EN

Accessories
Modular bus covers
CANopen®
Shaft / end shaft encoders
View inside bus cover
Bus cover
Termination
1
CAN_L
CAN_H
UB
GND
2
CAN_L
CAN_H
UB
GND
3
DUO-LED
Baud rate
Terminal
connector
User address
Cable: 1, 2 = ø8-10 mm (-40-85 °C) / ø5-9 mm (-25-85 °C)
Cable: 3 = ø4.5-6 mm (-40-85 °C) / ø3-6 mm (-25-85 °C)
Connector M12
Features - CANopen®
Terminal assignment
Bus protocol
CANopen®
Pin 1
Device profile
CANopen® - CiA DSP 406, V 3.0
(Device Class 2, CAN 2.0B)
Pin 2
UB
Voltage supply 10...30 VDC
Pin 3
GND
Ground connection relating to UB
Pin 4
CAN_H
CAN bus signal (dominant High)
Pin 5
CAN_L
CAN bus signal (dominant Low)
Operating mode Event-triggered
Time-triggered
Remotely-requested
Sync (cyclic)
Sync (acyclic)
1
Termination
ON
ON = final user
OFF = user X
1
User address (identifier)
5
Z 163.5PA2 CANopen/Connector M12
10147370
CANopen/Cable gland in stainless steel V2A without DUO-LED
10167265
CANopen/Connector M12
10167266
CANopen/Connector M12 in stainless
steel V2A without DUO-LED
11048898
CANopen/ATEX cable gland
Dip switch position
1 23
OFF
OFF OFF
OFF
OFF ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF OFF
ON
OFF ON
ON
ON
OFF
ON
ON
ON
8
7
If the user address is 00 the baud rate and Node ID are
programmable via CAN bus.
4
www.baumer.com/motion
Subject to modification in technic and design.
1 2 3
Z 163.5P32 CANopen/Cable gland
Baud rate
10 kbit/s
20 kbit/s
50 kbit/s
125 kbit/s
250 kbit/s
500 kbit/s
800 kbit/s
1 MBit/s
27.11.2015
Part number
CANopen/Cable gland
Defined by rotary switch.
Example: User address 23
Baud rate
ON
10140832
6
6
7
8
9
9
0 1
0 1
4
50 kbit/s, Node ID 1
Connector M12 (male / female)
A-coded
1
5
Default
2
4
3
Heartbeat or Nodeguarding
2
5
2
Node ID
monitoring
3
3
The encoder supports the following error
warnings:
-Position and parameter error
-Lithium battery voltage control
(Multiturn)
3
2
Diagnosis
5
4
Rotating direction Parameter for defining the rotating direction in which there have to be ascending
or descending position values.
Parameter defining the steps per turn as
well as the total resolution.
Ground connection relating to UB
Terminals of the same significance are internally connected
and identical in their functions. Max. load on the internal
terminal connections UB-UB and GND-GND is 1 A each.
Parameter for setting the encoder to a
requested position value assigned to a
defined shaft position of the system. The
offset of encoder zero point and mechanical zero point is stored in the encoder.
Scaling
GND
4
Preset
Cable gland
Accessories
Modular bus covers
DeviceNet
Shaft / end shaft encoders
View inside bus cover
Bus cover
Termination
1
CAN_L
CAN_H
DRAIN
Baud rate
DUO-LED
DRAIN
2
CAN_L
CAN_H
UB
Terminal
connector
GND
User address
Cable: 1, 2 = ø8-10 mm (-40-85 °C) / ø5-9 mm (-25-85 °C)
Connector M12
Features - DeviceNet
Terminal assignment
Bus protocol
DeviceNet
Pin 1
Device profile
Device Profile for Encoders V 1.0
Operating modes I/O-Polling
Cyclic
Change of State
Preset
Parameter for setting the encoder to a
requested position value assigned to a
defined shaft position of the system. The
offset of encoder zero point and mechanical zero point is stored in the encoder.
Parameter defining the steps per turn as
well as the total resolution.
Diagnosis
The encoder supports the following error
warnings:
-Position and parameter error
-Lithium battery voltage control
(Multiturn)
Default
DRAIN
Shield
Pin 2
UB
Voltage supply 10...30 VDC
Pin 3
GND
Ground connection relating to UB
Pin 4
CAN_H
CAN bus signal (dominant High)
Pin 5
CAN_L
CAN bus signal (dominant Low)
Terminals of the same significance are internally connected
and identical in their functions. Max. load on the internal
terminal connections UB-UB and GND-GND is 1 A each.
5
5
4
4
3
3
Rotating direction Parameter for defining the rotating direction in which there have to be ascending
or descending position values.
Scaling
Cable gland
1
2
1
2
Connector M12 (male / female), A-coded
Termination
ON
ON = final user
OFF = user X
1
125 kbit/s, Mac ID 63
User address (identifier)
ON
1 2 3
8
7
Baud rate
125 kBit/s
250 kBit/s
500 kBit/s
125 kBit/s*
Dip switch position
1 23
X
OFF OFF
X
OFF ON
X
ON
OFF
X
ON
ON
X = w/o function
* = This switch position is not defined, therefore internally
set to default 125 kBit/s.
7
www.baumer.com/motion
Subject to modification in technic and design.
DeviceNet/Connector M12 in stainless
steel V2A without DUO-LED
Baud rate
27.11.2015
DeviceNet/Connector M12
10167273
6
7
6
5
10167269
4
DeviceNet/Cable gland in stainless steel V2A without DUO-LED
5
10147371
Defined by rotary switch.
Example: User address 23
4
DeviceNet/Cable gland
3
Z 163.8PA2 DeviceNet/Connector M12
10140833
3
Z 163.8P22 DeviceNet/Cable gland
2
Part number
2
8
9
9
0 1
0 1
Accessories
Modular bus covers
Profibus-DPV0
Shaft / end shaft encoders
View inside bus cover
Bus cover
Termination
1
A
B
DUO-LED
UB
GND
2
A
B
Terminal
connector
UB
User
address
Cable: 1, 2 = ø8-10 mm (-40-85 °C) / ø5-9 mm (-25-85 °C)
Cable: 3 = ø4.5-6 mm (-40-85 °C) / ø3-6 mm (-25-85 °C)
Connector M12
Features - Profibus-DPV0
Terminal assignment
Bus protocol
Profibus-DPV0
Device profile
Device Class 1 and 2
Connector M12 (male), A-coded
Pin 1
UB Voltage supply 10...30 VDC
Cyclic data
exchange
Communication in line with DPV0
Pin 3 4
3
Input data
Position value. In addition optionally
speed signal parametering (output of
current rotation speed).
1
Output data
Preset
Preset
Parameter for setting the encoder to a
requested position value assigned to
a defined shaft position of the system.
Storage non-volatile.
Diagnosis
The encoder supports the following error
warnings:
-Position and parameter error
-Lithium battery voltage control
(Multiturn)
Default
Ground connection relating to UB
2
Pin 4
5
3
4
B
3
2
1
Positive data line
5
4
2
1
Terminals of the same significance are internally connected
and identical in their functions. Max. load on the internal
terminal connections UB-UB and GND-GND is 1 A each.
Termination
ON
User address 00
Termination OFF
both ON = final user
both OFF = user X
1 2
User address (identifier)
Z 163.3P32 Profibus-DPV0/Cable gland
0 1
0 1
10
8
7
6
8
7
Profibus-DPV0/ATEX cable gland
6
11048897
5
Profibus-DPV0/Connector M12 stainless
steel V2A without DUO-LED
4
Profibus-DPV0/Connector M12
10167256
5
10167254
Defined by rotary switch.
Example: User address 23
4
Profibus-DPV0/Cable gland stainless
steel V2A without DUO-LED
3
10147369
2
Profibus-DPV0/Cable gland
3
10140831
2
Z 163.3PA2 Profibus-DPV0/Connector M12
9
9
Part number
www.baumer.com/motion
Subject to modification in technic and design.
Parameter defining the steps per turn as
well as the total resolution.
GND Connector M12 (male / female), B-coded
Pin 2
A
Negative data line
Rotating direction Parameter for defining the rotating direction in which there have to be ascending
or descending position values.
Scaling
Cable gland
27.11.2015
GND
3
Accessories
Modular bus covers
Profibus-DPV2
Shaft / end shaft encoders
View inside bus cover
Bus cover
Termination
1
A
B
DUO-LED
UB
GND
2
A
B
Terminal
connector
UB
User
address
Cable: 1, 2 = ø8-10 mm (-40-85 °C) / ø5-9 mm (-25-85 °C)
Cable: 3 = ø4.5-6 mm (-40-85 °C) / ø3-6 mm (-25-85 °C)
Connector M12
Features - Profibus-DPV2
Terminal assignment
Bus protocol
Profibus-DPV2
Device profile
Device Class 3 and 4
Connector M12 (male), A-coded
Pin 1
UB Voltage supply 10...30 VDC
Cyclic data
exchange Communication by synchronous clock
(IsoM) in line with DPV2
DXB (cross traffic): publisher function
Pin 3 4
3
Acyclic data
exchange
I&M (Identification and Maintenance)
Functions
1
Input data
Position value. In addition optionally
speed signal parametering (output of
current rotation speed).
Connector M12 (male / female), B-coded
Pin 2
A
Negative data line
Output data
Preset
Preset
Parameter for setting the encoder to a
requested position value assigned to
a defined shaft position of the system.
Storage non-volatile.
Diagnosis
The encoder supports the following error
warnings:
-Position and parameter error
-Lithium battery voltage control
(Multiturn)
2
B
3
2
1
Positive data line
5
4
2
1
Terminals of the same significance are internally connected
and identical in their functions. Max. load on the internal
terminal connections UB-UB and GND-GND is 1 A each.
Termination
ON
both ON = final user
both OFF = user X
1 2
User address 00
Termination OFF
User address (identifier)
8
7
6
8
7
3
5
4
6
2
3
Z 163.3V32 Profibus-DPV2/Cable gland
2
Part number
9
9
0 1
0 1
Defined by rotary switch.
Example: User address 23
4
Default
Ground connection relating to UB
5
Z 163.3VA2 Profibus-DPV2/Connector M12
10167260
Profibus-DPV2/Cable gland
10167262
Profibus-DPV2/Cable gland stainless
steel V2A without DUO-LED
10167281
Profibus-DPV2/Connector M12
10167263
Profibus-DPV2/Connector M12 stainless
steel V2A without DUO-LED
11
www.baumer.com/motion
Subject to modification in technic and design.
Parameter defining the steps per turn as
well as the total resolution.
GND Pin 4
5
3
4
Rotating direction Parameter for defining the rotating direction in which there have to be ascending
or descending position values.
Scaling
Cable gland
27.11.2015
GND
3
Accessories
Modular bus covers
EtherCAT
Shaft / end shaft encoders
View inside bus cover
Bus cover
DUO-LED
OUT
L/A
IN
LED´s
Link/Activity
Features - EtherCAT
Terminal assignment
Bus protocol
EtherCAT
Device profile
CoE (CANopen over EtherCAT)
DSP406
Voltage supply
Terminal Assigned
Significance
Pin 1
UB
Voltage supply
Features
-100 MBaud Ethernet
-Automatic address designation
-Distributed clock for precise synchro nization. Optional device configuration
as „Reference Clock“
-Default 10 byte PDO, configurable
4 byte PDO / 2 byte PDO for shorter
cycle times
Pin 2
N.C.
Not assigned
Pin 3
GND
Ground
Pin 4
N.C.
Not assigned
Cycle times
Depending on sensor type, enabled
scaling functionality and length of PDO.
Min. cycle time: 62,5 µs
Synchronization
1
2
1 x Connector M12 (male), A-coded
EtherCAT (data line)
Terminal Assigned Significance
0x00 Free Run, not synchronized
0x03 Distributed clocks DC,
synchronized with SYNCO/SYNC1
Event
Pin 1
TxD+
Transmission data+
Pin 2
RxD+
Receiving data+
Pin 3
TxD-
Transmission data-
Pin 4
RxD-
Receiving data-
3
Part number
4
2
1
2 x Connector M12 (female), D-coded
Z 163.EPA6 Bus cover EtherCAT
Accessories
12
Z 185.E05
Connector M12, on both sides, CuZn nickelplated/TPU, 5 m cable PUR (data line)
Z 185.P05
Connector M12, CuZn nickel-plated/TPU, 5 m cable PUR, 360º screen (voltage supply)
www.baumer.com/motion
Subject to modification in technic and design.
Position value
Warnings
System time
3
27.11.2015
Process data
4
Accessories
Modular bus covers
PoE - Power over EtherCAT
Shaft / end shaft encoders
View inside bus cover
Bus cover
DUO-LED
/$
LED
Link/Activity
Features - Power over EtherCAT
Terminal assignment
Bus protocol
EtherCAT
Terminal Assigned
Significance
Device profile
CoE (CANopen over EtherCAT)
DSP406
Pin 1
TxD+
Transmission data+
-100 MBaud Ethernet
-Automatic address designation
-Distributed clock for precise synchro- nization. Optional device configuration as „Reference Clock“
-Default 10 byte PDO, configurable
4 byte PDO / 2 byte PDO for shorter
cycle times
Pin 2
RxD+
Receiving data+
Pin 3
TxD-
Transmission data-
Pin 4
RxD-
Receiving data-
Position value
Warnings
System time
Cycle times
Depending on sensor type, enabled
scaling functionality and length of PDO.
Min. cycle time: 62,5 µs
Synchronization
0x00 Free Run, not synchronized
0x03 Distributed clocks DC,
synchronized with SYNCO/SYNC1
Event
Function PoE
Compliant to standard IEEE Std 802.3af
Excess
temperature
Protection against excess temperature
PoE mains unit Galvanically insulated
Hot-Connect
Connecting/disconnecting the device
during operation
4
2
1
2 x Connector M12 (female), D-coded
Power supply of PSE module (Power Sourcing Equipment)
is also by these lines.
Accessories
Z 185.E05
Ethernet cable, connector M12 on both sides
with 5 m cable
Subject to modification in technic and design.
Process data
3
Technical data - Power over EtherCAT
Capacity class
1 (max. 4 W)
Supply voltage
44…57 VDC
Current
consumption
≤50 mA (48 VDC)
Cable length
Max.100 m
Part number
Z 163.EEA2 Bus cover PoE - Power over EtherCAT
13
www.baumer.com/motion
27.11.2015
Features
Accessories
Modular bus covers
SSI
Shaft / end shaft encoders
View inside bus cover
Bus cover
DUO-LED
Terminal assignment
Features - SSI
Preset
Parameter for setting the encoder to a
requested position value assigned to a
defined shaft position of the system. The
offset of encoder zero point and mechanical zero point is stored in the encoder.
Rotating direction Parameter for defining the rotating direction in which there have to be ascending
or descending position values.
Scaling
Parameter defining the steps per turn as
well as the total resolution.
Diagnosis
The encoder supports the following error
warnings:
-Position and parameter error
-Lithium battery voltage control
(Multiturn)
TerminalAssigned
5-pin connector*
8-pin connector / colour
Pin 1
UB
Clock+ / white
Pin 2
RxD
Clock- / brown
Pin 3
GND-PRG
Data+ / green
Pin 4
GND B
Data- / yellow
Pin 5
TxD
Preset / grey
Pin 6
–
UP/DOWN / pink
Pin 7
–
GND B / blue
Pin 8
–
* programming interface
5
UB / red
5
4
3
1
2
2
1
5-pin connector, A-coding
8-pin connector, A-co
ding
4
3
6
7
8
Parameters
Programmable by ProGeber software
SSI clock frequency
62.5 kHz...1.0 MHz
Monoflop time
15...50 µs (Default: 20 µs)
Clock interval
Min. 180 µs
Voltage supply
10...30 VDC
Output
RS485 driver
Accessories
Status LED
Green: operational
Yellow (red/green on): warning of the
lithium battery charge condition
Red (2.5 s on): position error
Z 139.008
Programming cable for encoders with SSI bus cover, CD with software and manualr
Z 174.003
Connector M12, 8-pin with 2 m cable
Z 174.005
Connector M12, 8-pin with 5 m cable
Recommendation: use pairs of twisted wires with
extension cables.
Part number
Z 163.2PA2 Bus cover SSI
14
www.baumer.com/motion
Subject to modification in technic and design.
SSI (Synchronous Serial Interface)
27.11.2015
Bus protocol
Accessories
Modular bus covers
PROFINET
Shaft / end shaft encoders
View inside bus cover
Bus cover
DUO-LED
operating conditions
P2
L/A
P1
LED´s
activity
Features - PROFINET
Terminal assignment
Bus protocol
PROFINET
Device profile
Encoder Profile PNO 3.162 Version 4.1
Voltage supply
Terminal Assigned
Significance
Features
-100 MBaud Fast Ethernet
-Automatic address designation
-Realtime (RT) Class 1, IRT Class 2,
IRT Class 3
Pin 1
UB
Voltage supply
Pin 2
N.C.
Not assigned
Pin 3
GND
Ground
Pin 4
N.C.
Not assigned
-Position value 32 bit input data
with/without rotation speed 16/32 bit
-Telegram 81-83 of Profidrive profils
4
3
1
2
Part number
1 x Connector M12 (male), A-coded
Z 163.3EA2 Bus cover PROFINET
PROFINET (data line)
Terminal Assigned Significance
Pin 1
TxD+
Transmission data+
Pin 2
RxD+
Receiving data+
Pin 3
TxD-
Transmission data-
Pin 4
RxD-
Receiving data-
3
4
Accessories
15
Z 185.E05
Ethernet cable, connector M12 on both sides
with 5 m cable (data line)
Z 185.P05
Connector M12 with 5 m cable, 360º screen
(current line)
www.baumer.com/motion
Subject to modification in technic and design.
2
1
2 x Connector M12 (female), D-coded
27.11.2015
Process data
Accessories
Modular bus covers
EtherNet/IP
Shaft / end shaft encoders
View inside bus cover
Bus cover
IP-address
(only shaft
encoder)
DUO-LED
3
/$
3
LED´s
Link/Activity
Features - EtherNet/IP
Terminal assignment
Bus protocol
EtherNet/IP
Device profile
Encoder Device, type 22hex,
according to CIP specification
Voltage supply
Terminal Assigned
Significance
Pin 1
UB
Voltage supply
Features
-100 MBaud Fast Ethernet
-IP address programmable
- Automatic IP address designation
(DHCP)
- Rotation direction, resolution, total
resolution and preset are programmable
according to CIP specification
Pin 2
N.C.
Not assigned
Pin 3
GND
Ground
Pin 4
N.C.
Not assigned
Position value, Warning Flag, Alarmflag
Assembly Instances 1 and 2 according
to CIP spezification
3
1
2
1 x Connector M12 (male), A-coded
EtherNet/IP (data line)
Terminal Assigned Significance
Part number
Z 163.8EA2 Bus cover EtherNet/IP
Pin 1
TxD+
Transmission data+
Pin 2
RxD+
Receiving data+
Pin 3
TxD-
Transmission data-
Pin 4
RxD-
Receiving data-
3
4
IP address
Defined by HEX rotary switch
Example: IP address B5hex
Configuration via DHCP: 00hex
Accessories
17
Z 185.E05
Ethernet cable, connector M12 on both sides with 5 m cable (data line)
Z 185.P05
Connector M12 with 5 m cable, 360º screen (current line)
www.baumer.com/motion
Subject to modification in technic and design.
2
1
2 x Connector M12 (female), D-coded
27.11.2015
Process data
4
Accessories
Modular bus covers
POWERLINK
Shaft / end shaft encoders
View inside bus cover
Bus cover
Node ID
DUO-LED
3
/$
3
LED´s
Link/Activity
Features - POWERLINK
Terminal assignment
Bus protocol
Ethernet Powerlink 2.0
Device profile
DSP406
Voltage supply
Terminal Assigned
Significance
Address
Free configurable via software or rotary
switch
Standard node 1
Standard IP 192.168.100.1
Pin 1
UB
Voltage supply
Pin 2
N.C.
Not assigned
Pin 3
GND
Ground
Pin 4
N.C.
Not assigned
4
3
1
2
1 x Connector M12 (male), A-coded
POWERLINK (data line)
Terminal Assigned Significance
Position value
Pin 1
TxD+
Transmission data+
Part number
Pin 2
RxD+
Receiving data+
Z 163.5EA2 Bus cover POWERLINK
Pin 3
TxD-
Transmission data-
Pin 4
RxD-
Receiving data-
Accessories
3
19
8
6
7
9
9
Ethernet cable, connector M12 on both sides
with 5 m cable (data line)
8
160565
7
Connector M12 straight with 10 m cable,
(current line)
6
135247
0 1
0 1
5
Connector M12 straight with 5 m cable,
(current line)
4
133853
Node ID
5
Connector M12 straight with 2 m cable,
(current line)
4
133852
2
1
2 x Connector M12 (female), D-coded
3
Connector M12 with 5 m cable, 360º screen
(current line)
2
Z 185.P05
4
3
Ethernet cable, connector M12 on both sides
with 5 m cable (data line)
2
Z 185.E05
Defined by rotary switch.
Example: User address 23.
If the rotary switch 00 the
Node ID are programmable via bus.
www.baumer.com/motion
Subject to modification in technic and design.
Process data
-100 MBaud Ethernet
-Response times <2 µs
-Cycle times <200 µs
- Jitter from Start of Cycle (SoC) to
position detection <200 ns
- Daisy Chain is possible
- Rotation direction, resolution, total
resolution and preset are programmable
27.11.2015
Features
Accessories
Modular bus covers
SAEJ1939
Shaft / end shaft encoders
SAEJ1939
View inside bus cover
Bus cover
Termination
&$1B/
&$1B+
8%
&$1B/
&$1B+
8%
3
DUO-LED
*1'
Terminal
connector
*1'
Cable: 1, 2 = ø8...10 mm / 3 = ø4.5...6 mm
Without
function
Connector M12
Cable gland
Features - SAE J1939
Terminal assignment
Bus protocol
SAE J1939
Pin 1
Device profile
Industry Group 5, Industrial, Process
control
Pin 2
UB
Voltage supply 10...30 VDC
Pin 3
–
–
Pin 4
CAN_H
CAN bus signal (dominant High)
Pin 5
CAN_L
CAN bus signal (dominant Low)
Parameter for setting the encoder to a
requested position value assigned to a
defined shaft position of the system. The
offset of encoder zero point and mechanical zero point is stored in the encoder.
Rotating direction Parameter for defining the rotating direction in which there have to be ascending
or descending position values.
Scaling
Parameter defining the steps per turn as
well as the total resolution.
Diagnosis
The encoder supports the following error
warnings:
-Position and parameter error
-Lithium battery voltage control
(Multiturn)
Node ID
monitoring
Heartbeat or Nodeguarding
Cycle time
Repetition rate for data: position,
speed, diagnostic
Ground connection relating to UB
Terminals of the same significance are internally connected
and identical in their functions. Max. load on the internal
terminal connections UB-UB and GND-GND is 1 A each.
4
1
5
3
3
2
2
5
4
1
Connector M12 (male / female)
A-coded
Termination
1
Time-triggered, On Request
ON
Operating mode
Preset
GND
ON = final user
OFF = user X
J1939 Definitions (Default settings)
Baud rate
250 kbit/s
Address
172 (0xAC)
Arbitrary adress capable
1
Industry Group
5
Vehicle System
0
System Instance, ECU instance 0
Part number
Z 163.5B32 SAEJ1939/Cable gland
Z 163.5BA2 SAEJ1939/Connector M12
20
Function
142 (0x8E)
Function instance
0
Manufacturer
343 (0x157)
Identity Number
Device-individual
PGN 65450: encoder position,
speed, diagnostic
Properitary B, Broadcast
communication
Transmission repetition rate
50 ms
Data length
8 bytes
PDU format PF
255 (0xFF)
PDU specific PS
0xAA
Default priority
6
Parameter group number PGN
65450 (0xFFAA)
www.baumer.com/motion
Subject to modification in technic and design.
2
Without
function
27.11.2015
1