EN

Inclination sensors
Measuring range ±15°, ±30°, ±60°, 360°
CANopen® / Profibus-DP
GNAMG
Features
–– Inclination sensor / CANopen® / Profibus
–– Measuring range two-dimensional: ±15°, ±30°, ±60°
–– Measuring range one-dimensional: 360°
–– Resolution: 0.001° to 1°
–– Accuracy: ±0.1° to 0.2°
–– Programmable parameters
–– Protection max. IP 67
Optional
–– Stainless steel
Technical data - mechanical design
Voltage supply
Dimensions mounting plate 99 x 60 x 5 mm
10...30 VDC
Reverse polarity protection Yes
Consumption w/o load
≤100 mA (24 VDC)
Initializing time typ.
250 ms after power on
Interfaces
CANopen®, Profibus-DPV0
Device adress
Rotary switch in bus cover
Measuring range
±15°/±30°/±60°
(two-dimensional)
360° (one-dimensional)
Resolution
0.001..1 ° (measuring range
15°, 30°, 60°)
0.1..1 ° (measuring range 360°)
Accuracy (+25 °C)
±0.1 ° (measuring range 15°)
±0.2 ° (measuring range 30°,
60°, 360°)
Settling time max.
0.5 s
Measuring cycle
10 Hz
Code
Binary
Interference immunity
DIN EN 61000-6-2
Emitted interference
DIN EN 61000-6-4
Programmable
parameters
Resolution
Preset and offset
Diagnostic function
Parameter error
Status indicator
DUO-LED integrated in bus
cover
Approval
UL approval / E63076
1
Protection DIN EN 60529
IP 66 (connector M12),
IP 67 (cable gland)
Materials
Bus cover: zinc die-cast
Base plate: aluminium
Operating temperature
-25...+85 °C
-40...+85 °C (optional: only
cable gland)
Relative humidity
95 % non-condensing
Resistance
DIN EN 60068-2-6
Vibration 10 g, 16-2000 Hz
DIN EN 60068-2-27
Shock 200 g, 6 ms
Weight approx.
250 g
Connection
Cable gland
Connector M12, 4-pin
Connector M12, 5-pin
www.baumer.com/motion
14/4/2016
Technical data - electrical ratings
Subject to modification in technic and design. Errors and omissions excepted.
GNAMG with mounting plate 99 x 60 mm
Inclination sensors
Measuring range ±15°, ±30°, ±60°, 360°
CANopen® / Profibus-DP
GNAMG
Part number
Accessories
GNAMG.
Connectors and cables
0
3P32
3PA2
21
22
23
15
Z 180.007
Female connector M12, 5-pin, A-coded,
10 m cable
Z 181.005
Cable connector M12, 5-pin, A-coded, 5 m
cable, CANopen®, connection continuative
bus
Programming accessories
Z 150.022
CD with describing files & manuals
Terminal assignment
Measuring range
Dual axes ±15°
Dual axes ±30°
Dual axes ±60°
Single axis 360° (no end stop)
CANopen® – M12 connector, assignment 1
Connector Assignment Description
Housing
0 Bus cover with mounting plate
99 x 60 mm
CD with file descriptions is not included in the delivery. You
may order them on CD as accessory.
Pin 1
GND
Ground connection relating to UB
Pin 2
UB
Voltage supply 10...30 VDC
Pin 3
GND
n.c.
Pin 4
CAN_H
CAN bus signal (dominant High)
Pin 5
CAN_L
CAN bus signal (dominant Low)
CANopen® – M12 connector, assignment 2
Connector Assignment Description
Pin 1
Drain
Pin 2
UB
Voltage supply 10...30 VDC
Pin 3
GND
Ground connection relating to UB
Pin 4
CAN_H
CAN bus signal (dominant High)
Pin 5
5
4
CAN_L
5
4
3 3
CAN bus signal (dominant Low)
1
2
M12 connector (male / female)
A-coded
1
2
Profibus – M12 connector
Pin 1
UB
Voltage supply 10...30 VDC
Pin 3
4
3
GND
Ground connection relating to UB
1
M12 connector (male)
A-coded
2
Pin 2
A
Pin 4
5
4
B
3
1
2 2
3
Negative data line
Positive data line
5
4
M12 connector (male / female)
B-coded
1
Terminals of the same significance are internally connected
and identical in their functions. Max. load on the internal
terminal connections UB-UB and GND-GND is 1 A each.
2
www.baumer.com/motion
Subject to modification in technic and design. Errors and omissions excepted.
5PB2
Interface
CANopen® / cable gland
CANopen® / connector M12,
assignment 1
CANopen® / connector M12,
assignment 2
Profibus-DPV0 / cable gland
Profibus-DPV0 / connector
M12
Female connector M12, 5-pin, A-coded,
5 m cable
14/4/2016
5P32
5PA2
Z 180.005
Inclination sensors
Measuring range ±15°, ±30°, ±60°, 360°
CANopen® / Profibus-DP
GNAMG
Installation position
Measuring range 15º, 30º, 60º
The two-dimensional inclination sensor with a configured range of 15°, 30°
and 60° must be mounted with the base plate in horizontal position, i.e.
parallel to the horizontal line. The inclination sensor may also be installed
upside down, i.e. turned by 180°.
The sensor can be inclined both towards the X and Y axis at the same time.
For each axis a separate measured value is provided. Default on delivery
the inclination sensor will apply the selected sensing range to both axis, for
example ±15° with the zero passage being precisely in the horizontal line.
Default 0º
Measured inclination -30º
Default 0º
Measured inclination 30º
Measuring range 360º
The inclination sensor with a configured range of 360º must be mounted in a
way that the X-axis as in the following sketch is directed in a parallel way
towards gravity. The deflection may not be more than ±3º.
+
X
Default 0º
The 360° inclination sensor default position is 0° as shown in the following
illustration but may be configured at will by help of the preset function.
The measuring direction may also be inverted. Default on delivery the
inclination sensor’s sensing direction is clockwise from 0...360°, in case of
active inversion counter-clockwise.
Measured inclination 45º
Measured inclination 135º
3
Measured inclination 180º
www.baumer.com/motion
Subject to modification in technic and design. Errors and omissions excepted.
Z
Please note also that the inclination sensor must evenly touch the contact
surface and during inclination/rotation must not be subject to any inclination
in X- or Y-direction since this would have a negative impact on the measuring accuracy.
14/4/2016
Y
Inclination sensors
Measuring range ±15°, ±30°, ±60°, 360°
CANopen® / Profibus-DP
GNAMG
Dimensions
GNAMG - cable gland
45
37.5
5.3(5x)
63
60
1
75
99
5
36.3
60
y+
x+
y–
23
x–
24.5
Profibus connector M12
CANopen® - M12
4
www.baumer.com/motion
14/4/2016
Subject to modification in technic and design. Errors and omissions excepted.
63
60
63
60
Mounting version
Inclination sensors
Measuring range ±15°, ±30°, ±60°, 360°
CANopen® / Profibus-DP
GNAMG
View inside bus cover
Bus cover - CANopen®
Termination
CAN_L
CAN_H
UB
CAN_L
CAN_H
UB
Terminal
connector
GND
User address
Cable: 1, 2 = ø8-10 mm (-40-85 °C) / ø5-9 mm (-25-85 °C)
Cable: 3 = ø4.5-6 mm (-40-85 °C) / ø3-6 mm (-25-85 °C)
Connector M12
Features - CANopen®
Termination
Bus protocol
CANopen®
ON
Device profile
CANopen® - CiA DSP 406, V 3.0
(Device Class 2, CAN 2.0B)
Operating mode
Event-triggered, Time-triggered
Remotely-requested
Sync (cyclic), Sync (acyclic)
Preset/Offset
Parameter for setting the inclination
sensor to a requested position value
assigned to a defined shaft position of
the system. Storage non-volatile.
User address (identifier)
50 kbit/s, Node ID 1
9
8
7
6
9
8
7
6
5
Default
4
Heartbeat or Nodeguarding
3
Node ID
monitoring
1
2
Resolution parametering
0.001...1° (15°/30°/60°)
0.1...1° (360°)
3
Resolution
0
1
5
0
2
Scaling „enabled“ will consider the parameterized preset/offset.
ON = final user
OFF = user X
1
Rotating direction Parameter for defining the inclination
direction in which there have to be ascending or descending position values.
Scaling
Cable gland
Defined by rotary switch.
Example: User address 23
Baud rate
ON
1 2 3
Baud rate
10 kbit/s
20 kbit/s
50 kbit/s
125 kbit/s
250 kbit/s
500 kbit/s
800 kbit/s
1 MBit/s
Dip switch position
1
2
3
OFF
OFF OFF
OFF
OFF ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF OFF
ON
OFF ON
ON
ON
OFF
ON
ON
ON
If the user address is 00 the baud rate and Node ID are
programmable via CAN bus.
5
www.baumer.com/motion
Subject to modification in technic and design. Errors and omissions excepted.
3
DUO-LED
14/4/2016
2
Baud rate
GND
4
1
Inclination sensors
Measuring range ±15°, ±30°, ±60°, 360°
CANopen® / Profibus-DP
GNAMG
View inside bus cover
Bus cover - Profibus-DPV0
Termination
1
$
%
DUO-LED
8%
2
*1'
$
%
Terminal
connector
8%
3
*1'
User
address
Cable:1,2=ø8-10mm(-40-85°C)/ø5-9mm(-25-85°C)
Cable:3=ø4.5-6mm(-40-85°C)/ø3-6mm(-25-85°C)
ConnectorM12 Cablegland
Features - Profibus-DPV0
Termination
Busprotocol
Profibus-DPV0
Deviceprofile
DeviceClass2
ON
Cyclicdata
exchange
CommunicationinlinewithDPV0
Inputdata
Positionvalue.
Outputdata
PresetandOffset(only15°/30°/60°).
Preset/Offset
Parameterforsettingtheinclination
sensortoarequestedpositionvalue
assignedtoadefinedshaftpositionof
thesystem.Storagenon-volatile.
bothON=finaluser
bothOFF=userX
1 2
User address (identifier)
8
7
9
6
9
8
7
1
Definedbyrotaryswitch. Example:Useraddress23
3
3
4
6
0
2
5
1
4
0
2
5
Scaling„enabled“willconsidertheparameterizedpreset/offset.
Resolution
Resolutionparametering
0.001...1°(15°/30°/60°)
0.1...1°(360°)
Default
Useraddress00
TerminationOFF
6
www.baumer.com/motion
14/4/2016
Scaling
Subject to modification in technic and design. Errors and omissions excepted.
Rotatingdirection Parameterfordefiningtheinclination