIT5/8 Inrush Current 1x18-39 2x18-39 1x54-58 2x54-58 Max. number of ECG per circuit breaker Ip [A] TH [µs] 24 40 24 53 230 200 230 200 B: 10A 17 12 17 8 B: 16A C: 16 A 28 19 28 13 47 32 47 22 Standards and approval marks Safety: acc. to EN 61347-2-3 / IEC 61347-2-3 Radio interference: acc. EN 55015: 2006 + A1: 2007 + A2: 2009 Harmonic content: acc. to EN 61000-3-2 / IEC 61000-3-2 Immunity: acc. to EN 61547 / IEC 61547 Approval marks: Dimensions & weight Description Description Length [mm] Width [mm] Height [mm] Distance Mounting Holes [mm] Weight [g] QT- FIT5/8 1x18-39 280 30 21 270 160 QT- FIT5/8 2x18-39 QT- FIT5/8 1x54-58 280 280 30 30 21 21 270 270 185 220 QT- FIT5/8 2x54-58 280 30 21 270 165 LE MK-EM T-ECG 13 Edition:.06.2013. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 03 QUICKTRONIC fit T5/T8 Lamp wiring QT-FIT 5/8 1x… QT-FIT 5/8 1x… Max. permitted cable length in between ECG and lamp: 2.0 m (PIN 21, 22); 1.0 m (PIN 23, 24) QT-FIT 5/8 2x… Max. permitted cable length in between ECG and lamp: 2.0 m (PIN 21, 22); 1.5 m (PIN 23, 24); 1.0 m (PIN 25, 26) QT-FIT 5/8 2x… Logistic Data Description EAN 10 EAN 40 Packaging Unit QT- FIT5/8 1x18-39 4008321873927 4008321873934 20 QT- FIT5/8 2x18-39 4008321873903 4008321873910 20 QT- FIT5/8 1x54-58 4008321873828 4008321873835 20 QT- FIT5/8 2x54-58 4008321873842 4008321873859 20 LE MK-EM T-ECG 13 Edition:.06.2013. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 04 QUICKTRONIC fit T5/T8 Lifetime Measuring point temperature tc: Lifetime with max. 10% failure rate 75 °C 30,000 h 70 °C 50,000 h Expected lifetime ECG ambient temperature (ta) ECG Lamp HO 24 HO 39 QT- FIT5/8 1x1839 L18 L30 L36 HO 24 HO 39 QT- FIT5/8 2x1839 L18 L30 L36 QT- FIT 5/8 1x5458 QT- FIT 5/8 2x5458 HO 54 L 58 HO 54 L 58 lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] lifetime [h] temperature at tc-point [°C] 40°C 100,000 55 100,000 55 100,000 55 100,000 55 100,000 55 100,000 55 100,000 60 100,000 50 100,000 55 100,000 55 100,000 50 100,000 50 60,000 65 70,000 65 50°C 70,000 65 60,000 65 70,000 65 70,000 65 60,000 65 100,000 60 70,000 70 100,000 60 100,000 65 100,000 65 80,000 60 80,000 60 30,000 75 40,000 70 60°C 40,000 70 30,000 75 40,000 70 40,000 70 40,000 75 70,000 70 X X 80,000 70 60,000 75 60,000 75 50,000 70 50,000 70 X X X X Expected lifetime is the calculation of the ECG lifetime according to IEC_60929_Edition_4_2011. As background for this estimation, are the MTTF values according to SN 29500 and the component- parameters used LE MK-EM T-ECG 13 Edition:.06.2013. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 05 QUICKTRONIC fit T5/T8 Lamp/ECG System Combination ECG QT- FIT5/8 1x18-39 QT- FIT5/8 2x18-39 QT- FIT5/8 1x54-58 QT- FIT5/8 2x54-58 Lamp L 16 ES L 18 HO 20 ES HO 24 L 30 L 32 ES L 36 HO ES 34 W HO 39 L 16 ES L 18 HO 20 ES HO 24 L 30 L 32 ES L 36 HO ES 34 W HO 39 HO 50 ES L 51 ES HO 54 L 58 HO 50 ES L 51 ES HO 54 L 58 HF lamp wattage [W] 14.2 16 20 23 24 29 32 32 38 14.2 16 20 23 24 29 32 32 38 50 44.5 54 50 50 44.5 54 50 System wattage [W] In preparation 21 25 28 33 In preparation 37 38 42 In preparation 39 47 53 63 In preparation 70 75 80 54 In preparation 54 58 108 In preparation 108 110 Line current [A] In preparation 0.09 0.12 0.13 0.15 In preparation 0.16 0.17 0.19 In preparation 0.18 0.21 0.24 0.27 In preparation 0.31 0.33 0.36 0.24 In preparation 0.24 0.24 0.46 In preparation 0.48 0.48 Luminous flux at 25°C [lm] 1350 1350 1650 1750 3000 2500 3200 3100 3100 1350 1350 1650 1750 3000 2500 3200 3100 3100 4450 4200 4450 5000 4450 4200 4450 5000 Luminous flux at 35°C [lm] 2000 2000 3650 3500 2000 2000 3650 3500 5000 5000 5000 5000 - Power factor [λ] In preparation 0.98 0.98 0.98 0.98 In preparation 0.98 0.98 0.98 In preparation 0.98 0.98 0.98 0.98 In preparation 0.98 0.98 0.98 0.98 In preparation 0.98 0.98 0.98 In preparation 0.98 0.98 For more information on ECG refer to http://www.osram.com For more information on System Guarantee refer to http://www.osram.com LE MK-EM T-ECG 13 Edition:.06.2013. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided. TECHNICAL INFORMATION 06