Axial-fan Centrifugal-fan AC-60Hz EN

60 Hz: Axial and centrifugal fans
with AC motor sizes 094/110/138
The engineer's choice
Version 07/2009
Large AC fans for 60 Hz applications
Centrifugal and axial fans with robust, asynchronous design external rotor motors have
always been given great priority at ebm-papst.
New sizes of fans with AC drives are now available from ebm-papst.
But all the benefits of the products have remained the same: These are fans that require
little depth for installation, produce low noise levels and have outstanding efficiency. This
combination makes our new AC fan series the number one choice of project and design
engineers in ventilation, air conditioning and refrigeration technology.
Robust and versatile
Asynchronous external rotor motors in sizes of 110 and 138 have been developed as drives for axial
fans with blade diameters from 500 mm to 910 mm, for backward curved centrifugal fans with
impeller diameters from 450 mm to 630 mm, and forward curved centrifugal fans with impeller
diameters from 250 mm to 400 mm. The latest motors are available in 4, 6, 8 and 12-pole versions
and in a variety of installation lengths.
Depending on the motor size, the axial fans have sickle-shaped plastic blades (HyBlade®) or die-cast
blades; in both variants, the blade ends have been optimised by using "winglets". This guarantees
particularly quiet operation and, at the same time, high efficiency. Different blade angles for each
diameter make it possible to configure almost any operating point required.
A strong connection
In designing the HyBlade® axial fan blades, ebm-papst was the first to use a high-strength,
corrosion-resistant aluminium alloy carrier with a jacket of special, fibre-reinforced plastic.
Using the two materials together form an ideal combination of their individual characteristics. The aluminium inlet can withstand the mechanical forces during operation and ensures a durable connection
to the rotor, while the plastic encapsulates the carrier structure, giving the blade its optimised aerodynamic shape. At the same time, the plastic jacket has a positive effect on the total weight of the fan.
Two features add to the considerable noise reduction as compared to conventional blades: The aerodynamically optimised and profiled contour, and the simple addition of "winglets" to the ends of the
blades.
For backward curved centrifugal fans up to 630 mm in diameter, an impeller with three-dimensional
backward curved blades is used, which likewise provides the best possible results in terms of noise
and efficiency.
The forward curved centrifugal fans, with impeller diameters from 250 mm to 400 mm, are able to be
used with the existing external rotor motors of sizes 094, 110 and 138.
These innovative new fans, with their outstanding designs, are the result of intensive research,
are based on our many years of experience, and are supported by extensive simulations and complex
calculations.
2
General information
AC axial fans
2
AC axial fans Ø 500 - Ø 910
5
AC centrifugal fans, backward curved Ø 450 - Ø 630
67
AC centrifugal fans, forward curved Ø 250 - Ø 400
87
119
Electrical connections
126
ebm-papst representatives & subsidiaries
128
3
Representatives
Electrical connections
Accessories
Accessories
AC centrifugal, forward
Large AC fans for 60 Hz applications
AC centrifugal, backward
Table of contents
4
Accessories
AC centrifugal, forward
AC centrifugal, backward
Ø 500 - Ø 910
Electrical connections
AC axial fans
5
AC axial fans
6
Representatives
General information
AC axial fans
AC axial fans - HyBlade®
Ø 500
Electr. connection
D
0°
E
F
G
M8D 110-EF
Perm. amp. temp.
B
C
*8D 500
Max. operative range
0°
M6D 110-EF
Capacitor
A
*6D 500
Max. current draw (1)
M4D 110-GF
Max. power input (1)
*4D 500
Speed (1)
Motor
Frequency
Type
Nominal voltage
Nominal data
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 126
3~ 480 Y
3~ 400 Y
3~ 230 Δ
3~ 480 Y
3~ 400 Y
3~ 230 Δ
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
60
60
60
60
60
60
1590
1510
1510
1095
1050
1050
815
785
785
1.05
0.95
0.95
0.41
0.38
0.38
0.21
0.18
0.18
1.57
1.60
2.77
0.72
0.70
1.22
0.45
0.41
0.71
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Pressed-on round sheet steel plate, extrusion-coated in PP plastics
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise,
direction of air flow "A" clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
0°
H
I
—
—
—
—
—
—
—
—
—
2
[Pa]
[in H O]
Curves
160
0,6
3
3
140
0,4
0,5
A
100
2
3
3
D
0,3
B
C
2
60
2
0,2
1
1
0,1
E
F
1000
2000
6
F1b)/F2b)
F1b)/F2b)
2000
3000
4000
4000
6000
5000
8000
6000 [CFM]
10000 [m /h]
3
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
1
1630
0.90
1.41
76
A
2
1615
0.96
1.47
75
A
3
1590
1.05
1.57
74
B
1
1565
0.82
1.41
76
B
2
1540
0.88
1.49
74
B
3
1510
0.95
1.60
73
C
1
1565
0.82
2.44
76
C
2
1540
0.88
2.58
74
C
3
1510
0.95
2.77
73
D
1
1120
0.34
0.67
68
D
2
1110
0.37
0.68
66
D
3
1095
0.41
0.72
66
E
1
1085
0.31
0.60
67
E
2
1075
0.34
0.63
65
E
3
1050
0.38
0.70
65
F
1
1085
0.31
1.07
67
F
2
1075
0.34
1.09
65
F
3
1050
0.38
1.22
65
1
1
40
0
F1b)/F2b)
A
2
80
20
-40 to +60
-40 to +60
-40 to +60
-40 to +65
-40 to +65
-40 to +65
-40 to +65
-40 to +65
-40 to +65
(1) Nominal data in operating point 3 with maximum load
subject to alterations
120
160
145
145
100
93
93
55
50
50
General information
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
"A" ❯
"A" ❯
With guard grille
for full nozzle
With guard grille
for short nozzle
"V"
"A"
A4D 500-AM01 -03
A4D 500-AM01 -04
W4D 500-GM01 -03
W4D 500-DM01 -04
S4D 500-CM01 -03
—
S4D 500-AM01 -03
—
—
S4D 500-BM01 -04
—
S4D 500-AM01 -04
"V"
"A"
A6D 500-AJ01 -03
A6D 500-AJ01 -04
W6D 500-GJ01 -03
W6D 500-DJ01 -04
S6D 500-CJ01 -03
—
S6D 500-AJ01 -03
—
—
S6D 500-BJ01 -04
—
S6D 500-AJ01 -04
"V"
"A"
A8D 500-AJ05 -03
A8D 500-AJ05 -04
W8D 500-GJ05 -03
W8D 500-DJ05 -04
S8D 500-CJ05 -03
—
S8D 500-AJ05 -03
—
—
S8D 500-BJ05 -04
—
S8D 500-AJ05 -04
2
0,22 [in H O]
[Pa]
Curves
50
3
0,20
55
40
0,18
0,16
45
2
0,12
25
20
P1
[kW]
I
[A]
LwA
[dB(A)]
1
835
0.18
0.42
61
G
2
825
0.19
0.43
59
G
3
815
0.21
0.45
59
H
1
805
0.16
0.37
61
H
2
795
0.17
0.38
59
H
3
785
0.18
0.41
57
I
1
805
0.16
0.64
61
I
2
795
0.17
0.66
59
I
3
785
0.18
0.71
57
H
I
0,08
30
0,10
35
0,14
2
n
[rpm]
G
3
G
AC centrifugal, backward
❮ "V"
With guard grille
for short nozzle
AC centrifugal, forward
❮ "V"
With guard grille
for full nozzle
Accessories
❮ "V"/ "A" ❯
With full square
nozzle
Electrical connections
❮ "V"/ "A" ❯
Without attachments
1
10
0,04
5
0,02
15
0,06
1
0
500
1000
1000
1500
2000
2000
3000
2500
4000
3000
[CFM]
5000
[m3/h]
7
Drawings
p. 10 f.
Motor protection
p. 122 f.
Electr. connections
p. 126
Representatives
Direction of air flow
AC axial fans
–
–
–
–
–
AC axial fans - HyBlade®
Ø 500
Nominal voltage
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Max. operative range
Perm. amp. temp.
Electr. connection
Nominal data
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 126
1~ 230
60
1400
0.88
3.88
12.0/450
100
-40 to +40
A2b)
B
1~ 230
60
1015
0.39
1.72
8.0/400
90
-40 to +65
A2b)
C
1~ 230
60
740
0.17
0.75
3.0/400
45
-40 to +65
A2b)
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Pressed-on round sheet steel plate, extrusion-coated in PP plastics
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise,
direction of air flow "A" clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Type
Motor
*4E 500
M4E 110-GF
0°
A
*6E 500
M6E 110-EF
0°
*8E 500
M8E 110-EF
0°
(1) Nominal data in operating point 3 with maximum load
subject to alterations
2
[Pa]
[in H O]
Curves
110
3
90
80
A
0,3
B
70
2
60
2
0,2
50
40
1
30
0,1
1
20
10
0
1000
2000
8
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1485
0.83
3.61
75
A
2
1450
0.85
3.73
73
A
3
1400
0.88
3.88
72
B
1
1075
0.36
1.59
67
B
2
1050
0.38
1.65
65
B
3
1015
0.39
1.72
65
3
0,4
100
n
[rpm]
2000
3000
4000
4000
6000
5000
8000
[CFM]
[m3/h]
General information
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
❮ "V"
❮ "V"
"A" ❯
"A" ❯
With guard grille
for full nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
"V"
"A"
A4E 500-AM03 -01
A4E 500-AM03 -02
W4E 500-GM03 -01
W4E 500-DM03 -02
S4E 500-CM03 -01
—
S4E 500-AM03 -01
—
—
S4E 500-BM03 -02
—
S4E 500-AM03 -02
"V"
"A"
A6E 500-AJ03 -01
A6E 500-AJ03 -02
W6E 500-GJ03 -01
W6E 500-DJ03 -02
S6E 500-CJ03 -01
—
S6E 500-AJ03 -01
—
—
S6E 500-BJ03 -02
—
S6E 500-AJ03 -02
"V"
"A"
A8E 500-AJ03 -01
A8E 500-AJ03 -02
W8E 500-GJ03 -01
W8E 500-DJ03 -02
S8E 500-CJ03 -01
—
S8E 500-AJ03 -01
—
—
S8E 500-BJ03 -02
—
S8E 500-AJ03 -02
2
0,22 [in H O]
[Pa]
Curves
50
0,20
45
0,18
40
0,16
55
AC centrifugal, backward
❮ "V"/ "A" ❯
With full square
nozzle
AC centrifugal, forward
❮ "V"/ "A" ❯
Without attachments
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
C
1
780
0.15
0.67
61
C
2
760
0.16
0.71
58
C
3
740
0.17
0.75
56
Accessories
Direction of air flow
AC axial fans
–
–
–
–
–
3
5
0
Electrical connections
1
500
1000
1000
1500
2000
2000
3000
2500
4000
3000
[CFM]
5000
[m3/h]
9
Drawings
p. 10 f.
Motor protection
p. 122 f.
Electr. connections
p. 126
Representatives
0,14
0,08
10
0,04
15
0,02
20
0,06
25
2
0,10
30
0,12
C
35
AC axial fans - HyBlade®
Ø 500, drawings for direction of air flow "V"
Type
Without attachments
A4D
A6D
A8D
A4E
A6E
A8E
g
10.5
209.5
8.5
189.5
8.5
189.5
10.5
209.5
8.5
189.5
8.5
189.5
497±2
99x99
115±0,3
112
500-AM01 -03
500-AJ01 -03
500-AJ05 -03
500-AM03 -01
500-AJ03 -01
500-AJ03 -01
Mass
[kg]
Internal diameter of the
wall ring at least 503 mm
65,5
g±2
4xM6
Depth of screw
max. 12 mm
Screwed cable gland
❮ "V"
With full square nozzle
Mass
[kg]
W4D 500-GM01 -03
W6D 500-GJ01 -03
W8D 500-GJ05 -03
W4E 500-GM03 -01
W6E 500-GJ03 -01
W8E 500-GJ03 -01
18.0
Type
Mass
[kg]
t
12.7
144.0
10.7
124.0
10.7
124.0
12.7
144.0
10.7
124.0
10.7
124.0
16.0
16.0
18.0
16.0
16.0
Ø11
535
176±5
Type
16
120
615±1
656-3
❮ "V"
With guard grille for full nozzle
6,5
520±1
534
View X
66±3
112
t±3
❮ "V"
10
S4D
S6D
S8D
S4E
S6E
S8E
500-CM01 -03
500-CJ01 -03
500-CJ05 -03
500-CM03 -01
500-CJ03 -01
500-CJ03 -01
Internal diameter of the
wall ring at least 503 mm
General information
126
7
500-AM01 -03
500-AJ01 -03
500-AJ05 -03
500-AM03 -01
500-AJ03 -01
500-AJ03 -01
v
13.8
84.0
11.8
64.0
11.8
64.0
13.8
84.0
11.8
64.0
11.8
64.0
565
8,5
S4D
S6D
S8D
S4E
S6E
S8E
Mass
[kg]
AC axial fans
Type
With guard grille for short nozzle
AC centrifugal, backward
Internal diameter of the
wall ring at least 503 mm
53
v±3
11
Representatives
Electrical connections
Accessories
AC centrifugal, forward
❮ "V"
AC axial fans - HyBlade®
Ø 500, drawings for direction of air flow "A"
Type
Without attachments
A4D
A6D
A8D
A4E
A6E
A8E
133
g
10.5
209.5
8.5
189.5
8.5
189.5
10.5
209.5
8.5
189.5
8.5
189.5
497±2
99x99
115±0,3
112
500-AM01 -04
500-AJ01 -04
500-AJ05 -04
500-AM03 -02
500-AJ03 -02
500-AJ03 -02
Mass
[kg]
Internal diameter of the
wall ring at least 503 mm
65,5
4xM6
g±2
Depth of screw
max. 12 mm
Screwed cable gland
"A" ❯
With full square nozzle
211±5
Mass
[kg]
W4D 500-DM01 -04
W6D 500-DJ01 -04
W8D 500-DJ05 -04
W4E 500-DM03 -02
W6E 500-DJ03 -02
W8E 500-DJ03 -02
18.7
Type
Mass
[kg]
t
13.4
119.0
11.4
99.0
16.7
16.7
18.7
16.7
16.7
Ø11
517
91
Type
615±1
656-3
16
120
"A" ❯
With guard grille for full nozzle
91
8,5
500-BM01 -04
500-BJ01 -04
500-BJ05 -04
500-BM03 -02
500-BJ03 -02
500-BJ03 -02
11.4
99.0
13.4
119.0
11.4
99.0
11.4
99.0
630
7
S4D
S6D
S8D
S4E
S6E
S8E
Internal diameter of the
wall ring at least 503 mm
108
t±3
"A" ❯
12
General information
565
8,5
v
13.6
69.0
11.6
49.0
11.6
49.0
13.6
69.0
11.6
49.0
11.6
49.0
Internal diameter of the
wall ring at least 503 mm
AC centrifugal, backward
7
500-AM01 -04
500-AJ01 -04
500-AJ05 -04
500-AM03 -02
500-AJ03 -02
500-AJ03 -02
59
v±3
Electrical connections
Accessories
AC centrifugal, forward
"A" ❯
13
Representatives
141
S4D
S6D
S8D
S4E
S6E
S8E
Mass
[kg]
AC axial fans
Type
With guard grille for short nozzle
AC axial fans - HyBlade®
Ø 560
E
F
G
*6D 560
M6D 110-EF
-5°
Electr. connection
-10°
Perm. amp. temp.
D
M4D 110-IA
Max. operative range
B
C
*4D 560
Capacitor
A
-10°
Max. current draw (1)
M4D 110-GF
Max. power input (1)
*4D 560
Speed (1)
Motor
Frequency
Type
Nominal voltage
Nominal data
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 126
3~ 480 Y
3~ 400 Y
3~ 230 Δ
3~ 480 Y
3~ 400 Y
3~ 230 Δ
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
60
60
60
60
60
60
1580
1500
1500
1640
1575
1575
1040
970
970
1.17
1.05
1.05
1.42
1.32
1.32
0.60
0.55
0.55
1.83
1.80
3.12
2.54
2.46
4.26
0.96
0.99
1.71
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise,
direction of air flow "A" clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
H
I
—
—
—
—
—
—
—
—
—
2
[Pa]
[in H O]
Curves
140
0,5
3
120
F1b)/F2b)
F1b)/F2b)
2
2
0,3
80
B
C
0,2
60
1
1
0,1
40
20
1000
2000
2000
3000
4000
4000
6000
5000
8000
6000
[CFM]
10000
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
1
1625
0.98
1.53
78
A
2
1605
1.07
1.62
77
A
3
1580
1.17
1.83
78
B
1
1555
0.91
1.54
77
B
2
1525
0.98
1.65
76
B
3
1500
1.05
1.80
77
C
1
1555
0.91
2.68
77
C
2
1525
0.98
2.87
76
C
3
1500
1.05
3.12
77
0,4
A
14
F1b)/F2b)
A
3
0
-40 to +60
-40 to +60
-40 to +60
-40 to +65
-40 to +65
-40 to +65
-40 to +55
-40 to +55
-40 to +55
(1) Nominal data in operating point 3 with maximum load
subject to alterations
100
130
120
120
230
215
215
110
95
95
General information
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
"A" ❯
"A" ❯
With guard grille for
full nozzle
With guard grille
for short nozzle
"V"
"A"
A4D 560-AO01 -03
A4D 560-AO01 -04
W4D 560-GO01 -03
W4D 560-DO01 -04
S4D 560-CO01 -03
—
S4D 560-AO01 -03
—
—
S4D 560-BO01 -04
—
S4D 560-AO01 -04
"V"
"A"
A4D 560-AR03 -03
A4D 560-AR03 -04
W4D 560-GR03 -03
W4D 560-DR03 -04
S4D 560-CR03 -03
—
S4D 560-AR03 -03
—
—
S4D 560-BR03 -04
—
S4D 560-AR03 -04
"V"
"A"
A6D 560-AK01 -03
A6D 560-AK01 -04
W6D 560-GK01 -03
W6D 560-DK01 -04
S6D 560-CK01 -03
—
S6D 560-AK01 -03
—
—
S6D 560-BK01 -04
—
S6D 560-AK01 -04
2
3
0,9
240
[in H O]
[Pa]
Curves
D
160
0,6
2
0,4
3
G
3
1
1
2
40
1
1
0,1
H
I
0
1000
2000
2000
4000
3000
4000
6000
5000
8000
6000
10000
7000
[CFM]
12000
[m3/h]
LwA
[dB(A)]
1675
1.18
2.18
79
2
1660
1.30
2.30
79
D
3
1640
1.42
2.54
81
E
1
1625
1.09
2.02
78
E
2
1605
1.19
2.16
78
E
3
1575
1.32
2.46
80
F
1
1625
1.09
3.51
78
F
2
1605
1.19
3.76
78
F
3
1575
1.32
4.26
80
G
1
1075
0.51
0.83
68
G
2
1055
0.56
0.88
68
G
3
1040
0.60
0.96
71
H
1
1020
0.46
0.82
66
H
2
995
0.50
0.88
66
H
3
970
0.55
0.99
68
I
1
1020
0.46
1.43
66
I
2
995
0.50
1.53
66
I
3
970
0.55
1.71
68
0,2
E
F
I
[A]
1
2
0,3
80
P1
[kW]
D
2
0,5
120
n
[rpm]
D
0,7
200
0,8
3
AC centrifugal, backward
❮ "V"
With guard grille
for short nozzle
AC centrifugal, forward
❮ "V"
With guard grille for
full nozzle
Accessories
❮ "V"/ "A" ❯
With full square
nozzle
Electrical connections
❮ "V"/ "A" ❯
Without attachments
15
Drawings
p. 18 f.
Motor protection
p. 122 f.
Electr. connections
p. 126
Representatives
Direction of air flow
AC axial fans
–
–
–
–
–
AC axial fans - HyBlade®
Ø 560
Nominal voltage
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Max. operative range
Perm. amp. temp.
Electr. connection
Nominal data
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 126
1~ 230
60
1030
0.46
2.10
8.0/450
95
-40 to +55
A2b)
1~ 230
60
1010
0.57
2.48
10.0/400
95
-40 to +55
A2b)
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise,
direction of air flow "A" clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Type
Motor
*6E 560
M6E 110-EF
-10°
A
*6E 560
M6E 110-GF
-5°
B
(1) Nominal data in operating point 3 with maximum load
subject to alterations
2
[Pa]
[in H O]
Curves
100
0,40
110
0,32
70
0,20
40
20
0,08
10
0,04
30
2
1
0,12
50
0,16
60
A
0,24
80
0,28
0,36
3
90
0
500
1000
16
1000
2000
1500
2000
3000
2500
4000
3000
5000
3500
6000
4000
7000
[CFM]
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1085
0.40
1.75
67
A
2
1055
0.43
1.88
69
A
3
1030
0.46
2.10
69
General information
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
❮ "V"
❮ "V"
"A" ❯
"A" ❯
With guard grille
for full nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
"V"
"A"
A6E 560-AL01 -01
A6E 560-AL01 -02
W6E 560-GL01 -01
W6E 560-DL01 -02
S6E 560-CL01 -01
—
S6E 560-AL01 -01
—
—
S6E 560-BL01 -02
—
S6E 560-AL01 -02
"V"
"A"
A6E 560-AN01 -01
A6E 560-AN01 -02
W6E 560-GN01 -01
W6E 560-DN01 -02
S6E 560-CN01 -01
—
S6E 560-AN01 -01
—
—
S6E 560-BN01 -02
—
S6E 560-AN01 -02
2
[in H O]
[Pa]
Curves
100
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
B
1
1065
0.51
2.20
68
B
2
1040
0.54
2.33
67
B
3
1010
0.57
2.48
69
0,40
110
AC centrifugal, backward
❮ "V"/ "A" ❯
With full square
nozzle
AC centrifugal, forward
❮ "V"/ "A" ❯
Without attachments
Accessories
Direction of air flow
AC axial fans
–
–
–
–
–
0,36
3
90
20
0,08
10
0,04
Electrical connections
30
1
0,12
40
0
1000
2000
2000
3000
4000
4000
6000
5000
8000
[CFM]
[m3/h]
17
Drawings
p. 18 f.
Motor protection
p. 122 f.
Electr. connections
p. 126
Representatives
0,32
0,24
50
2
0,16
60
0,20
70
0,28
B
80
AC axial fans - HyBlade®
Ø 560, drawings for direction of air flow "V"
Type
Without attachments
A4D
A4D
A6D
A6E
A6E
-03
-03
-03
-01
-01
c
d
g
12.3
102.0
95.0
209.5
13.8
102.0
95.0
224.5
10.3
114.0 115.0
189.5
10.3
102.0
95.0
189.5
12.3
114.0 115.0
209.5
552±2
99x99
115±0,3
d±2
c±3
560-AO01
560-AR03
560-AK01
560-AL01
560-AN01
Mass
[kg]
65,5
g±2
4xM6
Depth of screw
max. 12 mm
Screwed cable gland
Internal diameter of the
wall ring at least 559 mm
❮ "V"
Type
With full square nozzle
Mass
[kg]
W4D 560-GO01
W4D 560-GR03
W6D 560-GK01
W6E 560-GL01
W6E 560-GN01
24.1
25.6
22.1
22.1
24.1
Ø11
625
161±5
-03
-03
-03
-01
-01
16
125
675±1
725-3
❮ "V"
Type
With guard grille for full nozzle
6,5
560-CO01
560-CR03
560-CK01
560-CL01
560-CN01
-03
-03
-03
-01
-01
s
t
15.1
123.0
165.0
16.6
123.0
180.0
13.1
135.0
145.0
13.1
123.0
145.0
15.1
135.0
165.0
579±1
593
View X
S4D
S4D
S6D
S6E
S6E
Mass
[kg]
65,5±3
s±4
t±3
❮ "V"
18
Internal diameter of the
wall ring at least 559 mm
General information
101,5
8,5
560-AO01
560-AR03
560-AK01
560-AL01
560-AN01
-03
-03
-03
-01
-01
u
v
16.5
66.0
108.0
18.0
66.0
123.0
14.5
78.0
88.0
14.5
66.0
88.0
16.5
78.0
108.0
AC centrifugal, backward
700
7
S4D
S4D
S6D
S6E
S6E
Mass
[kg]
AC axial fans
Type
With guard grille for short nozzle
Internal diameter of the
wall ring at least 559 mm
v±3
Electrical connections
Accessories
AC centrifugal, forward
❮ "V"
19
Representatives
u±4
AC axial fans - HyBlade®
Ø 560, drawings for direction of air flow "A"
Type
Without attachments
A4D
A4D
A6D
A6E
A6E
-04
-04
-04
-02
-02
c
d
g
12.3
127.0
95.0
209.5
13.8
127.0
95.0
224.5
10.3
136.0 115.0
189.5
10.3
127.0
95.0
189.5
12.3
136.0 115.0
209.5
552±2
99x99
115±0,3
c±3
d±2
560-AO01
560-AR03
560-AK01
560-AL01
560-AN01
Mass
[kg]
65,5
g±2
4xM6
Internal diameter of the
wall ring at least 559 mm
Depth of screw
max. 12 mm
Screwed cable gland
"A" ❯
Type
With full square nozzle
Mass
[kg]
W4D 560-DO01
W4D 560-DR03
W6D 560-DK01
W6E 560-DL01
W6E 560-DN01
213±5
25.2
26.7
23.2
23.2
25.2
Ø11
576
78
-04
-04
-04
-02
-02
16
135
675±1
725-3
"A" ❯
Type
With guard grille for full nozzle
78
7
560-BO01
560-BR03
560-BK01
560-BL01
560-BN01
-04
-04
-04
-02
-02
s
t
16.2
114.0
131.5
17.7
114.0
146.5
14.2
124.0
111.5
14.2
114.0
111.5
16.2
124.0
131.5
700
8,5
S4D
S4D
S6D
S6E
S6E
Mass
[kg]
s±4
t±3
"A" ❯
20
Internal diameter of the
wall ring at least 559 mm
General information
163,5
8,5
560-AO01
560-AR03
560-AK01
560-AL01
560-AN01
-04
-04
-04
-02
-02
u
v
17.4
29.0
46.0
18.9
29.0
61.0
15.4
38.0
26.0
15.4
29.0
26.0
17.4
38.0
46.0
v±3
Internal diameter of the
wall ring at least 559 mm
Electrical connections
Accessories
AC centrifugal, forward
"A" ❯
21
Representatives
u±4
AC centrifugal, backward
700
7
S4D
S4D
S6D
S6E
S6E
Mass
[kg]
AC axial fans
Type
With guard grille for short nozzle
AC axial fans - HyBlade®
Ø 630
Max. operative range
Perm. amp. temp.
Electr. connection
-10°
B
C
D
M4D 138-NA
Capacitor
A
*4D 630
Max. current draw (1)
M4D 138-LA
Max. power input (1)
*4D 630
Speed (1)
Motor
Frequency
Type
Nominal voltage
Nominal data
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 126
3~ 480 Y
3~ 400 Y
3~ 230 Δ
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
60
60
60
1650
1585
1585
1610
1520
1520
2.91
2.67
2.67
3.30
2.96
2.96
4.91
4.92
8.52
5.48
5.49
9.50
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" clockwise,
direction of air flow "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
-5°
E
F
—
—
—
—
—
—
2
[Pa]
[in H O]
Curves
3
3
A
300
F1b)/F2b)
F1b)/F2b)
1,0
2
200
1
0,5
1
100
B
C
2000
4000
4000
6000
8000
8000
12000
10000
16000
[CFM]
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1695
2.32
4.27
81
A
2
1680
2.66
4.64
84
A
3
1650
2.91
4.91
88
B
1
1640
2.16
4.10
80
B
2
1610
2.44
4.56
82
B
3
1585
2.67
4.92
87
C
1
1640
2.16
7.10
80
C
2
1610
2.44
7.90
82
C
3
1585
2.67
8.52
87
2
22
-40 to +60
-40 to +60
-40 to +60
-40 to +60
-40 to +60
-40 to +60
(1) Nominal data in operating point 3 with maximum load
subject to alterations
0
350
325
325
250
225
225
General information
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
❮ "V"
"A" ❯
With guard grille
for short nozzle
With guard grille
for full nozzle
"A" ❯
With guard grille
for short nozzle
"V"
"A"
A4D 630-AF03 -03
A4D 630-AF03 -04
W4D 630-GF03 -03
W4D 630-DF03 -04
S4D 630-CF03 -03
—
S4D 630-AF03 -03
—
—
S4D 630-BF03 -04
—
—
"V"
"A"
A4D 630-AB03 -03
A4D 630-AB03 -04
W4D 630-GB03 -03
W4D 630-DB03 -04
S4D 630-CB03 -03
—
S4D 630-AB03 -03
—
—
S4D 630-BB03 -04
—
—
2
[in H O]
[Pa]
Curves
3
240
0,9
3
0,8
2
0,7
200
D
2
P1
[kW]
I
[A]
LwA
[dB(A)]
D
1
1645
2.86
4.89
81
D
2
1630
3.08
5.15
80
D
3
1610
3.30
5.48
82
E
1
1575
2.61
4.89
79
E
2
1550
2.79
5.17
79
E
3
1520
2.96
5.49
80
F
1
1575
2.61
8.50
79
F
2
1550
2.79
8.99
79
F
3
1520
2.96
9.50
80
E
F
0,4
120
n
[rpm]
0,5
0,6
160
AC centrifugal, backward
❮ "V"
With guard grille
for full nozzle
AC centrifugal, forward
❮ "V"/ "A" ❯
With full square
nozzle
Accessories
❮ "V"/ "A" ❯
Without attachments
Electrical connections
Direction of air flow
AC axial fans
–
–
–
–
–
1
0,2
80
0,3
1
0
2000
4000
4000
6000
8000
8000
12000
10000
16000
[CFM]
20000 [m /h]
3
23
Drawings
p. 24 f.
Motor protection
p. 122 f.
Electr. connections
p. 126
Representatives
0,1
40
AC axial fans - HyBlade®
Ø 630, drawings for direction of air flow "V"
Without attachments
Mass
[kg]
c
A4D 630-AF03 -03
A4D 630-AB03 -03
22.3
144.0
116.0 277.0
25.3
150.0
131.0 297.0
d
162±0,3
627±2
99x99
c±3
d±2
Type
Internal diameter of the
wall ring at least 634 mm
76
8xM10
Depth of screw
max. 18 mm
g±2
Screwed cable gland
❮ "V"
With full square nozzle
Type
Mass
[kg]
W4D 630-GF03 -03
W4D 630-GB03 -03
38.2
Type
Mass
[kg]
s
t
S4D 630-CF03 -03
S4D 630-CB03 -03
27.6
131.0
188.0
30.6
137.0
207.5
41.2
Ø11
Ø696
229±5
750±1
805-3
20
150
❮ "V"
68
15,5
26
View X
10±0,5
7,5
With guard grille for full nozzle
Ø655
Ø699
92
89±3
s±4
t±3
❮ "V"
24
Internal diameter of the
wall ring at least 634 mm
g
General information
With guard grille for short nozzle
Type
Mass
[kg]
u
v
S4D 630-AF03 -03
S4D 630-AB03 -03
28.5
78.0
134.0
31.5
83.0
154.0
AC axial fans
Ø750
Ø720
u±4
10
v±3
Electrical connections
Accessories
AC centrifugal, forward
❮ "V"
25
Representatives
4
143±3
AC centrifugal, backward
Internal diameter of the
wall ring at least 634 mm
AC axial fans - HyBlade®
Ø 630, drawings for direction of air flow "A"
Without attachments
Mass
[kg]
c
A4D 630-AF03 -04
A4D 630-AB03 -04
22.3
162.0
116.0 277.0
25.3
173.0
131.0 297.0
d
162±0,3
627±2
99x99
c±3
d±2
Type
Internal diameter of the
wall ring at least 634 mm
76
g±2
8xM10
Depth of screw
max. 18 mm
Screwed cable gland
"A" ❯
With full square nozzle
Mass
[kg]
W4D 630-DF03 -04
W4D 630-DB03 -04
39.3
Type
Mass
[kg]
s
t
S4D 630-BF03 -04
S4D 630-BB03 -04
28.2
114.0
152.0
31.2
124.0
172.0
42.3
Ø11
Ø696
275±5
Type
750±1
805-3
20
150
"A" ❯
With guard grille for full nozzle
Ø750
s±4
Ø720
4
Internal diameter of the
wall ring at least 634 mm
125±3
t±3
"A" ❯
26
10
g
Representatives
27
Electrical connections
Accessories
AC centrifugal, forward
AC centrifugal, backward
AC axial fans
General information
AC axial fans - HyBlade®
Ø 630
E
F
G
-5°
H
I
J
*8D 630
M8D 110-GF
Electr. connection
D
-10°
M6D 110-IA
Perm. amp. temp.
B
C
*6D 630
Max. operative range
-5°
M6D 110-GF
Capacitor
A
*6D 630
Max. current draw (1)
M6D 110-GF
Max. power input (1)
*6D 630
Speed (1)
Motor
Frequency
Type
Nominal voltage
Nominal data
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 126
3~ 480 Y
3~ 400 Y
3~ 230 Δ
3~ 480 Y
3~ 400 Y
3~ 230 Δ
3~ 480 Y
3~ 400 Y
3~ 230 Δ
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
60
60
60
60
60
60
60
60
60
1065
1005
1005
1090
1040
1040
1040
975
975
770
710
710
0.89
0.79
0.79
0.80
0.73
0.73
0.98
0.87
0.87
0.50
0.43
0.43
1.60
1.53
2.65
1.42
1.38
2.39
1.61
1.62
2.80
0.94
0.89
1.54
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise,
direction of air flow "A" clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
-5°
K
L
—
—
—
—
—
—
—
—
—
—
—
—
140
3
0,5
3
D
0,4
120
2
2
80
0,3
3
F1b)/F2b)
F1b)/F2b)
F1b)/F2b)
0,2
1
1
2
0,1
1
1
20
B
C
1000
2000
2000
4000
3000
4000
6000
5000
8000
6000
10000
P1
[kW]
I
[A]
LwA
[dB(A)]
1
1090
0.77
1.41
71
2
1080
0.82
1.46
69
A
3
1065
0.89
1.60
69
B
1
1045
0.69
1.32
70
B
2
1025
0.75
1.38
68
B
3
1005
0.79
1.53
68
C
1
1045
0.69
2.30
70
C
2
1025
0.75
2.40
68
C
3
1005
0.79
2.65
68
D
1
1120
0.63
1.29
71
D
2
1105
0.72
1.36
70
D
3
1090
0.80
1.42
72
E
1
1085
0.58
1.16
71
E
2
1065
0.65
1.27
69
E
3
1040
0.73
1.38
71
F
1
1085
0.58
2.02
71
F
2
1065
0.65
2.21
69
F
3
1040
0.73
2.39
71
2
40
E
F
n
[rpm]
A
A
3
60
28
F1b)/F2b)
A
2
[Pa]
[in H O]
Curves
0
-40 to +55
-40 to +55
-40 to +55
-40 to +55
-40 to +55
-40 to +55
-40 to +55
-40 to +55
-40 to +55
-40 to +55
-40 to +55
-40 to +55
(1) Nominal data in operating point 3 with maximum load
subject to alterations
100
80
70
70
140
128
128
150
130
130
80
70
70
7000
[CFM]
12000
[m3/h]
General information
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
"A" ❯
"A" ❯
With guard grille
for full nozzle
With guard grille
for short nozzle
"V"
"A"
A6D 630-AN05 -03
A6D 630-AN05 -04
W6D 630-GN05 -03
W6D 630-DN05 -04
S6D 630-CN05 -03
—
S6D 630-AN05 -03
—
—
S6D 630-BN05 -04
—
S6D 630-AN05 -04
"V"
"A"
A6D 630-AO05 -03
A6D 630-AO05 -04
W6D 630-GO05 -03
W6D 630-DO05 -04
S6D 630-CO05 -03
—
S6D 630-AO05 -03
—
—
S6D 630-BO05 -04
—
S6D 630-AO05 -04
"V"
"A"
A6D 630-AQ07 -03
A6D 630-AQ07 -04
W6D 630-GQ07 -03
W6D 630-DQ07 -04
S6D 630-CQ07 -03
—
S6D 630-AQ07 -03
—
—
S6D 630-BQ07 -04
—
S6D 630-AQ07 -04
"V"
"A"
A8D 630-AN05 -03
A8D 630-AN05 -04
W8D 630-GN05 -03
W8D 630-DN05 -04
S8D 630-CN05 -03
—
S8D 630-AN05 -03
—
—
S8D 630-BN05 -04
—
S8D 630-AN05 -04
2
[in H O]
[Pa]
Curves
0,6
160
3
140
G
100
0,4
120
0,5
3
2
2
80
0,3
3
J
3
60
1
0,2
2
1
2
40
0,1
20
K
L
0
1000
2000
2000
4000
3000
4000
6000
H
I
1
1
5000
8000
6000
10000
7000
[CFM]
12000
[m3/h]
AC centrifugal, backward
❮ "V"
With guard grille
for short nozzle
AC centrifugal, forward
❮ "V"
With guard grille
for full nozzle
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
G
1
1080
0.80
1.33
69
G
2
1065
0.88
1.43
69
G
3
1040
0.98
1.61
71
H
1
1025
0.73
1.31
68
H
2
1000
0.80
1.43
68
H
3
975
0.87
1.62
70
I
1
1025
0.73
2.28
68
I
2
1000
0.80
2.49
68
I
3
975
0.87
2.80
70
J
1
800
0.42
0.87
64
J
2
785
0.46
0.89
63
J
3
770
0.50
0.94
64
K
1
755
0.36
0.78
62
K
2
735
0.39
0.83
61
K
3
710
0.43
0.89
63
L
1
755
0.36
1.36
62
L
2
735
0.39
1.44
61
L
3
710
0.43
1.54
63
Accessories
❮ "V"/ "A" ❯
With full square
nozzle
Electrical connections
❮ "V"/ "A" ❯
Without attachments
29
Drawings
p. 32 f.
Motor protection
p. 122 f.
Electr. connections
p. 126
Representatives
Direction of air flow
AC axial fans
–
–
–
–
–
AC axial fans - HyBlade®
Ø 630
-5°
B
Electr. connection
M8E 110-GF
Perm. amp. temp.
*8E 630
Max. operative range
A
Capacitor
-10°
Max. current draw (1)
M6E 110-GF
Max. power input (1)
*6E 630
Speed (1)
Motor
Frequency
Type
Nominal voltage
Nominal data
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise,
direction of air flow "A" clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 126
1~ 230
60
920
0.69
3.02
12.0/450
110
-40 to +40
A2b)
1~ 230
60
710
0.46
2.12
7.0/450
75
-40 to +55
A2b)
(1) Nominal data in operating point 3 with maximum load
subject to alterations
2
[Pa]
[in H O]
Curves
110
0,40
100
3
0,36
80
0,32
A
90
0,24
0,20
40
20
0,08
10
0,04
30
1
0,12
50
0,16
60
0,28
2
70
0
1000
2000
30
2000
4000
3000
4000
6000
5000
8000
6000
[CFM]
10000
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1060
0.59
2.59
72
A
2
1015
0.64
2.79
68
A
3
920
0.69
3.02
69
General information
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
❮ "V"
❮ "V"
"A" ❯
"A" ❯
With guard grille
for full nozzle
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
"V"
"A"
A6E 630-AO01 -01
A6E 630-AO01 -02
W6E 630-GO01 -01
W6E 630-DO01 -02
S6E 630-CO01 -01
—
S6E 630-AO01 -01
—
—
S6E 630-BO01 -02
—
S6E 630-AO01 -02
"V"
"A"
A8E 630-AN01 -01
A8E 630-AN01 -02
W8E 630-GN01 -01
W8E 630-DN01 -02
S8E 630-CN01 -01
—
S8E 630-AN01 -01
—
—
S8E 630-BN01 -02
—
S8E 630-AN01 -02
70
2
[in H O]
3
0,28
[Pa]
Curves
AC centrifugal, backward
❮ "V"/ "A" ❯
With full square
nozzle
AC centrifugal, forward
❮ "V"/ "A" ❯
Without attachments
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
B
1
780
0.42
1.88
63
B
2
750
0.44
2.01
62
B
3
710
0.46
2.12
64
Accessories
Direction of air flow
AC axial fans
–
–
–
–
–
60
0,24
B
0
Electrical connections
10
1
1000
2000
2000
3000
4000
4000
6000
5000
8000
[CFM]
[m3/h]
31
Drawings
p. 32 f.
Motor protection
p. 122 f.
Electr. connections
p. 126
Representatives
0,16
20
0,08
30
0,04
40
0,12
0,20
2
50
AC axial fans - HyBlade®
Ø 630, drawings for direction of air flow "V"
Type
Without attachments
A6D
A6D
A6D
A8D
A6E
A8E
630-AN05
630-AO05
630-AQ07
630-AN05
630-AO01
630-AN01
-03
-03
-03
-03
-01
-01
c
d
119.0 121.0
209.5
12.5
105.0
98.0
209.5
14.0
119.0 121.0
224.5
12.5
119.0 121.0
209.5
12.5
105.0
98.0
209.5
12.5
119.0 121.0
209.5
65,5
g±2
4xM6
Depth of screw
max. 12 mm
Screwed cable gland
Internal diameter of the
wall ring at least 634 mm
❮ "V"
Type
With full square nozzle
Mass
[kg]
W6D 630-GN05
W6D 630-GO05
W6D 630-GQ07
W8D 630-GN05
W6E 630-GO01
W8E 630-GN01
27.4
27.4
28.9
27.4
27.4
27.4
Ø11
726
206±5
-03
-03
-03
-03
-01
-01
20
142
750±1
805-3
❮ "V"
Type
With guard grille for full nozzle
6,5
630-CN05
630-CO05
630-CQ07
630-CN05
630-CO01
630-CN01
-03
-03
-03
-03
-01
-01
Mass
[kg]
s
t
16.0
132.0
157.0
16.0
118.0
157.0
17.5
132.0
172.0
16.0
132.0
157.0
16.0
118.0
157.0
16.0
132.0
157.0
655±1
669
View X
S6D
S6D
S6D
S8D
S6E
S8E
52,5±3
s±4
t±3
❮ "V"
32
g
12.5
627±2
99x99
115±0,3
d±2
c±3
Mass
[kg]
Internal diameter of the
wall ring at least 634 mm
General information
123,5
8,5
630-AN05
630-AO05
630-AQ07
630-AN05
630-AO01
630-AN01
-03
-03
-03
-03
-01
-01
u
v
17.7
61.0
86.0
17.7
47.0
86.0
19.2
61.0
101.0
17.7
61.0
86.0
17.7
47.0
86.0
17.7
61.0
86.0
AC centrifugal, backward
750
7
S6D
S6D
S6D
S8D
S6E
S8E
Mass
[kg]
AC axial fans
Type
With guard grille for short nozzle
Internal diameter of the
wall ring at least 634 mm
v±3
Electrical connections
Accessories
AC centrifugal, forward
❮ "V"
33
Representatives
u±4
AC axial fans - HyBlade®
Ø 630, drawings for direction of air flow "A"
Type
Without attachments
A6D
A6D
A6D
A8D
A6E
A8E
630-AN05
630-AO05
630-AQ07
630-AN05
630-AO01
630-AN01
-04
-04
-04
-04
-02
-02
c
d
136.0 121.0
209.5
12.5
127.0
98.0
209.5
14.0
136.0 121.0
224.5
12.5
136.0 121.0
209.5
12.5
127.0
98.0
209.5
12.5
136.0 121.0
209.5
65,5
g±2
4xM6
Internal diameter of the
wall ring at least 634 mm
Depth of screw
max. 12 mm
Screwed cable gland
"A" ❯
Type
With full square nozzle
Mass
[kg]
W6D 630-DN05
W6D 630-DO05
W6D 630-DQ07
W8D 630-DN05
W6E 630-DO01
W8E 630-DN01
228±5
28.2
28.2
29.7
28.2
28.2
28.2
Ø11
653
78
-04
-04
-04
-04
-02
-02
20
150
750±1
805-3
"A" ❯
Type
With guard grille for full nozzle
78
7
630-BN05
630-BO05
630-BQ07
630-BN05
630-BO01
630-BN01
-04
-04
-04
-04
-02
-02
Mass
[kg]
s
t
17.1
123.0
131.5
17.1
114.0
131.5
18.6
123.0
146.5
17.1
123.0
131.5
17.1
114.0
131.5
17.1
123.0
131.5
750
8,5
S6D
S6D
S6D
S8D
S6E
S8E
s±4
t±3
"A" ❯
34
g
12.5
627±2
99x99
115±0,3
c±3
d±2
Mass
[kg]
Internal diameter of the
wall ring at least 634 mm
General information
141
8,5
630-AN05
630-AO05
630-AQ07
630-AN05
630-AO01
630-AN01
-04
-04
-04
-04
-02
-02
u
v
18.1
61.0
68.5
18.1
42.0
68.5
19.6
61.0
83.5
18.1
61.0
68.5
16.1
42.0
68.5
18.1
61.0
68.5
v±3
Internal diameter of the
wall ring at least 634 mm
Electrical connections
Accessories
AC centrifugal, forward
"A" ❯
35
Representatives
u±4
AC centrifugal, backward
750
7
S6D
S6D
S6D
S8D
S6E
S8E
Mass
[kg]
AC axial fans
Type
With guard grille for short nozzle
AC axial fans - HyBlade®
Ø 710
Max. current draw (1)
Capacitor
Max. operative range
Perm. amp. temp.
Electr. connection
M6D 138-HF
Max. power input (1)
*6D 710
Speed (1)
Motor
Frequency
Type
Nominal voltage
Nominal data
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 126
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
1070
1015
1015
1.64
1.48
1.48
2.88
2.90
5.00
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" clockwise,
direction of air flow "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
A
-5°
B
C
—
—
—
2
0,8 [in H O]
Curves
[Pa]
-40 to +60
-40 to +60
-40 to +60
F1b)/F2b)
(1) Nominal data in operating point 3 with maximum load
subject to alterations
200
175
160
160
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1090
1.45
2.69
76
A
2
1080
1.55
2.80
80
A
3
1070
1.64
2.88
82
B
1
1050
1.31
2.62
75
B
2
1030
1.41
2.79
79
B
3
1015
1.48
2.90
81
C
1
1050
1.31
4.54
75
C
2
1030
1.41
4.83
79
C
3
1015
1.48
5.00
81
3
3
160
0,6
2
2
120
0,4
1
1
A
80
0,2
B
C
40
0
2000
4000
36
4000
6000
8000
8000
12000
10000
16000
[CFM]
[m3/h]
General information
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
W6D 710-GH03 -03
W6D 710-DH03 -04
"A" ❯
With guard grille
for full nozzle
S6D 710-CH03 -03
—
S6D 710-AH03 -03
—
—
S6D 710-BH03 -04
AC centrifugal, backward
❮ "V"
With guard grille
for short nozzle
"A" ❯
With guard grille
for short nozzle
—
—
AC centrifugal, forward
A6D 710-AH03 -03
A6D 710-AH03 -04
❮ "V"
With guard grille
for full nozzle
Accessories
"V"
"A"
❮ "V"/ "A" ❯
With full square
nozzle
Electrical connections
❮ "V"/ "A" ❯
Without attachments
37
Drawings
p. 38 f.
Motor protection
p. 122 f.
Electr. connections
p. 126
Representatives
Direction of air flow
AC axial fans
–
–
–
–
–
AC axial fans - HyBlade®
Ø 710, drawings for direction of air flow "V"
Without attachments
Type
Mass
[kg]
c
A6D 710-AH03 -03
18.8
148.0
d
162±0,3
703±2
99x99
c±3
d±2
Internal diameter of the
wall ring at least 710 mm
76
8xM10
Depth of screw
max. 18 mm
g±2
Screwed cable gland
❮ "V"
With full square nozzle
Type
Mass
[kg]
W6D 710-GH03 -03
36.7
Type
Mass
[kg]
s
t
S6D 710-CH03 -03
25.0
124.0
152.0
Ø14,5
Ø772
261±5
810±1
850-3
20
170
❮ "V"
68
15,5
26
View X
10±0,5
7,5
With guard grille for full nozzle
Ø733
Ø777
92
100±3
s±4
t±3
❮ "V"
38
Internal diameter of the
wall ring at least 710 mm
g
126.0 252.0
General information
With guard grille for short nozzle
Type
Mass
[kg]
u
v
S6D 710-AH03 -03
26.6
37.0
66.0
AC axial fans
Ø853
Ø821
u±4
10
v±3
Electrical connections
Accessories
AC centrifugal, forward
❮ "V"
39
Representatives
4
187±3
AC centrifugal, backward
Internal diameter of the
wall ring at least 710 mm
AC axial fans - HyBlade®
Ø 710, drawings for direction of air flow "A"
Without attachments
Type
Mass
[kg]
c
A6D 710-AH03 -04
18.8
169.0
d
162±0,3
703±2
99x99
c±3
d±2
Internal diameter of the
wall ring at least 710 mm
76
g±2
8xM10
Depth of screw
max. 18 mm
Screwed cable gland
"A" ❯
With full square nozzle
Type
Mass
[kg]
W6D 710-DH03 -04
37.3
Type
Mass
[kg]
s
t
S6D 710-BH03 -04
25.1
148.0
156.0
Ø14,5
Ø772
267±5
20
170
810±1
850-3
"A" ❯
With guard grille for full nozzle
Ø853
s±4
Ø827
4
Internal diameter of the
wall ring at least 710 mm
97±3
t±3
"A" ❯
40
10
g
126.0 252.0
Representatives
41
Electrical connections
Accessories
AC centrifugal, forward
AC centrifugal, backward
AC axial fans
General information
AC axial fans - HyBlade®
Ø 710
Electr. connection
-5°
E
F
G
M8D 110-IA
Perm. amp. temp.
B
D
*8D 710
Max. operative range
-10°
C
M8D 110-IA
Capacitor
A
*8D 710
Max. current draw (1)
M6D 110-IA
Max. power input (1)
*6D 710
Speed (1)
Motor
Frequency
Type
Nominal voltage
Nominal data
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 126
3~ 480 Y
3~ 400 Y
3~ 230 Δ
3~ 480 Y
3~ 400 Y
3~ 230 Δ
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
60
60
60
60
60
60
1080
1030
1030
790
740
740
820
780
780
0.98
0.89
0.89
0.60
0.52
0.52
0.50
0.44
0.44
1.75
1.71
2.96
1.16
1.09
1.89
1.08
0.98
1.70
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise,
direction of air flow "A" clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
-10°
H
I
—
—
—
—
—
—
—
—
—
3
140
0,5
3
A
0,4
2
2
0,3
80
B
C
1
1
0,2
60
0,1
40
20
0
2000
2000
42
F1b)/F2b)
F1b)/F2b)
F1b)/F2b)
4000
4000
6000
6000
8000
10000
8000
12000
14000
[CFM]
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1115
0.76
1.46
77
A
2
1100
0.87
1.56
77
A
3
1080
0.98
1.75
80
B
1
1080
0.70
1.37
76
B
2
1055
0.80
1.51
76
B
3
1030
0.89
1.71
79
C
1
1080
0.70
2.38
76
C
2
1055
0.80
2.63
76
C
3
1030
0.89
2.96
79
2
[Pa]
[in H O]
Curves
100
-40 to +60
-40 to +60
-40 to +60
-40 to +60
-40 to +60
-40 to +60
-40 to +65
-40 to +65
-40 to +65
(1) Nominal data in operating point 3 with maximum load
subject to alterations
120
140
125
125
60
55
55
80
73
73
General information
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
"A" ❯
"A" ❯
With guard grille
for full nozzle
With guard grille
for short nozzle
"V"
A6D 710-AR05 -03
W6D 710-GR05 -03
S6D 710-CR05 -03
S6D 710-AR05 -03
"V"
"A"
A8D 710-AQ01 -03
A8D 710-AQ01 -04
W8D 710-GQ01 -03
W8D 710-DQ01 -04
S8D 710-CQ01 -03
—
S8D 710-AQ01 -03
—
—
S8D 710-BQ01 -04
—
S8D 710-AQ01 -04
"V"
"A"
A8D 710-AR01 -03
A8D 710-AR01 -04
W8D 710-GR01 -03
W8D 710-DR01 -04
S8D 710-CR01 -03
—
S8D 710-AR01 -03
—
—
S8D 710-BR01 -04
—
S8D 710-AR01 -04
80
2
0,32 [in H O]
[Pa]
Curves
3
60
G
0,24
70
0,28
3
3
2
20
10
0,2
0,16
0,12
30
2
H
I
0
E
F
2000
2000
4000
3000
4000
6000
P1
[kW]
I
[A]
LwA
[dB(A)]
1
825
0.48
1.08
68
D
2
810
0.53
1.12
66
D
3
790
0.60
1.16
65
E
1
785
0.42
0.96
67
E
2
765
0.47
1.01
65
E
3
740
0.52
1.09
64
F
1
785
0.42
1.67
67
F
2
765
0.47
1.76
65
F
3
740
0.52
1.89
64
G
1
840
0.40
1.01
70
G
2
830
0.46
1.05
70
G
3
820
0.50
1.08
72
H
1
815
0.35
0.87
69
H
2
800
0.39
0.93
69
H
3
780
0.44
0.98
71
I
1
815
0.35
1.51
69
I
2
800
0.39
1.62
69
I
3
780
0.44
1.70
71
1
1
1000
n
[rpm]
D
D
2
0,08
40
2
1
1
0,04
50
3
AC centrifugal, backward
❮ "V"
With guard grille
for short nozzle
AC centrifugal, forward
❮ "V"
With guard grille
for full nozzle
Accessories
❮ "V"/ "A" ❯
With full square
nozzle
Electrical connections
❮ "V"/ "A" ❯
Without attachments
5000
8000
6000
10000
7000
[CFM]
12000
[m3/h]
43
Drawings
p. 46 f.
Motor protection
p. 122 f.
Electr. connections
p. 126
Representatives
Direction of air flow
AC axial fans
–
–
–
–
–
AC axial fans - HyBlade®
Ø 710
Capacitor
Max. operative range
Perm. amp. temp.
Electr. connection
-10°
Max. current draw (1)
M8E 110-IA
Max. power input (1)
*8E 710
Speed (1)
Motor
Frequency
Type
Nominal voltage
Nominal data
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise,
direction of air flow "A" clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 126
60
775
0.46
2.14
8.0/450
70
1~ 230
A
3
2
0,2
0,16
20
0,08
30
10
0,04
40
0,12
50
0,24
A
60
0
1
1000
2000
44
2000
3000
4000
4000
6000
5000
8000
[CFM]
10000 [m /h]
3
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
820
0.39
1.80
69
A
2
800
0.43
1.98
68
A
3
775
0.46
2.14
70
2
0,32 [in H O]
0,28
[Pa]
Curves
70
A2b)
(1) Nominal data in operating point 3 with maximum load
subject to alterations
80
-40 to +65
General information
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
W8E 710-GR01 -03
W8E 710-DR01 -04
"A" ❯
AC centrifugal, backward
❮ "V"
"A" ❯
With guard grille
for short nozzle
With guard grille
for full nozzle
With guard grille
for short nozzle
S8E 710-CR01 -03
—
S8E 710-AR01 -03
—
—
S8E 710-BR01 -04
—
S8E 710-AR01 -04
AC centrifugal, forward
A8E 710-AR01 -03
A8E 710-AR01 -04
❮ "V"
With guard grille
for full nozzle
Accessories
"V"
"A"
❮ "V"/ "A" ❯
With full square
nozzle
Electrical connections
❮ "V"/ "A" ❯
Without attachments
45
Drawings
p. 46 f.
Motor protection
p. 122 f.
Electr. connections
p. 126
Representatives
Direction of air flow
AC axial fans
–
–
–
–
–
AC axial fans - HyBlade®
Ø 710, drawings for direction of air flow "V"
Type
Without attachments
A6D
A8D
A8D
A8E
-03
-03
-03
-03
c
d
14.0
111.0
96.0
14.0
118.0
113.0
14.0
111.0
96.0
14.0
111.0
96.0
703±2
99x99
115±0,3
d±2
c±3
710-AR05
710-AQ01
710-AR01
710-AR01
Mass
[kg]
Internal diameter of the
wall ring at least 710 mm
65,5
224,5±2
4xM6
Depth of screw
max. 12 mm
Screwed cable gland
❮ "V"
Type
With full square nozzle
Mass
[kg]
W6D 710-GR05
W8D 710-GQ01
W8D 710-GR01
W8E 710-GR01
29.9
29.9
29.9
29.9
Ø11
792
199±5
-03
-03
-03
-03
20
160
810±1
850-3
❮ "V"
Type
With guard grille for full nozzle
735±1
749
View X
42,5±3
s±4
182±3
❮ "V"
46
6,5
S6D
S8D
S8D
S8E
710-CR05
710-CQ01
710-CR01
710-CR01
-03
-03
-03
-03
Mass
[kg]
s
17.9
134.0
17.9
141.0
17.9
134.0
17.9
134.0
Internal diameter of the
wall ring at least 710 mm
General information
153,5
8,5
710-AR05
710-AQ01
710-AR01
710-AR01
-03
-03
-03
-03
u
20.5
22.0
20.5
29.0
20.5
22.0
20.5
22.0
853
7
S6D
S8D
S8D
S8E
Mass
[kg]
AC axial fans
Type
With guard grille for short nozzle
AC centrifugal, backward
Internal diameter of the
wall ring at least 710 mm
u±4
70±3
47
Representatives
Electrical connections
Accessories
AC centrifugal, forward
❮ "V"
AC axial fans - HyBlade®
Ø 710, drawings for direction of air flow "A"
Without attachments
Mass
[kg]
c
d
A8D 710-AQ01 -04
A8D 710-AR01 -04
A8E 710-AR01 -04
14.0
131.0
113.0
14.0
119.0
96.0
14.0
119.0
96.0
703±2
99x99
115±0,3
c±3
d±2
Type
Internal diameter of the
wall ring at least 710 mm
65,5
224,5±2
4xM6
Depth of screw
max. 12 mm
Screwed cable gland
"A" ❯
With full square nozzle
Mass
[kg]
W8D 710-DQ01 -04
W8D 710-DR01 -04
W8E 710-DR01 -04
30.8
Type
Mass
[kg]
s
S8D 710-BQ01 -04
S8D 710-BR01 -04
S8E 710-BR01 -04
18.7
152.0
18.7
140.0
18.7
140.0
30.8
30.8
Ø11
792
205±5
44,5
Type
20
160
810±1
850-3
"A" ❯
With guard grille for full nozzle
43,5
7
853
8,5
Internal diameter of the
wall ring at least 710 mm
s±4
180±3
"A" ❯
48
General information
With guard grille for short nozzle
104,5
8,5
Mass
[kg]
u
S8D 710-AQ01 -04
S8D 710-AR01 -04
S8E 710-AR01 -04
19.8
91.0
19.8
79.0
19.8
79.0
853
AC axial fans
7
Type
AC centrifugal, backward
Internal diameter of the
wall ring at least 710 mm
u±4
119±3
49
Representatives
Electrical connections
Accessories
AC centrifugal, forward
"A" ❯
AC axial fans - HyBlade®
Ø 800
Max. operative range
Perm. amp. temp.
Electr. connection
-10°
B
C
D
M6D 138-LA
Capacitor
A
*6D 800
Max. current draw (1)
M6D 138-LA
Max. power input (1)
*6D 800
Speed (1)
Motor
Frequency
Type
Nominal voltage
Nominal data
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 126
3~ 480 Y
3~ 400 Y
3~ 230 Δ
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
60
60
60
1100
1050
1050
1080
1030
1030
1.98
1.80
1.80
2.18
1.99
1.99
3.60
3.55
6.15
3.80
3.78
6.50
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" clockwise,
direction of air flow "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
-5°
E
F
—
—
—
—
—
—
2
[Pa]
[in H O]
Curves
3
0,8
0,7
160
0,6
2
0,4
0,5
2
1
0,3
1
0,2
80
40
B
C
0,1
0
2000
4000
50
F1b)/F2b)
F1b)/F2b)
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1130
1.51
3.04
77
A
2
1115
1.75
3.30
78
A
3
1100
1.98
3.60
80
B
1
1100
1.41
2.95
77
B
2
1075
1.62
3.27
77
B
3
1050
1.80
3.55
79
C
1
1100
1.41
5.13
77
C
2
1075
1.62
5.69
77
C
3
1050
1.80
6.15
79
3
A
120
-40 to +60
-40 to +60
-40 to +60
-40 to +60
-40 to +60
-40 to +60
(1) Nominal data in operating point 3 with maximum load
subject to alterations
200
220
200
200
150
135
135
4000
6000
8000
8000
12000
10000
16000
12000
20000
[CFM]
[m3/h]
General information
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
"A" ❯
With guard grille
for full nozzle
"A" ❯
With guard grille
for short nozzle
"V"
"A"
A6D 800-AF05 -03
A6D 800-AF05 -04
W6D 800-GF05 -03
W6D 800-DF05 -04
S6D 800-CF05 -03
—
S6D 800-AF05 -03
—
—
S6D 800-BF05 -04
—
—
"V"
"A"
A6D 800-AE05 -03
A6D 800-AE05 -04
W6D 800-GE05 -03
W6D 800-DE05 -04
S6D 800-CE05 -03
—
S6D 800-AE05 -03
—
—
S6D 800-BE05 -04
—
—
2
[in H O]
[Pa]
Curves
3
150
3
2
100
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
D
1
1100
1.91
3.59
75
D
2
1090
2.03
3.72
74
D
3
1080
2.18
3.80
76
E
1
1060
1.74
3.47
74
E
2
1040
1.85
3.64
73
E
3
1030
1.99
3.78
75
F
1
1060
1.74
6.01
74
F
2
1040
1.85
6.30
73
F
3
1030
1.99
6.50
75
0,5
D
AC centrifugal, backward
❮ "V"
With guard grille
for short nozzle
AC centrifugal, forward
❮ "V"
With guard grille
for full nozzle
Accessories
❮ "V"/ "A" ❯
With full square
nozzle
Electrical connections
❮ "V"/ "A" ❯
Without attachments
2
1
0,25
1
50
E
F
0
3000
4000
9000
6000
8000
12000
16000
12000
20000
[CFM]
[m3/h]
51
Drawings
p. 54 f.
Motor protection
p. 122 f.
Electr. connections
p. 126
Representatives
Direction of air flow
AC axial fans
–
–
–
–
–
AC axial fans - HyBlade®
Ø 800
Electr. connection
D
0°
E
F
G
MZD 138-HF
Perm. amp. temp.
B
C
*ZD 800
Max. operative range
-10°
M8D 138-LA
Capacitor
A
*8D 800
Max. current draw (1)
M8D 138-HF
Max. power input (1)
*8D 800
Speed (1)
Motor
Frequency
Type
Nominal voltage
Nominal data
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 126
3~ 480 Y
3~ 400 Y
3~ 230 Δ
3~ 480 Y
3~ 400 Y
3~ 230 Δ
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
60
60
60
60
60
60
800
755
755
800
750
750
510
480
480
0.87
0.76
0.76
1.27
1.12
1.12
0.52
0.43
0.43
1.95
1.70
2.94
2.47
2.40
4.15
1.20
1.10
1.90
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" clockwise,
direction of air flow "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
0°
H
I
—
—
—
—
—
—
—
—
—
2
[Pa]
[in H O]
Curves
3
0,40
3
100
0,32
2
0,24
3
0,16
0
4000
52
2
E
F
B
C
2000
4000
6000
8000
8000
12000
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
825
0.69
1.83
70
2
810
0.79
1.89
71
A
3
800
0.87
1.95
72
B
1
800
0.60
1.52
71
B
2
780
0.69
1.64
70
B
3
755
0.76
1.70
71
C
1
800
0.60
2.64
71
C
2
780
0.69
2.85
70
C
3
755
0.76
2.94
71
D
1
815
1.14
2.37
68
D
2
805
1.21
2.44
69
D
3
800
1.27
2.47
69
E
1
770
1.03
2.27
67
E
2
760
1.08
2.36
67
E
3
750
1.12
2.40
68
F
1
770
1.03
3.95
67
F
2
760
1.08
4.10
67
F
3
750
1.12
4.15
68
2
1
0,08
20
F1b)/F2b)
1
D
3
1
40
F1b)/F2b)
A
A
60
F1b)/F2b)
A
2
80
-40 to +65
-40 to +65
-40 to +65
-40 to +65
-40 to +65
-40 to +65
-40 to +65
-40 to +65
-40 to +65
(1) Nominal data in operating point 3 with maximum load
subject to alterations
120
115
105
105
65
57
57
50
44
44
10000
16000
1
1
[CFM]
[m3/h]
General information
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
"A" ❯
With guard grille
for full nozzle
"A" ❯
With guard grille
for short nozzle
"V"
"A"
A8D 800-AI09 -03
A8D 800-AI09 -04
W8D 800-GI09 -03
W8D 800-DI09 -04
S8D 800-CI09 -03
—
S8D 800-AI09 -03
—
—
S8D 800-BI09 -04
—
—
"V"
"A"
A8D 800-AD05 -03
A8D 800-AD05 -04
W8D 800-GD05 -03
W8D 800-DD05 -04
S8D 800-CD05 -03
—
S8D 800-AD05 -03
—
—
S8D 800-BD05 -04
—
—
"V"
"A"
AZD 800-AG07 -03
AZD 800-AG07 -04
WZD 800-GG07 -03
WZD 800-DG07 -04
SZD 800-CG07 -03
—
SZD 800-AG07 -03
—
—
SZD 800-BG07 -04
—
—
50
2
[in H O]
0,24
60
0,20
[Pa]
Curves
3
G
3
0,16
40
2
20
0,08
10
0,04
30
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
G
1
530
0.46
1.16
59
G
2
520
0.48
1.18
59
G
3
510
0.52
1.20
60
H
1
500
0.38
1.01
57
H
2
490
0.40
1.05
58
H
3
480
0.43
1.10
60
I
1
500
0.38
1.76
57
I
2
490
0.40
1.83
58
I
3
480
0.43
1.90
60
0,12
2
AC centrifugal, backward
❮ "V"
With guard grille
for short nozzle
AC centrifugal, forward
❮ "V"
With guard grille
for full nozzle
Accessories
❮ "V"/ "A" ❯
With full square
nozzle
Electrical connections
❮ "V"/ "A" ❯
Without attachments
H
I
0
2000
2000
4000
4000
6000
1
1
6000
8000
10000
8000
12000
14000
[CFM]
[m3/h]
53
Drawings
p. 54 f.
Motor protection
p. 122 f.
Electr. connections
p. 126
Representatives
Direction of air flow
AC axial fans
–
–
–
–
–
AC axial fans - HyBlade®
Ø 800, drawings for direction of air flow "V"
Type
Without attachments
A6D
A6D
A8D
A8D
AZD
-03
-03
-03
-03
-03
c
23.0
143.0
112.0 277.0
23.0
150.0
130.0 277.0
19.0
143.0
112.0 252.0
23.0
158.0
143.0 277.0
19.0
158.0
143.0 252.0
d
162±0,3
788±2
99x99
c±3
d±2
800-AF05
800-AE05
800-AI09
800-AD05
800-AG07
Mass
[kg]
Internal diameter of the
wall ring at least 795 mm
76
8xM10
Depth of screw
max. 18 mm
g±2
Screwed cable gland
❮ "V"
Type
With full square nozzle
Mass
[kg]
W6D 800-GF05
W6D 800-GE05
W8D 800-GI09
W8D 800-GD05
WZD 800-GG07
44.2
44.2
40.2
44.2
40.2
Ø14,5
Ø857
283±5
-03
-03
-03
-03
-03
910±1
970-3
17
190
❮ "V"
Type
68
15,5
Ø816
Ø861
92
108±3
s±4
t±3
❮ "V"
54
26
View X
15±0,5
7,5
With guard grille for full nozzle
S6D
S6D
S8D
S8D
SZD
800-CF05
800-CE05
800-CI09
800-CD05
800-CG07
-03
-03
-03
-03
-03
Mass
[kg]
s
t
29.7
111.0
169.0
29.7
118.0
169.0
25.7
111.0
144.0
29.7
127.0
169.0
25.7
127.0
144.0
Internal diameter of the
wall ring at least 795 mm
g
General information
S6D
S6D
S8D
S8D
SZD
-03
-03
-03
-03
-03
u
v
30.0
18.0
76.0
30.0
25.0
76.0
26.0
18.0
51.0
30.0
34.0
76.0
26.0
34.0
51.0
Ø960
Ø929
u±4
800-AF05
800-AE05
800-AI09
800-AD05
800-AG07
Mass
[kg]
AC axial fans
Type
With guard grille for short nozzle
10
v±3
Electrical connections
Accessories
AC centrifugal, forward
❮ "V"
55
Representatives
4
201±3
AC centrifugal, backward
Internal diameter of the
wall ring at least 795 mm
AC axial fans - HyBlade®
Ø 800, drawings for direction of air flow "A"
Type
Without attachments
A6D
A6D
A8D
A8D
AZD
-04
-04
-04
-04
-04
c
23.0
159.0
112.0 277.0
23.0
171.0
130.0 277.0
19.0
159.0
112.0 252.0
23.0
179.0
143.0 277.0
19.0
179.0
143.0 252.0
d
162±0,3
788±2
99x99
c±3
d±2
800-AF05
800-AE05
800-AI09
800-AD05
800-AG07
Mass
[kg]
Internal diameter of the
wall ring at least 795 mm
76
g±2
8xM10
Depth of screw
max. 18 mm
Screwed cable gland
"A" ❯
Type
With full square nozzle
Mass
[kg]
W6D 800-DF05
W6D 800-DE05
W8D 800-DI09
W8D 800-DD05
WZD 800-DG07
44.9
44.9
40.9
44.9
40.9
Ø14,5
Ø857
269±5
-04
-04
-04
-04
-04
17
190
910±1
970-3
"A" ❯
Type
With guard grille for full nozzle
800-BF05
800-BE05
800-BI09
800-BD05
800-BG07
-04
-04
-04
-04
-04
s
t
30.0
156.0
198.0
30.0
168.0
198.0
26.0
156.0
173.0
30.0
177.0
198.0
26.0
177.0
173.0
Ø960
s±4
Ø911
4
S6D
S6D
S8D
S8D
SZD
Mass
[kg]
Internal diameter of the
wall ring at least 795 mm
79±3
t±3
"A" ❯
56
10
g
Representatives
57
Electrical connections
Accessories
AC centrifugal, forward
AC centrifugal, backward
AC axial fans
General information
AC axial fans - HyBlade®
Ø 910
Electr. connection
D
-5°
E
F
G
M6D 138-NA
Perm. amp. temp.
B
C
*6D 910
Max. operative range
-10°
M6D 138-NA
Capacitor
A
*6D 910
Max. current draw (1)
M6D 138-LA
Max. power input (1)
*6D 910
Speed (1)
Motor
Frequency
Type
Nominal voltage
Nominal data
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 126
3~ 480 Y
3~ 400 Y
3~ 230 Δ
3~ 480 Y
3~ 400 Y
3~ 230 Δ
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
60
60
60
60
60
60
1090
1035
1035
1100
1055
1055
1120
1085
1085
2.15
1.96
1.96
2.87
2.65
2.65
2.41
2.24
2.24
3.86
3.90
6.75
5.13
5.08
8.80
4.76
4.50
7.80
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" clockwise,
direction of air flow "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
-10°
H
I
—
—
—
—
—
—
—
—
—
2
[Pa]
[in H O]
Curves
160
0,6
3
3
140
3
A
0,5
3
F1b)/F2b)
F1b)/F2b)
F1b)/F2b)
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1115
1.71
3.34
82
A
2
1100
1.97
3.65
82
A
3
1090
2.15
3.86
82
B
1
1080
1.60
3.28
81
B
2
1055
1.81
3.63
81
B
3
1035
1.96
3.90
81
C
1
1080
1.60
5.71
81
C
2
1055
1.81
6.32
81
C
3
1035
1.96
6.75
81
D
1
1120
2.44
4.64
82
D
2
1110
2.63
4.83
81
D
3
1100
2.87
5.13
80
E
1
1085
2.28
4.49
81
E
2
1070
2.45
4.75
80
E
3
1055
2.65
5.08
79
F
1
1085
2.28
7.81
81
F
2
1070
2.45
8.27
80
F
3
1055
2.65
8.80
79
D
2
0,4
2
100
-40 to +60
-40 to +60
-40 to +60
-40 to +45
-40 to +45
-40 to +45
-40 to +60
-40 to +60
-40 to +60
(1) Nominal data in operating point 3 with maximum load
subject to alterations
120
160
145
145
140
130
130
220
205
205
2
2
0,3
80
1
1
1
60
0,2
1
40
0,1
20
0
2000
5000
58
E
F
B
C
4000
6000
10000
8000
10000
15000
12000
20000
14000
16000
25000
18000
30000
[CFM]
[m3/h]
General information
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
❮ "V"
"A" ❯
With guard grille
for short nozzle
With guard grille
for full nozzle
"A" ❯
With guard grille
for short nozzle
"V"
"A"
A6D 910-AF05 -03
A6D 910-AF05 -04
W6D 910-GF05 -03
W6D 910-DF05 -04
S6D 910-CF05 -03
—
S6D 910-AF05 -03
—
—
S6D 910-BF05 -04
—
__
"V"
"A"
A6D 910-AB05 -03
A6D 910-AB05 -04
W6D 910-GB05 -03
W6D 910-DB05 -04
S6D 910-CB05 -03
—
S6D 910-AB05 -03
—
—
S6D 910-BB05 -04
—
__
"V"
"A"
A6D 910-AC05 -03
A6D 910-AC05 -04
W6D 910-GC05 -03
W6D 910-DC05 -04
S6D 910-CC05 -03
—
S6D 910-AC05 -03
—
—
S6D 910-BC05 -04
—
__
220
2
[in H O]
[Pa]
Curves
3
200
0,8
3
0,7
160
0,6
80
LwA
[dB(A)]
1
1140
1.87
4.29
83
2
1130
2.19
4.56
83
G
3
1120
2.41
4.76
94
H
1
1115
1.74
3.79
82
H
2
1100
2.00
4.20
83
H
3
1085
2.24
4.50
93
I
1
1115
1.74
6.59
82
I
2
1100
2.00
7.31
83
I
3
1085
2.24
7.80
93
0,4
100
I
[A]
1
1
0,3
120
0,5
140
P1
[kW]
G
2
2
n
[rpm]
G
G
180
AC centrifugal, backward
❮ "V"
With guard grille
for full nozzle
AC centrifugal, forward
❮ "V"/ "A" ❯
With full square
nozzle
Accessories
❮ "V"/ "A" ❯
Without attachments
Electrical connections
Direction of air flow
AC axial fans
–
–
–
–
–
60
0,2
H
I
0
2000
4000
5000
6000
10000
8000
15000
10000
12000
20000
14000
25000
16000 [CFM]
[m3/h]
59
Drawings
p. 62 f.
Motor protection
p. 122 f.
Electr. connections
p. 126
Representatives
20
0,1
40
AC axial fans - HyBlade®
Ø 910
Max. operative range
Perm. amp. temp.
Electr. connection
-5°
B
C
D
MZD 138-HF
Capacitor
A
*ZD 910
Max. current draw (1)
M8D 138-LA
Max. power input (1)
*8D 910
Speed (1)
Motor
Frequency
Type
Nominal voltage
Nominal data
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 126
3~ 480 Y
3~ 400 Y
3~ 230 Δ
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
60
60
60
795
740
740
485
440
440
1.42
1.25
1.25
0.61
0.50
0.50
2.75
2.68
4.65
1.31
1.20
2.08
Curve
Blade angle
– Material: Guard grille: Steel, phosphated and coated in black plastic
Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" clockwise,
direction of air flow "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
0°
E
F
—
—
—
—
—
—
[Pa]
2
0,4
3
3
A
0,35
90
[in H O]
Curves
100
80
2
0,25
0,2
50
1
0,15
1
40
B
C
0,1
30
0,05
20
10
0
2000
4000
60
F1b)/F2b)
F1b)/F2b)
4000
8000
6000
8000
12000
10000
16000
12000
20000
14000
[CFM]
24000
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
820
1.18
2.54
73
A
2
805
1.29
2.66
72
A
3
795
1.42
2.75
73
B
1
780
1.06
2.40
71
B
2
765
1.16
2.55
70
B
3
740
1.25
2.68
72
C
1
780
1.06
4.18
71
C
2
765
1.16
4.44
70
C
3
740
1.25
4.65
72
0,3
2
70
60
-40 to +60
-40 to +60
-40 to +60
-40 to +60
-40 to +60
-40 to +60
(1) Nominal data in operating point 3 with maximum load
subject to alterations
110
110
95
95
50
40
40
General information
Motor protection: Design with thermal overload protector
Cable exit: Via terminal box
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
❮ "V"
"A" ❯
With guard grille
for short nozzle
With guard grille
for full nozzle
"A" ❯
With guard grille
for short nozzle
"V"
"A"
A8D 910-AE07 -03
A8D 910-AE07 -04
W8D 910-GE07 -03
W8D 910-DE07 -04
S8D 910-CE07 -03
—
S8D 910-AE07 -03
—
—
S8D 910-BE07 -04
—
__
"V"
"A"
AZD 910-AG07 -03
AZD 910-AG07 -04
WZD 910-GG07 -03
WZD 910-DG07 -04
SZD 910-CG07 -03
—
SZD 910-AG07 -03
—
—
SZD 910-BG07 -04
—
__
50
2
[in H O]
0,2
[Pa]
Curves
3
D
3
2
0,15
40
AC centrifugal, backward
❮ "V"
With guard grille
for full nozzle
AC centrifugal, forward
❮ "V"/ "A" ❯
With full square
nozzle
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
D
1
505
0.54
1.24
60
D
2
490
0.59
1.28
60
D
3
485
0.61
1.31
62
E
1
470
0.45
1.13
58
E
2
450
0.48
1.18
58
E
3
440
0.50
1.20
60
F
1
470
0.45
1.97
58
F
2
450
0.48
2.05
58
F
3
440
0.50
2.08
60
Accessories
❮ "V"/ "A" ❯
Without attachments
Electrical connections
Direction of air flow
AC axial fans
–
–
–
–
–
2
0,1
30
1
1
20
0,05
E
F
0
2000
4000
4000
6000
8000
8000
12000
10000
16000
[CFM]
[m3/h]
61
Drawings
p. 62 f.
Motor protection
p. 122 f.
Electr. connections
p. 126
Representatives
10
AC axial fans - HyBlade®
Ø 910, drawings for direction of air flow "V"
Type
Without attachments
A6D
A6D
A6D
A8D
AZD
-03
-03
-03
-03
-03
c
25,1
139,0
28,1
145,0 106,0 297,0
28,1
139,0
25,1
145,0 106,0 277,0
20,1
149,0 119,0 252,0
d
94,0 297,0
162±0,3
Internal diameter of the
wall ring at least 913 mm
76
8xM10
Depth of screw
max. 18 mm
g±2
Screwed cable gland
❮ "V"
Type
With full square nozzle
Mass
[kg]
W6D 910-GF05
W6D 910-GB05
W6D 910-GC05
W8D 910-GE07
WZD 910-GG07
45,1
48,1
48,1
45,1
40,1
Ø14,5
Ø976
277±5
-03
-03
-03
-03
-03
1010±1
1070-3
20
205
❮ "V"
Type
76
20
Ø931
Ø975
116
88±3
s±4
t±3
❮ "V"
62
29
View X
15±0,5
10
With guard grille for full nozzle
S6D
S6D
S6D
S8D
SZD
Mass
[kg]
910-CF05
910-CB05
910-CC05
910-CE07
910-CG07
-03
-03
-03
-03
-03
s
t
36,1
127,0 189,0
39,1
133,0 209,0
39,1
127,0 209,0
36,1
133,0 189,0
31,1
137,0 164,0
Internal diameter of the
wall ring at least 913 mm
g
94,0 277,0
905±2
99x99
c±3
d±2
910-AF05
910-AB05
910-AC05
910-AE07
910-AG07
Mass
[kg]
General information
S6D
S6D
S6D
S8D
SZD
-03
-03
-03
-03
-03
u
38,1
9,0
71,0
41,1
15,0
91,0
41,1
9,0
91,0
38,1
15,0
71,0
33,1
19,0
46,0
v
Ø1075
Ø1044
u±4
910-AF05
910-AB05
910-AC05
910-AE07
910-AG07
Mass
[kg]
AC axial fans
Type
With guard grille for short nozzle
10
v±3
Electrical connections
Accessories
AC centrifugal, forward
❮ "V"
63
Representatives
4
205±3
AC centrifugal, backward
Internal diameter of the
wall ring at least 913 mm
AC axial fans - HyBlade®
Ø 910, drawings for direction of air flow "A"
Type
Without attachments
A6D
A6D
A6D
A8D
AZD
-04
-04
-04
-04
-04
c
25,1
145,0
28,1
152,0 106,0 297,0
28,1
145,0
25,1
152,0 106,0 277,0
20,1
159,0 119,0 252,0
d
94,0 297,0
162±0,3
905±2
Internal diameter of the
wall ring at least 913 mm
76
g±2
8xM10
Depth of screw
max. 18 mm
Screwed cable gland
"A" ❯
Type
With full square nozzle
Mass
[kg]
W6D 910-DF05
W6D 910-DB05
W6D 910-DC05
W8D 910-DE07
WZD 910-DG07
46,6
49,6
49,6
46,6
41,6
Ø14,5
Ø976
267±5
-04
-04
-04
-04
-04
1010±1
1070-3
20
205
"A" ❯
Type
With guard grille for full nozzle
910-BF05
910-BB05
910-BC05
910-BE07
910-BG07
-04
-04
-04
-04
-04
t±3
"A" ❯
64
10
t
159,0 215,0
40,1
166,0 235,0
40,1
159,0 235,0
37,1
166,0 215,0
32,1
173,0 190,0
Internal diameter of the
wall ring at least 913 mm
61±3
s
37,1
Ø1075
s±4
Ø1017
4
S6D
S6D
S6D
S8D
SZD
Mass
[kg]
g
94,0 277,0
99x99
c±3
d±2
910-AF05
910-AB05
910-AC05
910-AE07
910-AG07
Mass
[kg]
Representatives
65
Electrical connections
Accessories
AC centrifugal, forward
AC centrifugal, backward
AC axial fans
General information
66
Accessories
AC centrifugal, forward
AC centrifugal, backward
Ø 450 - Ø 630
Electrical connections
AC centrifugal fans, backward curved
67
AC axial fans
68
Representatives
General information
AC centrifugal fans backward curved
AC centrifugal fans
backward curved, 3-D, Ø 450
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
1660
1600
1600
1.32
1.21
1.21
2.46
2.37
4.11
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 450 (2)
M4D 110-IA
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
—
—
—
-40 to +65
-40 to +65
-40 to +65
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
2
[Pa]
[in H O]
Curves
3,0
800
3
3
600
2
2,0
2
1
400
1
A
1,0
B
C
200
0
1000
2000
68
2000
3000
4000
4000
6000
[CFM]
[m3/h]
D1)/D2)
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1660
1.30
2.44
80
A
2
1660
1.32
2.46
75
A
3
1670
1.24
2.38
79
B
1
1610
1.19
2.33
79
B
2
1600
1.21
2.37
74
B
3
1620
1.15
2.26
78
C
1
1620
1.19
4.04
79
C
2
1600
1.21
4.11
74
C
3
1620
1.15
3.91
78
General information
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
R4D 450-AH03 -01
14.5
Inlet nozzle
(long)
63045-2-4013
AC centrifugal, forward
kg
234±2
75
45˚
11
5±
0.
3
5,5
Accessories
Ø450
Ø289
Ø284,5
Ø300
Ø485
80
0
Ø100
4x90˚
Ø455
87
49
28
2
M6
Electrical connections
4
Depth of screw max. 12 mm
Mounting dimensions
Ø7
Ø
5
Ø
11
0
10
Ø 130
140
209
4x90˚
Brass lead tips
28
69
Inlet nozzles
p. 120
Guard grille
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
Centrifugal fan
AC centrifugal fans
backward curved, 3-D, Ø 450
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
1110
1060
1060
0.44
0.40
0.40
0.81
0.77
1.33
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 450 (2)
M6D 110-EF
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
—
—
—
-40 to +70
-40 to +70
-40 to +70
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
2
[Pa]
[in H O]
Curves
3
300
1,0
2
0,5
200
1
100
1
A
B
C
0
500
1000
70
1000
1500
2000
2000
3000
2500
4000
[CFM]
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1110
0.40
0.79
70
A
2
1110
0.44
0.81
66
A
3
1110
0.42
0.80
69
B
1
1070
0.37
0.73
69
B
2
1060
0.40
0.77
65
B
3
1060
0.38
0.74
68
C
1
1070
0.37
1.26
69
C
2
1060
0.40
1.33
65
C
3
1060
0.38
1.28
68
3
2
D1)/D2)
General information
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
R6D 450-AN01 -01
10.0
Inlet nozzle
(long)
63045-2-4013
AC centrifugal, forward
kg
234±2
75
45˚
11
5±
0.
3
5,5
Accessories
Ø450
Ø289
Ø284,5
Ø300
Ø485
80
0
Ø100
4x90˚
Ø455
87
49
28
2
M6
Electrical connections
4
Depth of screw max. 12 mm
Mounting dimensions
Ø7
Ø
5
Ø
11
0
10
Ø 130
140
209
4x90˚
Brass lead tips
28
71
Inlet nozzles
p. 120
Guard grille
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
Centrifugal fan
AC centrifugal fans
backward curved, 3-D, Ø 450
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
°C
p. 127
60
1060
0.43
1.85
8.0/450
-40 to +55
A2a)
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6E 450
M6E 110-EF
subject to alterations
1~ 230
A
(1) Nominal data in operating point with maximum load
2
[Pa]
[in H O]
Curves
A
1
1090
0.39
1.72
69
A
2
1060
0.43
1.85
64
A
3
1100
0.38
1.65
70
A
4
840
0.26
1.71
62
A
5
750
0.27
1.80
55
A
6
890
0.26
1.70
65
A
7
590
0.18
1.50
52
A
8
540
0.18
1.50
47
A
9
630
0.18
1.50
56
A
10
450
0.11
1.20
45
A
11
410
0.11
1.20
43
A
12
470
0.11
1.20
48
3
1,0
300
2
6
200
A
5
0,5
9
1
100
12
8
4
11
7
10
0
500
1000
1000
1500
2000
105 V
72
2000
3000
130 V
2500
4000
160 V
[CFM]
[m3/h]
230 V
General information
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
R6E 450-AN01 -01
10.0
Inlet nozzle
(long)
63045-2-4013
AC centrifugal, forward
kg
234±2
75
45˚
11
5±
0.
3
5,5
Accessories
Ø450
Ø289
Ø284,5
Ø300
Ø485
80
0
Ø100
4x90˚
Ø455
87
49
28
2
M6
Electrical connections
4
Depth of screw max. 12 mm
Mounting dimensions
Ø7
Ø
5
Ø
11
0
10
Ø 130
140
209
4x90˚
Brass lead tips
28
73
Inlet nozzles
p. 120
Guard grille
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
Centrifugal fan
AC centrifugal fans
backward curved, 3-D, Ø 500
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
1670
1600
1600
2.40
2.24
2.24
3.90
3.90
6.75
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 500 (2)
M4D 138-LA
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
—
—
—
-40 to +70
-40 to +70
-40 to +70
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
2
[Pa]
[in H O]
Curves
3,0
800
3
3
600
2
2,0
2
400
1
1
1,0
A
B
C
200
0
1000
2000
74
2000
3000
4000
4000
6000
5000
8000
[CFM]
[m3/h]
D1)/D2)
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1670
2.30
3.70
86
A
2
1670
2.40
3.90
82
A
3
1670
2.30
3.69
83
B
1
1610
2.16
3.77
85
B
2
1600
2.24
3.90
81
B
3
1610
2.15
3.75
82
C
1
1610
2.16
6.53
85
C
2
1600
2.24
6.75
81
C
3
1610
2.15
6.50
82
General information
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
R4D 500-AQ05 -01
27.0
Inlet nozzle
(long)
63072-2-4013
249±2
75
5,5
3
±0.
162
AC centrifugal, forward
kg
22,5˚
˚
45
8x
Accessories
Ø470
Ø342
Ø337
Ø355
Ø505
1000
Ø480
Ø140
87
49
28
175
233
5
2
M10
Electrical connections
Brass lead tips
Depth of screw max. 18 mm
75
Inlet nozzles
p. 120
Guard grille
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
Centrifugal fan
AC centrifugal fans
backward curved, 3-D, Ø 500
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
1065
1000
1000
0.78
0.70
0.70
1.27
1.28
2.21
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 500 (2)
M6D 110-GF
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
—
—
—
-40 to +45
-40 to +45
-40 to +45
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
2
[Pa]
[in H O]
Curves
1,5
400
3
3
300
1,0
200
1
1
0,5
A
100
B
C
0
1000
2000
76
2000
3000
4000
4000
6000
[CFM]
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1070
0.73
1.23
73
A
2
1065
0.78
1.27
71
A
3
1080
0.72
1.21
71
B
1
1020
0.66
1.22
71
B
2
1000
0.70
1.28
69
B
3
1020
0.66
1.21
70
C
1
1020
0.66
2.11
71
C
2
1000
0.70
2.21
69
C
3
1020
0.66
2.10
70
2
2
D1)/D2)
General information
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
R6D 500-AK03 -01
13.0
Inlet nozzle
(long)
63072-2-4013
AC centrifugal, forward
kg
245±2
75
45˚
11
5±
0.
3
5,5
Accessories
Ø470
Ø342
Ø337
Ø355
Ø505
80
0
Ø100
4x90˚
Ø480
87
49
28
2
M6
Electrical connections
5
Depth of screw max. 12 mm
Mounting dimensions
Ø7
Ø
5
Ø
11
0
10
Ø 130
175
233
4x90˚
Brass lead tips
28
77
Inlet nozzles
p. 120
Guard grille
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
Centrifugal fan
AC centrifugal fans
backward curved, 3-D, Ø 500
Electr. connection
subject to alterations
Perm. amp. temp.
A
Capacitor
M6E 110-IA
Max. current draw (1)
R6E 500
Max. power input (1)
Motor
Speed (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
μF/VDB
°C
p. 127
60
1020
0.76
3.33
12.0/450
-40 to +40
A2a)
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
1~ 230
(1) Nominal data in operating point with maximum load
2
[Pa]
[in H O]
Curves
1,5
400
3
300
1,0
2
A
A
1
1040
0.72
3.18
72
A
2
1020
0.76
3.33
66
A
3
1040
0.72
3.17
69
A
4
680
0.42
2.90
60
A
5
650
0.42
2.90
57
A
6
710
0.42
2.90
59
A
7
520
0.28
2.40
53
A
8
490
0.28
2.40
50
A
9
530
0.28
2.40
52
A
10
400
0.18
2.00
48
A
11
390
0.18
2.00
45
A
12
410
0.18
2.00
46
200
1
0,5
6
5
100
9
4
8
12
7
11
10
0
1000
2000
2000
3000
4000
105 V
78
4000
6000
130 V
160 V
[CFM]
[m3/h]
230 V
General information
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
R6E 500-AH03 -01
14.8
Inlet nozzle
(long)
63072-2-4013
AC centrifugal, forward
kg
245±2
75
45˚
11
5±
0.
3
5,5
Accessories
Ø470
Ø342
Ø337
Ø355
Ø505
80
0
Ø100
4x90˚
Ø480
87
49
28
2
M6
Electrical connections
5
Depth of screw max. 12 mm
Mounting dimensions
Ø7
Ø
5
Ø
11
0
10
Ø 130
175
233
4x90˚
Brass lead tips
28
79
Inlet nozzles
p. 120
Guard grille
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
Centrifugal fan
AC centrifugal fans
backward curved, 3-D, Ø 560
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
1610
1520
1520
3.80
3.50
3.50
5.85
6.05
10.46
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 560 (2)
M4D 138-NA
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
—
—
—
-40 to +60
-40 to +60
-40 to +60
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
[Pa]
2
4,0
1000
4,8 [in H O]
Curves
1200
3,2
3
600
2,4
400
1,6
2
2
1
200
0,8
1
B
C
0
2000
2000
80
A
4000
4000
6000
6000
8000
10000
[CFM]
12000
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1630
3.50
5.49
88
A
2
1610
3.80
5.85
85
A
3
1630
3.40
5.34
86
B
1
1550
3.25
5.65
86
B
2
1520
3.50
6.05
84
B
3
1550
3.16
5.51
84
C
1
1550
3.25
9.79
86
C
2
1520
3.50
10.46
84
C
3
1550
3.16
9.54
84
3
800
D1)/D2)
General information
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
R4D 560-AW03 -01
29.0
Inlet nozzle
(long)
63071-2-4013
274±2
82
5,5
3
±0.
162
AC centrifugal, forward
kg
22,5˚
˚
45
8x
Accessories
Ø515
Ø385
Ø380
Ø398
Ø565
1000
Ø540
Ø140
95
60
30
195
258
5
2
M10
Electrical connections
Brass lead tips
Depth of screw max. 18 mm
81
Inlet nozzles
p. 120
Guard grille
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
Centrifugal fan
AC centrifugal fans
backward curved, 3-D, Ø 560
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
1100
1050
1050
1.33
1.22
1.22
2.55
2.40
4.15
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 560 (2)
M6D 138-HF
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
—
—
—
-40 to +70
-40 to +70
-40 to +70
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
2
2,0
[Pa]
[in H O]
Curves
500
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1110
1.19
2.32
76
A
2
1100
1.33
2.55
75
A
3
1100
1.30
2.41
76
B
1
1080
1.09
2.20
75
B
2
1050
1.22
2.40
75
B
3
1060
1.19
2.34
75
C
1
1080
1.09
3.81
75
C
2
1050
1.22
4.15
75
C
3
1060
1.19
4.05
75
3
400
1,5
3
2
300
1,0
2
200
1
A
0,5
1
B
C
100
0
1000
2000
82
D1)/D2)
2000
3000
4000
4000
6000
5000
8000
[CFM]
[m3/h]
General information
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
R6D 560-AT03 -01
25.0
Inlet nozzle
(long)
63071-2-4013
274±2
82
5,5
3
±0.
162
AC centrifugal, forward
kg
22,5˚
˚
45
8x
Accessories
Ø515
Ø385
Ø380
Ø398
Ø565
1000
Ø540
Ø140
95
60
30
195
258
5
2
M10
Electrical connections
Brass lead tips
Depth of screw max. 18 mm
83
Inlet nozzles
p. 120
Guard grille
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
Centrifugal fan
AC centrifugal fans
backward curved, 3-D, Ø 630
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
1065
1000
1000
2.21
2.00
2.00
3.58
3.72
6.44
Curve
Nominal voltage
– Material: Impeller: Sheet aluminium, welded
Rotor: Cast in aluminium
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 630 (2)
M6D 138-NA
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
—
—
—
-40 to +50
-40 to +50
-40 to +50
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
2
[Pa]
[in H O]
Curves
2,5
700
600
500
3
2
400
1,5
2
1
300
1,0
1
A
200
0,5
B
C
100
0
84
1500
3000
2500
5000
4500
7500
6000
10000
7500
12500
[CFM]
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1070
2.13
3.48
78
A
2
1065
2.21
3.58
77
A
3
1080
2.05
3.35
78
B
1
1010
1.94
3.61
76
B
2
1000
2.00
3.72
75
B
3
1020
1.85
3.44
76
C
1
1010
1.94
6.25
76
C
2
1000
2.00
6.44
75
C
3
1020
1.85
5.95
76
2,0
3
D1)/D2)
General information
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
R6D 630-AW03 -01
30.0
Inlet nozzle
(long)
63070-2-4013
305,5±2
98,5
5,5
3
±0.
162
AC centrifugal, forward
kg
22,5˚
˚
45
8x
Accessories
Ø634
Ø433
Ø427
Ø447
Ø635
1000
Ø635
Ø140
114
72
37
220
290
6
2
M10
Electrical connections
Brass lead tips
Depth of screw max. 18 mm
85
Inlet nozzles
p. 120
Guard grille
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
Centrifugal fan
86
Accessories
AC centrifugal, forward
AC centrifugal, backward
Ø 250 - Ø 400
Electrical connections
AC centrifugal fans, forward curved, single inlet
87
AC axial fans
88
Representatives
General information
AC centrifugal fans, forward curved
AC centrifugal fans
single inlet, Ø 250
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Min. back pressure
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
1650
1580
1580
1.24
1.17
1.17
1.95
2.00
3.46
—
—
—
0
0
0
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 250 (2)
M4D 110-GF
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
2
[Pa]
[in H O]
2,0
4
400
1,6
480
1,2
0,8
2
160
2
0,4
A
B
C
80
1
0
200
400
88
400
600
800
800
1200
1000
1600
1200
2000
1400
1
[CFM]
2400
[m3/h]
P1
[kW]
I
[A]
LwA
[dB(A)]
1
1650
1.24
1.95
90
A
2
1680
1.04
1.75
88
A
3
1710
0.81
1.51
85
A
4
1750
0.50
1.26
80
B
1
1580
1.17
2.00
89
B
2
1620
0.98
1.76
86
B
3
1670
0.77
1.46
85
B
4
1730
0.47
1.08
80
C
1
1580
1.17
3.46
89
C
2
1620
0.98
3.05
86
C
3
1670
0.77
2.53
85
C
4
1730
0.47
1.87
80
320
240
n
[rpm]
A
3
3
D1)/D2)
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
Curves
4
-40 to +45
-40 to +45
-40 to +45
General information
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Centrifugal fan
kg
R4D 250-CG07 -01
12.0
Inlet nozzle
Flange
25010-2-4013
94250-2-4017
View without flange
214
137,5±2
102
AC centrifugal, forward
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
View with flange
50-2
6x60˚
4x90˚
Accessories
800
Ø193
Ø300
Ø250
Ø249
M6
Ø7
Z
Brass lead tips
29±1
4,5
Ø100
163±1
Ø115±0,3
Ø285±1
Ø300
View Z
Electrical connections
6x60˚
Ø2
85
±1
Housing width
Depth of screw
max. 12 mm
Scroll housing used:
Ø7
150
Mounting dimensions
203
4x90˚
147
30
˚
170
184
158
28
89
Inlet nozzles
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
30˚
Ø 130
˚
30
30˚
˚
30
198
18
30˚ 30˚
0
10
30˚
213
5
138
Ø
65
˚
25˚
230
30˚
11
247
Ø
267
287
Ø7
AC centrifugal fans
single inlet, Ø 250
subject to alterations
Capacitor
Min. back pressure
Perm. amp. temp.
Electr. connection
M4E 110-GF
Max. current draw (1)
R4E 250
Max. power input (1)
Motor
Speed (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 127
60
1240
0.82
3.70
12.0/500
0
1~ 230
A
2
[in H O]
1,8
A
1,6
[Pa]
360
4
1,4
400
1,2
320
3
160
0,8
0,6
200
1,0
280
240
2
0,4
120
0,2
80
40
1
0
200
400
90
A2a)
(1) Nominal data in operating point with maximum load
Curves
440
-40 to +60
400
600
800
800
1200
1000
1600
[CFM]
2000 [m /h]
3
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1240
0.82
3.70
83
A
2
1430
0.76
3.31
82
A
3
1550
0.68
2.97
81
A
4
1660
0.56
2.57
79
General information
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Centrifugal fan
kg
R4E 250-CG01 -01
12.0
Inlet nozzle
Flange
25010-2-4013
94250-2-4017
View without flange
214
137,5±2
102
AC centrifugal, forward
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
View with flange
50-2
6x60˚
4x90˚
Accessories
800
Ø193
Ø300
Ø250
Ø249
M6
Ø7
Z
Brass lead tips
29±1
4,5
Ø100
163±1
Ø115±0,3
Ø285±1
Ø300
View Z
Electrical connections
6x60˚
Ø2
85
±1
Housing width
Depth of screw
max. 12 mm
Scroll housing used:
Ø7
150
Mounting dimensions
203
4x90˚
147
30
˚
170
184
158
28
91
Inlet nozzles
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
30˚
Ø 130
˚
30
30˚
˚
30
198
18
30˚ 30˚
0
10
30˚
213
5
138
Ø
65
˚
25˚
230
30˚
11
247
Ø
267
287
Ø7
AC centrifugal fans
single inlet, Ø 250
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Min. back pressure
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
1100
1060
1060
0.42
0.38
0.38
0.80
0.76
1.32
—
—
—
0
0
0
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 250 (2)
M6D 110-EF
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
2
[in H O]
[Pa]
180
0,9
0,8
200
0,7
220
4
4
0,6
160
3
80
0,5
0,4
0,3
100
2
2
60
0,2
A
40
B
C
0,1
20
1
0
200
400
92
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1100
0.42
0.80
81
A
2
1120
0.36
0.75
78
A
3
1140
0.31
0.72
75
A
4
1160
0.23
0.67
71
B
1
1060
0.38
0.76
80
B
2
1090
0.33
0.69
77
B
3
1110
0.28
0.63
74
B
4
1140
0.20
0.55
71
C
1
1060
0.38
1.32
80
C
2
1090
0.33
1.20
77
C
3
1110
0.28
1.10
74
C
4
1140
0.20
0.96
71
3
140
120
D1)/D2)
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
Curves
240
-40 to +85
-40 to +85
-40 to +85
400
600
800
1000
800
1200
1600
1
[CFM]
[m3/h]
General information
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Centrifugal fan
kg
Inlet nozzle
Flange
R6D 250-CE01 -01
9.5
25010-2-4013
94250-2-4017
View without flange
214
137,5±2
102
AC centrifugal, forward
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
View with flange
50-2
6x60˚
4x90˚
Accessories
800
Ø193
Ø300
Ø250
Ø249
M6
Ø7
Z
Brass lead tips
29±1
4,5
Ø100
163±1
Ø115±0,3
Ø285±1
Ø300
View Z
Electrical connections
6x60˚
Ø2
85
±1
Housing width
Depth of screw
max. 12 mm
Scroll housing used:
Ø7
150
Mounting dimensions
203
4x90˚
147
30
˚
170
184
158
28
93
Inlet nozzles
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
30˚
Ø 130
˚
30
30˚
˚
30
198
18
30˚ 30˚
0
10
30˚
213
5
138
Ø
65
˚
25˚
230
30˚
11
247
Ø
267
287
Ø7
AC centrifugal fans
single inlet, Ø 250
Min. back pressure
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 127
60
780
0.31
1.37
6.0/450
0
1~ 230
A
subject to alterations
Capacitor
M6E 094-FA
Max. current draw (1)
R6E 250
Max. power input (1)
Motor
Speed (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
2
[Pa]
[in H O]
1,0
240
180
0,8
3
0,7
200
0,9
4
220
A
0,6
160
80
0,4
2
0,3
100
0,5
140
120
0,2
60
0,1
40
20
0
100
200
94
A2a)
(1) Nominal data in operating point with maximum load
Curves
260
-40 to +70
200
300
400
400
600
500
800
600
1000
700
1200
1
800 [CFM]
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
780
0.31
1.37
74
A
2
970
0.28
1.23
74
A
3
1080
0.25
1.07
72
A
4
1130
0.21
0.91
69
General information
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL
Centrifugal fan
kg
Inlet nozzle
Flange
R6E 250-CA08 -01
7.0
25010-2-4013
94250-2-4017
View without flange
214
137,5±2
102
AC centrifugal, forward
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
View with flange
50-2
6x60˚
4x90˚
Accessories
600
Ø193
Ø300
Ø250
Ø249
M6
Ø7
Z
Brass lead tips
29±1
4,5
Ø100
163±1
Ø115±0,3
Ø285±1
Ø300
View Z
Electrical connections
6x60˚
Ø2
85
±1
Housing width
Depth of screw
max. 12 mm
Scroll housing used:
Ø7
150
Mounting dimensions
203
4x90˚
147
30
˚
170
184
158
28
95
Inlet nozzles
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
30˚
55
˚
30
30˚
˚
30
198
18
30˚ 30˚
0
10
30˚
213
5
138
Ø
65
˚
25˚
230
30˚
11
247
Ø
267
287
Ø7
AC centrifugal fans
single inlet, Ø 280
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Min. back pressure
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
1590
1500
1500
1.80
1.63
1.63
2.96
2.90
5.05
—
—
—
250
235
235
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 280 (2)
M4D 110-IA
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
2
[in H O]
3,6
3,2
[Pa]
700
4
4
2,8
800
500
2,0
600
2,4
3
3
300
A
B
C
1,2
400
2
1,6
2
0,8
100
0,4
1
200
0
250
500
96
500
750
1000
1000
1500
1250
2000
1500
2200
1
1750
[CFM]
3000
[m3/h]
D1)/D2)
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
Curves
900
-40 to +45
-40 to +45
-40 to +45
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1590
1.80
2.96
89
A
2
1650
1.38
2.42
87
A
3
1700
1.02
2.06
85
A
4
1730
0.71
1.82
84
B
1
1500
1.63
2.90
88
B
2
1580
1.30
2.40
87
B
3
1650
0.98
1.93
85
B
4
1700
0.66
1.51
84
C
1
1500
1.63
5.05
88
C
2
1580
1.30
4.16
87
C
3
1650
0.98
3.35
85
C
4
1700
0.66
2.62
84
General information
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Centrifugal fan
kg
R4D 280-CI03 -01
14.5
Inlet nozzle
Flange
28010-2-4013
10280-2-4017
View without flange
233
149,5±2
114
AC centrifugal, forward
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
View with flange
57-2
6x60˚
4x90˚
Accessories
800
Ø228
Ø336
Ø280
Ø296
M6
Ø7
Z
Brass lead tips
29±1
5,5
Ø100
183±1
Ø115±0,3
Ø315±1
Ø336
View Z
Electrical connections
6x60˚
Ø3
15
±1
Housing width
Depth of screw
max. 12 mm
Scroll housing used:
Ø7
180
Mounting dimensions
205
4x90˚
152
30
˚
161
172
148
28
97
Inlet nozzles
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
30˚
Ø 130
˚
30
30˚
˚
30
183
13
30˚ 30˚
0
10
30˚
200
5
162
Ø
65
˚
25˚
218
30˚
11
236
Ø
254
266
Ø7
AC centrifugal fans
single inlet, Ø 280
subject to alterations
Capacitor
Min. back pressure
Perm. amp. temp.
Electr. connection
M4E 110-IA
Max. current draw (1)
R4E 280
Max. power input (1)
Motor
Speed (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 127
60
1410
1.17
5.13
16.0/400
350
1~ 230
A
2
[Pa]
[in H O]
3,2
4
2,8
700
3
2,4
500
2,0
400
1,6
A
600
2
200
0,8
100
0,4
1,2
1
300
0
200
400
98
A2a)
(1) Nominal data in operating point with maximum load
Curves
800
-40 to +45
400
600
800
800
1200
1000
1600
1200
2000
1400 [CFM]
2400 [m /h]
3
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1410
1.17
5.13
84
A
2
1510
1.09
4.72
84
A
3
1630
0.92
4.00
83
A
4
1690
0.78
3.52
84
General information
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Centrifugal fan
kg
R4E 280-CI01 -01
14.5
Inlet nozzle
Flange
28010-2-4013
10280-2-4017
View without flange
233
149,5±2
114
AC centrifugal, forward
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
View with flange
57-2
6x60˚
4x90˚
Accessories
800
Ø228
Ø336
Ø280
Ø296
M6
Ø7
Z
Brass lead tips
29±1
5,5
Ø100
183±1
Ø115±0,3
Ø315±1
Ø336
View Z
Electrical connections
6x60˚
Ø3
15
±1
Housing width
Depth of screw
max. 12 mm
Scroll housing used:
Ø7
180
Mounting dimensions
205
4x90˚
152
30
˚
161
172
148
28
99
Inlet nozzles
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
30˚
Ø 130
˚
30
30˚
˚
30
183
13
30˚ 30˚
0
10
30˚
200
5
162
Ø
65
˚
25˚
218
30˚
11
236
Ø
254
266
Ø7
AC centrifugal fans
single inlet, Ø 280
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Min. back pressure
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
1040
975
975
0.60
0.54
0.54
1.00
0.98
1.70
—
—
—
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 280 (2)
M6D 110-EF
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
100
88
88
2
[Pa]
1,6 [in H O]
1,4
360
4
4
1,2
320
160
1,0
0,8
B
C
2
2
0,6
200
A
0,4
120
1
1
40
0,2
80
0
200
400
100
400
600
800
800
1200
1000
1600
1200
2000
[CFM]
[m3/h]
P1
[kW]
I
[A]
LwA
[dB(A)]
1
1040
0.60
1.00
80
A
2
1070
0.52
0.88
78
A
3
1100
0.42
0.78
77
A
4
1140
0.28
0.68
74
B
1
975
0.54
0.98
78
B
2
1010
0.47
0.87
77
B
3
1060
0.38
0.74
76
B
4
1120
0.25
0.59
73
C
1
975
0.54
1.70
78
C
2
1010
0.47
1.51
77
C
3
1060
0.38
1.29
76
C
4
1120
0.25
1.03
73
3
3
n
[rpm]
A
280
240
D1)/D2)
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
Curves
400
-40 to +50
-40 to +50
-40 to +50
General information
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Centrifugal fan
kg
R6D 280-CE01 -01
10.0
Inlet nozzle
Flange
28010-2-4013
10280-2-4017
View without flange
233
149,5±2
114
AC centrifugal, forward
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
View with flange
57-2
6x60˚
4x90˚
Accessories
800
Ø228
Ø336
Ø280
Ø296
M6
Ø7
Z
Brass lead tips
29±1
5,5
Ø100
183±1
Ø115±0,3
Ø315±1
Ø336
View Z
Electrical connections
6x60˚
Ø3
15
±1
Housing width
Depth of screw
max. 12 mm
Scroll housing used:
Ø7
180
Mounting dimensions
205
4x90˚
152
30
˚
161
172
148
28
101
Inlet nozzles
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
30˚
Ø 130
˚
30
30˚
˚
30
183
13
30˚ 30˚
0
10
30˚
200
5
162
Ø
65
˚
25˚
218
30˚
11
236
Ø
254
266
Ø7
AC centrifugal fans
single inlet, Ø 280
subject to alterations
Min. back pressure
Perm. amp. temp.
Electr. connection
A
Capacitor
M6E 094-HA
Max. current draw (1)
R6E 280
Max. power input (1)
Motor
Speed (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 127
60
880
0.52
2.27
12.0/500
50
1~ 230
2
[Pa]
1,6 [in H O]
1,4
360
1,2
320
4
280
1,0
A
240
0,6
160
0,8
3
200
2
0,4
120
0,2
80
40
0
1
200
400
102
A2a)
(1) Nominal data in operating point with maximum load
Curves
400
-40 to +45
400
600
800
800
1200
1000
1600
1200 [CFM]
2000 [m /h]
3
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
880
0.52
2.27
78
A
2
950
0.50
2.18
77
A
3
1030
0.46
2.03
75
A
4
1090
0.41
1.80
73
General information
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL
Centrifugal fan
kg
Inlet nozzle
Flange
R6E 280-CC05 -01
9.5
28010-2-4013
10280-2-4017
View without flange
233
149,5±2
114
AC centrifugal, forward
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
View with flange
57-2
6x60˚
4x90˚
Accessories
600
Ø228
Ø336
Ø280
Ø296
M6
Ø7
Z
Brass lead tips
29±1
5,5
Ø100
183±1
Ø115±0,3
Ø315±1
Ø336
View Z
Electrical connections
6x60˚
Ø3
15
±1
Housing width
Depth of screw
max. 12 mm
Scroll housing used:
Ø7
180
Mounting dimensions
205
4x90˚
152
30
˚
161
172
148
28
103
Inlet nozzles
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
30˚
55
˚
30
30˚
˚
30
183
13
30˚ 30˚
0
10
30˚
200
5
162
Ø
65
˚
25˚
218
30˚
11
236
Ø
254
266
Ø7
AC centrifugal fans
single inlet, Ø 310
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Min. back pressure
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
1590
1490
1490
2.75
2.49
2.49
3.98
4.23
7.31
—
—
—
400
350
350
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 310 (2)
M4D 138-HF
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
2
[Pa]
[in H O]
3,6
D1)/D2)
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
Curves
900
-40 to +40
-40 to +40
-40 to +40
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1590
2.75
3.98
92
A
2
1630
2.25
3.33
90
A
3
1675
1.78
2.77
88
A
4
1715
1.24
2.18
86
B
1
1490
2.49
4.23
91
B
2
1560
2.08
3.51
89
B
3
1615
1.67
2.88
86
B
4
1680
1.16
2.14
84
C
1
1490
2.49
7.31
91
C
2
1560
2.08
6.08
89
C
3
1615
1.67
4.99
86
C
4
1680
1.16
3.71
84
4
4
3,2
800
3
A
2,8
3
700
2
400
2,4
2
2,0
500
B
C
1,6
600
1
200
0,8
100
0,4
300
1,2
1
0
500
1000
104
1000
1500
2000
2500
2000
3000
4000
[CFM]
[m3/h]
General information
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Centrifugal fan
kg
R4D 310-CK03 -01
24.5
Inlet nozzle
Flange
31010-2-4013
38310-2-4017
View without flange
256
180±2
128
View with flange
61-2
6x60˚
Ø9
Accessories
Ø257
Ø374
Ø327
Ø315
M10
8x45˚
1000
AC centrifugal, forward
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
Z
4
Housing width
Ø162±0,3
6x60˚
Ø3
Brass lead tips
View Z
Ø350±1
Ø374
Electrical connections
Ø140
±1
203±1
50
42±1
Depth of screw
max. 18 mm
Scroll housing used:
30
˚
65
˚
176
186
200
214
105
Inlet nozzles
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
30˚
30˚ 30˚
229
246
˚
30
30
˚
30˚
264
18
25˚
283
30˚
30˚
303
Ø9
249
325
349
184
AC centrifugal fans
single inlet, Ø 310
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Min. back pressure
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
950
845
845
0.71
0.60
0.60
1.09
1.10
1.90
—
—
—
225
175
175
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 310 (2)
M6D 110-GF
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
2
[Pa]
[in H O]
1,6
4
4
3
1,2
320
2
280
B
C
1,0
240
2
0,8
1
200
0,6
1
160
0,4
120
0,2
80
40
0
106
1000
500
500
1000
1500
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
950
0.71
1.09
76
A
2
1005
0.60
0.94
75
A
3
1080
0.42
0.71
73
A
4
1120
0.31
0.60
74
B
1
845
0.60
1.10
73
B
2
915
0.53
0.97
73
B
3
1025
0.38
0.73
72
B
4
1085
0.29
0.58
73
C
1
845
0.60
1.90
73
C
2
915
0.53
1.68
73
C
3
1025
0.38
1.27
72
C
4
1085
0.29
1.01
73
A
1,4
360
3
D1)/D2)
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
Curves
400
-40 to +40
-40 to +40
-40 to +40
1500
2000
2500
[CFM]
[m3/h]
General information
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Centrifugal fan
kg
R6D 310-CG07 -01
12.5
Inlet nozzle
Flange
31010-2-4013
10310-2-4017
View without flange
251
163,5±2
128
AC centrifugal, forward
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
View with flange
61-2
6x60˚
4x90˚
Accessories
Ø257
Ø374
800
Ø327
Ø315
M6
Ø9
Z
Brass lead tips
26±1
4,5
Ø100
203±1
Ø115±0,3
View Z
Electrical connections
6x60˚
Ø3
50
±1
Housing width
Ø350±1
Ø374
Depth of screw
max. 12 mm
Scroll housing used:
Ø9
184
Mounting dimensions
249
4x90˚
186
30
˚
214
229
200
28
107
Inlet nozzles
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
30˚
Ø 130
˚
30
30˚
˚
30
246
18
30˚ 30˚
0
10
30˚
264
5
176
Ø
65
˚
25˚
283
30˚
11
303
Ø
325
349
Ø7
AC centrifugal fans
single inlet, Ø 310
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Min. back pressure
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
1050
970
970
1.11
0.99
0.99
1.91
1.80
3,12
—
—
—
200
170
170
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 310 (2)
M6D 110-IA
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
2
[Pa]
[in H O]
4
1,6
400
3
3
1,2
320
2
B
C
280
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1050
1,11
1,91
82
A
2
1080
0,92
1,70
80
A
3
1115
0,71
1,48
78
A
4
1145
0,51
1,32
76
B
1
970
0,99
1,80
80
B
2
1025
0,84
1,65
79
B
3
1075
0,65
1,37
77
B
4
1120
0,45
1,12
75
C
1
970
0,99
3,12
80
C
2
1025
0,84
2,86
79
C
3
1075
0,65
2,37
77
C
4
1120
0,45
1,94
75
A
1,4
360
D1)/D2)
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
Curves
4
-40 to +40
-40 to +40
-40 to +40
200
0,8
240
1,0
2
1
160
0,6
1
0,4
120
40
0,2
80
0
500
500
108
1000
1000
1500
1500
2000
2500
2000
3000
3500
[CFM]
[m3/h]
General information
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Centrifugal fan
kg
R6D 310-CI05 -01
15.0
Inlet nozzle
Flange
31010-2-4013
10310-2-4017
View without flange
251
163,5±2
128
AC centrifugal, forward
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
View with flange
61-2
6x60˚
4x90˚
Accessories
Ø257
Ø374
800
Ø327
Ø315
M6
Ø9
Z
Brass lead tips
26±1
4,5
Ø100
203±1
Ø115±0,3
View Z
Electrical connections
6x60˚
Ø3
50
±1
Housing width
Ø350±1
Ø374
Depth of screw
max. 12 mm
Scroll housing used:
Ø9
184
Mounting dimensions
249
4x90˚
186
30
˚
214
229
200
28
109
Inlet nozzles
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
30˚
Ø 130
˚
30
30˚
˚
30
246
18
30˚ 30˚
0
10
30˚
264
5
176
Ø
65
˚
25˚
283
30˚
11
303
Ø
325
349
Ø7
AC centrifugal fans
single inlet, Ø 310
subject to alterations
Min. back pressure
Perm. amp. temp.
Electr. connection
A
Capacitor
M6E 110-IA
Max. current draw (1)
R6E 310
Max. power input (1)
Motor
Speed (1)
Type
Frequency
Nominal data
Nominal voltage
Curve
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 127
60
950
1.00
4.47
16.0/500
100
1~ 230
2
[Pa]
1,6 [in H O]
1,4
4
360
1,2
320
3
280
160
0,8
2
0,6
200
1,0
A
240
0,4
120
1
0,2
80
40
0
500
500
110
A2a)
(1) Nominal data in operating point with maximum load
Curves
400
-40 to +50
1000
1000
1500
1500
2000
2500
2000
3000
3500
[CFM]
[m3/h]
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
950
1.00
4.47
80
A
2
1010
0.93
4.11
79
A
3
1060
0.85
3.70
78
A
4
1110
0.72
3.15
76
General information
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Centrifugal fan
kg
R6E 310-CI01 -01
15.0
Inlet nozzle
Flange
31010-2-4013
10310-2-4017
View without flange
251
163,5±2
128
AC centrifugal, forward
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
View with flange
61-2
6x60˚
4x90˚
Accessories
Ø257
Ø374
800
Ø327
Ø315
M6
Ø9
Z
Brass lead tips
26±1
4,5
Ø100
203±1
Ø115±0,3
Ø350±1
Ø374
View Z
Electrical connections
6x60˚
Ø3
50
±1
Housing width
Depth of screw
max. 12 mm
Scroll housing used:
Ø9
184
Mounting dimensions
249
4x90˚
186
30
˚
214
229
200
28
111
Inlet nozzles
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
30˚
Ø 130
˚
30
30˚
˚
30
246
18
30˚ 30˚
0
10
30˚
264
5
176
Ø
65
˚
25˚
283
30˚
11
303
Ø
325
349
Ø7
AC centrifugal fans
single inlet, Ø 355
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Min. back pressure
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
1550
1430
1430
6.00
5.30
5.30
9.00
9.80
16.95
—
—
—
350
305
305
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R4D 355 (2)
M4D 138-LA
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
4,4
1000
4,0
2
[Pa]
4,8 [in H O]
1100
4
4
3
3,2
3,6
800
700
2,8
900
3
600
2,4
2
2
400
B
C
1,6
500
2,0
A
1
1
0,8
1,2
200
100
0,4
300
0
1000
1000
112
2000
2000
3000
4000
3000
4000
5000
6000
7000
[CFM]
[m3/h]
D1)/D2)
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
Curves
1200
-40 to +40
-40 to +40
-40 to +40
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
1550
6.00
9.00
97
A
2
1600
5.18
7.90
95
A
3
1650
4.17
6.54
93
A
4
1700
3.08
5.21
90
B
1
1430
5.30
9.80
95
B
2
1500
4.84
8.70
94
B
3
1570
3.92
7.04
92
B
4
1650
2.90
5.34
90
C
1
1430
5.30
16.95
95
C
2
1500
4.84
15.07
94
C
3
1570
3.92
12.20
92
C
4
1650
2.90
9.25
90
General information
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Centrifugal fan
kg
R4D 355-CM15 -01
28.0
Inlet nozzle
Flange
35510-2-4013
38355-2-4017
View without flange
280
195±2
143
View with flange
70-2
6x60˚
Ø9
Accessories
Ø289
Ø413
Ø372
Ø355
M10
8x45˚
1000
AC centrifugal, forward
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
Z
5
Ø140
Ø162±0,3
90
6x60˚
Ø3
Brass lead tips
View Z
Ø390±1
Ø413
Electrical connections
228±1
Housing width
±1
42±1
Depth of screw
max. 18 mm
Scroll housing used:
30
˚
65
˚
196
207
222
238
113
Inlet nozzles
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
30˚
30˚ 30˚
256
274
˚
30
30
˚
30˚
294
18
25˚
315
30˚
30˚
338
Ø9
280
362
389
203
AC centrifugal fans
single inlet, Ø 355
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Min. back pressure
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
890
770
770
1.41
1.10
1.10
2.25
2.23
3.86
—
—
—
150
115
115
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharge holes: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 355 (2)
M6D 138-HF
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
2
[in H O]
[Pa]
360
1,8
1,6
400
4
3
1,4
440
4
A
3
n
[rpm]
P1
[kW]
I
[A]
LwA
[dB(A)]
A
1
890
1.41
2.25
83
A
2
940
1.27
2.01
82
A
3
1020
1.04
1.64
79
A
4
1090
0.72
1.21
77
B
1
770
1.10
2.23
79
B
2
850
1.03
2.03
78
B
3
950
0.88
1.70
77
B
4
1040
0.66
1.28
76
C
1
770
1.10
3.86
79
C
2
850
1.03
3.52
78
C
3
950
0.88
2.95
77
C
4
1040
0.66
2.22
76
1,2
320
D1)/D2)
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
Curves
480
-40 to +45
-40 to +45
-40 to +45
280
160
1,0
2
0,8
200
2
0,6
240
B
C
1
120
0,4
1
40
0,2
80
0
500
1000
114
1500
1000
2000
2000
3000
[CFM]
4000
[m3/h]
General information
Motor protection: Design with thermal overload protector
Cable exit: Diagonal
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Centrifugal fan
kg
R6D 355-CK05 -01
25.0
Inlet nozzle
Flange
35510-2-4013
38355-2-4017
View without flange
280
195±2
143
View with flange
70-2
6x60˚
Ø9
Accessories
Ø289
Ø413
Ø372
Ø355
M10
8x45˚
1000
AC centrifugal, forward
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
Z
5
Ø140
Ø162±0,3
90
6x60˚
Ø3
Brass lead tips
View Z
Ø390±1
Ø413
Electrical connections
228±1
Housing width
±1
42±1
Depth of screw
max. 18 mm
Scroll housing used:
30
˚
65
˚
196
207
222
238
115
Inlet nozzles
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
30˚
30˚ 30˚
256
274
˚
30
30
˚
30˚
294
18
25˚
315
30˚
30˚
338
Ø9
280
362
389
203
AC centrifugal fans
single inlet, Ø 400
Frequency
Speed (1)
Max. power input (1)
Max. current draw (1)
Capacitor
Min. back pressure
Perm. amp. temp.
Electr. connection
VAC
Hz
rpm
kW
A
μF/VDB
Pa
°C
p. 127
3~ 480 Y
3~ 400 Y
3~ 230 Δ
60
60
60
1030
950
950
2.94
2.58
2.58
4.90
5.15
8.90
—
—
—
300
255
255
Curve
Nominal voltage
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20 (in accordance with EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
Motor
R6D 400 (2)
M6D 138-LA
A
B
C
subject to alterations
(1) Nominal data in operating point with maximum load
2
[Pa]
[in H O]
2,8
4
4
2,4
640
320
2,0
B
C
1,6
400
2
2
1,2
480
1
1
0,8
240
0,4
160
80
0
500
1000
116
1000
2000
1500
2000
3000
2500
4000
3000
5000
3500
[CFM]
6000
[m3/h]
P1
[kW]
I
[A]
LwA
[dB(A)]
1
1030
2.94
4.90
89
A
2
1060
2.58
4.55
88
A
3
1090
2.12
3.95
85
A
4
1130
1.54
3.31
83
B
1
950
2.58
5.15
87
B
2
990
2.30
4.60
85
B
3
1040
1.94
3.95
84
B
4
1090
1.43
3.12
82
C
1
950
2.58
8.90
87
C
2
990
2.30
7.97
85
C
3
1040
1.94
6.85
84
C
4
1090
1.43
5.41
82
A
3
n
[rpm]
A
3
560
D1)/D2)
(2) 230 VAC Δ / 400 VAC Y / 480 VAC Y
Curves
720
-40 to +60
-40 to +60
-40 to +60
General information
Motor protection: Design with thermal overload protector
Cable exit: Lateral
Protection class: I (in accordance with EN 61800-5-1)
Product conforming to standard: CE
Approvals: UL, VDE (in accordance with EN 60034)
Centrifugal fan
kg
R6D 400-CM05 -01
29.0
Inlet nozzle
Flange
40010-2-4013
38400-2-4017
View without flange
307
215±2
163
View with flange
78-2
6x60˚
Ø9
Accessories
Ø325
Ø456
Ø414
Ø400
M10
8x45˚
1000
AC centrifugal, forward
Mass of
centrifugal fan
AC centrifugal, backward
AC axial fans
–
–
–
–
–
Z
4
Ø140
Ø162±0,3
30
6x60˚
Ø4
Brass lead tips
View Z
Ø430±1
Ø456
Electrical connections
255±1
Housing width
±1
42±1
Depth of screw
max. 18 mm
Scroll housing used:
30
˚
65
˚
220
233
250
268
117
Inlet nozzles
p. 121
Motor protection
p. 122 f.
Electr. connections
p. 127
Representatives
30˚
30˚ 30˚
288
308
˚
30
30
˚
30˚
331
20
25˚
355
30˚
30˚
380
Ø9
316
408
437
228
118
Electrical connections
Accessories
AC centrifugal, forward
AC centrifugal, backward
120
Guard grilles
121
Motor protection switch
122
Star-delta switch / repair switch
125
119
AC axial fans
Inlet nozzles
Representatives
General information
Accessories
Inlet nozzles
o
Øk
– Material: Galvanised sheet steel
r1
Øs
Øu
Øm
Øn
r3
r2
q
t
Inlet nozzles for backward curved centrifugal fans
Part no.
Size (1)
63045-2-4013
450
(A)
63072-2-4013
500
(A)
63071-2-4013
560
630
63070-2-4013
subject to alterations
k
m
n
o
q
r1
r2
r3
s
t
u
450.0
289.0
284.5
75.0
1.5
28.0
87.0
49.0
425.0
6x9
360.0
470.0
342.0
337.0
75.0
2.0
28.0
87.0
55.0
445.0
6x9
412.0
(A)
515.0
385.0
380.0
82.0
2.0
30.0
95.0
60.0
490.0
6x9
461.0
(A)
634.0
433.0
427.0
98.5
2.0
37.0
114.0
72.0
600.0
6x10.5 525.0
(1) Size with key for impeller material: (A) = aluminium
Air flow measurement:
The differential pressure approach compares the static pressure before the
inlet nozzle with the static pressure inside the inlet nozzle. Air flow can be
calculated on the basis of the differential pressure (difference in pressure of
the static pressures) in keeping with the following equation:
V = k . ΔpW
D
0,5xD
V in [m3/h] and ΔpW in [Pa]
If constant air flow control is used, then the nozzle pressure has to be kept
constant:
ΔpW = V2 : k2
k takes into account the specific nozzle characteristics.
1 or 4 pressure measuring points are spaced along the circumference of
the inlet nozzle. Connection on the customer side is accomplished via a
premounted T tube connector. This tube connector is suited for pneumatic
hoses with an internal diameter of 4 mm.
Inlet nozzles with measuring device to determine air flow for backward curved centrifugal fans
Part no. with 1 nozzle
Part no. with 4 nozzles (piezometer ring)
Size
k-value
For dimensions, see above
64015-2-4013
64005-2-4013
450
214
63045-2-4013
64025-2-4013
64002-2-4013
500
283
63072-2-4013
64030-2-4013
64001-2-4013
560
350
63071-2-4013
64040-2-4013
64000-2-4013
630
480
63070-2-4013
subject to alterations
120
General information
Inlet nozzles, guard grilles
f
– Material: Galvanised sheet steel
(2
87
Øu
Øb
Øa
c
AC axial fans
r
)
AC centrifugal, backward
e
d
Inlet nozzles for forward curved centrifugal fans
Part no.
Size
25010-2-4013
250(1)
28010-2-4013
280(1)
31010-2-4013
b
c
d
e
f
r
300.0
193.0
285.0
51.5
6x7
1.50
27.3
—
336.0
228.0
315.0
58.5
6x7
1.50
36.5
296.0
310(1)
374.0
257.0
350.0
62.5
6x9
1.50
39.5
327.0
35510-2-4013
(1)
355
413.0
289.0
390.0
71.5
6x9
1.50
43.5
372.0
40010-2-4013
400(1)
456.0
325.0
430.0
79.5
6x9
1.50
45.5
414.0
u
(1) 6 drilled holes staggered by 60°
AC centrifugal, forward
subject to alterations
a
4x
90
˚
– Material: Steel wire, plastic coated, silvermetallic gloss
Ød
Accessories
a
b
Electrical connections
e
Guard grille for backward curved centrifugal fans (in accordance with EN 294)
Part no.
Size
a
b
d
e
78136-2-4039
450
425.0
8.5
350.0
3.8
78139-2-4039
500
445.0
8.5
410.0
3.8
78137-2-4039
560
490.0
8.5
430.0
3.8
78138-2-4039
630
600.0
8.5
490.0
3.8
121
Representatives
subject to alterations
Motor protection switch (three-phase)
for assembly inside a cabinet
Current draw
Mass
Type
Frequency
Nominal data
Nominal voltage
– Technical features: Input for TOP
VAC
Hz
A
kg
Auxiliary contactor
TPD 250-AB01 -01
3~
400
50/60
25.0
0.3
without auxiliary contactor
TPD 250-AB01 -02
3~
400
50/60
25.0
0.3
with break contact
TPD 250-AB01 -03
3~
400
50/60
25.0
0.3
with make contact
subject to alterations
68
– Electr. connection:
7
122
54,5
66,5
General information
Motor protection switch (single-phase)
for assembly inside a cabinet
Hz
A
kg
AC centrifugal, backward
Mass
VAC
Auxiliary contactor
TPE 100-AB01 -01
1~
230
50/60
10.0
0.3
without auxiliary contactor
TPE 100-AB01 -02
1~
230
50/60
10.0
0.3
with break contact
TPE 100-AB01 -03
1~
230
50/60
10.0
0.3
with make contact
AC centrifugal, forward
Current draw
subject to alterations
52,5
Accessories
45
103
46
– Electr. connection:
Electrical connections
70
78
123
Representatives
Type
Frequency
Nominal data
Nominal voltage
AC axial fans
– Technical features: Input for TOP
Motor protection switch (single-phase and three-phase)
for wall assembly
Current draw
Mass
Type
Frequency
Nominal data
Nominal voltage
– Technical features: Input for TOP
– Type of protection: IP 55
VAC
Hz
A
kg
Auxiliary contactor
TPD 250-AA01 -01
3~
400
50/60
25.0
0.6
without auxiliary contactor
TPD 250-AA01 -02
3~
400
50/60
25.0
0.6
with break contact
TPD 250-AA01 -03
3~
400
50/60
25.0
0.6
with make contact
TPE 100-AA01 -01
1~
230
50/60
10.0
0.6
without auxiliary contactor
TPE 100-AA01 -02
1~
230
50/60
10.0
0.6
with break contact
TPE 100-AA01 -03
1~
230
50/60
10.0
0.6
with make contact
subject to alterations
92
80
141
79
38
124
– Electr. connection, three-phase:
– Electr. connection, single-phase:
20
General information
Star-delta switch / repair switch
Third-party accessories from Möller Electric GmbH
AC axial fans
More information: www.moeller.net
AC centrifugal, backward
for wall installation
Star-delta switch (available from Möller Electric GmbH)
Designation
Installation
T0-4-8410/I1
Wall installation
T0-4-8410/E
Cabinet installation
subject to alterations
AC centrifugal, forward
More information: www.moeller.net
Accessories
for wall installation
Repair switch, lockable (available from Möller Electric GmbH)
Designation
Installation
T0-2-8900/I1/SVB-SW
Wall installation
T0-2-8900/EA/SVB-SW
Cabinet installation
125
Representatives
Electrical connections
subject to alterations
Electrical connections
Fans with terminal box
Fans (1~ 230 VAC power line)
A2b) Single-phase capacitor motor
with connection for external TOP
U1 = blue
U2 = black
Z = brown
= green/yellow
C
U1 Z U2
L
TOP TOP
N PE
Fans
with terminal box
Fans, 1-speed (3~ 230 VAC power line)
Fans, 1-speed (3~ 400 or 480 VAC power line)
F1b) Delta connection (3~ 230 VAC power line)
with TOP
F2b) Star connection (3~ 400 or 480 VAC power line)
with TOP
U1 V1 W1 W2 U2 V2 TOP TOP
L1 L2 L3
Fans
with terminal box
126
PE
U1
U2
V1
V2
W1
W2
=
=
=
=
=
=
=
black
green
blue
white
brown
yellow
green/yellow
U1 V1 W1 W2 U2 V2 TOP TOP
L1 L2 L3
Fans
with terminal box
PE
U1
U2
V1
V2
W1
W2
=
=
=
=
=
=
=
black
green
blue
white
brown
yellow
green/yellow
General information
AC axial fans
AC centrifugal, backward
Fans with cable exit
Fans (1~ 230 VAC power line)
A2a) Single-phase capacitor motor
with connection for external TOP
TOP
U2 Z
U1
U1 = blue
U2 = black
Z = brown
= green/yellow
Fans, 1-speed (3~ 230 VAC power line)
Fans, 1-speed (3~ 400 or 480 VAC power line)
D1) Delta connection (3~ 230 VAC power line)
with TOP
D2) Star connection (3~ 400 or 480 VAC power line)
with TOP
L1
PE
L2
U1
V1
U2
V2
L3
W1
W2
TOP
U1
U2
V1
V2
W1
W2
=
=
=
=
=
=
=
black
green
blue
white
brown
yellow
green/yellow
L1
PE
L2
U1
V1
W1
U2
V2
W2
L3
TOP
U1
U2
V1
V2
W1
W2
=
=
=
=
=
=
=
AC centrifugal, forward
C
black
green
blue
white
brown
yellow
green/yellow
Accessories
N
PE
L
127
Representatives
Electrical connections
Direction of rotation is reversed by swapping two line phases.
fan agent
compact fan agent
ebm-papst representatives & subsidiaries
motor specialist
motor agent
Germany
ebm-papst
Mulfingen GmbH & Co. KG
ebm-papst
St. Georgen GmbH & Co. KG
ebm-papst
Landshut GmbH
Bachmühle 2
D-74673 Mulfingen
Phone +49 (0) 79 38 / 81-0
Fax +49 (0) 79 38 / 81-110
[email protected]
Hermann-Papst-Straße 1
D-78112 St. Georgen
Phone +49 (0) 77 24 / 81-0
Fax +49 (0) 77 24 / 81-13 09
[email protected]
Hofmark-Aich-Straße 25
D-84030 Landshut
Phone +49 (0) 8 71 / 707-0
Fax +49 (0) 8 71 / 707-465
[email protected]
www.ebmpapst.com
www.ebmpapst.com
www.ebmpapst.com
Agencies
Berlin
Dipl.-Ing. (TH) Jens Duchow
Händelstraße 7
D-16341 Panketal
Phone +49 (0) 30 / 94 41 49 62
Fax +49 (0) 30 / 94 41 49 63
[email protected]
Bielefeld
Dipl.-Ing. (FH) Wolf-Jürgen Weber
Niehausweg 13
D-33739 Bielefeld
Phone +49 (0) 52 06 / 9 17 32 31
Fax +49 (0) 52 06 / 9 17 32 35
[email protected]
Dortmund
Dipl.-Ing. (FH) Hans-Joachim Pundt
Auf den Steinern 3
D-59519 Möhnesee-Völlinghausen
Phone +49 (0) 29 25 / 80 04 07
Fax +49 (0) 29 25 / 80 04 08
[email protected]
Frankfurt
Dipl.-Ing. Christian Kleffmann
Dr.-Hermann-Krause-Straße 23
D-63452 Hanau
Phone +49 (0) 61 81 / 18 98 12
Fax +49 (0) 61 81 / 18 98 13
[email protected]
Halle
Dipl.-Ing. (TU) Michael Hanning
Lerchenweg 4
D-06120 Lieskau
Phone +49 (0) 3 45 / 5 51 24 56
Fax +49 (0) 3 45 / 5 51 24 57
[email protected]
Hamburg
Ingenieurbüro Breuell GmbH
Ing. Dirk Kahl
Elektroingenieur
Grützmühlenweg 40
D-22339 Hamburg
Phone +49 (0) 40 / 53 80 92 55
Fax +49 (0) 40 / 53 80 92 84
[email protected]
128
Kassel
Dipl.-Ing. (FH) Ralph Brück
Hoherainstraße 38
D-35075 Gladenbach
Phone +49 (0) 64 62 / 40 71 10
Fax +49 (0) 64 62 / 40 71 11
[email protected]
Koblenz
Winfried Schaefer
Hinter der Kirch 10
D-56767 Uersfeld
Phone +49 (0) 26 57 / 16 96
Fax +49 (0) 26 57 / 16 76
[email protected]
Munich
Dipl.-Wirtsch.-Ing. (FH) Jens Peter
Steinbergweg 6
D-82285 Hattenhofen
Phone +49 (0) 81 45 / 80 92 25
Fax +49 (0) 81 45 / 80 92 26
[email protected]
Nuremberg
Friedrich Klein
Adlerstraße 49/1
D-73540 Heubach
Phone +49 (0) 71 73 / 49 83
Fax +49 (0) 71 73 / 80 53
[email protected]
Offenburg
Dipl.-Ing. (FH) Ralf Braun
Hubeneck 21
D-77704 Oberkirch
Phone +49 (0) 78 02 / 98 22 52
Fax +49 (0) 78 02 / 98 22 53
[email protected]
Stuttgart
Dipl.-Ing. (FH) Rudi Weinmann
Hindenburgstraße 100/1
D-73207 Plochingen
Phone +49 (0) 71 53 / 92 89 80
Fax +49 (0) 71 53 / 92 89 81
[email protected]
Ulm
Günter Wilhelm
Allgäuer Straße 7
D-89269 Vöhringen
Phone +49 (0) 73 06 / 92 46 08
Fax +49 (0) 73 06 / 92 46 48
[email protected]
Distributors
Frankfurt
R.E.D. Handelsgesellschaft mbH
Gutenbergstraße 3
D-63110 Rodgau - Jügesheim
Phone +49 (0) 61 06 / 84 10
Fax +49 (0) 61 06 / 84 11 11
[email protected]
www.red-elektromechanik.de
Hamburg
Breuell + Hilgenfeldt GmbH
Grützmühlenweg 40
D-22339 Hamburg
Phone +49 (0) 40 / 53 80 92 20
Fax +49 (0) 40 / 53 80 92 84
[email protected]
Munich
A. Schweiger GmbH
Ohmstraße 1
D-82054 Sauerlach
Phone +49 (0) 81 04 / 8 97 0
Fax +49 (0) 81 04 / 8 97 90
[email protected]
www.schweiger-gmbh.com
(1 to 5 pieces)
North
Breuell + Hilgenfeldt GmbH
Grützmühlenweg 40
D-22339 Hamburg
Phone +49 (0) 40 / 53 80 92 20
Fax +49 (0) 40 / 53 80 92 84
[email protected]
South
HDS Ventilatoren Vertriebs GmbH
Glaswiesenstraße 1
D-74677 Dörzbach
Phone +49 (0) 79 37 / 80 29 68
Fax +49 (0) 79 37 / 80 25 78
[email protected]
General information
Croatia
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 / 1 / 87 22 190
Fax +36 / 1 / 87 22 194
[email protected]
www.ebmpapst.hu
Denmark
Jenk A/S
Vallensbækvej 21
DK-2605 Brøndby
Phone +45 / 43 / 63 11 11
Fax +45 / 43 / 63 05 05
[email protected]
www.jenk.dk
Iceland
RJ Engineers
Stangarhyl 1A
IS-110 Reykjavik
Phone +354 / 567 80 30
Fax +354 / 567 80 15
[email protected]
www.rj.is
Estonia
ebm-papst Oy Eesti Filiaal
Kadaka tee 3
EST-10621 Tallinn
Phone +372 / 65 56 / 978
Fax +372 / 65 56 / 979
www.ebmpapst.ee
Ireland
ebm-papst Limited
Portlaoise Business & Technology Park
Mountrath Road
IRL-Portlaoise, Co. Laois
Phone +353 / 57 86 / 643 43
Fax +353 / 57 86 / 643 46
[email protected]
www.ebmpapst.ie
Finland
ebm-papst Oy
Puistotie 1
FIN-02760 Espoo
Phone +358 / 9 / 88 70 22 0
Fax +358 / 9 / 88 70 22 13
[email protected]
www.ebmpapst.fi
France
ebm-papst SARL
ZI Nord - rue A. Mohler
BP 62
F-67212 Obernai-Cedex
Phone +33 / 820 326 266
Fax +33 / 3 / 88 67 38 83
[email protected]
www.ebmpapst.fr
AC centrifugal, backward
AC axial fans
Bulgaria
ebm-papst Romania S.R.L.
Str. Tirnavei Nr. 20
RO-500327 Brasov
Phone +40 / 268 / 312 805
Fax +40 / 268 / 312 805
[email protected]
Hungary
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 / 1 / 87 22 190
Fax +36 / 1 / 87 22 194
[email protected]
www.ebmpapst.hu
AC centrifugal, forward
Belgium
VIBO Benelux B. V.
Sales office Belgium-Luxemburg
Romeinsestraat 6/0101
Research Park Haasrode
B-3001 Heverlee-Leuven
Phone +32 / 16 / 39 62 00
Fax +32 / 16 / 39 62 20
[email protected]
www.vibobenelux.com
Czech Republic / Slovakia
ebm-papst CZ s.r.o.
Krátká 379
CZ-66461 Rajhradice u Brna
Phone +420 / 547 / 232 617
Fax +420 / 547 / 232 622
[email protected]
www.ebmpapst.cz
Accessories
Belarus
ebm-papst Bel AgmbH
P.O. Box 117
BY-220138 Minsk
Phone +375 / 17 / 385 15 56
Fax +375 / 17 / 385 15 56
[email protected]
www.ebmpapst.by
Greece
Helcoma
Th. Rotas & Co OE
Davaki 65
GR-17672 Kallithea-Attiki
Phone +30 / 210 / 951 37 05
Fax +30 / 210 / 951 34 90
[email protected]
www.helcoma.gr
Italy
ebm-papst Srl
Via Cornaggia 108
I-22076 Mozzate (Co)
Phone +39 / 03 31 / 83 62 01
Fax +39 / 03 31 / 82 15 10
[email protected]
www.ebmpapst.it
Electrical connections
Austria
ebm-papst Motoren & Ventilatoren GmbH
Westbahnstraße 5
A-4490 St. Florian
Phone +43 / 72 24 / 66 01 10
Fax +43 / 72 24 / 66 01 120
[email protected]
www.ebmpapst.at
Cyprus
MATERO LTD
37, St. Kyriakides Avenue
P.O. Box 51744
CY-3080 Limassol
Phone +357 / 25 / 87 00 30
Fax +357 / 25 / 38 13 66
[email protected]
www.matero.com.cy
Macedonia
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 / 1 / 87 22 190
Fax +36 / 1 / 87 22 194
[email protected]
www.ebmpapst.hu
129
Representatives
Europe
fan agent
compact fan agent
ebm-papst representatives & subsidiaries
motor specialist
motor agent
Netherlands
VIBO Benelux B. V.
Engelseweg 127
Postbus 230
NL-5705 AC Helmond
Phone +31 / 4 92 / 50 29 00
Fax +31 / 4 92 / 50 29 50
[email protected]
www.vibobenelux.com
Norway
ebm-papst AS
P.B. 173 Holmlia
N-1203 Oslo
Phone +47 / 22 / 76 33 40
Fax +47 / 22 / 61 91 73
[email protected]
www.ebmpapst.no
Poland
ebm-papst Polska Sp. z o.o.
ul. Annopol 4A
PL-03236 Warszawa
Phone +48 / 22 / 675 78 19
Fax +48 / 22 / 676 95 87
[email protected]
www.ebmpapst.pl
Portugal
ebm-papst (Portugal), Lda.
Av. Marechal Gomes da Costa, 35 e
Rua Conselheiro Emidio Navarro
P-1800-255 Lisboa
Phone +351 / 218 / 394 880
Fax +351 / 218 / 394 759
[email protected]
www.ebmpapst.pt
Romania
ebm-papst Romania S.R.L.
Str. Tirnavei Nr. 20
RO-500327 Brasov
Phone +40 / 268 / 312 805
Fax +40 / 268 / 312 805
[email protected]
130
Russia
ebm-papst Ural GmbH
Posadskaja-Strasse, 23(E), 3
RU-620102 Ekaterinburg
Phone +7 / 343 / 233 80 00
Fax +7 / 343 / 233 77 88
[email protected]
www.ebmpapst.ur.ru
Switzerland
ebm-papst AG
Rütisbergstrasse 1
CH-8156 Oberhasli
Phone +41 / 44 / 732 20 70
Fax +41 / 44 / 732 20 77
[email protected]
www.ebmpapst.ch
ebm-papst Rus GmbH
Nizhegorodskaya 32, str. 15 office 420
RU-109029 Moskau
Phone +7 / 495 / 671 53 93
Fax +7 / 495 / 671 53 95
[email protected]
www.ebmpapst.ru
Turkey
Akantel Elektronik San. Tic. LTD. Sti.
Atatürk Organize Sanayi
Bölgesi 10007 SK. No.:6
TR-35620 Cigli-Izmir
Phone +90 / 232 / 328 20 90
Fax +90 / 232 / 328 02 70
[email protected]
www.ebmpapst.com.tr
Serbia & Montenegro
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 / 1 / 87 22 190
Fax +36 / 1 / 87 22 194
[email protected]
www.ebmpapst.hu
Spain
ebm-papst Ibérica S.L.
Avda. del Sistema Solar, 29
E-28830 San Fernando de Henares (Madrid)
Phone +34 / 91 / 678 08 94
Fax +34 / 91 / 678 15 30
[email protected]
Sweden
ebm-papst AB
Äggelundavägen 2
S-17562 Järfälla
Phone +46 / 8 / 761 94 00
Fax +46 / 8 / 36 23 06
[email protected]
www.ebmpapst.se
Ukraine
ebm-papst Ukraine LLC
Lepse Boulevard, 4, Building 47
UA-03067 Kiev
Phone +38 / 044 / 206 30 91
Fax +38 / 044 / 206 30 91
[email protected]
www.ebmpapst.ua
United Kingdom
ebm-papst UK Ltd.
Chelmsford Business Park
GB-Chelmsford Essex CM2 5EZ
Phone +44 / 12 45 / 46 85 55
Fax +44 / 12 45 / 46 63 36
[email protected]
www.ebmpapst.co.uk
ebm-papst Automotive & Drives (UK) Ltd.
The Smithy
Fidlers Lane, East Ilsley
GB-Berkshire RG20 7LG
Phone +44 / 16 35 / 28 11 11
Fax +44 / 16 35 / 28 11 61
A&[email protected]
www.ebmpapst-ad.com
General information
ebm-papst Automotive & Drives, Inc.
3200 Greenfield, Suite 255
USA-Dearborn, MI 48120
Phone +1 / 313 / 406 80 80
Fax +1 / 313 / 406 80 81
[email protected]
www.ebmpapst-automotive.us
AC centrifugal, backward
AC axial fans
Brasil
ebm-papst Motores Ventiladores Ltda.
Av. José Giorgi, 301 Galpões B6+B7
Condominio Logical Center
BR-06707-100 Cotia - São Paulo
Phone +55 /11 / 31 64 89 00
Fax +55 /11 / 47 77 14 56
[email protected]
www.ebmpapst.com.br
Africa
South Africa
ebm-papst South Africa (Pty) Ltd.
P.O. Box 3124
1119 Yacht Avenue
ZA-2040 Honeydew
Phone +27 / 11 / 794 34 34
Fax +27 / 11 / 794 50 20
[email protected]
www.ebmpapst.co.za
AC centrifugal, forward
Argentina
ebm-papst de Argentina S.A.
Hernandarias 148 Lomas del Mirador
Pcia. de Buenos Aires (1752)
Phone +54 / 11 46 57 61 35
Fax +54 / 11 46 57 20 92
[email protected]
www.ebmpapst.com.ar
USA
ebm-papst Inc.
P.O. Box 4009
100 Hyde Road
USA-Farmington, CT 06034
Phone +1 / 860 / 674 15 15
Fax +1 / 860 / 674 85 36
[email protected]
www.ebmpapst.us
Accessories
Canada
ebm-papst Canada Inc.
1800 Ironstone Manor, Unit 2
CDN-Pickering, Ontario, L1W3J9
Phone +1 / 905 / 420 / 35 33
Fax +1 / 905 / 420 / 37 72
[email protected]
www.ebmpapst.ca
Electrical connections
Mexico
ebm Industrial S.de R.L. de C.V.
Paseo de Tamarindos 400-A-5to Piso
Col. Bosques de las Lomas
MEX-Mexico 05120, D.F.
Phone +52 / 55 / 33 00 51 44
Fax +52 / 55 / 33 00 52 43
[email protected]
www.ebmpapst.com.mx
131
Representatives
America
fan agent
compact fan agent
ebm-papst representatives & subsidiaries
motor specialist
motor agent
Asia
China
ebm-papst Ventilator (Shanghai) Co., Ltd.
No. 418, Huajing Road
WaiGaoQiao Free Trade Zone
No. 2001, Yang Gao (N) Road
VRC-200131 Shanghai, P.R. of China
Phone +86 / 21 / 50 46 01 83
Fax +86 / 21 / 50 46 11 19
[email protected]
www.ebmpapst.com.cn
Hong Kong
ebm-papst Ventilator (Shanghai) Co., Ltd.
Hong Kong Representative Office
Unit Nos. 13-15, 9/F, Technology Park
18 On Lai Street, Siu Lek Yuen, Shatin,
N.T. Hong Kong P.R. of China
Phone +852 / 21 45 / 86 78
Fax +852 / 21 45 / 76 78
[email protected]
India
ebm NADI International Pvt Ltd.
26/3, G.N.T. Road, Erukkencherry
IND-Chennai-600118
Phone +91 / 44 / 25 37 25 56
Fax +91 / 44 / 25 37 11 49
[email protected]
www.ebmnadi.com
Indonesia
ebm-papst Indonesia
Wisma Slipi Building 14th Floor, No. 1410
Jl. Letjend S. Parman Kav. 12
RI-Jakarta Barat 11480
Phone +62 / 21 / 53 66 19 01
Fax +62 / 21 / 53 66 19 05
[email protected]
Israel
Polak Bros. Import Agencies Ltd.
9 Hamefalsim Street
IL-Kiryat Arie, Petach-Tikva 49514
Phone +972 / 3 / 910 03 00
Fax +972 / 3 / 579 66 79
[email protected]
www.polak.co.il
132
Japan
ebm-papst Industries Japan K.K.
12 Floor, Benex S-3 Bldg.
3-20-8 Shinyokohama, Kohoku-ku
J-222-0033 Yokohama
Phone +81 / 45 / 470 / 57 51
Fax +81 / 45 / 470 / 57 52
[email protected]
www.ebmpapst.jp
Korea
ebm-papst Korea Co. Ltd.
6F, Trutec Bldg.
B 6-2, Digital Media City (DMC)
Sangam-Dong, Mapo-Gu
ROK-Seoul 121-270
Phone +82 / 2 / 36 62 / 13 24
Fax +82 / 2 / 36 62 / 13 26
[email protected]
www.ebmpapst.co.kr
Malaysia
ebm-papst Malaysia
Representative Office
Block F1, 9A-4, Jln PJU 1/42
Dataran Prima
MAL-47301 Petaling Jaya
Phone +60 / 3 / 78 06 54 40
Fax +60 / 3 / 78 06 54 41
[email protected]
Singapore
ebm-papst SEA Pte. Ltd.
No. 23 Ubi Road 4
#06-00 Olympia Industrial Building
SGP-Singapore 408620
Phone +65 / 65 51 37 89
Fax +65 / 68 42 84 39
[email protected]
Taiwan
ETECO Engineering & Trading Corp.
10F-I, No. 92, Teh-Wei Str.
RC-Tsow-Inn District, Kaohsiung
Phone +886 / 7 / 557 42 68
Fax +886 / 7 / 557 27 88
[email protected]
Thailand
ebm-papst Thailand Co., Ltd.
99/349 Na-Nakorn Bldg., 4th Floor
Chaeng Wattana Road, Thungsonghong,
THA-10210 Laksi, BKK
Phone +66 / 2 / 5 76 15 24
Fax +66 / 2 / 5 76 15 42
[email protected]
United Arab Emirates
ebm-papst Middle East FZE
PO Box 17755
Jebel Ali Free Zone / FZS1 / AP05
UAE-Dubai
Phone +971 / 4 / 886 08 26
Fax +971 / 4 / 886 08 27
[email protected]
www.ebmpapst.ae
Vietnam
ebm-papst Vietnam
Representative Office
Room #102, 25 Nguyen Van Thu Street
District 1
VN-Ho Chi Minh City
Phone +84 / 8 / 391 040 99
Fax +84 / 8 / 391 039 70
[email protected]
General information
AC axial fans
AC centrifugal, backward
Australia
Australia
ebm-papst A&NZ Pty Ltd.
10 Oxford Road
AUS-Laverton North, Victoria, 3026
Phone +61 / 3 / 83 25 64 00
Fax +61 / 3 / 83 25 64 64
[email protected]
www.ebmpapst.com.au
133
Representatives
Electrical connections
Accessories
AC centrifugal, forward
New Zealand
ebm-papst A&NZ Pty Ltd.
102 Henderson Valley Road
NZ-Henderson, Auckland 1230
Phone +64 / 9 / 837 18 84
Fax +64 / 9 / 837 18 99
[email protected]
www.ebmpapst.com.au
Notes
134
135
37765-7-8811 · RA-07/09-3’
Printed in Germany
ebm-papst
Mulfingen GmbH & Co. KG
Bachmühle 2
D-74673 Mulfingen, Germany
Phone +49 (0) 79 38 / 81-0
Fax +49 (0) 79 38 / 81-110
[email protected]
www.ebmpapst.com