S2A THRU S2M

SURFACE MOUNT GLASS PASSIVATED RECTIFIER
S2A THRU S2M
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
2.0 Ampere
FEATURES
•
•
•
•
•
•
DO-214AA(SMB)
Plastic package has underwrites laboratory flammability
Classification 94V-0
For surface mounted applications
Low profile package
Built-in strain relief, ideal for automated placement
Glass Passivated chip junction
High temperature soldering guaranteed
250℃/10 second at terminals
MECHANICAL DATA
•
•
•
•
Case: JEDED DO-214AA molded plastic over glass passivated chip
Terminals: Solder plated, Solderable per MIL-STD-750, method 2026
Polarity: Color band denotes cathode end
Weight: 0.002ounce, 0.064 gram
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
•
Ratings at 25℃ ambient temperature unless otherwise specified
MAXIMUM RATINGS & THERMAL CHARACTERISTICS
Maximum Repetitive Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified
Current at TL =100℃
Peak Forward Surge Current
8.3ms single half sine wave superimposed on
rated load (JEDEC method) T L=100℃
Typical Thermal Resistance (NOTE 1)
Operating and Storage Temperature Range
SYMBOLS
VRRM
VRMS
VDC
S2A
50
35
50
S2B
100
70
100
S2D
200
140
200
S2G
400
280
400
S2J
600
420
600
S2K
800
560
800
S2M
1000
700
1000
UNIT
Volts
Volts
Volts
IF(AV)
2.0
Amps
IFSM
50
Amps
RθJA
RθJL
TJ,TSTG
53
16
-55 to +150
℃/W
℃
ELECTRICAL CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 1.5A
Maximum DC Reverse Current
at rated DC Blocking Voltage
TA = 25℃
TA = 125℃
Typical Reverse Recovery Time at
IF=0.5A, IR=1.0A, IRR=0.25A,
SYMBOLS
VF
S2A
S2B
IR
S2D
S2G
1.15
5.0
125
S2J
S2K
S2M
UNIT
Volts
µA
2.0
µs
CJ
30
Notes:
1. Thermal resistance from Junction to ambient and from junction to lead mounted on
P.C.B.with 0.3×0.3″(8.0 × 8.0mm) copper pad areas.
pF
Trr
Typical junction capacitance at 4.0V, 1MHz
Web Site: www.hkmic.com
SURFACE MOUNT GLASS PASSIVATED RECTIFIER
S2A THRU S2M
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
2.0 Ampere
60Hz RESISTIVE OR
INDUCTIVE LOAD
1.5
1.0
0.5
60 Hz RESISTIVE OR
INDUCTIVE LOAD
0.27X0.27″(7.0X7.0mm)
COPPER PAD AREAS
0
50
60
70
80
90
100 110 120 130 140 150
F1G.2-MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
50
TL =90℃
8.3ms Single Half Sine-Wave
(JEDEC Method)
40
AMPERES
AVERAGE FORWARD CURRENT
AMPERES
F1G.1-FORWARD CURRENT
DERATING CURVE
PEAK FORWARD SURGE CURRENT,
RATINGS AND CHARACTERISTIC CURVES S2A THRU S2M
30
20
10
0
1
LEAD TEMPERATURE,(℃)
INSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
F1G.3-TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
INSTANTANEOUS FORWARD CURRENT,
AMPERES
10
TJ =25℃
Pulse Width=300us
1% Duty Cycle
1.0
0.1
100
F1G.4-TYPICAL REVERSE
CHARACTERISTICS
10
TJ =125℃
1.0
TJ =100℃
0.1
T J =25℃
0.01
0.01
0.4
0.6
0.8
1.0
1.2
1.4
1.6
INSTANTANEOUS FORWARD VOLTAGE, VOLTS
F1G.5-TYPICAL JUNCTION CAPACITANCE
JUNCTION CAPACITANCE,(pF)
10
NUMBER OF CYCLES AT 60 Hz
100
T J =25℃
f=1MHz
Vsig=50mVp-p
10
1
0.01
0.1
1.0
10
100
REVRESE VOLTAGE,(V)
Web Site: www.hkmic.com
0
20
40
60
80
PERCENT OF RATED PEAK
REVERSE VOLTAGE,(%)
100