pdf

QUICKTRONIC INTELLIGENT QTi GII
osram.com
QUICKTRONIC INTELLIGENT
QTi GII
ECG for T5/16mm, T8/26mm and
various other lamp types
QTi GII
®
i.e. LUMILUX T5 HO ES
GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
01
QUICKTRONIC INTELLIGENT QTi GII
Product Features:










Up to 100.000 hours lifetime1
Lamp start with optimized filament preheating within 1 sec.
Suitable for lighting with very high switching cycles
Reliable lamp ignition between -20°C...+50°C
Cut-off Technology
Suitable for luminaries of protection classes I and II2
CELMA Energy Efficiency Index A2 BAT (Best Available Technology)
Automatic safety shut-down in case of a defect or at the end of the lamp’s life (EoL T.2)
Automatic restart after lamp replacement
Suitable for emergency installations (DC operation)
Technical Data
Max. cable diameter
for IDC-contakt [mm2]:
„s“3: 0.5; „s-f“4: 0.75
Max. cable diameter for
push-in contact [mm2]:
„s“3: 0.5…1.0
Starting time:
t: < 1 sec.
(<0.3 sec. in case of line interruptions/switchover of <0.5 sec.)
Line voltage:
220 - 240 V
Voltage range (AC):
198 - 264 V
Voltage range (DC):
176 - 276 V
Line frequency:
0, 50 - 60 Hz
Operating frequency:
Electrical strength:
Ambient temperature ta:
Measuring point temperature tc:
U-OUT:
1
2
3
4
42 - 85 kHz
300 V  permanent, 320 V  48 hours, 350 V  2 hours
-20 °C to +50 °C
Max. +75 °C
330 V
at T = 65°C @ Tc. 50.000 h with max. 10% failure rate at tc = 75°C max
No need to connect (functional) earth in suitable luminaires of protection class II
“s” = solid wire
“s-f” = stranded – flexible wire
GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
02
QUICKTRONIC INTELLIGENT QTi GII
Inrush current and max. number of ECG per circuit breaker
ECG
Inrush Current
Ip [A]
24
53
24
53
53
39
60
QTi 1x14/24/21/39 GII
QTi 2x14/24/21/39 GII
QTi 1x28/54/35/49 GII
QTi 2x28/54/35/49 GII
QTi 1x35/49/80 GII
QTi 2x35/49/80 GII
QTi 2x35/49/80
Max. number of ECG per circuit breaker
TH [µs]
230
190
230
190
190
230
230
B: 10A
17
8
17
8
8
5
5
B: 16A
28
13
28
13
13
9
9
C: 16 A
47
22
47
22
22
15
15
Standards and approval marks
Safety:
acc. to EN 61347-2-3 / IEC 61347-2-3
Radio interference
acc. EN 55015: 2006 + A1: 2007 + A2: 2009
Harmonic content:
acc. to EN 61000-3-2 / IEC 61000-3-2
Immunity:
acc. to EN 61547 / IEC 61547
Approval marks:
Dimensions & weight
Description
Description
Length
[mm]
Width
[mm]
Height
[mm]
Distance
Weight [g]
mounting
holes [mm]
QTi 1x14/24/21/39 GII
360
30
21
350
220
QTi 2x14/24/21/39 GII
QTi 1x28/54/35/49 GII
360
30
21
350
250
360
30
21
350
240
QTi 2x28/54/35/49 GII
360
30
21
350
270
QTi 1x35/49/80 GII
360
30
21
350
240
QTi 2x35/49/80 GII
425
30
21
415
400
QTi 2x35/49/80
425
30
21
415
400
GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
03
QUICKTRONIC INTELLIGENT QTi GII
Lamp wiring
QTi 1x… GII
Max. permitted cable length in between ECG and lamp: 2.0 m (PIN 21, 22); 1.0 m (PIN 23, 24)
QTi 2x… GII
Max. permitted cable length in between ECG and lamp: 2.0 m (PIN 21, 22, 23); 1.0 m (PIN 24, 25, 26, 27)
Logistic Data
Description
EAN 10
EAN 40
Packaging Unit
QTi 1x14/24/21/39 GII
4008321383334
4008321383341
20
QTi 2x14/24/21/39 GII
4008321383396
4008321383402
20
QTi 1x28/54/35/49 GII
4008321383358
4008321383365
20
QTi 2x28/54/35/49 GII
4008321383419
4008321383426
20
QTi 1x35/49/80 GII
4008321383372
4008321383389
20
QTi 2x35/49/80 GII
4008321658951
4008321658968
20
QTi 2x35/49/80
4008321174291
4008321174307
20
Lifetime
Measuring point
temperature tc:
Lifetime
with max. 10% failure rate
75 °C
50,000 h
65 °C
100,000 h
GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
04
QUICKTRONIC INTELLIGENT QTi GII
Lamp/ECG System Combination
ECG
QTi 1x14/24/21/39 GII
QTi 2x14/24/21/39 GII
Lamp
HE 14
HE 21
HO 24
HO 39
HE 13 ES5
HE 19 ES5
HE 25 ES5
HE 32 ES5
HO 20 ES5
HO 34 ES5
T8 L 185
T8 L 365
T8 L 385
DL/DF 365
DL 405
FC 225
FC 405
2x HE 14
2x HE 21
2x HO 24
2x HO 39
2x HE 13 ES5
2x HE 19 ES5
2x HE 25 ES5
2x HE 32 ES5
2x HO 20 ES5
2x HO 34 ES5
2x T8 L 185
2x T8 L 365
2x T8 L 385
HF lamp
wattage [W]
14
21
23
38
13
19
40
68
20
34
16
32
32
30
40
22
40
2x 14
2x 20.5
2x 23
2x 38
2x 13
2x 19
2x 25.5
2x 31.5
2x 20
2x 34
32
64
64
System
wattage [W]
16
24
26
41
15
22
44
73
23
37
19
35
36
34
44
25
43
31
45
50
81
29
42
56
68
44
73
37
70
70
Line current [A]
0.08
0.11
0.12
0.18
0.07
0.10
0.19
0.31
0.10
0.16
0.09
0.16
0.16
0.15
0.19
0.12
0.19
0.15
0.20
0.23
0.36
0.125
0.18
0.26
0.31
0.19
0.31
0.17
0.31
0.31
Luminous flux at
25°C [lm]
1200
1900
1750
3100
1150
1800
2x1650
2x3250
1650
3250
1300
3200
3300
2750
3500
1800
3200
2x 1200
2x 1900
2x 1750
2x 3100
2x1150
2x1800
2x2500
2x3150
2x1650
2x3250
2x 1300
2x 3200
2x 3300
Luminous flux at
35°C [lm]
1350
2100
2000
3500
1350
2100
2950
3700
2000
3500
2x 1350
2x 2100
2x 2000
2x 3500
2x1350
2x2100
2x2950
2x3700
2x2000
2x3500
-
Power factor
[λ]
0.92c
0.94c
0.96
0.98
0.91c
0.94c
0.96
0.98
0.96
0.98
0.93c
0.96
0.96
0.98
0:98
0.94c
0:96
0.95
0.96
0.96
0.98
0.95
0.96
0.96
0.96
0.96
0.98
0.96
0.98
0.98
GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
05
QUICKTRONIC INTELLIGENT QTi GII
ECG
QTi 2x14/24/21/39 GII
QTi 1x28/54/35/49 GII
QTi 2x28/54/35/49 GII
QTi 1x35/49/80 GII
Lamp
2x DL/DF 365
2x DL 405
2x FC 225
5
2x FC 40
HE 28
HE 35
HO 49
HO 54
DL 28
HE 25 ES5
HE 32 ES5
HO 45 ES5
HO 50 ES5
DL 16 HE5
DL 22 HE5
DL 26 HE5
T8 L 58 W5
2x HE 28
2x HE 35
2x HO 49
2x HO 54
2x DL 28
2x HE 25 ES5
2x HE 32 ES5
2x HO 45 ES5
2x HO 50 ES5
2x DL 16 HE5
2x DL 22 HE5
2x DL 26 HE5
2x T8 L 58 W5
HE 35
HO 49
HO 80
DL 80
HE 32 ES5
HO 45 ES5
HO 73 ES5
DL 26 HE5
HF lamp
wattage [W]
60
80
44
80
28
35
49
54
28
25
32
45
50
16
23
27
50
2x 28
2x 35
2x 49
2x 54
2x 28
51
63
90
100
32
45
54
98
35
49
80
80
32
45
73
27
System
wattage [W]
68
86
49
88
32
39
53
58
31
29
36
48
54
18
25
30
55
61
76
105
115
60
56
68
98
108
35
49
59
108
39
53
85
85
36
48
79
30
Line current [A]
0.29
0.37
0.21
0.36
0.15
0.18
0.24
0.26
0.14
0.13
0.16
0.21
0.23
0.80
0.11
0.13
0.24
0.28
0.35
0.46
0.51
0.27
0.26
0.31
0.42
0.46
0.15
0.21
0.26
0.47
0.18
0.24
0.38
0.38
0.16
0.21
0.34
0.13
Luminous flux at
25°C [lm]
2x 2800
2x 3500
2x 1800
2x 3200
2600
3320
4310
4450
2700
2500
3150
4310
4450
1500
2200
2600
5000
2x 2600
2x 3320
2x 4310
2x 4450
2x 2700
2x 2500
2x 3150
2x 4310
2x 4450
2x 1500
2x 2200
2x 2600
2x 5000
3320
4310
6150
6000
3150
4310
6150
2600
Luminous flux at
35°C [lm]
2900
3650
4600
5000
2800
2950
3700
4900
5000
1600
2350
2700
2x 2900
2x 3650
2x 4600
2x 5000
2x 2800
2x 2950
2x 3700
2x 4900
2x 5050
2x 1600
2x 2350
2x 2700
3650
4900
7000
3700
4900
7000
2700
Power factor
[λ]
0.98
0.98
0.99
0.99
0.95
0.96
0.97
0.97
0.95
0.95
0.96
0.97
0.98
0.96
0.97
0.97
0.99
0.96
0.96
0.98
0.98
0.96
0.96
0.96
0.99
0.99
0.99
0.99
0.99
0.99
0.96
0.97
0.98
0.98
0.96
0.97
0.98
0.97
GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
06
QUICKTRONIC INTELLIGENT QTi GII
ECG
QTi 1x35/49/80 GII
QTi 2x35/49/80 GII
QTi 2x35/49/80
Lamp
DL 28 HE5
DL 555
FC 555
2x HE 35
2x HO 49
2x HO 80
2x HE 32 ES
2x HO 45 ES
2x HO 73 ES
2x DL 80
2x HE 145
2x HE 215
2x HE 285
2x HE 13 ES5
2x HE 19 ES5
2x HE 25 ES5
2x DL 26 HE5
2x DL 28 HE5
2x DL 555
2x FC 555
2x HE 35
2x HO 49
2x HO 80
HF lamp
wattage [W]
28
55
55
2x 36
2x 49
2x 80
2x 33
2x 45
2x 73
2x 80
2x 15
2x 22
2x 29
2x 13
2x 19
2x 26
2x 27
2x 28
2x 55
2x 55
2x 35
2x 49
2x 80
System
wattage [W]
31
59
59
77
105
167
70
95
155
167
34
49
63
30
43
57
59
61
119
119
75
104
165
Line current [A]
0.14
0.26
0.26
0.36
0.45
0.70
0.33
0.43
0.66
0.70
0.18
0.23
0.30
0.16
0.21
0.27
0.27
0.27
0.53
0.53
0.34
0.46
0.74
Luminous flux at
25°C [lm]
2700
4800
4200
2x 3400
2x 4310
2x 6150
2x 3150
2x 4310
2x 6150
2x 6000
2x 1250
2x 2000
2x 2650
2x 1150
2x 1800
2x 2500
2x 2650
2x 2700
2x 4800
2x 4200
2x 3320
2x 4310
2x 6150
Luminous flux at
35°C [lm]
2800
2x 3750
2x 4900
2x 7000
2x 3700
2x 4900
2x 7000
2x 1400
2x 2200
2x 2950
2x 1350
2x 2100
2x 2950
2x 2750
2x 2800
2x 3650
2x 4900
-
Power factor
[λ]
0.95
0.99
0.99
0.98
0.99
0.99
0.97
0.99
0.99
0.99
0.95
0.96
0.97
0.95
0.96
0.97
0.96
0.97
0.98
0.98
0.95
0.97
0.99
For more information on ECG refer to http://www.osram.com/ecg
For more information on System Guarantee refer to http://www.osram.com/guarantee
5
Additional Lamp-ballast combination without ENEC
GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
07