pdf

www.osram.com/prevaled
PrevaLED® Flat AC – PL-FLAT-AC-G1 xx00-8y0-230V C-EM
xx =15 for 1500lm, 23 for 2300lm, 25 for 2500lm; y = 3 for 3000K, 4 for 4000K
Technical information
Benefits
−
−
−
−
−
−
Suitable for emergency lighting:
DC-voltage operation for central battery emergency lighting
Integrated power supply on board
Optimal design for low profile luminaires with high uniformity
High system efficacy and simple thermal management
High reliability through overheating protection
Touch protection accessory for safe LEDifying of existing
luminaires
Applications
For general illumination in:
− Corridors, Stairways, Entrance ways
− Hospitality: Hotels, Restaurants
− Public, Commercial & Office buildings
− Secondary rooms: garages, storage, …
(picture for reference only)
Technical operating data
Product
typ. Power
[W]
PL-FLAT-AC-G1 1500-830
230V C-EM
13.6
rated
ACVoltage
[Vac]
230
rated DCVoltage
range[V]
lum. flux at
DC-operation
[lm]
Color
Temp.
[K]
nom.
lum. flux
[lm]
Beam
angle
[°]
1500
nom.
efficac
y
[lm/W]
110
176 – 275
400
3000
PL-FLAT-AC-G1 1500-840
230V C-EM
12.5
230
176 – 275
440
4000
1500
120
112
PL-FLAT-AC-G1 2300-830
230V C-EM
20.5
230
176 – 275
400
3000
2300
112
112
PL-FLAT-AC-G1 2500-840
230V C-EM
20.5
230
176 - 275
440
4000
2500
122
112
112
max.
lum flux
[lm]
1650
max Power
[W]
power
factor λ
diameter
[mm]
tp
[°C]1
tc
[°C]
PL-FLAT-AC-G1 1500-830 230V C-EM
min.
lum flux
[lm]
1350
15
>0.9
170
75
85
Energy
efficiency
index
A+
PL-FLAT-AC-G1 1500-840 230V C-EM
1350
1650
13.8
>0.9
170
75
85
A+
Product
PL-FLAT-AC-G1 2300-830 230V C-EM
2070
2530
22.6
>0.9
240
75
85
A+
PL-FLAT-AC-G1 2500-840 230V C-EM
2250
2750
22.6
>0.9
240
75
85
A+
1
tp refers to the temperature at the tc-point related to the performance of the LED light engine (see IEC/PAS 62717).
Note:
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect
statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the
typical data.
PrevaLED® Flat AC G1 C-EM
Edition: 10.2015
1/4
www.osram.com/prevaled
DC operation
Light engine for emergeny lighting at central battery systems. Additional details for DC operation listed below.
170mm
Tc=75°C
P_in [W]
U_in [VDC]
4,2
5,7
Φ [lm] 830
Φ [lm] 840
Φ [% of nom]
830
Φ [% of nom]
840
I_in [mA]
I_LED [mA]
176
24
22,7
379
416
25,2%
27,7%
230
24,7
23
383
421
25,6%
28,1%
6,9
275
25,1
23,2
386
424
25,8%
28,3%
P_in [W]
U_in [VDC]
I_in [mA]
I_LED [mA]
Φ [lm] 830
Φ [lm] 840
Φ [% of nom]
830
Φ [% of nom]
840
4,3
176
24,3
22,7
371
400
16,1%
17,4%
5,7
230
24,8
23,1
378
408
16,4%
17,7%
6,9
275
25,2
23,5
384
414
16,7%
18,0%
240mm
Tc=75°C
Technical features
−
−
−
−
−
−
−
−
−
−
−
−
Note:
Rated luminous flux (typ.): 1500lm, 2300lm, 2500lm
Light colors:
o Warm white (3000K)
o Cool white (4000K)
Color rendering index: typ. 83
System efficacy: typ 120 lm/W at 4000K
Diameters: 170mm and 240mm
Operation with mains voltage: 220 – 240 Vac; 50/60Hz
Operation with DC-voltage: 176 – 275 V
Power factor > 0.9
Modulation of 100Hz with 40% depth
L70B50 @ 50,000 hours at tp=75°C (see IEC/PAS 62717)
L0C10 @ 50,000 hours at tp=75°C (see IEC/PAS 62717)
Specialized touch protection accessory (PL-FLTP 170 SL and PL-FLTP 240 SL).
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect
statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the
typical data.
PrevaLED® Flat AC G1 C-EM
Edition: 10.2015
2/4
www.osram.com/prevaled
Minimum and maximum ratings
Operating temperature
at tc-point [°C]2
-20 … 85
Product
PL- FLAT-AC-G1 xx00-8y0-230V
Storage temperature [°C]2
-20 … 85
Operating Voltage range
[Vac]3
220 … 240
The tc-point is at the front of the LED light engine and it is marked as “Tc”.
The LED light engine is designed to work on 230Vac mains voltage. Reverse wiring on the mains voltage wiring will not
impede the operation of the LED light engine. The thermal derating starts at a tc point temperature of > 90 °C.
Dimensions & mechanical data
small
170
Diameter (mm)
Weight (g)
113
Mounting
large
240
small
large
tbd
Solid wire cross-section
(mm²)
3 x M4
4 x M4
screws
screws
0.5 – 1.5
(AWG 16 – 20)
Stranded wire cross
section (mm², no ferrule
to be used)
0.5 – 1.5
(AWG 16 – 20)
(dimensions rounded)
(dimensions rounded)
Standard Compliance
CE
Eye Security
Ingress Protection
Environment
Dry Location, IP 20 (with PL-FLTP applied)
RoHS
Installation information
−
−
−
−
The LED light engine is designed to work on 230Vac mains voltage. Reverse wiring on the mains voltage wiring will
not impede the operation of the LED light engine.
Reverse wiring of “emergency” connector is not allowed.
For further installation advice please refer to the technical application guide on the OSRAM webpage.
Connect stranded wires with release button pressed.
Safety information
−
−
−
−
2
3
The LED light engine itself and all its components must not be mechanically stressed.
It is recommended to mount the LED light engine on a heat sink (e.g. sheet metal) providing adequate thermal
dissipation.
Do not damage or destroy conducting paths on the circuit board.
The LED light engine is mains voltage operated. All related safety precautions need to be observed.
Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED light
engine. The temperature of the LED light engine must be measured at the tc-point according to EN60598-1 in a thermally
stable state with a temperature sensor or a temperature sensitive label. The tc-point is clearly marked at on the product.
Exceeding maximum ratings for operating voltage range will lead to a change in performance and lifetime and could
damage the LED light engine.
Note:
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect
statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the
typical data.
PrevaLED® Flat AC G1 C-EM
Edition: 10.2015
3/4
www.osram.com/prevaled
−
−
−
−
−
−
−
−
The LED light engine cannot be operated safely when the touch protection accessory is mechanically damaged,
unless the luminaire provides independent touch protection.
Installation of LED light engine needs to be made with regard to all applicable electrical and safety standards. Only
qualified personnel should be allowed to perform installation.
Parallel connection of the LED light engines is highly recommended as safe electrical operation mode. Serial
connection of the LED light engines is forbidden.
These light engines are based on 100Hz technology and modulate the light amplitude at this frequency. Therefore
the LE must not be applied in rooms with fast moving parts such as rotating machines, if there is a risk of frequency
interference. Fast moving parts might appear to stand still although being in motion. Possible interference with
camera/display systems should be checked.
Damage by corrosion will not be honored as materials defect claim. It is the user's responsibility to provide suitable
protection against corrosive agents, such as moisture, condensation and other harmful elements.
Pay attention not to exceed the maximum operation temperature 85°C at the tc point when the modules are used in
an enclosed environment.
The design of the housing/luminaire should be according to the IP standards applicable for the intended application.
See also the related application note (available on the OSRAM
Web Pages) for further details.
Ordering guide
LED light engines
Product
Order No 20 pieces
Quantity (pieces)
Order No 1 piece
Quantity
(pieces)
PL-FLAT-AC-G1 1500-830 230V C-EM
4052899135192
20
4052899938250
1
PL-FLAT-AC-G1 1500-840 230V C-EM
4052899135185
20
4052899938267
1
PL-FLAT-AC-G1 2300-830 230V C-EM
4052899135208
20
4052899938274
1
PL-FLAT-AC-G1 2500-840 230V C-EM
4052899135215
20
4052899938281
1
Accessory
Order No 20 pieces
Quantity (pieces)
Order No 1 piece
Quantity
(pieces)
PL-FLTP 170 SL (compatible with Flat AC C-EM)
4052899194045
20
4052899194038
1
PL-FLTP 240 SL (compatible with Flat AC C-EM)
4052899194069
20
4052899194052
1
Sales and technical support
OSRAM GmbH
Sales and technical support is given by the local OSRAM
subsidiaries.
Marcel-Breuer-Straße 6
80807 Munich, Germany
www.osram.com
+49.89.6213-0 (Headquarter)
+49.89.6213-6000 (Customer-Service-Center)
On the OSRAM website all subsidiaries are listed with
complete address and phone numbers.
Links and related further information
OSRAM LED Systems
OSRAM catalogue
General information
Note:
www.osram.com/prevaled
catalog.osram.com
www.osram.com
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect
statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the
typical data.
PrevaLED® Flat AC G1 C-EM
Edition: 10.2015
4/4