Automotive BL-DC Fans for Commercial Vehicles Edition 2015-10 Automotive BL-DC Fans for Commercial Vehicles Our automotive products BL-DC axial fans and BL-DC dual Benefits and characteristics at a glance centrifugal fans with housing are ground breakers in the field of commercial vehicle air conditioning. - over 40.000 operating hours - variable speed control They not only meet the increased demands for comfort, e.g. in - high efficiency - low sound emission thanks to aerodynamically optimized impellers buses but also work wear-free for over 40,000 operating hours as they are brushless. No additional maintenance, no additional servicing. - increased reliability due to the electronics’ high integration density - can be retrofitted into existing systems - compliance with the most stringent EMC requirements This corresponds to the usual reliability expected from ebm-papst. - configurable control curve - optimized voltage independence Data is subject to change without notice at ebm-papst discretion. - extended temperature range - long-life ball bearings EC dual centrifugal blower: for top performance in minimal 2015-10 installation space; easy to regulate and extremely quiet. 2 Information 2 EC axial fans "Basic" 48 GreenTech: The green company Ideas for changing technology in commercial vehicles 4 6 EC centrifugal fans - RadiCal, backward curved Technology: - Cables 52 74 78 EC axial fans "Premium & Power" - Technical parameters & scope ebm-papst agents EC axial fans "Basic" 26 63 64 EC centrifugal fans - RadiCal backward-curved EC axial fans "Premium & Power" - Accessories - Conn. diagrams 62 Technology 8 20 3 2015-10 EC dual centrifugal fan with housing "Premium" EC dual centrifugal fan with housing "Basic" Agents Our automotive products ..... EC dual centrifugal fans with housing "Basic" EC dual centrifugal fans with housing "Premium" Contents Sustainable thought processes and actions. As a matter of principle! Environmental compatibility and sustainability have always formed the basis for all our thought processes and actions. Which is why we have been dedicated for decades to the simple but firm principle of one of our company founders, Gerhard Sturm: “Every new product we develop must be economically and ecologically superior to its predecessor.” We use the name GreenTech to express our company philosophy. GreenTech means looking ahead. GreenTech means environmentally compatible production. We optimize the materials and processes we employ right from the GreenTech also stands for maximum energy efficiency in our design stage to ensure optimum environmental compatibility, the best production processes. Photovoltaics, the intelligent use of waste heat possible energy balance and – where feasible – maximum recyclability. and groundwater cooling and of course our own cooling and ventila- We are constantly improving materials, performance and the flow and tion technology all play a major role. noise characteristics of our products, while at the same time signifi- Energy consumption at our most modern plant is 91% lower than cantly reducing energy consumption. demanded by the applicable regulations for example. Close ties with universities and scientific institutes as well as a spon- In this way, our products make their contribution to environmental sored professorship in the field of power engineering and regenerative protection from the development stage right through to recycling of energies also allow us to benefit from the latest research results in the packaging. these areas – as well as providing us with a reservoir of highly qualified young talent for the future. GreenTech follows a firm philosophy. GreenTech is pro-active development. GreenTech pays off for our customers. GreenTech is eco-friendly production. 2015-10 GreenTech is acknowledged and certified. 4 Information EC dual centrifugal fans with housing "Premium" At the heart of GreenTech is innovative EC technology from environmental specialists and the public. ebm-papst, which enables our best motors and fans to attain Confirmation of this came in the form of an award as Germany’s most efficiency levels of up to 90%, achieves maximum energy savings, sustainable company in 2013 and the 2012 DEKRA Award ensures a far longer service life and makes our products completely in the category “Environment – The Challenge of Energy Transition” – maintenance-free. to name just a few examples. Figures that are not just good for the environment but also of 100% The ecological prowess of our products based on GreenTech princi- benefit to users! Because all ebm-papst products – even those ples is also verified by their compliance with even the most stringent for which GreenTech EC technology is not (yet) of relevance to the energy and environmental standards. particular application – offer an ideal combination of economic and In many cases they already more than satisfy limit values which will ecological advantages. EC dual centrifugal fans with housing "Basic" Our entire production chain can stand up to critical scrutiny by EC axial fans "Premium & Power" GreenTech is a good investment for our customers. 5 2015-10 Technology EC centrifugal fans - RadiCal backward-curved EC axial fans "Basic" only come into force in a few years time. Agents GreenTech is a recognized, award-winning concept. Ideas for changing technology in commercial vehicles Climate comfort in a commercial vehicle is anything but a question of Fans and blowers: convenience. Both the transportation of people in buses and coaches, as well truck journeys which are as stress and fatigue-free as possible, for commercial vehicle air conditioning and cooling of individual components. place high demands on vehicle technology; predominantly air conditioning, ventilation, and heating. For many years, major bus manufacturers have been installing air conditioners with brushless and wear-free centrifugal blowers and axial fans from ebm-papst. In the mean time, these products are also now widely used in the air conditioning and ventilation systems for the cabs in trucks, tractors and construction machinery, as well as in transport refrigeration systems. A number of air conditioning manufacturers rely on our experience and outstanding expertise in the core competencies of engine development, aerodynamics, and electronics. Counteracting high demands with new technologies: In modern commercial vehicles, EC technology has now become standard. Our new EC axial fans and EC dual centrifugal fans with second generation housing set a precedent in global commercial vehicle air conditioning. Our EC fans have even been able to demonstrate their clear However, ebm-papst has even more to offer: superiority in hot countries and tropical regions, where they have also As a competent consultant and practical implementer, we will certainly be able to find you a solution thanks to our in-depth knowledge from proven their worth. If you are unable to find a solution amongst our products, speak to us. many applications. But it is not just in the field of air conditioning products where customers are relying on ebm-papst products: EC fans are increasingly being used 2015-10 for cooling heat exchangers in the engine compartment of vehicles. 6 Information EC dual centrifugal fans with housing "Premium" In comparison: EC dual centrifugal fans with housing "Basic" In brush motors from various manufacturers, the commutator assumes the role of current distribution to the coils. The commutator consists of copper fins embedded in an insulating compound. Mechanical springs push the integrated carbon brushes to the commutator. These two rubbing mechanical components are the weak spot of conventional DC motors. After around 5,000 operating hours, the carbon brushes are run down and the commutator is worn. As a result, the entire blower must be replaced. In addition, it is only possible to regulate speed via external electronics. EC axial fans "Premium & Power" The brushless DC motors from ebm-papst are completely different. Here, an electronic controller directly integrated in the motor has the task of distributing current. No brushes means no wearing parts. This increases the service life of these motors to more than 40,000 hours. The user not only saves money in terms of replacement parts and repair costs, he also avoids unproductive downtimes and a possible loss of image. This also requires special efforts in terms of the selection of materials and testing of products. With the help of real-world extreme tests that we have defined in collaboration with leading OEMs (e.g., salt spray, vibration and temperature cycling tests), we are able to ensure the performance of the fans. EC axial fans "Basic" Apart from the considerably longer service life, our intelligent EC fans provide advanced control and regulation possibilities. The functionality of the fans can be checked via a diagnostic output at any time. Furthermore, these display excellent electromagnetic compatibility traits and operate EC centrifugal fans - RadiCal backward-curved extremely quietly. EC motors are energy efficient, because the integrated electronics with variable speed control only draw the energy actually required from the Technology on-board network. In the commercial vehicle sector, it is also crucial that fans withstand constantly changing environmental influences. Standard products would only provide unsatisfactory results here. For this reason, automotive products from ebm-papst are also reliably protected against Agents 7 2015-10 load dumping, reverse polarity, shock and vibration, as well as damage from moisture and dirt penetration across a wide temperature range. 2015-10 8 9 Technology EC centrifugal fans - RadiCal backward-curved EC axial fans "Basic" EC axial fans "Premium & Power" EC dual centrifugal fans with housing "Basic" EC dual centrifugal fans with housing "Premium" with brushless DC motor "Premium" Agents 2015-10 EC dual centrifugal fans with housing Information EC dual centrifugal fan with housing, for automotive applications, Ø 097 Sound power level Perm. ambient temp. Weight VDC m3/h rpm W A Pa dB(A) °C kg 26 16-32 1150 3500 325 12,5 0 81 Curves: Pa (1) 24-volt version -40..+85(2) 2,0 Connection diagram Min. back pressure VDC P. 69 / D) (2) above +70 °C with power derating in wg Subject to change A Input current M3G 084-BF Input power K3G 097-AF22 -02(1) Speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black (according to UL 94 HB) Blades: PA plastic (according to UL 94 HB) – Degree of protection: IP 24 KM – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings on both sides – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 – Approvals: EAC; E1 in preparation A n rpm Ped W I A LWA dB(A) 800 1 3500 325 12,50 81 A 2 4025 293 11,25 79 A 3 4495 272 10,45 78 A 4 4930 250 9,59 80 3 A 2.5 3 400 1.5 2 600 4 1 2 0.5 200 Pfs 0 qv 100 200 200 300 400 400 600 500 800 600 1cfm 1000 m³/h 2015-10 Air performance measured according to: ISO 5801, installation category A, in ebm-papst scroll housing without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 10 Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" EC axial fans "Premium & Power" 351 139.5 335 60 EC axial fans "Basic" 60 6 1 2 EC centrifugal fans - RadiCal backward-curved 170.5 136 Technology 4 Cable P. 62 Connection diagram P. 69 11 2015-10 45 64.5 90 101 Connector detail 1 = UN 2 = GND 3 = PWM/LIN 4 = INVLIN 5 = ABSENK 6 = diagnostic output Tyco Junior Power Timer 929505-2, 6-pole, coded. Mating connector Tyco 929504-2 (not included in scope of delivery). Cable (460 mm) with mating connector, part no. 02001-4-1021 (not included in scope of delivery). 5 3 Agents 217.5 2.5 10 Ø 4.5 11 104 18 10 100 75.5 EC dual centrifugal fan with housing, for automotive applications, Ø 097 Sound power level Perm. ambient temp. Weight VDC m3/h rpm W A Pa dB(A) °C kg 26 16-32 1150 3500 325 12,5 0 81 Curves: Pa (1) 24-volt version (2) above +70 °C with power derating -40..+85(2) 2,0 Connection diagram Min. back pressure VDC P. 69 / D) This Typee is also available with a sealed plug. in wg Subject to change A Input current M3G 084-BF Input power K3G 097-AF22 -07(1) Speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black (according to UL 94 HB) Blades: PA plastic (according to UL 94 HB) – Degree of protection: Motor: IP 24 KM, electronics: IP 66 / 69 K – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings on both sides – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 – Qualified in accordance with: DIN ISO 16750 – Approvals: EAC; E1 in preparation A n rpm Ped W I A LWA dB(A) 800 1 3500 325 12,50 81 A 2 4025 293 11,25 79 A 3 4495 272 10,45 78 A 4 4930 250 9,59 80 3 A 2.5 3 400 1.5 2 600 4 1 2 0.5 200 Pfs 0 qv 100 200 200 300 400 400 600 500 800 600 1cfm 1000 m³/h 2015-10 Air performance measured according to: ISO 5801, installation category A, in ebm-papst scroll housing without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 12 Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" EC axial fans "Premium & Power" 139.5 X 60 11 351 +20 415 Cable with plug (Plug is not sealed by the customer) 1 = +UB black 2 = GND brown 3 = PWM/LIN yellow 4 = INVLIN orange 5 = ABSENK blue 6 = diagnostic output white Tyco Junior Power Timer 929505-2, 6-pole, coded. Mating connector Tyco 929504-2 (not included in scope of delivery). 4 EC centrifugal fans - RadiCal backward-curved 170.5 79.5 2 5 Cable P. 62 3 Technology X 1 Connection diagram P. 69 13 2015-10 136 99 60 45 64.5 90 101 6 Agents 217.5 10 Ø 4.5 104 18 10 100 75.5 EC axial fans "Basic" 335 EC dual centrifugal fan with housing, for automotive applications, Ø 097 Air flow Speed Input power Input current Min. back pressure Sound power level Perm. ambient temp. Weight Nominal data Type Motor VDC m3/h rpm W A Pa dB(A) °C kg K3G 097-BF22 -02(1) M3G 084-BF 26 16-32 1040 3700 300 11,7 0 80 Curves: Pa (1) 24-volt version -40..+85(2) 2,0 P. 69 / D) (2) above +70 °C with power derating in wg Subject to change A Connection diagram Nominal voltage range VDC Curve Nominal voltage – Material: Housing: PP plastic, black (according to UL 94 HB) Blades: PA plastic (according to UL 94 HB) – Degree of protection: IP 24 KM – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings on both sides – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 – Approvals: EAC; E1 in preparation A n rpm Ped W I A LWA dB(A) 800 1 3700 300 11,70 80 A 2 4060 284 10,91 78 A 3 4580 263 10,10 78 A 4 4980 217 8,35 80 3 A 2.5 3 2 1 400 1.5 2 600 4 0.5 200 Pfs 0 qv 100 200 200 300 400 400 600 500 800 1 cfm m³/h 2015-10 Air performance measured according to: ISO 5801, installation category A, in ebm-papst scroll housing without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 14 Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" EC axial fans "Premium & Power" 335 325 144.5 196 65 8.5 3 EC centrifugal fans - RadiCal backward-curved 33.8 217.5 6 1 2 Technology 4 Cable P. 62 Connection diagram P. 69 15 2015-10 Connector detail 1 = UN 2 = GND 3 = PWM/LIN 4 = INVLIN 5 = ABSENK 6 = diagnostic output Tyco Junior Power Timer 929505-2, 6-pole, coded. Mating connector Tyco 929504-2 (not included in scope of delivery). Cable (460 mm) with mating connector, part no. 02001-4-1021 (not included in scope of delivery). 5 3 Agents 14.65 163.5 129 92 55 4.8 113.5 70 50 50 EC axial fans "Basic" 67 EC dual centrifugal fan with housing, for automotive applications, Ø 097 Sound power level Perm. ambient temp. Weight VDC m3/h rpm W A Pa dB(A) °C kg 26 16-32 1574 4680 740 28,0 0 88 -40..+60 2,0 Pa A 800 3 4 600 2 3 400 1 2 200 Pfs 0 qv 200 400 400 600 800 800 1200 1 cfm m³/h Air performance measured according to: ISO 5801, installation category A, in ebm-papst scroll housing without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 2015-10 P. 73 / Q) (1) 24-volt version Curves: 16 Connection diagram Min. back pressure VDC in wg Subject to change A Input current M3G 084-BF Input power K3G 097-AS82 -82(1) Speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – Material: Housing: PA plastic, black (according to UL 94 V0) Blades: PA plastic, black (according to UL 94 V0) – Degree of protection: Motor: IP 24 KM, electronics: IP 66 / 69 K – Insulation class: "B" – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings on both sides – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 – Approvals: EAC; E1 in preparation n rpm Ped W I A LWA dB(A) A 1 4680 740 28,0 88 A 2 5025 740 28,0 87 A 3 5380 659 25,3 85 A 4 5500 441 16,9 84 139.5 60 Connection diagram P. 73 Technology EC centrifugal fans - RadiCal backward-curved 99 10 10 11 17 Agents 217.5 2015-10 Ø 4.5 104 170.5 18 1000+20 351 335 100 75.5 79.5 136 60 101 90 64.5 45 EC axial fans "Basic" 75 ±10 8 Cable: + UB (black) GND (brown) PWM/LIN (yellow) Diagnostic output (white) EC axial fans "Premium & Power" EC dual centrifugal fans with housing "Basic" EC dual centrifugal fans with housing "Premium" Information EC dual centrifugal fan with housing, for automotive applications, Ø 097 K3G 097-AK36 -55 Weight VDC m3/h rpm W A Pa dB(A) °C kg 13 9-15 750 3630 195 15,0 300 70 13 9-15 1000 3740 385 29,5 0 76 2,6 P. 64 / A) P. 64 / A) Ped W I A LWA dB(A) A 1 --- --- --- --- A 2 3630 195 15,0 70 A 3 3875 177 13,5 71 A 4 4135 143 11,0 72 B 1 3740 385 29,5 76 B 2 4400 344 26,4 75 B 3 4775 309 23,8 76 B 4 4970 234 18,0 77 3,0 B 4 600 3 A 2,0 4 2 3 400 1,0 2 200 pfs 0 qV 100 200 200 300 400 400 600 500 800 600 1 cfm 1000 m 3/h Air performance measured according to: ISO 5801, installation category A, in ebm-papst scroll housing without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 2015-10 -40..+85 n rpm 800 18 (2) (2) wide open, not recommended for continuous operation at 85°C 4,0 Curves: Pa (1) 12-volt version 1180 -40..+85(2) 2,3 Connection diagram Perm. ambient temp. VDC in H2O Subject to change Sound power level M3G 074-BF B Min. back pressure A Input current M3G 074-BF (1) Input power K3G 097-AK32 -42(1) Speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black (according to UL 94 HB) Blades: PA plastic (according to UL 94 HB) – Degree of protection: IP 24 KM (without connectors) – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings on both sides – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 450+20 8 Wire-end ferrule Tin-plated Connection diagram P. 64 Technology 217.5 EC centrifugal fans - RadiCal backward-curved Cable detail: (K3G097-AK36-55) UN black PWM/LIN yellow GND brown EC axial fans "Basic" 170.5 136 60 64.5 45 90 101 10 18 10 104 19 Agents Ø 4.5 60 2015-10 Cable detail: (K3G097-AK32-42) UN black PWM/LIN yellow GND brown 351 335 100 75.5 139.5 11 2.5 450+20 6 EC axial fans "Premium & Power" EC dual centrifugal fans with housing "Basic" EC dual centrifugal fans with housing "Premium" Information 2015-10 20 21 Technology EC centrifugal fans - RadiCal backward-curved EC axial fans "Basic" EC axial fans "Premium & Power" EC dual centrifugal fans with housing "Basic" EC dual centrifugal fans with housing "Premium" with brushless DC motor "Basic" Agents 2015-10 EC dual centrifugal fans with housing Information EC dual centrifugal fan with housing, for automotive applications, Ø 097 Sound power level Perm. ambient temp. Weight VDC m3/h rpm W A Pa dB(A) °C kg 26 16-32 1290 3830 394 15,2 0 79 Curves: Pa (1) 24-volt version -40..+85(2) 2,0 Connection diagram Min. back pressure VDC P. 64 / F) (2) wide open, not recommended for continuous operation at 85°C in H2O Subject to change A Input current M3G 074-CF Input power K3G 097-AK34 -65(1) Speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black (according to UL 94 HB) Blades: PA plastic (according to UL 94 HB) – Degree of protection: IP 24 KM (without connectors) – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings on both sides – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 – Approvals: EAC, E1 A n rpm Ped W I A LWA dB(A) 800 4 2,0 500 2,4 100 % 600 3 80 % 1,6 400 7 2 60 % 0,8 200 1,2 8 300 12 6 11 0,4 0 pfs 100 qV 10 100 200 200 300 400 400 600 9 500 800 5 600 1000 700 1200 1 cfm m 3/h 2015-10 Air performance measured according to: ISO 5801, installation category A, in ebm-papst scroll housing without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 22 1 3830 394 15,2 79 A 2 4100 347 13,3 76 A 3 4380 285 10,9 75 A 4 4630 238 9,1 75 A 5 3150 215 8,3 75 A 6 3330 185 7,1 72 A 7 3510 149 5,7 70 A 8 3660 120 4,6 69 A 9 2240 79 3,1 66 A 10 2340 67 2,6 66 A 11 2430 53 2,0 61 A 12 2460 43 1,7 60 2,8 700 A Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" EC axial fans "Premium & Power" 139.5 EC axial fans "Basic" EC centrifugal fans - RadiCal backward-curved 170.5 136 217.5 3 Connector detail NC 1 = + UB NC NC = not used 2 = GND H H = UN (26 V) 3 = PWM/LIN, 100% speed 4 = 80% speed 5 = 60% speed 6 = NC (not used) Tyco Junior Power Timer 929505-2, 6-pole, coded. Mating connector Tyco 929504-2 (not included in scope of delivery). Cable (460 mm) with mating connector, part no. 02001-4-1021 (not included in scope of delivery). 1 2 Cable P. 62 5 3 4 Technology Speed setting Pin 5 4 60% H NC 80% NC H 100% NC NC 6 Connection diagram P. 64 23 2015-10 Ø 4.5 11 2.5 Agents 104 10 60 60 10 18 64.5 45 90 101 351 335 100 75.5 EC dual centrifugal fan with housing, for automotive applications, Ø 097 Sound power level Perm. ambient temp. Weight VDC m3/h rpm W A Pa dB(A) °C kg 26 16-32 1110 4040 344 13,3 0 77 Pa in H2O 700 600 2,8 800 A 3,2 900 100 % 2,0 4 500 3 80 % 1,6 400 7 60 % 0,8 200 1,2 8 300 2 12 6 11 0,4 100 10 pfs 0 qV 100 200 200 9 300 400 600 400 500 800 5 600 1000 1 cfm m 3/h 2015-10 Air performance measured according to: ISO 5801, installation category A, in ebm-papst scroll housing without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 24 P. 64 / F) (2) wide open, not recommended for continuous operation at 85°C 2,4 Curves: -40..+85(2) 2,0 Connection diagram Min. back pressure VDC (1) 24-volt version 3,6 Subject to change A Input current M3G 074-CF Input power K3G 097-BK34 -65(1) Speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black (according to UL 94 HB) Blades: PA plastic (according to UL 94 HB) – Degree of protection: IP 24 KM (without connectors) – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings on both sides – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 – Approvals: EAC, E1 n rpm Ped W I A LWA dB(A) A 1 4040 344 13,3 77 A 2 4210 325 12,5 76 A 3 4380 279 10,6 75 A 4 4630 242 9,2 75 A 5 3310 186 7,2 73 A 6 3390 171 6,6 71 A 7 3520 145 5,5 70 A 8 3650 121 4,6 69 A 9 2330 67 2,6 64 A 10 2360 62 2,4 62 A 11 2410 53 2,0 61 A 12 2480 42 1,6 60 Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" EC axial fans "Premium & Power" 335 8.5 144.5 EC axial fans "Basic" 65 92 55 EC centrifugal fans - RadiCal backward-curved 163.5 129 70 3 196 217.5 Speed setting Pin 5 4 60% H NC 80% NC H 100% NC NC 2 Cable P. 62 5 3 Technology 1 4 6 Connection diagram P. 64 25 2015-10 3 Connector detail NC 1 = + UB NC NC = not used 2 = GND H H = UN (26 V) 3 = PWM/LIN, 100% speed 4 = 80% speed 5 = 60% speed 6 = NC (not used) Tyco Junior Power Timer 929505-2, 6-pole, coded. Mating connector Tyco 929504-2 (not included in scope of delivery). Cable (460 mm) with mating connector, part no. 02001-4-1021 (not included in scope of delivery). Agents 113.5 4.8 50 325 67 50 2015-10 26 27 Technology EC centrifugal fans - RadiCal backward-curved EC axial fans "Basic" EC axial fans "Premium & Power" EC dual centrifugal fans with housing "Basic" EC dual centrifugal fans with housing "Premium" with brushless DC motor "Premium & Power" Agents 2015-10 EC axial fans Information EC axial fan for automotive applications, Ø 280 Sound power level Perm. ambient temp. Weight VDC m3/h rpm W A Pa dB(A) °C kg 26 16-32 2400 3100 200 7,5 --- 79 Curves: Pa (1) 24-volt version -40..+85(2) 2,4 Connection diagram Max. back pressure VDC P. 65 / H) (2) at maximum back pressure, not recommended for continuous operation at 85°C in H2O Subject to change A Input current M3G 074-CF Input power W3G 280-EQ20 -43(1) Speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black (according to UL 94 HB) Blades: PBT plastic, black (according to UL 94 HB) – Airflow direction: "V" (intake over the rotor) – Direction of rotation: Clockwise viewed toward rotor – Degree of protection: IP 24 KM – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 – Approvals: EAC, E1 A n rpm Ped W I A LWA dB(A) 1,5 400 1,0 300 4 200 0,5 3 100 2 pfs 0 qV 250 400 500 800 750 1200 1000 1600 1250 2000 1 cfm m 3/h 2015-10 Air performance measured according to: ISO 5801, installation category A, without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 28 A 1 3100 200 7,5 79 A 2 3085 197 7,6 79 A 3 3090 192 7,3 81 A 4 3105 213 8,2 83 Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" EC axial fans "Premium & Power" 172 EC axial fans "Basic" EC centrifugal fans - RadiCal backward-curved 1.5 21 18 .7˚ 325 +20 Ø303 8.5 X 57 94+2 ❮ "V" 1 2 6 3 Cable P. 62 Connection diagram P. 65 Technology Mating connector on customer circuit: Housing: Tyco 1-963212-1 Plug contacts: 2.5 mm Tyco 929938-1 (2x) 0.75 mm Tyco 929930-3 (4x) Seal: 828905-1 (2x) 828904-1 (4x) Detail X 1 = UN black 2 = GND brown 3 = PWM/LIN yellow 4 = INVLIN orange 5 = ABSENK blue 6 = diagnostic output white 6-pole coded Tyco Junior Power Timer; Cable (460 mm) with mating connector Part number 02002-4-1021 (not included in scope of delivery) 29 2015-10 5 4 Agents 4.3 Ø294 298 Ø125 Ø292 8 EC axial fan for automotive applications, Ø 300 Sound power level Perm. ambient temp. Weight VDC m3/h rpm W A Pa dB(A) °C kg 13 9-16 2610 3200 220 16,7 --- 83 Curves: Pa (1) 12-volt version A 1,2 1,0 0,6 0,8 150 100 0,4 200 50 0,2 250 pfs 0 qV 4 3 2 250 400 500 800 750 1200 1000 1600 1250 2000 1 1500 2400 cfm m 3/h 2015-10 Air performance measured according to: ISO 5801, installation category A, without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 30 P. 67 / K) (2) above +85 °C with power derating 350 300 -40..+105(2) 2,0 Connection diagram Max. back pressure VDC in H2O Subject to change A Input current M3G 084-BF Input power W3G 300-BV12 -41(1) Speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – Material: Housing: PA plastic, black (according to UL 94 HB) Blades: PA plastic, black (according to UL 94 HB) – Airflow direction: "V" (intake over the rotor) – Direction of rotation: Clockwise viewed toward rotor – Degree of protection: Motor: IP 24 KM, electronics: IP 66 / 69 K – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 – Qualified in accordance with: DIN ISO 16750 – Approvals: EAC, E1 n rpm Ped W I A LWA dB(A) A 1 3200 220 16,7 83 A 2 3140 235 18,1 82 A 3 2960 247 18,9 80 A 4 2840 248 19,0 82 Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" EC axial fans "Premium & Power" +2 76.5 0 54 +3 0 9. 5 16 EC axial fans "Basic" Ø318 0 +1 EC centrifugal fans - RadiCal backward-curved 0 +2 37 +2 24 ° X +20 300 0 ❮ "V" 1 2 3 Cable P. 62 Connection diagram P. 67 Technology 6 31 2015-10 5 4 Mating connector on customer circuit: Housing: Tyco 1-963212-1 Plug contacts: 2.5 mm Tyco 929938-1 (2x) 0.75 mm Tyco 929930-3 (4x) Seal: 828905-1 (2x) 828904-1 (4x) Detail X 1 = +UB black 2 = GND brown 3 = PWM/LIN* yellow *optional LIN-BUS 4 = NC (not used) 5 = ABSENK blue 6 = diagnostic output white 6-pole coded Tyco Junior Power Timer; Cable (460 mm) with mating connector Part number 02002-4-1021 (not included in scope of delivery) Agents 330 +2 4x9 0° 5 7. Ø34 Ø3 EC axial fan for automotive applications, Ø 300 Sound power level Perm. ambient temp. Weight VDC m3/h rpm W A Pa dB(A) °C kg 26 16-32 2570 3160 205 7,90 --- 82 Curves: Pa (1) 24-volt version A 1,2 1,0 0,8 150 0,6 200 100 0,4 250 4 3 0,2 2 0 pfs 50 qV 250 400 500 800 750 1200 1000 1600 1250 2000 1 1500 2400 cfm m 3/h 2015-10 Air performance measured according to: ISO 5801, installation category A, without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 32 P. 69 / D) (2) above +95 °C with power derating 350 300 -40..+110(2) 2,0 Connection diagram Max. back pressure VDC in H2O Subject to change A Input current M3G 084-BF Input power W3G 300-BS24 -01(1) Speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – Material: Housing: PA plastic, black (according to UL 94 HB) Blades: PA plastic, black (according to UL 94 HB) – Airflow direction: "V" (intake over the rotor) – Direction of rotation: Clockwise viewed toward rotor – Degree of protection: Motor: IP 24 KM, electronics: IP 66 / 69 K – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 – Qualified in accordance with: DIN ISO 16750 – Approvals: EAC, E1 n rpm Ped W I A LWA dB(A) A 1 3160 205 7,90 82 A 2 3150 216 7,30 82 A 3 3085 240 9,20 81 A 4 2965 244 9,40 80 Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" EC axial fans "Premium & Power" +2 76.5 0 54 +3 0 9. 5 13 EC axial fans "Basic" Ø318 0 +1 24 EC centrifugal fans - RadiCal backward-curved 0 0+2 37 +2 0 ° X +20 300 0 2 6 3 Cable P. 62 Connection diagram P. 69 Technology 5 33 2015-10 4 Mating connector on customer circuit: Housing: Tyco 1-963212-1 Plug contacts: 2.5 mm Tyco 929938-1 (2x) 0.75 mm Tyco 929930-3 (4x) Seal: 828905-1 (2x) 1 828904-1 (4x) ❮ "V" Detail X 1 = +UB black 2 = GND brown 3 = PWM/LIN* yellow *optional LIN-BUS 4 = INVLIN orange 5 = ABSENK blue 6 = diagnostic output white 6-pole coded Tyco Junior Power Timer; Cable (460 mm) with mating connector Part number 02002-4-1021 (not included in scope of delivery) Agents 330 +20 4x9 0° 5 7. Ø34 Ø3 EC axial fan for automotive applications, Ø 300 Sound power level Perm. ambient temp. Weight VDC m3/h rpm W A Pa dB(A) °C kg 26 16-32 2570 3160 205 7,90 --- 82 Curves: Pa (1) 24-volt version A 1,2 1,0 0,8 150 0,6 200 100 0,4 250 4 3 0,2 2 0 pfs 50 qV 250 400 500 800 750 1200 1000 1600 1250 2000 1 1500 2400 cfm m 3/h 2015-10 Air performance measured according to: ISO 5801, installation category A, without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 34 P. 69 / D) (2) above +95 °C with power derating 350 300 -40..+110(2) 2,0 Connection diagram Max. back pressure VDC in H2O Subject to change A Input current M3G 084-BF Input power W3G 300-BV24 -01(1) Speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – Material: Housing: PA plastic, black (according to UL 94 HB) Blades: PA plastic, black (according to UL 94 HB) – Airflow direction: "V" (intake over the rotor) – Direction of rotation: Clockwise viewed toward rotor – Degree of protection: Motor: IP 24 KM, electronics: IP 66 / 69 K – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 – Qualified in accordance with: DIN ISO 16750 – Approvals: EAC, E1 n rpm Ped W I A LWA dB(A) A 1 3160 205 7,90 82 A 2 3150 216 7,30 82 A 3 3085 240 9,20 81 A 4 2965 244 9,40 80 Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" EC axial fans "Premium & Power" +2 76.5 0 54 +3 0 9. 5 16 EC axial fans "Basic" Ø318 0 +1 EC centrifugal fans - RadiCal backward-curved 0 +2 37 +2 24 ° X +20 300 0 ❮ "V" 1 2 3 Cable P. 62 Connection diagram P. 69 Technology 6 35 2015-10 5 4 Mating connector on customer circuit: Housing: Tyco 1-963212-1 Plug contacts: 2.5 mm Tyco 929938-1 (2x) 0.75 mm Tyco 929930-3 (4x) Seal: 828905-1 (2x) 828904-1 (4x) Detail X 1 = +UB black 2 = GND brown 3 = PWM/LIN* yellow *optional LIN-BUS 4 = INVLIN orange 5 = ABSENK blue 6 = diagnostic output white 6-pole coded Tyco Junior Power Timer; Cable (460 mm) with mating connector Part number 02002-4-1021 (not included in scope of delivery) Agents 330 +2 4x9 0° 5 7. Ø34 Ø3 EC axial fan for automotive applications, Ø 300 Sound power level Perm. ambient temp. Weight VDC m3/h rpm W A Pa dB(A) °C kg 26 16-32 3225 3940 380 14,6 --- 87 600 500 A 1,6 4 400 1,2 200 0,8 3 300 0,4 2 0 pfs 100 qV 250 500 500 750 1000 1000 1500 1250 2000 1 1500 2500 3000 cfm m 3/h 2015-10 Air performance measured according to: ISO 5801, installation category A, without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 36 P. 69 / D) (2) above +85 °C with power derating 2,0 Curves: Pa (1) 24-volt version -40..+110(2) 2,0 Connection diagram Max. back pressure VDC 2,4 in H2O Subject to change A Input current M3G 084-BF Input power W3G 300-BV25 -21(1) Speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – Material: Housing: PA plastic, black (according to UL 94 HB) Blades: PA plastic, black (according to UL 94 HB) – Airflow direction: "V" (intake over the rotor) – Direction of rotation: Clockwise viewed toward rotor – Degree of protection: Motor: IP 24 KM, electronics: IP 66 / 69 K – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 – Qualified in accordance with: DIN ISO 16750 – Approvals: EAC, E1 n rpm Ped W I A LWA dB(A) A 1 3940 380 14,6 87 A 2 3815 408 15,7 87 A 3 3715 462 17,7 85 A 4 3630 495 19,0 88 Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" EC axial fans "Premium & Power" +2 76.5 0 +3 54 0 9. 5 16 EC axial fans "Basic" Ø318 0 +1 EC centrifugal fans - RadiCal backward-curved 0 +2 37 +2 24 ° X +20 300 0 ❮ "V" 1 2 3 Cable P. 62 Connection diagram P. 69 Technology 6 37 2015-10 5 4 Mating connector on customer circuit: Housing: Tyco 1-963212-1 Plug contacts: 2.5 mm Tyco 929938-1 (2x) 0.75 mm Tyco 929930-3 (4x) Seal: 828905-1 (2x) 828904-1 (4x) Detail X 1 = +UB black 2 = GND brown 3 = PWM/LIN* yellow *optional LIN-BUS 4 = INVLIN orange 5 = ABSENK blue 6 = diagnostic output white 6-pole coded Tyco Junior Power Timer; Cable (460 mm) with mating connector Part number 02002-4-1021 (not included in scope of delivery) Agents 330 +2 4x9 0° 5 7. Ø34 Ø3 EC axial fan for automotive applications, Ø 300 Sound power level Perm. ambient temp. Weight VDC m3/h rpm W A Pa dB(A) °C kg 27,5 16-32 2955 3000 200 7,7 320 86 Curves: Pa (1) 24-volt version -40..+105(2) 2,0 A 1.2 250 3 0.8 200 150 2 0.4 100 50 Pfs 0 qv 400 500 800 1000 1 1200 1500 2000 cfm 2500 m³/h 2015-10 Air performance measured according to: ISO 5801, installation category A, without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 38 P. 69 / D) (2) above +85 °C with power derating 4 300 Connection diagram Max. back pressure VDC in wg Subject to change A Input current M3G 084-BF Input power W3G 300-PW24 -01(1) Speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – Material: Housing: PA plastic, black (according to UL 94 HB) Blades: PA plastic, black (according to UL 94 HB) – Airflow direction: "A" (intake over the stator) – Direction of rotation: Clockwise viewed toward rotor – Degree of protection: Motor: IP 24 KM, electronics: IP 66 / 69 K – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 – Qualified in accordance with: DIN ISO 16750 – Approvals: EAC; E1 in preparation n rpm Ped W I A LWA dB(A) A 1 3000 200 7,70 86 A 2 2980 263 10,10 85 A 3 3010 310 11,93 83 A 4 2950 333 12,80 84 Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" 74,8 +2 0 EC axial fans "Premium & Power" 330 +2 0 +3 0 55 9, 5 14,5 Ø318 ±2 EC axial fans "Basic" 4x9 0° 5 7, Ø337 +20 Ø340 +2 0 Ø32 EC centrifugal fans - RadiCal backward-curved 2 +02 24 ° 75,6 +2 0 +20 0 300 2 6 3 Connection diagram P. 69 Technology 5 39 2015-10 4 Mating connector on customer circuit: Housing: Tyco 1-963212-1 Plug contacts: 2.5 mm Tyco 929938-1 (2x) 0.75 mm Tyco 929930-3 (4x) Seal: 828905-1 (2x) 1 828904-1 (4x) ❮ "A" Detail X 1 = +UB black 2 = GND brown 3 = PWM/LIN* yellow *optional LIN-BUS 4 = INVLIN orange 5 = ABSENK blue 6 = diagnostic output white 6-pole coded Tyco Junior Power Timer; Cable (460 mm) with mating connector Part number 02002-4-1021 (not included in scope of delivery) Agents X EC axial fan for automotive applications, Ø 385 Air flow Speed Input power Input current Max. back pressure Sound power level Perm. ambient temp. Weight Nominal data Type Motor VDC m3/h rpm W A Pa dB(A) °C kg W3G 385-CT53 -61(1) M3G 084-CF 13 9-16 4110 3100 445 34,0 --- 89 500 A 1,6 300 1,2 200 0,8 4 400 3 0,4 2 0 pfs 100 qV 500 500 1000 1000 1500 1500 2000 2500 2000 3000 3500 1 4000 cfm m 3/h 2015-10 Air performance measured according to: ISO 5801, installation category A, without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 40 -40..+105(2) 3,1 P. 68 / L) (2) above +70 °C with power derating 2,0 Curves: Pa (1) 12-volt version in H2O Subject to change A Connection diagram Nominal voltage range VDC Curve Nominal voltage – Material: Housing: PA plastic, black (according to UL 94 HB) Blades: PA plastic, black (according to UL 94 HB) – Airflow direction: "V" (intake over the rotor) – Direction of rotation: Clockwise viewed toward rotor – Degree of protection: Motor: IP 24 KM, electronics: IP 66 / 69 K – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 – Qualified in accordance with: DIN ISO 16750 – Approvals: EAC, E1 n rpm Ped W I A LWA dB(A) A 1 3100 445 34,0 89 A 2 3000 487 37,6 89 A 3 2930 544 41,9 87 A 4 2815 590 45,6 89 Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" EC axial fans "Premium & Power" +2 5 89.5 0 9. +3 55 0 16 Ø396 0 +2 399 +3 Ø41 Ø4 22 EC centrifugal fans - RadiCal backward-curved 4 +2 +2 24 ° X +20 0 270 2 1 3 Detail X 1 = +UB 2 = diagnostic output 3 = PWM/LIN* 4 = GND black white yellow brown Technology 4 *optional LIN-BUS Connection diagram P. 68 41 2015-10 Mating connector on customer circuit: Housing: DELPHI 13873952 Plug contacts: 9.5 mm DELPHI 10780235 4.8 mm DELPHI 10811289 Seal: DELPHI 15327788 DELPHI 10788269 ❮ "V" Agents 4x9 0° EC axial fans "Basic" 5 7. 17 ±1 EC axial fan for automotive applications, Ø 385 Sound power level Perm. ambient temp. Weight VDC m3/h rpm W A Pa dB(A) °C kg 26 16-32 3425 2600 260 10,0 --- 84 Pa in H2O 350 0,6 1,0 150 100 0,4 200 50 0,2 250 0,8 300 pfs 0 A qV 4 3 2 250 500 500 750 1000 1000 1500 1250 2000 1 cfm 1500 2500 3000 m 3/h 2015-10 Air performance measured according to: ISO 5801, installation category A, without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 42 P. 69 / D) (2) above +95 °C with power derating 1,2 Curves: -40..+110(2) 2,7 Connection diagram Max. back pressure VDC (1) 24-volt version 1,4 Subject to change A Input current M3G 084-BF Input power W3G 385-BV44 -01(1) Speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – Material: Housing: PA plastic, black (according to UL 94 HB) Blades: PA plastic, black (according to UL 94 HB) – Airflow direction: "V" (intake over the rotor) – Direction of rotation: Clockwise viewed toward rotor – Degree of protection: Motor: IP 24 KM, electronics: IP 66 / 69 K – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 – Qualified in accordance with: DIN ISO 16750 – Approvals: EAC, E1 n rpm Ped W I A LWA dB(A) A 1 2600 260 10,0 84 A 2 2505 272 10,5 83 A 3 2325 273 10,5 81 A 4 2215 274 10,5 82 Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" EC axial fans "Premium & Power" 5 79.5 +2 0 9. +3 55 0 16 Ø396 0 +2 Ø4 22 +2 0 EC centrifugal fans - RadiCal backward-curved 4 +2 0 24 ° X 5 2 6 3 Cable P. 62 Connection diagram P. 69 Technology 4 Mating connector on customer circuit: Housing: Tyco 1-963212-1 Plug contacts: 2.5 mm Tyco 929938-1 (2x) 0.75 mm Tyco 929930-3 (4x) Seal: 828905-1 (2x) 1 828904-1 (4x) ❮ "V" Detail X 1 = +UB black 2 = GND brown 3 = PWM/LIN* yellow *optional LIN-BUS 4 = INVLIN orange 5 = ABSENK blue 6 = diagnostic output white 6-pole coded Tyco Junior Power Timer; Cable (460 mm) with mating connector Part number 02002-4-1021 (not included in scope of delivery) 43 2015-10 +20 0 270 Agents 399 +30 4x9 EC axial fans "Basic" 0° 5 7. Ø41 EC axial fan for automotive applications, Ø 385 Sound power level Perm. ambient temp. Weight VDC m3/h rpm W A Pa dB(A) °C kg 26 16-32 3425 2600 260 10,0 --- 84 Pa in H2O 350 0,6 1,0 150 100 0,4 200 50 0,2 250 0,8 300 pfs 0 A qV 4 3 2 250 500 500 750 1000 1000 1500 1250 2000 1 cfm 1500 2500 3000 m 3/h 2015-10 Air performance measured according to: ISO 5801, installation category A, without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 44 P. 69 / D) (2) above +95 °C with power derating 1,2 Curves: -40..+110(2) 2,7 Connection diagram Max. back pressure VDC (1) 24-volt version 1,4 Subject to change A Input current M3G 084-BF Input power W3G 385-BS44 -01(1) Speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – Material: Housing: PA plastic, black (according to UL 94 HB) Blades: PA plastic, black (according to UL 94 HB) – Airflow direction: "V" (intake over the rotor) – Direction of rotation: Clockwise viewed toward rotor – Degree of protection: Motor: IP 24 KM, electronics: IP 66 / 69 K – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 – Qualified in accordance with: DIN ISO 16750 – Approvals: EAC, E1 n rpm Ped W I A LWA dB(A) A 1 2600 260 10,0 84 A 2 2505 272 10,5 83 A 3 2325 273 10,5 81 A 4 2215 274 10,5 82 Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" EC axial fans "Premium & Power" 5 79.5 +2 0 9. +3 55 0 16 Ø396 0 +2 Ø4 22 +2 0 EC centrifugal fans - RadiCal backward-curved 4 +2 0 24 ° X 1 2 6 3 Cable P. 62 Connection diagram P. 69 Technology 5 4 Mating connector on customer circuit: Housing: Tyco 1-963212-1 Plug contacts: 2.5 mm Tyco 929938-1 (2x) 0.75 mm Tyco 929930-3 (4x) Seal: 828905-1 (2x) 828904-1 (4x) ❮ "V" Detail X 1 = +UB black 2 = GND brown 3 = PWM/LIN* yellow *optional LIN-BUS 4 = INVLIN orange 5 = ABSENK blue 6 = diagnostic output white 6-pole coded Tyco Junior Power Timer; Cable (460 mm) with mating connector Part number 02002-4-1021 (not included in scope of delivery) 45 2015-10 +20 0 270 Agents 399 +30 4x9 EC axial fans "Basic" 0° 5 7. Ø41 EC axial fan for automotive applications, Ø 385 Air flow Speed Input power Input current Max. back pressure Sound power level Perm. ambient temp. Weight Nominal data Type Motor VDC m3/h rpm W A Pa dB(A) °C kg W3G 385-CT65 -21(1) M3G 084-CF 26 16-32 4375 3300 525 20,0 --- 90 600 500 A 1,6 4 400 1,2 3 300 0,8 100 0,4 2 200 pfs 500 qV 500 1000 1000 1500 1500 2000 2500 1 cfm 2000 3000 3500 4000 m 3/h 2015-10 Air performance measured according to: ISO 5801, installation category A, without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 46 -40..+110(2) 3,1 P. 68 / L) (2) above +85 °C with power derating 2,0 Curves: Pa (1) 24-volt version 2,4 in H2O Subject to change A Connection diagram Nominal voltage range VDC Curve Nominal voltage – Material: Housing: PA plastic, black (according to UL 94 HB) Blades: PA plastic, black (according to UL 94 HB) – Airflow direction: "V" (intake over the rotor) – Direction of rotation: Clockwise viewed toward rotor – Degree of protection: Motor: IP 24 KM, electronics: IP 66 / 69 K – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings – Motor protection: Thermal overload protection, reverse polarity and locked-rotor protection, load dump protection, undervoltage detection – EMC regulations: VDE 0879-2 – Qualified in accordance with: DIN ISO 16750 – Approvals: EAC, E1 n rpm Ped W I A LWA dB(A) A 1 3300 525 20,0 90 A 2 3180 615 23,7 89 A 3 3050 610 23,5 88 A 4 2920 610 23,6 88 Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" EC axial fans "Premium & Power" +2 5 89.5 0 9. +3 55 0 16 Ø396 0 +2 399 +3 Ø41 Ø4 22 EC centrifugal fans - RadiCal backward-curved 4 +2 +2 24 ° X +20 0 270 2 1 3 Detail X 1 = +UB 2 = diagnostic output 3 = PWM/LIN* 4 = GND black white yellow brown Technology 4 *optional LIN-BUS Connection diagram P. 68 47 2015-10 Mating connector on customer circuit: Housing: DELPHI 13873952 Plug contacts: 9.5 mm DELPHI 10780235 4.8 mm DELPHI 10811289 Seal: DELPHI 15327788 DELPHI 10788269 ❮ "V" Agents 4x9 0° EC axial fans "Basic" 5 7. 17 ±1 2015-10 48 49 Technology EC centrifugal fans - RadiCal backward-curved EC axial fans "Basic" EC axial fans "Premium & Power" EC dual centrifugal fans with housing "Basic" EC dual centrifugal fans with housing "Premium" with brushless DC motor "Basic" Agents 2015-10 EC axial fans Information EC axial fan for automotive applications, Ø 300 Sound power level Perm. ambient temp. Weight VDC m3/h rpm W A Pa dB(A) °C kg 26 18-32 2840 3100 250 9,60 --- 81 Pa in H2O 1,0 150 0,6 200 100 0,4 250 0,8 300 50 0,2 Curves: A 4 3 2 pfs qV 200 400 500 600 1000 1000 800 1500 1200 2000 1400 2500 1600 cfm m3/h 2015-10 Air performance measured according to: ISO 5801, installation category A, without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 50 P. 70 / M) (2) above +70 °C with power derating 1 0 -40..+85(2) 2,6 Connection diagram Max. back pressure VDC (1) 24-volt version 1,2 Subject to change A Input current M1G 074-CF Input power W1G 300-EC24 -01(1) Speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – Material: Housing: PP plastic, black (according to UL 94 HB) Blades: PA plastic, black (according to UL 94 HB) – Airflow direction: "V" (intake over the rotor) – Direction of rotation: Clockwise viewed toward rotor – Degree of protection: Motor: IP 24 KM, electronics: IP 66 / 69 K – Insulation class: "B" according to EN 60335-1 – Installation position: Any – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings – Motor protection: Locked-rotor protection – Approvals: E1 in preparation n rpm Ped W I A LWA dB(A) A 1 3100 250 9,60 81 A 2 2985 247 9,47 83 A 3 2945 246 9,45 83 A 4 2800 242 9,29 83 Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" EC axial fans "Premium & Power" On both sides for screws for fastening plastics, Ø 3.5 mm +2 91 54+1 330 28° Ø2.7/ 2.8 30 5 40 Ø3 EC centrifugal fans - RadiCal backward-curved 62 Ø318+1 4x90° EC axial fans "Basic" Ø3 5 9. 7. Ø 33 7 11 X ❮ "V" X Cable P. 62 Guard grille P. 63 3 Connection diagram P. 70 Technology 2 51 Agents 1 Detail X 1 = + UB 2 = 0–10 V 3 = GND 2015-10 Plug: Tyco MCP 2.8, 3-pole, coded Housing: Tyco MCP 2.8: 1-1718627-1 Plug contacts: 2.8 mm Tyco 1241388-1 and Tyco 1241396-1 Seal: 1.2–2.1mm Tyco 963294-1 and 2.7–3.0 mm Tyco 963292-1 Cable 02020-4-1021 with mating connector not included in scope of delivery. 2015-10 52 53 Technology EC centrifugal fans - RadiCal backward-curved EC axial fans "Basic" EC axial fans "Premium & Power" EC dual centrifugal fans with housing "Basic" EC dual centrifugal fans with housing "Premium" backward curved, with brushless DC motor Agents 2015-10 EC centrifugal fans - RadiCal Information EC centrifugal fan - RadiCal backward curved, for automotive applications, Ø 220 Air flow Speed Input power Input current Sound power level Perm. ambient temp. Weight Nominal data Type Motor VDC m3/h rpm W A dB(A) °C kg R1G 220-RD04 -03 M1G 074-BF A 12 8-16 920 2720 87 8,4 74 -40..+60 1,5 P. 72 / N) B R1G 220-RD87 -03 M1G 074-BF 24 16-28 1090 3130 120 6,5 78 -40..+60 1,5 P. 72 / N) Techn. features and connection diagram Nominal voltage range VDC Curve Nominal voltage – Material: Impeller: Glass-fiber reinforced PA plastic (according to UL 94 V0) Rotor: Galvanized Electronics housing: Die-cast aluminum, painted black – Number of blades: 7 – Direction of rotation: Clockwise viewed toward rotor – Degree of protection: Motor: IP 24 KM, electronics: IP 66 / 69 K – Insulation class: "B" – Installation position: Shaft horizontal or rotor on bottom, rotor on top on request – Condensation drainage holes: Rotor side – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings – Motor protection: Reverse polarity and locked-rotor protection – Approvals: EAC Pa 600 500 2.5 700 4 B 1.5 400 A 4 3 300 1 3 200 0.5 2 2 100 Pfs 0 qv 100 200 200 300 400 400 600 500 800 1 1 cfm 1000 m³/h 2015-10 Air performance measured according to: ISO 5801, installation category A, in ebm-papst inlet ring without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 54 n rpm Ped W I A LWA dB(A) A 1 2720 87 8,40 74 A 2 2645 87 8,53 71 A 3 2580 91 8,98 66 A 4 2675 87 8,44 69 B 1 3130 120 6,50 78 B 2 3065 124 6,69 75 B 3 2965 125 6,93 70 B 4 3060 123 6,69 73 2 Curves: in wg Subject to change Information EC dual centrifugal fans with housing "Premium" EC dual centrifugal fans with housing "Basic" EC axial fans "Premium & Power" Accessory part: inlet ring 09609-2-4013, not included in scope of delivery. 71±1 Ø252 Cable: FLRYW 4x 0.75 mm2, 4x crimped splices Inlet ring P. 63 Technology 2 Terminal assignment UN red PWM/LIN yellow DUE white GND blue Connection diagram P. 72 55 2015-10 21 450+20 6 85 ±10 Ø155 Ø220 +0.3 4x90° 0.8 EC centrifugal fans - RadiCal backward-curved M4 (4x) 1.8 Ø161 -0.5 EC axial fans "Basic" Ø58±0.15 R2 Ø88 45° Max. clearance for screw 6 mm 63.7 Agents 73.7 EC centrifugal fan - RadiCal backward curved, for automotive applications, Ø 250 Air flow Speed Input power Input current Sound power level Perm. ambient temp. Weight Nominal data Type Motor VDC m3/h rpm W A dB(A) °C kg R1G 250-RC67 -03 M1G 074-CF A 12 8-16 1030 2000 65 6,4 71 -40..+70 1,5 P. 72 / N) B R1G 250-RC75 -03 M1G 074-CF 24 16-28 1325 2550 130 7,1 76 -40..+60 1,5 P. 72 / N) Techn. features and connection diagram Nominal voltage range VDC Curve Nominal voltage – Material: Impeller: Glass-fiber reinforced PA plastic (according to UL 94 V0) Rotor: Galvanized Electronics housing: Die-cast aluminum, painted black – Number of blades: 7 – Direction of rotation: Clockwise viewed toward rotor – Degree of protection: Motor: IP 24 KM, electronics: IP 66 / 69 K – Insulation class: "B" – Installation position: Shaft horizontal or rotor on bottom, rotor on top on request – Condensation drainage holes: Rotor side – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings – Motor protection: Reverse polarity and locked-rotor protection – Approvals: EAC Pa 500 400 2.4 600 2.0 700 4 300 1.2 A 3 4 3 0.8 200 2 0 Pfs 100 0.4 2 qv 100 200 200 300 400 400 600 500 800 1 600 1000 700 1200 1 cfm m³/h 2015-10 Air performance measured according to: ISO 5801, installation category A, in ebm-papst inlet ring without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 56 n rpm Ped W I A LWA dB(A) A 1 2000 65 6,40 71 A 2 1935 69 6,85 66 A 3 1900 71 7,14 62 A 4 1975 67 6,60 65 B 1 2550 130 7,10 76 B 2 2445 131 7,45 72 B 3 2370 134 7,73 69 B 4 2410 132 7,59 70 B 1.6 Curves: 2.8 in wg Subject to change 1.5 Cable: FLRYW 4x 0.75 mm2, 4x crimped splices 450+20 Terminal assignment UN red PWM/LIN yellow DUE white GND blue Connection diagram P. 72 57 Technology EC centrifugal fans - RadiCal backward-curved M4 (4x) R2 8 EC axial fans "Basic" 45° Agents 31 85±10 Max. clearance for screw 6 mm 2015-10 6 Ø255 Ø240 85 Ø4.5 (4x) 91.5 ±1 4x 90° 2 Ø164.5 Ø250 Ø172.5+0.3 -0.5 Ø88 EC axial fans "Premium & Power" Accessory part: inlet ring 96359-2-4013 not included in scope of delivery. Ø58 ±0.15 EC dual centrifugal fans with housing "Basic" EC dual centrifugal fans with housing "Premium" Information EC centrifugal fan - RadiCal backward curved, for automotive applications, Ø 280 Perm. ambient temp. Weight VDC m3/h rpm W A dB(A) °C kg 26 16-32 2740 2350 252 10,5 80 -40..+60 3,0 Pa in H2O Curves: 600 A 500 2,0 4 400 1,6 300 1,2 3 200 0,8 100 0,4 2 1 pfs 0 qV 200 400 500 600 1000 800 1000 1500 1200 2000 1400 2500 cfm m3/h 2015-10 Air performance measured according to: ISO 5801, installation category A, in ebm-papst inlet ring without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 58 Techn. features and connection diagram Sound power level VDC P. 71 / P) (1) 24-volt version (also available as a 12-volt version) 2,4 Subject to change A Input current M3G 084-CF Input power R3G 280-RU26 -81(1) Speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – Material: Impeller: Glass-fiber reinforced PA plastic (according to UL 94 V0, EN 45545-2 / HL3) Rotor: Painted black Electronics housing: Die-cast aluminum, painted black – Number of blades: 5 – Direction of rotation: Clockwise viewed toward rotor – Degree of protection: Motor: IP 24 KM, electronics: IP 66 / 69 K – Insulation class: "B" – Installation position: Any – Condensation drainage holes: Rotor side – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings n rpm Ped W I A LWA dB(A) A 1 2350 252 10,5 80 A 2 2280 298 12,4 75 A 3 2265 309 12,9 73 A 4 2305 278 11,6 74 Information EC dual centrifugal fans with housing "Premium" Technical features: See connection diagram P. 71 Cable exit: To the side Protection class: III Approvals: EAC, E1 EC axial fans "Premium & Power" EC dual centrifugal fans with housing "Basic" – – – – 4x90° Max. clearance for screw 10 mm, tapping hole ready for self-tapping M5 screw. 45° 4x90° 31° Max. clearance for screw 12 mm, tapping hole ready for self-tapping M6 screw. Ø Ø 7 58 ± Ø 1 5 ± 0.2 0 Ø 1 15 ± .2 44 0.2 Connection diagram P. 71 59 Technology 75 ±10 8 1000 +20 Cable: 2x 2.5 mm2, 4x 1.0 mm2, 6x crimped ferrules Terminal assignment UN +26 VDC black GND brown PWM/LIN yellow INVLIN orange ABSENK blue DU white 2015-10 8 Accessory part: inlet ring 28000-2-4013 not included in scope of delivery. EC centrifugal fans - RadiCal backward-curved Ø260 Ø280 Ø179.6 Ø176.7 Ø187.5 Ø294 112 7 R 53 R 33 R1 1.25 46 127 148.5 ±1 (4x) EC axial fans "Basic" Ø4.5 (4x) (4x) (4x) Agents Max. clearance for screw 8 mm, tapping hole ready for self-tapping M4 screw. EC centrifugal fan - RadiCal backward curved, for automotive applications, Ø 280 Air flow Speed Input power Input current Sound power level Perm. ambient temp. Weight Nominal data Type Motor VDC m3/h rpm W A dB(A) °C kg R3G 280-RU65 -82 M3G 084-CF A 24 16-32 3345 2830 460 19,0 85 -40..+60 3,0 Techn. features and connection diagram Nominal voltage range VDC Curve Nominal voltage – Material: Impeller: Glass-fiber reinforced PA plastic (according to UL 94 V0, EN 45545-2 / HL3) Rotor: Painted black Electronics housing: Die-cast aluminum, painted black – Number of blades: 5 – Direction of rotation: Clockwise viewed toward rotor – Degree of protection: Motor: IP 24 KM, electronics: IP 66 / 69 K – Insulation class: "B" – Installation position: Any – Condensation drainage holes: Rotor side – Mode: Continuous operation (S1) – Mounting: Maintenance-free ball bearings P. 66 / S) Pa Curves: in wg Subject to change A n rpm Ped W I A LWA dB(A) 800 3 4 600 2 3 400 1 2 200 Pfs 0 qv 400 500 800 1000 1500 1200 2000 1cfm 1600 2500 3000 m³/h 2015-10 Air performance measured according to: ISO 5801, installation category A, in ebm-papst inlet ring without contact protection. Intake-side sound level: LwA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition. See Page 74 ff for detailed information. 60 A 1 2830 460 19,00 85 A 2 2830 595 24,69 81 A 3 2815 651 27,09 77 A 4 2845 631 26,19 77 Information EC dual centrifugal fans with housing "Premium" Technical features: See connection diagram P. 66 Cable exit: To the side Protection class: III Approvals: EAC, E1 in preparation EC axial fans "Premium & Power" EC dual centrifugal fans with housing "Basic" – – – – 4x90° Max. clearance for screw 10 mm, tapping hole ready for self-tapping M5 screw. 31° Max. clearance for screw 12 mm, tapping hole ready for self-tapping M6 screw. Ø Ø 7 58 ± Ø 1 5 ± 0.2 0 Ø 1 15 ± .2 44 0.2 Connection diagram P. 66 Technology Terminal assignment UN +26 VDC black GND brown PWM/LIN yellow DU white 61 2015-10 Cable: 2x 2.5 mm2, 2x 1.0 mm2, 4x crimped ferrules 75 ±10 8 1000 +20 Accessory part: inlet ring 28000-2-4013 not included in scope of delivery. EC centrifugal fans - RadiCal backward-curved Ø260 Ø280 Ø179.6 Ø176.7 Ø187.5 Ø294 112 7 R 53 R 33 R1 1.25 46 8 (4x) EC axial fans "Basic" Ø4.5 (4x) (4x) (4x) Agents Max. clearance for screw 8 mm, tapping hole ready for self-tapping M4 screw. 127 148.5 ±1 45° 4x90° Cables 460 25 8 02001-4-1021 Wire-end ferrule 60 460 25 8 02002-4-1021 Wire-end ferrule 60 460 30 Wire-end ferrule 02020-1-1021 8 70 Cables Part number Application 02001-4-1021 EC dual centrifugal fan with housing 02002-4-1021 EC axial fan 02020-1-1021 W1G 300-EC24-01 2015-10 Subject to change 62 Information EC dual centrifugal fans with housing "Premium" Accessories 120° Ø2.8 (6x) 129° 92 Ø2.1 (9x) Ø298.3 Ø140.5 ) (2x 56 ) (2x ) 2x 6( 16 EC dual centrifugal fans with housing "Basic" 70 EC axial fans "Premium & Power" 102° Guard grille Part number Application 18600-2-4039 W1G 300-EC24-01 Subject to change (Ø 5.5 ) 4x90° 6x6 45° Ø4.3 (4x) 0° 1.8 R2 EC axial fans "Basic" Ø5.5 (6x) EC centrifugal fans - RadiCal backward-curved 118 Ø245 Part number Application 09609-2-4013 R1G 220-RD87-02 *The inlet rings for the R1G 250 and R1G 280 are pictured fully dimensioned on the respective product pages. 63 2015-10 Subject to change Technology Inlet ring* Agents Ø155 (Ø 242) Ø252 42 Ø2 0.8 21 Connection diagram: A) 13 VDC (EC dual centrifugal fan with housing "Premium") Notes on various control possibilities and their applications 33 k 1 (black) 2 (yellow) UN +13 VDC 1k PWM/LIN RE typ. 75 k 0 V to 10 V PWM + 3 U - 10 k 4 12 V Speed setting PWM 1 kHz - 50 kHz 100 % PWM -> n=max 10 % PWM -> n=min 0 % PWM -> Standby Speed setting with potentiometer Full speed (brown) GND Speed setting 0 V - 10 V 10 V -> n=max 1 V -> n=min 0 V -> Standby Customer circuit Connection Fan Connection diagram: F) 26 VDC (EC dual centrifugal fan with housing "Basic") Notes on various control possibilities and their applications 1 UN +26 VDC 4.7 k 3 PWM/LIN RE typ. 75 k 0 V to 10 V (100 %) 4 + PWM U RE typ. 75 k (80 %) - 10 k RE typ. 75 k 5 (60 %) 12 V 6 2 Speed setting PWM 1 kHz - 50 kHz 10 V -> n=max 1 V -> n=min 0 V -> Standby Speed setting with potentiometer Speed setting 0 V - 10 V 10 V -> n=max 1 V -> n=min 0 V -> Standby 2015-10 Customer circuit 64 Full speed 80 % speed GND 60 % speed Connection Fan Information Connection diagram: H) EC dual centrifugal fans with housing "Premium" 26 VDC (EC axial fan "Premium") Notes on various control possibilities and their applications 1 (black) 3 (yellow) UB +26 VDC 4.7 k PWM/LIN RE typ. 22 k 0 V to 10 V + PWM U - 10 k Full speed Speed setting 0 V - 10 V 10 V -> n=max 1,5 V -> n=min 0 V -> Standby U Standby threshold UB 32 V (orange) INVLIN RE typ. 100 k 6 (white) Diagnostic output 0.05 k Diagnostic output Operation: output level low (U = 0 V) Rotor locked or overvoltage/undervoltage: output level high (U = UB - 2 V) Imax = 50 mA Collective fault signal possible 5 (blue) LOWER 47 k 2 (brown) Customer circuit Speed setting: 21 V -> n=min 0 V -> n=max UB -> Standby Speed - lower Input UB -> n/2 open -> n Connection EC axial fans "Premium & Power" UB 32 V - GND Fan EC axial fans "Basic" Motor turns 21 V U Motor stops Switch-on threshold EC centrifugal fans - RadiCal backward-curved 21 V + Technology Switch on: typ. 1.5 V off: typ. 1 V Full speed 4 Standby 65 Agents Speed setting with potentiometer 2015-10 Speed setting PWM 5 Hz - 100 kHz 100 % PWM -> n=max 15 % PWM -> n=min 0 % PWM -> Standby EC dual centrifugal fans with housing "Basic" The blower speed is determined by the input (pin 3, 4) that gives the higher speed. 12 V Connection diagram: S) 26 VDC (R3G 280-RU65-82) Technical features: • Control input 0–10 VDC / PWM • Fault output (high-side switch max. 30 mA) • Undervoltage detection • Temperature derating • Soft start / reverse polarity and locked-rotor protection • Thermal overload protection for electronics • Motor current limitation • Overvoltage detection • Load dump (58V) Customer circuit Full speed Connection Speed setting with potentiometer Speed setting 1 1 3 1 1K 4 0-10V 3 4 10V -> n=max 1.5V-> n=min <1V -> n=0 3 12V 10K 3 2 UB +26VDC 1 UB +26VDC GND PWM/LIN PWM/LIN 57K DIAG Speed setting with PWM 10Hz-50KHz 1 1K 3 4 100% PWM -> n=max 10% PWM -> n=min <10% PWM -> n=0 Diagnostic output Operation Output level Low 2 4 2015-10 2 GND 4 Connection Designation Color Assignment/function 1 UB +26 VDC black Power supply 26 VDC 2 DIAG white Diagnostic output 3 PWM/LIN yellow Analog voltage control input 0-10V or PWM 4 GND brown Power supply GND, reference ground 66 Fan / Motor 0.05K DIAG Information Connection diagram: K) Customer circuit Connection Speed setting Full speed Speed setting with potentiometer 1 1 1 3 2 1.5-10V Fan / Motor +UB +UB GND GND PWM/LIN 2 3 EC dual centrifugal fans with housing "Basic" • Motor current limitation • Overvoltage detection • Temperature derating • Load dump (58V) PWM/LIN 3 10V -> n = max 1.5V -> n = min <1V -> n = 0 EC axial fans "Premium & Power" Technical features: • Control input 0–10 VDC / PWM • Lowering input • Fault output (high-side switch max. 30mA) • Undervoltage detection • Power limiter • Reverse polarity and locked-rotor protection • Soft start • Thermal overload protection for electronics EC dual centrifugal fans with housing "Premium" 13 VDC (EC axial fan "Premium") DIAG 3 NC 2 4 ABSENK Speed setting with PWM 10Hz-50kHz 1 Diagnostic output Operation Output level Low 5 Speed lowering input DIAG 1 ABSENK 6 6 3 EC axial fans "Basic" 2 2 5 Color Assignment/function +UB black Power supply 2 GND brown Power supply GND, reference ground 3 PWM/LIN yellow Analog voltage control input 0-10 V or PWM 4 NC orange Not used / no function 5 ABSENK blue Lowering input 6 DIAG white Diagnostic output - Operation: Output level low (U = 0 V) - Rotor blocked or overvoltage/undervoltage Output level high (U = UB -2 V) - Imax = 50 mA - Collective fault signal possible Technology Designation 1 67 2015-10 Connection EC centrifugal fans - RadiCal backward-curved UB-> approx. n/2 open-> n Agents 100% PWM -> n = max 10% PWM -> n = min <10% PWM -> n = 0 Connection diagram: L) 13/26 VDC (EC axial fan "Power") Technical features: • Control input 0–10 VDC / PWM • Fault output (high-side switch max. 30 mA) • Undervoltage detection • Temperature derating / power limiter • Soft start / reverse polarity and locked-rotor protection • Thermal overload protection for electronics • Motor current limitation • Overvoltage detection • Load dump (58V) Customer circuit Connection Speed setting Full speed Speed setting with potentiometer 3 1 1 1 4 0-10V 3 4 3 10V -> n=max 1.5V-> n=min <1V -> n=0 3 2 +UB 1 GND PWM/LIN DIAG Diagnostic output Operation Output level Low 2 3 4 4 2015-10 100% PWM -> n=max 10% PWM -> n=min <10% PWM -> n=0 Connection Designation Color Assignment/function 1 +UB black Power supply 2 DIAG white Diagnostic output - Operation: Output level low (U = 0 V) - Rotor blocked or overvoltage/undervoltage Output level high (U = UB -2 V) - Imax = 50 mA - Collective fault signal possible 3 PWM/LIN yellow Analog voltage control input 0-10V or PWM 4 GND brown Power supply GND, reference ground 68 +UB GND 4 Speed setting with PWM 1-30KHz Fan / Motor PWM/LIN DIAG Information Connection diagram: D) Customer circuit Connection Speed setting Full speed Speed setting 1 1 3 1 2 1.5-10V 2 3 10V -> n = max 1.5V -> n = min <1V -> n = 0 4 EC dual centrifugal fans with housing "Basic" • Motor current limitation • Overvoltage detection • Temperature derating • Load dump (58V) Fan / Motor +UB +UB GND GND PWM/LIN 3 21V -> n = min 0V -> n = max UB -> standby PWM/LIN DIAG INVLIN 4 see curve A EC axial fans "Premium & Power" Technical features: • Control input 0–10 VDC / PWM • Lowering input • INVLIN (inverse linear control input) • Fault output (high-side switch max. 30mA) • Undervoltage detection • Power limiter • Reverse polarity and locked-rotor protection • Soft start • Thermal overload protection for electronics EC dual centrifugal fans with housing "Premium" 26 VDC (EC axial fan "Premium & Power") INVLIN ABSENK 5 Speed setting with PWM 10Hz-50kHz Speed setting with potentiometer Speed lowering input ABSENK DIAG 1 1 6 1 3 A: 3 U UB 2 2 5 EC axial fans "Basic" Standby threshold 100% PWM -> n = max 10% PWM -> n = min <10% PWM -> n = 0 32V UB-> approx. n/2 open-> n standby Switch on typ. 1.5V Switch off typ. 1V Diagnostic output Operation Output level Low Motor stops Switch-on threshold 6 21V EC centrifugal fans - RadiCal backward-curved Motor turns UB Color Assignment/function +UB black Power supply 2 GND brown Power supply GND, reference ground 3 PWM/LIN yellow Analog voltage control input 0-10 V or PWM 4 INVLIN orange Control input, inverse linear 5 ABSENK blue Lowering input 6 DIAG white Diagnostic output - Operation: Output level low (U = 0 V) - Rotor blocked or overvoltage/undervoltage Output level high (U = UB -2 V) - Imax = 50 mA - Collective fault signal possible Technology Designation 1 69 Agents Connection 32V 2015-10 21V 2 Connection diagram: M) 26 VDC (W1G 300-EC24-01) Technical features: • Control input 0–10 VDC / PWM • Undervoltage detection • Locked-rotor protection • Soft start • Thermal overload protection for electronics • Motor current limitation • Overvoltage detection Customer circuit Full speed Connection Speed adjustable via potentiometer Adjustable speed 2 1 Fan / Motor UN +24VDC 1 1 4.7K U1 1-10V 2 3 PWM/LIN 10K 2 2 47K 47K 3 GND 3 GND n max. n max. = PWM/LIN with +UB or 10 V respectively 100 %* 2200 rpm = PWM/LIN with 5,5 V respectively 55 %* 2200 rpm 1700 rpm = PWM/LIN with 2,0 V respectively 20 %* 1700 rpm 0 rpm = PWM/LIN with GND or 0 V respectively 0 % * With PWM control, the PWM level is defined with 10 V. 0 rpm 2015-10 1 2 Connection Designation Assignment/function 1 UB +24 VDC Power supply 24 VDC, maximum ripple 3.5% 2 PWM/LIN Analog voltage control input 0-10 V or PWM 3 GND Reference ground 70 3 4 5 6 7 8 9 10 U x1V PWM x 10% (10V) Information Connection diagram: P) Technical features: • Control input 0–10 VDC / PWM • Lowering input • INVLIN (inverse linear control input) • Fault output (high-side switch max. 30mA) • Undervoltage detection • Power limiter • Reverse polarity and locked-rotor protection • Soft start • Thermal overload protection for electronics Connection Speed adjustable via potentiometer 1 1 UB +26 VDC 1 3 1 +UB_24VDC GND 1.5-10V PWMLIN 2 10V -> n = max 1.5V -> n = min <1V -> n = 0 2 GND 2 3 Fan / Motor 3 12V 10K PWMLIN >43K 3 100K 47K DU INVLIN 2 EC axial fans "Premium & Power" Adjustable speed EC dual centrifugal fans with housing "Basic" • Motor current limitation • Overvoltage detection • Temperature derating • Load dump (58V) Customer circuit Full speed EC dual centrifugal fans with housing "Premium" 26 VDC (R3G 280-RU26-81) INVLIN 4 ABSENK Adjustable speed ABSENK 5 Lowering input speed DU 1 1 3 1 6 0.05K 4 A: 21V -> n = min 0V -> n = max UB -> standby 2 U UB Standby threshold 5 32V UB-> approx. n/2 open-> n EC axial fans "Basic" see curve A 100% PWM -> n = max 10% PWM -> n = min <10% PWM -> n = 0 standby Switch on typ. 1.5V Switch off typ. 1V Diagnostic output Nominal operation Output level low Motor stopped Switch-on threshold 6 21V Rotor locked Output level high (U = UB - 2V) I max = 30 mA Collective fault signal possible Motor turning Color Assignment/function UB +26 VDC black Power supply 26 VDC 2 GND brown Power supply GND, reference ground 3 PWM/LIN yellow Analog voltage control input 0-10 V or PWM 4 INVLIN orange Control input, inverse linear 5 ABSENK blue Lowering input 6 DU white Diagnostic output Technology Designation 1 32V 71 Agents Connection EC centrifugal fans - RadiCal backward-curved UB 21V 2 2015-10 Speed adjustable via PWM 10Hz-50kHz Connection diagram: N) 12/24 VDC (R1G 220/250) Technical features: • Control input 0–10 VDC / PWM • Tach output • Reverse polarity and locked-rotor protection • Soft start • Motor current limitation • Temperature derating Customer circuit Full speed Connection Speed adjustable via potentiometer Adjustable speed 1 1 2 Fan / Motor UN +24VDC UB 1 1-10V 4 2 10V -> n=max 1V -> n=min <1V -> n=0 Safe start-up at Unom -30% from 4V Ucontr. 2 12V 10K PWM/lin RE>100K 2 4 3 DUE 680R 47V Speed adjustable via PWM 1-10kHz Setting of values with ebm temperature controller 1 Reverse-polarity protection 1 T N 2 12V OUT 2 50003-1-0174 4 100% PWM -> n=max 10% PWM -> n=min <10% PWM -> n=0 Safe start-up at Unom -30% from 40% PWM 2015-10 GND P 33K 4 4 T<10°C -> n=0 T>45°C -> n=max Connection Designation Color Assignment/function 1 UN red Power supply 24 VDC, maximum ripple 3.5% 2 PWM/LIN yellow Control input Re > 100 K 3 DUE white Tach output, 3 pulses per revolution, Isink max. = 10 mA 4 GND blue Reference ground 72 DUE GND1 Information Connection diagram: Q) EC dual centrifugal fans with housing "Premium" 26 VDC (K3G 097-AS82-82) Connection Speed adjustable via potentiometer Adjustable speed 1 1 4 UB +26VDC 1 0-10V 2 10V -> n=max 1.5V-> n=min <1V -> n=0 4 12V 10K 2 1 UB GND 2 4 Fan / Motor GND PWMLIN 4 6 2 PWMLIN <30K DU DU EC axial fans "Premium & Power" Customer circuit Full speed EC dual centrifugal fans with housing "Basic" Technical features: • Control input 0–10 VDC / PWM • Fault output (open collector) • Undervoltage detection • Power limiter • Soft start • Thermal overload protection for electronics • Motor current limitation • Overvoltage detection • Load dump (58V) 2.1K Speed adjustable via PWM 10Hz-50KHz 1 4 2 EC axial fans "Basic" 100% PWM -> n=max 15% PWM -> n=min <10% PWM -> n=0 Diagnostic output Nominal operation Output level low 6 Assignment/function black Power supply 26 VDC 2 - UB 0 VDC brown Power supply GND, reference ground 4 PWM/LIN yellow Analog voltage control input 0-10V or PWM 6 DU white Diagnostic output Technology Color UB +26 VDC 73 Agents Designation 1 2015-10 Connection EC centrifugal fans - RadiCal backward-curved 2 Technical parameters and scope High standards for all ebm-papst products At ebm-papst we are always looking to improve our products to be able to offer customers just what they need for their particular requirements. Careful monitoring of the market enables us to constantly incorporate enhancements into our products. As shown by the technical parameters listed below, you can always be sure of finding the right solution from ebm-papst for whatever application you may have in mind. General performance parameters Service life Any deviations from the technical data and technical parameters described The service life of ebm-papst automotive products depends on: here are given in the product-specific data sheet. – The service life of the bearing system Degree of protection The degree of protection is specified in the product-specific data sheets. The service life of the bearing system is primarily governed by the thermal load on the bearings. Insulation class For the majority of our products we use maintenance-free ball bearings The insulation class is specified in the product-specific data sheets. which can be installed in any installation position. Installation position As a rough guide (depending on the general conditions), the ball bearings The installation position is specified in the product-specific data sheets. have a life expectancy L10 of approx. 40,000 hours of operation at an Condensation drainage holes ambient temperature of 40 °C. Information on condensation drainage holes is provided in the productspecific data sheets. We will gladly provide you with a life expectancy calculation based on your specific usage conditions. Mode of operation The mode of operation is specified in the product-specific data sheets. Motor protection/thermal protection Information on motor protection and thermal protection is provided in the Protection class product-specific data sheets. The protection class is specified in the product-specific data sheets. The following protection methods are provided depending on the typee of motor and area of application: – Thermal overload protector, in-circuit – PTC/NTC with electronic diagnostics 2015-10 – Current limitation via electronics 74 Information EC dual centrifugal fans with housing "Premium" Legal and normative specifications All ebm-papst products are subjected to comprehensive testing in confor- The products described in this catalog are developed and manufactured in mity with the normative specifications and also incorporating the extensive accordance with the standards applying to the particular product and, experience of ebm-papst. if known, in accordance with the conditions of the particular area of application. Vibration testing is performed as follows: Standards – Vibration test in operation according to DIN IEC 68 Part 2-6 Information on standards is provided in the product-specific data sheets. EC axial fans "Premium & Power" Vibration testing EC dual centrifugal fans with housing "Basic" Mechanical strain/performance parameters – Vibration test at standstill according to DIN IEC 68 Part 2-6 EMC Shock load Information on EMC standards is provided in the product-specific data Shock load testing is performed as follows: sheets. – Shock load according to DIN IEC 68 Part 2-27 Compliance with EMC standards has to be assessed on the final product, as EMC properties may change under different installation conditions. Approvals – Residual imbalance according to DIN ISO 1940 Please contact us if you require a specific Typee of approval (e1, UL, etc.) – Standard balancing quality level G 6.3 for your ebm-papst product. Should your particular application require a higher level of balancing, Most of our products can be supplied with the applicable approval. please contact us and specify the details in your order. Information on existing approvals is provided in the product-specific Chemical and physical strain/performance parameters EC axial fans "Basic" Balancing grade testing is performed as follows: data sheets. Please consult your ebm-papst contact for any questions regarding Air performance measurements chemical and physical strain. All air performance measurements are conducted on intake-side chamber Areas of use, industries & applications Our products are used in a variety of industries and for numerous applications: Ventilation, air conditioning and refrigeration technology, clean room technology, automotive and railway engineering, medical and laboratory technology, electronics, computer and office systems, telecommunications, household appliances, heating systems, machinery and installations, drive test rigs conforming to the requirements of ISO 5801 and DIN 24163. The fans under test are attached to the measuring chamber with free air intake EC centrifugal fans - RadiCal backward-curved Balancing grade and exhaust (installation category A) and operated at nominal voltage, with alternating current also at nominal frequency, without any additional attachments such as a guard grille. As required by the standards, the air performance curves shown are referenced to an air density of 1,15 kg/m3. engineering. Agents 75 2015-10 Technology Our products are not intended for use in the aerospace industry! Technical parameters and scope Air and sound measurement conditions Sound pressure and sound power level Measurements on ebm-papst products are taken under the following All acoustic values are determined in accordance with ISO 13347, DIN conditions: 45635 and ISO 3744/3745 as per accuracy class 2 and given in A-rated – Axial and diagonal fans in airflow direction "V" in full nozzle without form. – Backward-curved centrifugal fans, free-running with inlet ring guard grille For measurement of the sound pressure level Lp the microphone is located on the intake side of the fan being tested, generally at a distance of 1 m on – Forward-curved single and dual-inlet centrifugal fans with the fan axis. housing For measurement of the sound power level Lw 10 microphones are distributed over an enveloping surface on the intake side of the fan being tested Sound measurements (see graphic). The measured sound power level can be roughly calculated All sound measurements are taken in anechoic rooms with reverberant from the sound pressure level by adding 7 dB. floor. ebm-papst acoustic test chambers meet the requirements of accuracy class 1 as per DIN EN ISO 3745. For sound measurement, the fans being tested are positioned in a reverberant wall and operated at Measurement set-up according to ISO 13347-3 and DIN 45635-38: 10 measuring points nominal voltage, with alternating current also at nominal frequency, d≥D without any additional attachments such as a guard grille. h = 1,5d ... 4,5d D 1,5d Measurement area S = 6d2 + 7d (h + 1,5d) h 3d 2015-10 2d 76 Information 10 15 EC dual centrifugal fans with housing "Basic" EC dual centrifugal fans with housing "Premium" This means that a total level of 84 dB(A) is to be expected for the installation. EC axial fans "Premium & Power" pressure level of one fan is 75 dB(A). The level increase determined from the graph is 9 dB. 9 Example: There are 8 axial fans A3G800 on a condenser. According to the data sheet, the sound 5 values specified in the data sheet. This is shown in the adjacent graph. 0 The noise characteristics of several identical fans can be predicted on the basis of the sound [dB] [dB(A)] The addition of 2 sound sources with the same level produces a level increase of approx. 3 dB. Increase in sound pressure / sound power level Cumulative level of several sound sources with the same level 1 2 3 4 5 6 7 8 9 10 15 20 25 level of 76.5 dB(A) is to be expected for the unit. 3 2 EC axial fans "Basic" 4 dB. The level increase of approx. 1.5 dB can now be read off the graph. This means that a total 0 4 8 12 16 20 The sound power level is not governed by the distance from the noise source. By contrast, the -10 sound pressure level decreases with increasing distance from the sound source. The adjacent 0 [dB] [dB(A)] Distance laws 24 [dB] [dB(A)] Difference in level with two sources of sound EC centrifugal fans - RadiCal backward-curved dB(A) at the point of operation and one axial fan A3G710 with 71 dB(A). The difference in level is 1,5 Example: In a ventilation unit, there is one axial fan A3G800 with a sound pressure level of 75 1 specified in the data sheet. This is shown in the adjacent graph. 0 The noise characteristics of two different fans can be predicted on the basis of the sound values Increase in sound pressure / sound power level Cumulative level of two sound sources with different levels [dB] [dB(A)] Number of sources of sound with identical level graph shows the decrease in level under far field conditions. Far field conditions apply if there is and the level may decrease to a far lesser extent. The following example only applies to far field conditions and may vary considerably as a result of installation effects: For an axial fan A3G300, a sound pressure level of 65 dB(A) was measured at a distance of 1 m. From the adjacent graph, this would yield a reduction of 26 dB at a distance of 20 m, i.e. a sound -20 -26 1 Distance 2 5 10 20 50 Technology 6 dB each time the distance is doubled. Different relationships apply in the near field of the fan -30 be consulted for more detailed information on far fields. The level in the far field decreases by -40 the wavelength under consideration. On account of the complexity of the topic, literature should Decrease in sound pressure level a considerable distance between the microphone and the fan in relation to the fan diameter and 100 [m] Agents 77 2015-10 pressure level of 39 dB(A). ebm-papst in Germany 2015-10 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 74673 Mulfingen GERMANY Phone +49 7938 81-0 Fax +49 7938 81-110 [email protected] 78 ebm-papst St. Georgen GmbH & Co. KG Hermann-Papst-Straße 1 78112 St. Georgen GERMANY Phone +49 7724 81-0 Fax +49 7724 81-1309 [email protected] Berlin Dipl.-Ing. (TH) Jens Duchow Händelstraße 7 16341 Panketal GERMANY Phone +49 30 944149-62 Fax +49 30 944149-63 [email protected] Heilbronn / Heidelberg Dipl.-Ing. Mark Gartner Gehrweg 12 74199 Unterheinriet GERMANY Phone +49 7130 404569-1 Fax +49 7130 404569-2 [email protected] Bielefeld Dipl.-Ing. (FH) Wolf-Jürgen Weber Niehausweg 13 33739 Bielefeld GERMANY Phone +49 5206 91732-31 Fax +49 5206 91732-35 [email protected] Kassel Dipl.-Ing. (FH) Ralph Brück Hoherainstraße 3 b 35075 Gladenbach GERMANY Phone +49 6462 4071-10 Fax +49 6462 4071-11 [email protected] Dortmund Dipl.-Ing. (FH) Hans-Joachim Pundt Auf den Steinern 3 59519 Möhnesee-Völlinghausen GERMANY Phone +49 2925 800-407 Fax +49 2925 800-408 [email protected] Koblenz Winfried Schaefer Hinter der Kirch 10 56767 Uersfeld GERMANY Phone +49 2657 16-96 Fax +49 2657 16-76 [email protected] Frankfurt Dipl.-Ing. Christian Kleffmann Dr.-Hermann-Krause-Straße 23 63452 Hanau GERMANY Phone +49 6181 1898-12 Fax +49 6181 1898-13 [email protected] Munich Dipl.-Wirt.-Ing. (FH) Jens Peter Landsbergerstraße 14 86932 Pürgen GERMANY Phone +49 8196 99877-54 Fax +49 8196 99877-55 [email protected] Halle Dipl.-Ing. (TU) Michael Hanning Lercheneck 4 06198 Salzatal / OT Lieskau GERMANY Phone +49 345 55124-56 Fax +49 345 55124-57 [email protected] Nuremberg Dipl.-Wirt.-Ing. (FH) Axel Resch Dr.-August-Koch-Str. 1 91639 Wolframs-Eschenbach GERMANY Phone +49 9875 9783-170 Fax +49 9875 9783-171 [email protected] Hamburg Ingenieurbüro Breuell GmbH Ing. Dirk Kahl Elektroingenieur Oststraße 96 22844 Norderstedt GERMANY Phone +49 40 538092-19 Fax +49 40 538092-84 [email protected] Offenburg Dipl.-Ing. (FH) Ralf Braun Hubeneck 21 77704 Oberkirch GERMANY Phone +49 7802 9822-52 Fax +49 7802 9822-53 [email protected] fan agent Stuttgart Dipl.-Ing. (FH) Rudi Weinmann Hindenburgstraße 100/1 73207 Plochingen GERMANY Phone +49 7153 9289-80 Fax +49 7153 9289-81 [email protected] compact fan agent motor specialist ebm-papst Landshut GmbH Hofmark-Aich-Straße 25 84030 Landshut GERMANY Phone +49 871 707-0 Fax +49 871 707-465 [email protected] Ulm M.Sc. Reinhard Sommerreißer Am Germanenring 13 86674 Baar / Schwaben GERMANY Phone +49 8276 5899-775 Fax +49 8276 5899-776 [email protected] Distributors Frankfurt R.E.D. Handelsgesellschaft mbH Gutenbergstraße 3 63110 Rodgau - Jügesheim GERMANY Phone +49 6106 841-0 Fax +49 6106 841-111 [email protected] www.red-elektromechanik.de Hamburg Breuell + Hilgenfeldt GmbH Oststraße 96 22844 Norderstedt GERMANY Phone +49 40 538092-20 Fax +49 40 538092-84 [email protected] Munich A. Schweiger GmbH Ohmstraße 1 82054 Sauerlach GERMANY Phone +49 8104 897-0 Fax +49 8104 897-90 [email protected] www.schweiger-gmbh.com (1 to 5 pieces) North Breuell + Hilgenfeldt GmbH Oststraße 96 22844 Norderstedt GERMANY Phone +49 40 538092-20 Fax +49 40 538092-84 [email protected] South HDS Ventilatoren Vertriebs GmbH Glaswiesenstraße 1 74677 Dörzbach GERMANY Phone +49 7937 80355-20 Fax +49 7937 80355-25 [email protected] www.hds-gmbh.net motor agent Information Hungary ebm-papst Industries Kft. Ezred u. 2. 1044 Budapest HUNGARY Phone +36 1 8722-190 Fax +36 1 8722-194 offi[email protected] AuBren Limited Portlaoise Business & Technology Park Mountrath Road Portlaoise, Co. Laois IRELAND Phone +353 57 8664343 Fax +353 57 8664346 [email protected] www.aubren.com Finland ebm-papst Oy Puistotie 1 02760 Espoo FINLAND Phone +358 9 887022-0 Fax +358 9 887022-13 mailbox@ebmpapst.fi www.ebmpapst.fi Croatia ebm-papst Industries Kft. Ezred u. 2. 1044 Budapest HUNGARY Phone +36 1 8722-190 Fax +36 1 8722-194 offi[email protected] Italy ebm-papst Srl Via Cornaggia 108 22076 Mozzate (Co) ITALY Phone +39 0331 836201 Fax +39 0331 821510 [email protected] www.ebmpapst.it France ebm-papst sarl Parc d’Activités Nord 1 rue Mohler – BP 62 67212 Obernai Cedex FRANCE Phone +33 820 326266 Fax +33 3 88673883 [email protected] www.ebmpapst.fr fan agent compact fan agent EC centrifugal fans - RadiCal backward-curved Ireland ebm-papst UK Ltd. Chelmsford Business Park Chelmsford Essex CM2 5EZ UNITED KINGDOM Phone +44 1245 468555 Fax +44 1245 466336 [email protected] www.ebmpapst.co.uk Estonia ebm-papst Oy, Eesti Filiaal Kesk tee 13 Aaviku küla, Jüri Tehnopark 75301 Rae Vald, Harjumaa ESTONIA Phone +372 65569-78 Fax +372 65569-79 www.ebmpapst.ee Bulgaria ebm-papst Romania S.R.L. Str. Tarnavei No. 20 500327 Brasov ROMANIA Phone +40 268 331859 Fax +40 268 312805 [email protected] EC axial fans "Basic" Iceland RJ Engineers Stangarhyl 1a 110 Reykjavik ICELAND Phone +354 567 8030 Fax +354 567 8015 [email protected] www.rj.is Denmark ebm-papst Denmark ApS Vallensbækvej 21 2605 Brøndby DENMARK Phone +45 43 631111 Fax +45 43 630505 [email protected] www.ebmpapst.dk Belgium ebm-papst Benelux B.V. Sales office Belgium-Luxemburg Romeinsestraat 6/0101 Research Park Haasrode 3001 Heverlee-Leuven BELGIUM Phone +32 16 396-200 Fax +32 16 396-220 [email protected] www.ebmpapst.be EC axial fans "Premium & Power" Czech Republic / Slovakia ebm-papst CZ s.r.o. Kaštanová 34a 620 00 Brno CZECH REPUBLIC Phone +420 544 502-411 Fax +420 547 232-622 [email protected] www.ebmpapst.cz motor specialist motor agent Technology Belarus ebm-papst Bel AgmbH Lipkovskaya Gasse 34 Office No.6, Room 106,107 223010 Minsk BELARUS Phone +375 17 3851556 Fax +375 17 3851556 [email protected] www.ebmpapst.by Greece Helcoma E. Rota and Co. OE Davaki 65 17672 Kallithea-Attiki GREECE Phone +30 210 9513-705 Fax +30 210 9513-490 [email protected] www.helcoma.gr 79 Agents Austria ebm-papst Motoren & Ventilatoren GmbH Straubingstraße 17 4030 Linz AUSTRIA Phone +43 732 321150-0 Fax +43 732 321150-20 [email protected] www.ebmpapst.at Cyprus Helcoma E. Rota and Co. OE Davaki 65 17672 Kallithea-Attiki GREECE Phone +30 210 9513-705 Fax +30 210 9513-490 [email protected] www.helcoma.gr 2015-10 Europe EC dual centrifugal fans with housing "Basic" EC dual centrifugal fans with housing "Premium" ebm-papst in Europe ebm-papst in Europe Macedonia ebm-papst Industries Kft. Ezred u. 2. 1044 Budapest HUNGARY Phone +36 1 8722-190 Fax +36 1 8722-194 offi[email protected] Romania ebm-papst Romania S.R.L. Str. Tarnavei Nr. 20 500327 Brasov ROMANIA Phone +40 268 331859 Fax +40 268 312805 [email protected] Netherlands ebm-papst Benelux B.V. Polbeemd 7 - 5741 TP Beek en Donk P.O. Box 140 - 5740 AC Beek en Donk NETHERLANDS Phone +31 492 502-900 Fax +31 492 502-950 [email protected] www.ebmpapst.nl Russia ebm-papst Ural GmbH Posadskaja-Strasse, 23(E), 3 620102 Ekaterinburg RUSSIA Phone +7 343 2338000 Fax +7 343 2337788 [email protected] www.ebmpapst.ur.ru ebm-papst Heating Systems B.V. Van Veldekekade 360 5216 KT ‘s-Hertogenbosch NETHERLANDS Phone +31 73 648 89 00 Fax +31 73 648 89 11 [email protected] www.ebmpapst-hs.nl ebm-papst Rus GmbH proezd 4529, vladenie 5, stroenie 1 141000 Mytistschi, Oblast Moskau RUSSIA Phone +7 495 9807524 Fax +7 495 5140924 [email protected] www.ebmpapst.ru Serbia & Montenegro ebm-papst Industries Kft. Ezred u. 2. 1044 Budapest HUNGARY Phone +36 1 8722-190 Fax +36 1 8722-194 offi[email protected] Norway ebm-papst AS P.B. 173 Holmlia 1203 Oslo NORWAY Phone +47 22 763340 Fax +47 22 619173 [email protected] www.ebmpapst.no Poland ebm-papst Polska Sp. z o.o. ul. Annopol 4A 03236 Warszawa POLAND Phone +48 22 6757819 Fax +48 22 6769587 offi[email protected] www.ebmpapst.pl 2015-10 Portugal ebm-papst (Portugal), Lda. Centro Empresarial de Alverca Rua de Adarse, Vale D’Ervas Corpo D / Fracção 3 2615-178 Alverca do Ribatejo PORTUGAL Phone +351 218 394 880 Fax +351 218 394 759 [email protected] www.ebmpapst.pt 80 fan agent Spain ebm-papst Ibérica S.L. Avda. del Sistema Solar, 29 28830 San Fernando de Henares (Madrid) SPAIN Phone +34 91 6780894 Fax +34 91 6781530 [email protected] www.ebmpapst.es Sweden ebm-papst AB Äggelundavägen 2 17562 Järfälla SWEDEN Phone +46 10 4544400 Fax +46 8 362306 [email protected] www.ebmpapst.se compact fan agent motor specialist Switzerland ebm-papst AG Rütisbergstrasse 1 8156 Oberhasli SWITZERLAND Phone +41 44 73220-70 Fax +41 44 73220-77 [email protected] www.ebmpapst.ch Turkey Akantel Elektronik San. Tic. LTD. Sti. Atatürk Organize Sanayi Bölgesi 10007 SK. No.:6 35620 Cigli-Izmir TURKEY Phone +90 232 3282090 Fax +90 232 3280270 [email protected] www.ebmpapst.com.tr Ukraine ebm-papst Ukraine LLC Lepse Boulevard, 4, Building 21 03067 Kiev UKRAINE Phone +38 044 2063091 Fax +38 044 2063091 [email protected] www.ebmpapst.ua United Kingdom ebm-papst UK Ltd. Chelmsford Business Park Chelmsford Essex CM2 5EZ UNITED KINGDOM Phone +44 1245 468555 Fax +44 1245 466336 [email protected] www.ebmpapst.co.uk ebm-papst Automotive & Drives (UK) Ltd. The Smithy Fidlers Lane East Ilsley, Berkshire RG20 7LG UNITED KINGDOM Phone +44 1635 2811-11 Fax +44 1635 2811-61 A&[email protected] www.ebmpapst-ad.com motor agent Information Argentina ebm-papst de Argentina S.A. Hernandarias 148 Lomas del Mirador Pcia. de Buenos Aires (1752) ARGENTINA Phone +54 11 46576135 Fax +54 11 46572092 [email protected] www.ebmpapst.com.ar Brasil ebm-papst Motores Ventiladores Ltda. Av. José Giorgi, 301 Galpões B6+B7 Condominio Logical Center 06707-100 Cotia - São Paulo BRAZIL Phone +55 11 4613-8700 Fax +55 11 4777-1456 [email protected] www.ebmpapst.com.br Africa USA ebm-papst Inc. P.O. Box 4009 100 Hyde Road Farmington, CT 06034 UNITED STATES Phone +1 860 674-1515 Fax +1 860 674-8536 [email protected] www.ebmpapst.us South Africa ebm-papst South Africa (Pty) Ltd. P.O. Box 3124 1119 Yacht Avenue 2040 Honeydew SOUTH AFRICA Phone +27 11 794-3434 Fax +27 11 794-5020 [email protected] www.ebmpapst.co.za ebm-papst Automotive & Drives, Inc. 3200 Greenfield, Suite 255 Dearborn, MI 48120 UNITED STATES Phone +1 313 406-8080 Fax +1 313 406-8081 [email protected] www.ebmpapst-automotive.us EC axial fans "Premium & Power" America EC dual centrifugal fans with housing "Basic" EC dual centrifugal fans with housing "Premium" ebm-papst in America and Africa EC axial fans "Basic" Canada ebm-papst Canada Inc. 1800 Ironstone Manor, Unit 2 Pickering, Ontario, L1W3J9 CANADA Phone +1 905 420-3533 Fax +1 905 420-3772 [email protected] www.ebmpapst.ca compact fan agent motor specialist motor agent 81 Agents fan agent 2015-10 Technology EC centrifugal fans - RadiCal backward-curved Mexico ebm Industrial S. de R.L. de C.V. Paseo de Tamarindos 400-A-5to Piso Col. Bosques de las Lomas Mexico 05120, D.F. MEXICO Phone +52 55 3300-5144 Fax +52 55 3300-5243 [email protected] www.ebmpapst.com.mx ebm-papst in Asia Asia China ebm-papst Ventilator (Shanghai) Co., Ltd. No. 418, Huajing Road WaiGaoQiao Free Trade Zone No. 2001, Yang Gao (N) Road 200131 Shanghai P.R. of CHINA Phone +86 21 5046-0183 Fax +86 21 5046-1119 [email protected] www.ebmpapst.com.cn 2015-10 Hong Kong ebm-papst Hong Kong Ltd. Room 17E, MG Tower 133 Hoi Bun Road, Kwun Tong Hong Kong P.R. of CHINA Phone +852 2145-8678 Fax +852 2145-7678 [email protected] Japan ebm-papst Japan K.K. Attend on Tower 13F Shinyokohama 2-8-12, Kohoku-ku 222-0033 Yokohama-City, Kanagawa JAPAN Phone +81 45 47057-51 Fax +81 45 47057-52 [email protected] www.ebmpapst.jp Korea ebm-papst Korea Co. Ltd. 6F, Trutec Bldg. 12, WorldCupbuk-ro 56-gil Mapo-Gu Seoul 121-835 KOREA Phone +82 2 366213-24 Fax +82 2 366213-26 [email protected] www.ebmpapst.co.kr India ebm-papst India Pvt. Ltd. 26/3, G.N.T. Road, Erukkencherry Chennai-600118 INDIA Phone +91 44 25372556 Fax +91 44 25371149 [email protected] www.ebmpapst.in Malaysia ebm-papst Malaysia Representative Office Unit 12-2, Jalan USJ Sentral 3 Persiaran Subang, Selangor Darul Ehsan 47600 Subang Jaya MALAYSIA Phone +60 3 8024-1680 Fax +60 3 8024-8718 [email protected] Indonesia ebm-papst Indonesia Representative Office German Centre, 4th Floor, Suite 4470 Jl. Kapt. Subijono Dj. Bumi Serpong Damai 15321 Tangerang INDONESIA Phone +62 21 5376250 Fax +62 21 5388305 [email protected] Philippines ebm-papst SEA Pte. Ltd. Representative Office (Philippines) ALPAP II Building Trade Street Corner Investment Drive Unit 1101 Madrigal Business Park 1799 Ayala Alabang / Muntinlupa City Telefon: +63 02 8042747 Telefax: +63 02 8042757 [email protected] Israel Polak Bros. Import Agencies Ltd. 9 Hamefalsim Street Kiryat Arie, Petach-Tikva 49514 ISRAEL Phone +972 3 9100300 Fax +972 3 5796679 [email protected] www.polak.co.il Singapore ebm-papst SEA Pte. Ltd. No. 23 Ubi Road 4 #06-00 Olympia Industrial Building Singapore 408620 SINGAPORE Phone +65 65513789 Fax +65 68428439 [email protected] fan agent compact fan agent motor specialist Taiwan ETECO Engineering & Trading Corp. 10F-I, No. 92, Teh-Wei Str. Tsow-Inn District, Kaohsiung TAIWAN Phone +886 7 557-4268 Fax +886 7 557-2788 [email protected] www.ebmpapst.com.tw Thailand ebm-papst Thailand Co., Ltd. 99/9 Moo 2, Central Chaengwattana Tower 14th Floor, Room 1402 Chaengwattana Road Bangtarad, Pakkret 11120 Nonthaburi THAILAND Phone +66 2 8353785-7 Fax +66 2 8353788 [email protected] United Arab Emirates ebm-papst Middle East FZE PO Box 17755 Jebel Ali Free Zone / FZS1 / AP05 Dubai UNITED ARAB EMIRATES Phone +971 4 88608-26 Fax +971 4 88608-27 [email protected] www.ebmpapst.ae Vietnam ebm-papst SEA Pte. Ltd. Representative Office Room 402, 4th Floor, Sai Gon 3 Building 140 Nguyen Van Thu, District 1 Ho Chi Minh City VIETNAM Phone +84 8 39104099 / 39103969 Fax +84 8 39103970 [email protected] motor agent Information EC dual centrifugal fans with housing "Basic" EC dual centrifugal fans with housing "Premium" ebm-papst in Oceania Oceania EC axial fans "Premium & Power" Australia ebm-papst A&NZ Pty Ltd. 10 Oxford Road Laverton North, Victoria, 3026 AUSTRALIA Phone +61 3 9360-6400 Fax +61 3 9360-6464 [email protected] www.ebmpapst.com.au compact fan agent motor specialist motor agent 83 Agents fan agent 2015-10 Technology EC centrifugal fans - RadiCal backward-curved EC axial fans "Basic" New Zealand ebm-papst A&NZ Pty Ltd. 61 Hugo Johnston Drive, Unit H Penrose 1061, Auckland NEW ZEALAND PO Box 112278, Penrose 1642, Auckland Phone +64 9 525-0245 Fax +64 9 525-0246 [email protected] www.ebmpapst.com.au www.ebmpapst.com ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 74673 Mulfingen Germany Phone +49 7938 81-0 Fax +49 7938 81-110 [email protected] 37659-7-8811 · 2015-10 · KH-2’ Printed in Germany