P-511-544(V :1) P D104S M1 V ers ion : 1.0 T E C HNIC AL S P E C IF IC AT ION MODE L NO. : P D104S M1 T he content of this information is s ubject to be changed without notice. P leas e contact P V I or its agent for further information. C us tomer•s C onfirmation C us tomer Date FOR MORE INFORMATION: AZ DISPLAYS, INC. 75 COLUMBIA, ALISO VIEJO, CA 92656 Http://www.AZDISPLAYS.com By P V I•s C onfirmation C onfirmed B y P repared B y T he information contained herein is the exclus ive property of P rime V iew International C o., Ltd. and s hall not be dis tributed, reproduced, or dis clos ed in whole or in part without prior written permis s ion of P rime V iew International C o., Ltd. P age:1 V er:001 1/17 P-511-544(V:1) PD104SM1 Revision History Rev. Issued Date 0.1 Jul. 07, 2008 0.2 Sep. 19, 2008 Eng. ࣑ܦᙤ ࣑ܦᙤ 0.3 0.4 ࣑ܦᙤ ࣑ܦᙤ Oct. 16, 2008 Nov. 19, 2008 Revised Contents Preliminary Add weight of LCD module Add gamma voltage Modify 8. Block Diagram Modify 9.Interface Timing Update lamp current from 5.0mA(typ.) to 5.5mA(typ.) Brightness (min.) from 195(cd/m2) to 185(cd/m2) 7. Electrical Characteristics add IDD(typ.) = 260mA add Note 7-3ΚThe minimum life of CCFL = 20,000hrs Delete 7-3) Gamma correction voltage 1.0 Nov. 21, 2008 ࣑ܦᙤ 10. Optical Characteristics modify response time Tr(typ.)=10ms , Tr(max.)=15ms Tf(typ.)=15ms , Tf(max.)=25ms New The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:2 Ver:001 2/17 P-511-544(V:1) PD104SM1 TECHNICAL SPECIFICATION CONTENTS NO. ITEM PAGE 1 2 3 4 5 6 7 8 9 10 11 12 13 Cover Revision History Contents Application Features Mechanical Specifications Mechanical Drawing of TFT-LCD module Input / Output Terminals Absolute Maximum Ratings Electrical Characteristics Block Diagram Interface Timing Optical Characteristics 1 2 3 4 4 4 5 7 8 8 10 11 12 15 16 17 Handling Cautions Reliability Test Packing Diagram The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:3 Ver:001 3/17 P-511-544(V:1) PD104SM1 1. Application This data sheet applies to a color TFT LCD module, PD104SM1. PD104SM1 module applies to OA products, which require high quality flat panel display. If you must use in severe reliability environment, please don’t extend over PVI’s reliability test conditions. Prime View assume no responsibility for any damage resulting from the use of the device which dose not comply with the instructions and the precautions in these specification sheet. 2. Features . SVGA (800*600 pixels) resolution . Amorphous silicon TFT LCD panel with CCFL backlight . Pixel in stripe configuration . Thin and light weight . Display ColorsΚ262K colors . InterfaceΚLVDS 6 bit 3. Mechanical Specifications Parameter Screen Size Display Format Display Colors Active Area Pixel Pitch Pixel Configuration Outline Dimension Weight Back-light Surface treatment Display mode Gray scale inversion direction Specifications 10.4 (diagonal) 800ͪ(R,G,B)ͪ600 262K 211.2 (H)ͪ158.4 (V) 0.264(H)ͪ0.264(V) Stripe 236.0 (W)Ø176.9 (H)Ø5.6 (D) (typ.) 288²15 CCFL Anti-Glare(3H) Normally White 6 o’clock (ref to Note10-1) Unit inch dot mm mm mm g The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:4 Ver:001 4/17 P-511-544(V:1) PD104SM1 4. Mechanical Drawing of TFT-LCD Module The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:5 Ver:001 5/17 P-511-544(V:1) PD104SM1 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:6 Ver:001 6/17 P-511-544(V:1) PD104SM1 5. Input / Output Terminals 5-1) LVDS interface Connector typeΚHIROSE DF19K-20P-1H(56) Pin No 1 Symbol I/O Description VDD P Power Supply 2 VDD P Power Supply 3 GND P Ground 4 GND P Ground 5 IN0- I LVDS receiver negative signal channel 0 Note 5-1 6 IN0+ I LVDS receiver positive signal channel 0 Note 5-1 7 GND P Ground 8 IN1- I LVDS receiver negative signal channel 1 Note 5-1 9 IN1+ I LVDS receiver positive signal channel 1 Note 5-1 10 GND P Ground - 11 IN2- I LVDS receiver negative signal channel 2 Note 5-1 12 IN2+ I LVDS receiver positive signal channel 2 Note 5-1 13 GND P Ground - 14 CLK- I LVDS receiver negative signal clock Note 5-1 15 CLK+ I LVDS receiver positive signal clock Note 5-1 16 GND P Ground - 17 NC - No connection - 18 NC - - 19 GND P No connection Ground 20 GND P Ground - Remark - IΚinput pin PΚPower/GND Note 5-1ΚData mapping as followsΚ Figure 5-1 Input signal data mapping The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:7 Ver:001 7/17 P-511-544(V:1) PD104SM1 5-2) CN2 (CCFL connector) Symbol I/O Pin No 1 VL1 P 2 VL2 P Description CCFL power supply (high voltage) Remark Pink CCFL power supply (GND) White 6. Absolute Maximum Ratings: Ta=25к Parameters Symbol MIN. Power Voltage VDD -0.3 Input Voltage VIN -0.3 Operating Temperature TOP -20 Storage Temperature TST -30 Note 6-1ΚVIN represent IN0²-IN1²-IN2²-CLK² MAX. 5.0 5.0 70 80 Unit V V ʚ ʚ Remark Note 6-1 7. Electrical Characteristics Κ 7-1) LVDS Module Electrical CharacteristicsΚ Note 7-1 260 Note 7-2 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:8 Ver:001 8/17 P-511-544(V:1) PD104SM1 Figure 7-1 LVDS DC timing diagram Note 7-1ΚThe value may be different for different LCM. Note 7-2ΚTo test the current dissipation, using the “color bar” testing pattern shown as belowΚ Figure 7-2 Current dissipation testing pattern 7-2) Backlight Unit Note 7-6 Note 7-3ΚThe minimum life of CCFL = 20,000hrs Note 7-4ΚIn order to satisfy the quality of B/L, no matter use what kind of inverter, the output lamp current must between Min. and Max. to avoid the abnormal display image caused by B/L. Note 7-5ΚThe waveform of lamp driving voltage should be as closed to a perfect sine wave as possible. Note 7-6ΚThe” Max “ of “starting voltage ” means the minimum voltage of inverter to turn on the CCFL, and it should be applied to the lamp for more than 1 second to start up. Otherwise the lamp may not be turned on. The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:9 Ver:001 9/17 P-511-544(V:1) PD104SM1 8. Block Diagram PD104SM1 800 X 600(SVGA) The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:10 Ver:001 10/17 P-511-544(V:1) PD104SM1 9. Interface Timing 9-1) LVDS input timing VDD Figure 9-1 input signal data timing The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:11 Ver:001 11/17 P-511-544(V:1) PD104SM1 9-2) LVDS INTERFACE POWER ON/OFF VDD - VDD VDD Figure 9-2 Interface power on/off sequence 10. Optical Characteristics 10-1) Specification: Parameter Symbol Ӱ Horizontal Viewing Angle Vertical Ӱ(to 6 o’clock) Ӱ(to 12 o’clock) CR Condition CRЊ10 MIN. TYP. MAX. 55 65 - Ta=25к Unit Remarks deg 55 65 - deg 35 45 - deg 300 - 400 10 15 - Note 10-2 ms Note 10-3 Brightness L Ӱ=0° 185 230 15 25 - Luminance Uniformity U Ӱ=0° 70 80 - Contrast Ratio Response time Rise Tr Fall Tf White Chromaticity Red Chromaticity Green Chromaticity Blue Chromaticity NTSC Ӱ=0° 25к x 0.261 0.311 0.361 y 0.280 0.330 0.380 x 0.550 0.600 0.650 y x Backlight is on % x 0.097 0.147 0.197 y 0.065 0.115 0.165 - 50 - Note 10-6 Note 10-5 Note 10-4 0.250 0.300 0.350 0.517 0.567 0.617 (x,y) cd/ф Note 10-5 0.297 0.347 0.397 y Note 10-1 % Note 10-4 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:12 Ver:001 12/17 P-511-544(V:1) PD104SM1 Note 10-1ΚThe definitions of viewing angles are as follow Ә Ә Note 10-2ΚThe definition of contrast ratio CR = Luminance at White Pattern Luminance at Black Pattern Note 10-3ΚDefinition of Response Time Tr and Tf: W hite Black W hite 100% 90% Brightness 10% 0% Tr Tf Note 10-4ΚDefinition of color chromaticityΰCIE1931α Color coordinates measured at center point of LCD. The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:13 Ver:001 13/17 P-511-544(V:1) PD104SM1 Note 10-5ΚAll optical measurements shall be performed after backlight being turned-on for 5 minutes. The optical characteristics shall be measured in dark room. The measuring configuration shows as following figure. Photometer (TOPCON BM-5A or BM7 fast) 500 mm +/- 50 mm Field = 1° TFT-LCD module Optical characteristics measuring configuration Note 10-6ΚThe uniformity of LCD is defined as U= The Minimum Brightness of the 9 testing Points The Maximum Brightness of the 9 testing Points Luminance meterΚBM-7 fast (TOPCON) Measurement distanceΚ500 mm +/- 50 mm Ambient illuminationΚdark room Measuring directionΚPerpendicular to the surface of module The test pattern is white 1/6 2/6 2/6 1/6 1/6 2/6 2/6 1/6 The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:14 Ver:001 14/17 P-511-544(V:1) PD104SM1 11. Precautions for use of LCD modules 11-1) Handling Precautions a. The display panel is made of glass. Do not subject it to a mechanical shock by dropping it from a high place, etc. b. If the display panel is damaged and the liquid crystal substance inside it leaks out, be sure not to get any in your mouth, if the substance comes into contact with your skin or clothes, promptly wash it off using soap and water. c. Do not apply excessive force to the display surface or the adjoining areas since this may cause the color tone to vary. d. The polarizer covering the display surface of the LCD modules is soft and easily scratched. Handle this polarizer carefully. e. If the display surface is contaminated, breathe on the surface and gently wipe it with a soft dry cloth. If still not completely clear, moisten cloth with one of the following solventsΚ ЁIsopropyl alcohol ЁEthyl alcohol f. Solvents other than those mentioned above may damage the polarizer. Especially, do not use the followingΚ ЁWater ЁKetone ЁAromatic solvents g. Do not attempt to disassemble the LCD Module. h. If the logic circuit power is off, do not apply the input signals. I. To prevent destruction of the elements by static electricity, be careful to maintain an optimum work environment. 11-2) Be sure to ground the body when handling the LCD Modules. 11-3) Tools required for assembly, such as soldering irons, must be properly ground. 11-4) To reduce the amount of static electricity generated, do not conduct assembly and other work under dry conditions. 11-5) Please following the tear off direction as figure 11-1 to remove the protective film as slowly as possible, so that electrostatic charge can be minimized. 11-6) Storage precautions a. When storing the LCD modules, avoid exposure to direct sunlight or to the light of fluorescent lamps. b. The LCD modules should be stored under the storage temperature range. If the LCD modules will be stored for a long time, the recommend conditions isΚ TemperatureΚ0к~40к Relatively humidityΚЉ80н c. The LCD modules should be stored in the room without acid, alkali and harmful gas. 11-7) Transportation Precautions a. The LCD modules should be no falling and violent shocking during transportation, and also should avoid excessive press, water, damp and sunshine. Figure 11-1 the way to peel off protective film The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:15 Ver:001 15/17 P-511-544(V:1) PD104SM1 12. Reliability Test No Test Item Test Condition Remark 1 High Temperature Operation Test Ta = +70к, 240 hrs IEC60068-2-2,GB2423.2Ё89 2 Low Temperature Operation Test Ta = -20к, 240 hrs IEC60068-2-1,GB2423.1Ё89 3 High Temperature Storage Test Ta = +80к, 240 hrs IEC60068-2-2,GB2423.2Ё89 4 Low Temperature Storage Test Ta = -30к, 240 hrs IEC60068-2-1,GB2423.1Ё89 5 6 High Temperature & High Humidity Ta = +60к, 90%RH max, 240 Operation Test hrs Thermal Shock -20к 30min ~ +70к 30min (non-operation) Change timeΚ5min, 100 Cycle C=150pFΔR=330Ө 7 Electrostatic Discharge Test (operation) Vibration Test 8 (non-operation) Shock Test 9 (non-operation) 10 Package Drop Test 11 Package Vibration Test IEC60068-2-3,GB/T2423.2Ё2006 Start with cold temperature, end with high temperature IEC60068-2-14,GB2423.22 Ё87 IEC61000-4-2 GB/T17626.2Ё1998 Air = ±15KV Contact = ±8KV 10 times/terminal IEC60068-2-6 FrequencyΚ10 ~ 55 HZ GB/T2423.10Ё1995 StrokeΚ1.5mm SweepΚ10 Hz~55 Hz~10 Hz Test period Κ 2 hours for each direction of X, Y, Z (6 hours for total) IEC60068-2-27 GravityΚ80G 6ms GB/T2423.5Ё1995 Direction: ̈́X, ̈́Y, ̈́Z 3 times for each direction IEC60068-2-32 HeightΚ80cmΔ1 corner GB/2423.8Ё1995 3 edgesΔ6 surfaces IEC60068-2-34 Random VibrationΚ 0.015G*G/Hz for 5-200Hz -6dB/Octave from 200-500Hz 2 hours for each direction of X,Y,Z (6 hours for total) TaΚambient temperature NoteΚThe protective film must be removed before temperature test [Criteria] In the standard conditions, there is not display function NG issue occurred. (IncludingΚline defect, no image) All the cosmetic specification is judged before the reliability stress. The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:16 Ver:001 16/17 P-511-544(V:1) PD104SM1 13. Packing Diagram The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:17 Ver:001 17/17