pdf

www.osram.com/prevaled
PrevaLED® Flat AC – PL-FLAT-AC-G1 xx00-8y0-230V L-EM
xx =15 for 1500lm, 23 for 2300lm, 25 for 2500lm; y = 3 for 3000K, 4 for 4000K
Technical information
Benefits
−
Separate LED-circuit for operation on local-battery emergency
units
High performing low cost LED-engine for diffuse wall- / ceilingmounted luminaires
Power on-board through integrated driver electronics
Low height luminaires with high uniformity realizable
Two Flat AC diameters for multiple luminaire diameters
High system efficacy for simple thermal management
Safety through thermal derating
Touch protect accessory for safe installation in existing
luminaires
−
−
−
−
−
−
−
Applications
For general illumination in:
− Corridors, Stairways, Entrance ways
− Hospitality: Hotels, Restaurants
− Public, Commercial & Office buildings
− Secondary rooms: garages, storage, …
(picture for reference only)
Technical operating data
Product
Color
PL-FLAT-AC-G1 1500-830 230V L-EM
PL-FLAT-AC-G1 1500-840 230V L-EM
Warm white
Cool white
typ.
Power
[W]
13.6
12.5
PL-FLAT-AC-G1 2300-830 230V L-EM
Warm white
20.4
230
3000
2300
113
112
PL-FLAT-AC-G1 2500-840 230V L-EM
Cool white
20.4
230
4000
2500
123
112
Product
rated
Voltage
[Vac]
230
230
Color
Temp. [K]
nom. lum.
flux [lm]
Beam
angle [°]
1500
1500
typ.
efficacy
[lm/W]
110
120
3000
4000
112
112
min.
lum flux
[lm]
1350
max.
lum flux
[lm]
1650
max Power
[W]
power
factor λ
diameter
[mm]
tp
[°C]1
tc
[°C]
15
>0.9
170
75
85
Energy
efficiency
index
A+
PL-FLAT-AC-G1 2300-830 230V L-EM
1350
2070
1650
2530
15
25
>0.9
>0.9
170
240
75
75
85
85
A+
A+
PL-FLAT-AC-G1 2500-840 230V L-EM
2250
2750
25
>0.9
240
75
85
A+
PL-FLAT-AC-G1 1500-830 230V L-EM
PL-FLAT-AC-G1 1500-840 230V L-EM
current [mA]
voltage [V]
flux [lm]
700
2.97
284
500
2.86
216
300
2.73
137
200
2.64
94
100
2.53
48
local emergency
LED circuit
operating
conditions
1
min. current
[mA]
100
max. current min. voltage max. voltage
[mA]
[V] @ 700mA [V] @ 700mA
700
2.85
3.3
tp refers to the temperature at the tc-point related to the performance of the LED light engine (see IEC/PAS 62717).
Note:
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect
statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the
typical data.
PrevaLED® Flat AC G1 L-EM
Edition: 10.2015
1/3
www.osram.com/prevaled
Technical features
−
−
Rated luminous flux: typ. 1500lm, 2300lm and 2500lm
Light colors:
o Warm white (3000K)
o Cool white (4000K)
Color rendering index: typ. 83
Operation with mains voltage: 220 – 240 Vac; 50/60Hz
Modulation of 100Hz with 40% depth
L70B50 @ 50,000 hours at tp=75°C (see IEC/PAS 62717)
L0C10 @ 50,000 hours at tp=75°C (see IEC/PAS 62717)
Specialized touch safe accessory (PL-FLTP 170 and PL-FLTP 240) to cover line-voltage carrying parts and enable
easy and safe installation in existing luminaires.
−
−
−
−
−
−
Minimum and maximum ratings
Product
PL- FLAT-AC-G1 xx00-8y0-230V L-EM
Operating temperature
at tc-point [°C]2
-20 … 85
Storage temperature [°C]2
-20 … 85
Operating Voltage range
[Vac]3
220 … 240
The tc-point is at the front of the LED light engine and it is marked as “Tc”.
The LED light engine is designed to work on 230Vac mains voltage. Reverse wiring on the mains voltage wiring will not
impede the operation of the LED light engine. The thermal derating starts at a tc point temperature of > 90 °C.
Dimensions & mechanical data
“small”
170
Diameter (mm)
Weight (g)
106
Mounting
“large”
240
“small”
“large”
176
Solid wire cross-section
(mm²)
3 x M4
4 x M4
screws
screws
0.5 – 1.5
(AWG 16 – 20)
Stranded wire cross
section (mm², no ferrule
to be used)
0.5 – 1.5
(AWG 16 – 20)
(dimensions rounded)
(dimensions rounded)
Standard Compliance
CE
Eye Security
Ingress Protection
Environment
EN 62031, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3
EN 62471, RG1 (prior to mounting in a diffuse luminaire)
Dry Location, IP 20 (with PL-FLTP applied)
RoHS
Safety information
−
2
3
The LED light engine itself and all its components may not be mechanically stressed.
Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED light
engine. The temperature of the LED light engine must be measured at the tc-point according to EN60598-1 in a thermally
stable state with a temperature sensor or a temperature sensitive label. The tc-point is clearly marked at on the product.
Exceeding maximum ratings for operating voltage range will lead to a change in performance and lifetime and could
damage the LED light engine.
Note:
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect
statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the
typical data.
PrevaLED® Flat AC G1 L-EM
Edition: 10.2015
2/3
www.osram.com/prevaled
−
−
−
−
−
−
−
−
−
−
−
It is recommended to mount the LED light engine on a heat sink (e.g. sheet metal) providing adequate thermal
dissipation.
Do not damage or destroy conducting paths on the circuit board.
The LED light engine is mains voltage operated. All related safety precautions need to be observed.
The LED light engine cannot be operated safely when the touch protection accessory is mechanically damaged,
unless the luminaire provides independent touch protection.
Installation of LED light engine needs to be made with regard to all applicable electrical and safety standards. Only
qualified personnel should be allowed to perform installation.
Parallel connection of the LED light engines is highly recommended as safe electrical operation mode. Serial
connection of the LED light engines is forbidden.
These light engines are based on 100Hz technology and modulate the light amplitude at this frequency. Therefore
the LE must not be applied in rooms with fast moving parts such as rotating machines, if there is a risk of frequency
interference. Fast moving parts might appear to stand still although being in motion. Possible interference with
camera/display systems should be checked.
Damage by corrosion will not be honored as materials defect claim. It is the user's responsibility to provide suitable
protection against corrosive agents, such as moisture, condensation and other harmful elements.
Pay attention not to exceed the maximum operation temperature 85°C at the tc point when the modules are used in
an enclosed environment.
The design of the housing/luminaire should be according to the IP standards applicable for the intended application.
See also the related application note (available on the OSRAM
Web Pages) for further details.
Ordering guide
LED light engines
Order No 20
pieces
Quantity
(pieces)
Order No 1 piece
Quantity
(pieces)
PL-FLAT-AC-G1 1500-830 230V L-EM
4052899167124
20
4052899167117
1
PL-FLAT-AC-G1 1500-840 230V L-EM
4052899167339
20
4052899167322
1
PL-FLAT-AC-G1 2300-830 230V L-EM
4052899167353
20
4052899167346
1
PL-FLAT-AC-G1 2500-840 230V L-EM
4052899167377
20
4052899167360
1
Order No 20
pieces
Quantity
(pieces)
Order No 1 piece
Quantity
(pieces)
PL-FLTP 170 L-EM
4052899167391
20
4052899167384
1
PL-FLTP 240 L-EM
4052899167414
20
4052899167407
1
Product
Accessory
Sales and technical support
OSRAM GmbH
Sales and technical support is given by the local OSRAM
subsidiaries.
Marcel-Breuer-Straße 6
80807 Munich, Germany
www.osram.com
+49.89.6213-0 (Headquarter)
+49.89.6213-6000 (Customer-Service-Center)
On the OSRAM website all subsidiaries are listed with
complete address and phone numbers.
Links and related further information
OSRAM LED Systems
OSRAM catalogue
General information
Note:
www.osram.com/prevaled
catalog.osram.com
www.osram.com
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect
statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the
typical data.
PrevaLED® Flat AC G1 L-EM
Edition: 10.2015
3/3