PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Measurement Assurance Technology 1600 Corporate Court, Suite 150, Irving, TX 75038 (Hereinafter called the Organization) and hereby declares that Organization is accredited in accordance with the recognized International Standard: ISO/IEC 17025:2005 This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (as outlined by the joint ISO-ILAC-IAF Communiqué dated January 2009): Laboratory and Field Calibration of Electrical, Dimensional, Weighing Devices and Pressure (As detailed in the supplement) Accreditation claims for such testing and/or calibration services shall only be made from addresses referenced within this certificate. This Accreditation is granted subject to the system rules governing the Accreditation referred to above, and the Organization hereby covenants with the Accreditation body’s duty to observe and comply with the said rules. For PJLA: Initial Accreditation Date: Issue Date: Accreditation No.: Certificate No.: December 7, 2009 October 24, 2012 68680 L12-205 _________________________ Tracy Szerszen President/Operations Manager Perry Johnson Laboratory Accreditation, Inc. (PJLA) 755 W. Big Beaver, Suite 1325 Troy, Michigan 48084 The validity of this certificate is maintained through ongoing assessments based on a continuous accreditation cycle. The validity of this certificate should be confirmed through the PJLA website: www.pjlabs.com Page 1 of 12 Certificate of Accreditation: Supplement Measurement Assurance Technology 1600 Corporate Court, Suite 150, Irving, TX 75038 Perry Murbarger Phone: 972-241-2165 Accreditation is granted to the facility to perform the following calibrations: Dimensional MEASURED INSTRUMENT, QUANTITY OR GAUGE Micrometers Calipers Micrometer End Standards RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE 1 mm to 304.8 mm (0.05 in to 12 in) 1 mm to 304.8 mm (0.05 in to 12 in) 1 in CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY (±) (3.3 + 0.051L) µm [(130 + 20L) µin] (21.3 + 0.063L) µm [(840 + 25L) µin] 15 µin CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED Gage Blocks ULM 600 and Gage Block Set Electrical MEASURED INSTRUMENT, QUANTITY OR GAUGE Equipment to Measure DC Voltage Equipment to Output DC Voltage Equipment to Measure DC Current Issue: 10/12 RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY (±) 3 µV to 330 mV 0.33 V to 3.3 V 3.3 V to 33 V 33 V to 330 V 20 µV/V + 1 µV 11 µV/V + 2 µV 12 µV/V + 20 µV 18 µV/V + 0.15 mV 330 V to 1 000 V 10 mV to 100 mV 0.1 V to 1 V 1 V to 10 V 10 V to 100 V 100 V to 1 000 V 18 µV/V + 1.5 mV 11 µV/V + 3.0 µV 10 µV/V + 0.3 µV 10 µV/V + 0.5 µV 12 µV/V + 30 µV 12 µV/V + 0.1 mV 0.2 kV to 120 kV 2 mV/V + 10 mV 0.06 µA to 330 µA 0.33 mA to 3.3 mA 3.3 mA to 33 mA 33 mA to 330 mA 0.33 A to 1.1 A 1.1 A to 3 A 3 A to 11 A 0.15 mA/A + 0.02 µA 11 A to 20.5 A 0.1 mA/A + 0.05 µA 0.1 mA/A + 0.25 µA 0.1 mA/A + 2.5 µA 0.2 mA/A + 40 µA 0.4 mA/A + 40 µA 0.5 mA/A + 0.5 mA 1.0 mA/A + 0.75 mA 20 A to 1 000 A 5.0 mA/A + 0.5 A This supplement is in conjunction with certificate #L12-205 CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED Fluke 5520A/SC1100 HP 3458 Opt. 002 Ross Engineering VD 120-6.2y-AK-lb-al Fluke 5520A/SC1100 Fluke 5520A/SC1100 w/Coil Clamp-On Only Page 2 of 12 Certificate of Accreditation: Supplement Measurement Assurance Technology 1600 Corporate Court, Suite 150, Irving, TX 75038 Perry Murbarger Phone: 972-241-2165 Accreditation is granted to the facility to perform the following calibrations: MEASURED INSTRUMENT, QUANTITY OR GAUGE Equipment to Output DC Current Equipment to Measure Resistance Equipment to Output Resistance Issue: 10/12 RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE 135 pA to 1 µA 1 to 10 µA 10 µA to 100 µA 0.1 mA to 1 mA 1 mA to 10 mA 10 mA to 100 mA 0.1 A to 1 A 3 mΩ to 11 Ω CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY (±) 27 µA/A + 45 pA 27 µA/A + 110 pA 27 µA/A + 900 pA 27 µA/A + 6 nA 27 µA/A + 60 nA 42 µA/A + 0.6 µA CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED HP 3458A Opt. 002 117 µA/A + 12 µA 11 Ω to 33 Ω 33 Ω to 110 Ω 110 Ω to 330 Ω 0.33 kΩ to 1.1 kΩ 40 µΩ/Ω + 1 mΩ 30 µΩ/Ω + 1.5 mΩ 28 µΩ/Ω + 1.4 mΩ 28 µΩΩ + 2 mΩ 28 µΩ/Ω + 2 mΩ 1.1 kΩ to 3.3 kΩ 3.3 kΩ to 11 kΩ 11 kΩ to 33 kΩ 33 kΩ to 110 kΩ 110 kΩ to 330 kΩ 0.33 MΩ to 1.1 MΩ 28 µΩ/Ω + 20 mΩ 28 µΩ/Ω + 20 mΩ 28 µΩ/Ω + 200 mΩ 28 µΩ/Ω + 200 mΩ 32 µΩ/Ω + 2 Ω 32 µΩ/Ω + 2 Ω 1.1 MΩ to 3.3 MΩ 3.3 MΩ to 11 MΩ 11 MΩ to 33 MΩ 33 MΩ to 110 MΩ 110 MΩ to 330 MΩ 0.33 MΩ to 1 100 MΩ 1 Ω to 10 Ω 60 µΩ/Ω + 30 Ω 130 µΩ/Ω + 50 Ω 250 µΩ/Ω + 2.5 kΩ 500 µΩ/Ω + 3 kΩ 0.3 mΩ/Ω + 100 kΩ 1.5 mΩ/Ω + 500 kΩ 10 Ω to 100 Ω 0.1 kΩ to 1 kΩ 1 kΩ to 10 kΩ 10 kΩ to 100 kΩ 0.1 MΩ to 1 MΩ 21 µΩ/Ω + 60 µΩ 18 µΩ/Ω + 0.6 mΩ 16 µΩ/Ω + 0.6 mΩ 16 µΩ/Ω + 6 mΩ 16 µΩ/Ω + 60 mΩ 21 µΩ/Ω + 3 Ω 1 MΩ to 10 MΩ 10 MΩ to 100 MΩ 100 MΩ to 1 000 MΩ 73 µΩ/Ω + 30 Ω 600 µΩ/Ω + 300 Ω 6 mΩ/Ω + 3 kΩ Fluke 5520A/SC1100 HP 3458A Opt. 002 This supplement is in conjunction with certificate #L12-205 Page 3 of 12 Certificate of Accreditation: Supplement Measurement Assurance Technology 1600 Corporate Court, Suite 150, Irving, TX 75038 Perry Murbarger Phone: 972-241-2165 Accreditation is granted to the facility to perform the following calibrations: Electrical MEASURED INSTRUMENT, QUANTITY OR GAUGE RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE Equipment to Measure AC Voltage At the listed frequencies 10 Hz to 45 Hz 1 mV to 33 mV 45 Hz to 10 kHz 1 mV to 33 mV CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY (±) Fluke 5520A/SC1100 0.8 mV/V + 6 µV 0.15 mV/V + 6 µV 10 kHz to 20 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz 100 kHz to 500 kHz Equipment to Measure AC Voltage At the listed frequencies 10 Hz to 45 Hz 45 Hz to 10 kHz 10 kHz to 20 kHz 20 kHZ to 50 kHz 1 mV to 33 mV 1 mV to 33 mV 1 mV to 33 mV 1 mV to 33 mV 0.2 mV/V + 6 µV 1.0 mV/V + 6 µV 3.5 mV/V + 12 µV 8.0 mV/V+ 50 µV 33 mV to 330 mV 33 mV to 330 mV 33 mV to 330 mV 33 mV to 330 mV 0.3 mV/V + 8 µV 0.15 mV/V + 8 µV 0.16 mV/V + 8 µV 0.4 mV/V + 8 µV 50 kHz to 100 kHz 100 kHz to 500 kHz Equipment to Measure AC Voltage At the listed frequencies 10 Hz to 45 Hz 45 Hz to 10 kHz 10 kHz to 20 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz 100 kHz to 500 kHz 33 mV to 330 mV 33 mV to 330 mV 0.8 mV/V + 32 µV 2.0 mV/V + 70 µV 0.33 V to 3.3 V 0.33 V to 3.3 V 0.33 V to 3.3 V 0.33 V to 3.3 V 0.33 V to 3.3 V 0.33 V to 3.3 V 0.3 mV/V + 50 µV 0.15 mV/V + 60 µV 0.19 mV/V + 60 µV 0.3 mV/V + 50 µV 0.7 mV/V + 1.25 mV 2.4 mV/V + 0.6 mV Equipment to Measure AC Voltage At the listed frequencies 10 Hz to 45 Hz 3.3 V to 33 V 45 Hz to 10 kHz 3.3 V to 33 V 0.3 mV/V + 0.65 mV 0.2 mV/V + 0.6 mV 10 kHz to 20 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz 0.3 mV/V + 0.6 mV 0.4 mV/V + 0.6 mV 0.9 mV/V + 1.6 mV Issue: 10/12 3.3 V to 33 V 3.3 V to 33 V 3.3 V to 33 V CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED This supplement is in conjunction with certificate #L12-205 Page 4 of 12 Certificate of Accreditation: Supplement Measurement Assurance Technology 1600 Corporate Court, Suite 150, Irving, TX 75038 Perry Murbarger Phone: 972-241-2165 Accreditation is granted to the facility to perform the following calibrations: Electrical MEASURED INSTRUMENT, QUANTITY OR GAUGE RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE Equipment to Measure AC Voltage At the listed frequencies 45 Hz to 1 kHz 33 V to 330 V 1 kHz to 10 kHz 33 V to 330 V 10 kHz to 20 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz Equipment to Measure AC Voltage At the listed frequencies 45 Hz to 1 kHz 1 kHz to 5 kHz 5 kHz to 10 kHz Equipment to Output AC Voltage At the listed frequencies 50 Hz to 60 Hz Equipment to Output AC Voltage At the listed frequencies 1 Hz to 40 Hz 40 Hz to 1 kHz 1 kHz to 20 kHz 20 kHz to 50 kHz CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY (±) Fluke 5520A/SC1100 0.19 mV/V + 2 mV 0.2 mV/V + 6 mV 33 V to 330 V 33 V to 330 V 33 V to 330 V 0.3 mV/V + 6 mV 0.3 mV/V + 6 mV 2.0 mV/V + 50 mV 330 V to 1 020 V 330 V to 1 020 V 330 V to 1 020 V 0.3 mV/V + 10 mV 0.3 mV/V + 10 mV 0.3 mV/V + 10 mV Ross Engineering VD 120-6.2y-AK-lb-al 0.2 kV t o120 kV 6 mV/V + 10 mV HP 3458A Opt. 002 1 mV to 10 mV 1 mV to 10 mV 1 mV to 10 mV 1 mV to 10 mV 0.4 mV/V + 5 µV 0.3 mV/V + 4 µV 0.4 mV/V + 4 µV 1.1 mV/V + 4 µV 50 kHz to 100 kHz 1 mV to 10 mV 100 kHz to 300 kHz 1 mV to 10 mV Equipment to Output AC Voltage At the listed frequencies 1 Hz to 40 Hz 10 mV to 100 mV 40 Hz to 1 kHz 10 mV to 100 mV 1 kHz to 20 kHz 10 mV to 100 mV 20 kHz to 50 kHz 10 mV to 100 mV 50 kHz to 100 kHz 10 mV to 100 mV 100 kHz to 300 kHz 10 mV to 100 mV 5.5 mV/V + 4 µV 45.0 mV/V + 4 µV 300 kHz to 1 MHz 1 MHz to 2 MHz 11.0 mV/V + 10 µV Issue: 10/12 CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED 10 mV to 100 mV 10 mV to 100 mV 0.1 mV/V + 4 µV 0.1 mV/V + 2 µV 0.15 mV/V + 2 µV 0.4 mV/V + 2 µV 0.9 mV/V + 2 µV 3.5 mV/V + 10 µV 16 mV/V + 10 µV This supplement is in conjunction with certificate #L12-205 Page 5 of 12 Certificate of Accreditation: Supplement Measurement Assurance Technology 1600 Corporate Court, Suite 150, Irving, TX 75038 Perry Murbarger Phone: 972-241-2165 Accreditation is granted to the facility to perform the following calibrations: MEASURED INSTRUMENT, QUANTITY OR GAUGE RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY (±) Equipment to Output AC Voltage At the listed frequencies 1 Hz to 40 Hz 0.1 V to 1 V 40 Hz to 1 kHz 0.1 V to 1 V 0.1 mV/V + 4 µV 0.1 mV/V + 2 µV 1 kHz to 20 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz 100 kHz to 300 kHz 300 kHz to 1 MHz 1 MHz to 2 MHz 0.15 mV/V + 2 µV 0.4 mV/V + 2 µV 0.9 mV/V + 2 µV 3.5 mV/V + 10 µV 11.0 mV/V + 10 µV 16.0 mV/V + 10 µV 0.1 V to 1 V 0.1 V to 1 V 0.1 V to 1 V 0.1 V to 1 V 0.1 V to 1 V 0.1 V to 1 V HP 3458A Opt. 002 Equipment to Output AC Voltage At the listed frequencies 1 Hz to 40 Hz 1 V to 10 V 40 Hz to 1 kHz 1 V to 10 V 0.1 mV/V + 4 µV 0.1 mV/V + 2 µV 1 kHz to 20 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz 100 kHz to 300 kHz 300 kHz to 1 MHz 1 MHz to 2 MHz 0.15 mV/V + 2 µV 0.4 mV/V + 2 µV 0.9 mV/V + 2 µV 3.5 mV/V + 10 µV 11.0 mV/V + 10 µV 16 mV/V + 10 µV 1 V to 10 V 1 V to 10 V 1 V to 10 V 1 V to 10 V 1 V to 10 V 1 V to 10 V Equipment to Output AC Voltage At the listed frequencies 1 Hz to 40 Hz 10 V to 100 V 40 Hz to 1 kHz 10 V to 100 V 0.3 mV/V + 4 mV 0.2 mV/V + 2 mV 1 kHz to 20 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz 100 kHz to 300 kHz 300 kHz to 1 MHz 0.2 mV/V + 2 mV 0.4 mV/V + 2 mV 1.5 mV/V + 2 mV 4.0 mV/V +10 mV 15 mV/V + 10 mV Issue: 10/12 10 V to 100 V 10 V to 100 V 10 V to 100 V 10 V to 100 V 10 V to 100 V CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED This supplement is in conjunction with certificate #L12-205 Page 6 of 12 Certificate of Accreditation: Supplement Measurement Assurance Technology 1600 Corporate Court, Suite 150, Irving, TX 75038 Perry Murbarger Phone: 972-241-2165 Accreditation is granted to the facility to perform the following calibrations: Electrical MEASURED INSTRUMENT, QUANTITY OR GAUGE RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE Equipment to Output AC Voltage At the listed frequencies 1 Hz to 40 Hz 100 V to 1 000 V 40 Hz to 1 kHz 100 V to 1 000 V 1 kHz to 20 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz Equipment to Measure AC Current At the listed frequencies 10 Hz to 20 Hz 20 Hz to 45 Hz 45 Hz to 1 kHz 1 kHz to 5 kHz 5 kHz to 10 kHz 100 V to 1 000 V 100 V to 1 000 V 100 V to 1 000 V HP 3458A Opt. 002 0.5 mV/V + 40 mV 0.5 mV/V + 20 mV 0.7 mV/V + 20 mV 1.5 mV/V + 20 mV 4.0 mV/V + 20 mV 29 µA to 330 µA 29 µA to 330 µA 29 µA to 330 µA 29 µA to 330 µA 29 µA to 330 µA 2.0 mA/A + 0.1 µA 2.0 mA/A + 0.1 µA 1.3 mA/A + 0.1 µA 3.0 mA/A + 0.15 µA 8.0 mA/A + 0.2 µA 16.0 mA/A + 0.4 µA 2.0 mA/A + 0.15 µA 0.33 mA to 3.3 mA 0.33 mA to 3.3 mA 0.33 mA to 3.3 mA 0.33 mA to 3.3 mA 0.33 mA to 3.3 mA 13 mA/A + 0.15 µA 1.0 mA/A + 0.15 µA 2.0 mA/A + 0.2 µA 5.0 mA/A + 0.3 µA 10.0 mA/A + 0.6 µA 20 Hz to 45 Hz 45 Hz to 1 kHz 3.3 mA to 33 mA 3.3 mA to 33 mA 3.3 mA to 33 mA 2.0 mA/A + 2 µA 1.0 mA/A + 2 µA 0.5 mA/A + 2 µA 1 kHz to 5 kHz 5 kHz to 10 kHz 10 kHz to 30 kHz 3.3 mA to 33 mA 3.3 mA to 33 mA 3.3 mA to 33 mA 1.0 mA/A + 2 µA 2.0 mA/A + 3 µA 4.0 mA/A + 4 µA Issue: 10/12 CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED Fluke 5520A/SC1100 10 kHz to 30 kHz 29 µA to 330 µA Equipment to Measure AC Current At the listed frequencies 10 Hz to 20 Hz 0.33 mA to 3.3 mA 20 Hz to 45 Hz 45 Hz to 1 kHz 1 kHz to 5 kHz 5 kHz to 10 kHz 10 kHz to 30 kHz Equipment to Measure AC Current At the listed frequencies 10 Hz to 20 Hz CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY (±) This supplement is in conjunction with certificate #L12-205 Page 7 of 12 Certificate of Accreditation: Supplement Measurement Assurance Technology 1600 Corporate Court, Suite 150, Irving, TX 75038 Perry Murbarger Phone: 972-241-2165 Accreditation is granted to the facility to perform the following calibrations: Electrical MEASURED INSTRUMENT, QUANTITY OR GAUGE RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY (±) Equipment to Measure AC Current At the listed frequencies 10 Hz to 20 Hz 33 mA to 330 mA 20 Hz to 45 Hz 33 mA to 330 mA 2.0 mA/A + 20 µA 1.0 mA/A + 20 µA 45 Hz to 1 kHz 33 mA to 330 mA 0.5 mA/A + 20 µA 1 kHz to 5 kHz 5 kHz to 10 kHz 10 kHz to 30 kHz 33 mA to 330 mA 33 mA to 330 mA 33 mA to 330 mA 1.0 mA/A + 50 µA 2.0 mA/A + 0.1 mA 4.0 mA/A + 0.2 mA Equipment to Measure AC Current At the listed frequencies 10 Hz to 45 Hz 0.33 A to 1.1 A 45 Hz to 1 kHz 0.33 A to 1.1 A 1 kHz to 5 kHz 5 kHz to 10 kHz Equipment to Measure AC Current At the listed frequencies 10 Hz to 45 Hz 45 Hz to 1 kHz 1 kHz to 5 kHz 5 kHz to 10 kHz Equipment to Measure AC Current At the listed frequencies 45 Hz to 100 Hz Issue: 10/12 Fluke 5520A/SC1100 2.0 mA/A + 0.1 mA 0.5 mA/A + 0.1 mA 0.33 A to 1.1 A 0.33 A to 1.1 A 6.0 mA/A + 1 mA 25.0 mA/A + 5 mA 1.1 A to 3 A 1.1 A to 3 A 1.1 A to 3 A 1.1 A to 3 A 2.0 mA/A + 0.1 mA 0.6 mA/A + 0.1 mA 6.0 mA/A + 1 mA 25 mA/A + 5 mA 3 A to 11 A 3 A to 11 A 3 A to 11 A 0.6 mA/A + 2 mA 1.0 mA/A + 2 mA 30.0 mA/A + 2 mA 100 Hz to 1 kHz 1 kHz to 5 kHz Equipment to Measure AC Current At the listed frequencies 45 Hz to 100 Hz 11 A to 20.5 A 100 Hz to 1 kHz 11 A to 20.5 A 1 kHz to 5 kHz 11 A to 20.5 A CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED 1.2 mA/A + 5 mA 1.5 mA/A + 5 mA 30.0 mA/A + 5 mA This supplement is in conjunction with certificate #L12-205 Page 8 of 12 Certificate of Accreditation: Supplement Measurement Assurance Technology 1600 Corporate Court, Suite 150, Irving, TX 75038 Perry Murburger Phone: 972-241-2165 Accreditation is granted to the facility to perform the following calibrations: Electrical MEASURED INSTRUMENT, QUANTITY OR GAUGE RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE Equipment to Output AC Current At the listed frequencies 10 Hz to 20 Hz 5 µA to 100 µA 20 Hz to 45 Hz 5 µA to 100 µA CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY (±) HP 3458A Opt. 002 4.1 mA/A + 0.04 µA 1.6 mA/A + 0.04 µA 45 Hz to 100 Hz 5 µA to 100 µA 100 Hz to 5 kHz 5 µA to 100 µA Equipment to Output AC Current At the listed frequencies 10 Hz to 20 Hz 0.1 mA to 1 mA 20 Hz to 45 Hz 0.1 mA to 1 mA 45 Hz to 100 Hz 0.1 mA to 1 mA 100 Hz to 5 kHz 0.1 mA to 1 mA 5 kHz to 20 kHz 0.1 mA to 1 mA Equipment to Output AC Current At the listed frequencies 10 Hz to 20 Hz 1 mA to 10 mA 20 Hz to 45 Hz 1 mA to 10 mA 45 Hz to 100 Hz 1 mA to 10 mA 0.7 mA/A + 0.04 µA 0.7 mA/A + 0.04 µA 100 Hz to 5 kHz 1 mA to 10 mA 5 kHz to 20 kHz 1 mA to 10 mA Equipment to Output AC Current At the listed frequencies 10 Hz to 20 Hz 10 mA to 100 mA 20 Hz to 45 Hz 10 mA to 100 mA 45 Hz to 100 Hz 10 mA to 100 mA 100 Hz to 5 kHz 10 mA to 100 mA 5 kHz to 20 kHz 10 mA to 100 mA Equipment to Output AC Current At the listed frequencies 10 Hz to 20 Hz 0.1 A to 1 A 20 Hz to 45 Hz 0.1 A to 1 A 45 Hz to 100 Hz 0.1 A to 1 A 0.4 mA/A + 0.2 µA 0.7 mA/A + 0.2 µA 100 Hz to 5 kHz 5 kHz to 20 kHz Issue: 10/12 0.1 A to 1 A 0.1 A to 1 A CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED 4.1 mA/A + 0.2 µA 1.6 mA/A + 0.2 µA 0.7 mA/A + 0.2 µA 0.4 mA/A + 0.2 µA 0.7 mA/A + 0.2 µA 4.1 mA/A + 0.2 µA 1.6 mA/A + 0.2 µA 0.7 mA/A + 0.2 µA 4.1 mA/A + 0.2 µA 0.7 mA/A + 0.2 µA 0.7 mA/A + 0.2 µA 0.7 mA/A + 0.2 µA 0.7 mA/A + 0.2 µA 1.7 mA/A + 0.2 mA 0.9 mA/A + 0.2 mA 1.1 mA/A + 0.2 mA 3.1 mA/A + 0.2 mA 10.0 mA/A + 0.4 mA This supplement is in conjunction with certificate #L12-205 Page 9 of 12 Certificate of Accreditation: Supplement Measurement Assurance Technology 1600 Corporate Court, Suite 150, Irving, TX 75038 Perry Murbarger Phone: 972-241-2165 Accreditation is granted to the facility to perform the following calibrations: Electrical MEASURED INSTRUMENT, QUANTITY OR GAUGE Equipment to Measure Capacitance At the listed frequency 10 Hz to 10 kHz Equipment to Measure Capacitance At the listed frequencies 10 Hz to 3 kHz Equipment to Measure Capacitance At the listed frequencies 10 Hz to 1 kHz Equipment to Measure Capacitance At the listed frequencies 10 Hz to 600 Hz 10 Hz to 300 Hz 10 Hz to 150 Hz 10 Hz to 120 Hz 10 Hz to 80 Hz Equipment to Measure Capacitance At the listed frequencies Up to 50 Hz Up to 20 Hz Up to 6 Hz Up to 2 Hz Up to 0.6 Hz Up to 0.2 Hz Temperature Calibration, Indication, and Control Equipment used with Thermocouple Type B Temperature Calibration, Indication, and Control Equipment used with Thermocouple Type C Issue: 10/12 RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY (±) 0.19 nF to 0.4 nF 5 mF/F + 10 pF 0.4 nF to 1.1 nF 5 mF/F + 10 pF 1.1 nF to 3.3 nF 5 mF/F + 10 pF 3.3 nF to 11 nF 2.5 mF/F + 10 pF 11 nF to 33 nF 33 nF to 110 nF 110 nF to 330 nF 2.5 mF/F + 100 pF 2.5 mF/F + 100 pF 2.5 mF/F + 300 pF 0.33 µF to 1.1 µF 1.1 µF to 3.3 µF 3.3 µF to 11 µF 2.5 mF/F + 1 nF 2.5 mF/F + 3 nF 2.5 mF/F + 10 nF 11 µF to 33 µF 33 µF to 110 µF 4 mF/F + 30 nF 4.5 mF/F + 100 nF 110 µF to 330 µF 0.33 µF to 1.1 mF 1.1 mF to 3.3 mF 4.5 mF/F + 300 nF 4.5 mF/F + 1 µF 4.5 mF/F + 3 µF 4.5 mF/F + 10 µF 7.5 mF/F + 30 µF 11 mF/F + 100 µF 3.3 mF to11 mF 11 mF to 33 mF 33 mF to 100 mF 600 °C to 800 °C 800 °C to 1 000 °C 1 000 °C to 1 550 °C 1 550 °C to 1 820 °C 0 °C to 150 °C 150 °C to 650 °C 650 °C to 1 000 °C 1 000 °C to 1 800 °C 1 800 °C to 2 316 °C 0.44 °C 0.34 °C 0.30 °C 0.33 °C 0.30 °C CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED Fluke 5520A/SC1100 Electrical Simulation of Thermocouple Output Fluke 5520A/SC1100 0.26 °C 0.31 °C 0.50 °C 0.84 °C This supplement is in conjunction with certificate #L12-205 Page 10 of 12 Certificate of Accreditation: Supplement Measurement Assurance Technology 1600 Corporate Court, Suite 150, Irving, TX 75038 Perry Murbarger Phone: 972-241-2165 Accreditation is granted to the facility to perform the following calibrations: Electrical MEASURED INSTRUMENT, QUANTITY OR GAUGE Temperature Calibration, Indication, and Control Equipment used with Thermocouple Type E Temperature Calibration, Indication, and Control Equipment used with Thermocouple Type J Temperature Calibration, Indication, and Control Equipment used with Thermocouple Type K Temperature Calibration, Indication, and Control Equipment used with Thermocouple Type L Temperature Calibration, Indication, and Control Equipment used with Thermocouple Type N Temperature Calibration, Indication, and Control Equipment used with Thermocouple Type R Temperature Calibration, Indication, and Control Equipment used with Thermocouple Type S Temperature Calibration, Indication, and Control Equipment used with Thermocouple Type T Issue: 10/12 RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY (±) -250 °C to -100 °C -100 °C to -25 °C -25 °C to 120 °C 120 °C to 410 °C 410 °C to 1 300 °C -210 °C to -100 °C 0.50 °C 0.16 °C 0.14 °C 0.16 °C 0.21 °C -100 °C to -30 °C -30 °C to 150 °C 150 °C to 760 °C 760 °C to 1 200 °C -200 °C to -100 °C -100 °C to -25 °C 0.16 °C 0.14 °C 0.17 °C 0.23 °C -25 °C to 120 °C 120 °C to 1 000 °C 1 000 °C to 1 372 °C -200 °C to -100 °C -100 °C to 800 °C 800 °C to 900 °C Electrical Simulation of Thermocouple Output Fluke 5520A/SC1100 0.27 °C 0.33 °C 0.18 °C 0.16 °C 0.26 °C 0.40 °C 0.37 °C 0.26 °C 0.17 °C -250 °C to -100 °C -100 °C to -25 °C -25 °C to 120 °C 120 °C to 410 °C 410 °C to 1 300 °C 0 °C to 250 °C 0.40 °C 0.22 °C 0.19 °C 0.18 °C 0.27 °C 250 °C to 400 °C 400 °C to 1 000 °C 1 000 °C to 1 767 °C 0 °C to 250 °C 250 °C to 1 000 °C 1 000 °C to 1 400 °C 0.35 °C 0.33 °C 0.40 °C 1 400 °C to 1 767 °C -250 °C to -150 °C -150 °C to 0 °C 0 °C to 120 °C 120 °C to 400 °C CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED 0.57 °C 0.47 °C 0.36 °C 0.37 °C 0.46 °C 0.63 °C 0.24 °C 0.16 °C 0.14 °C This supplement is in conjunction with certificate #L12-205 Page 11 of 12 Certificate of Accreditation: Supplement Measurement Assurance Technology 1600 Corporate Court, Suite 150, Irving, TX 75038 Perry Murburger Phone: 972-241-2165 Accreditation is granted to the facility to perform the following calibrations: Mass, Force, and Weighing Devices MEASURED INSTRUMENT, QUANTITY OR GAUGE Scales/Balances RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE 1 mg to 500 mg 1 g to 10 g 20 g to 50 g 100 g to 500 g 0.5 lb to 150 lb CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY (±) 0.02 mg 0.10 mg 0.25 mg 2.40 mg 0.031 lb CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED Class 1 Weights Mechanical MEASURED INSTRUMENT, QUANTITY OR GAUGE Pressure Gauges RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE Up to 300 psi Up to 1.00 psi CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY (±) 0.097 psi 0.001 5 psi CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED Fluke 700P02 Fluke 700P27 1. The CMC (Calibration and Measurement Capability) stated for calibrations included on this scope of accreditation represent the smallest measurement uncertainties attainable by the laboratory when performing a more or less routine calibration of a nearly ideal device under nearly ideal conditions. It is expressed at a confidence level of 95 % using a coverage factor k (usually equal to 2). The actual measurement uncertainty associated with a specific calibration performed by the laboratory will typically be larger than the CMC for the same calibration since capability and performance of the device being calibrated and the conditions related to the calibration may reasonably be expected to deviate from ideal to some degree. 2. When calibrations are performed at customer locations the resulting measurement uncertainty associated with the calibration will typically be larger than the CMC stated on this scope of accreditation. This is due in large part to variation of environmental conditions at customer facilities, the effects of transport on any standards or equipment taken to customer sites and the resolution and repeatability unique to the device being calibrated. 3. The ranges stated in this scope of accreditation represent the values for which the laboratory is accredited to perform calibration. The equipment used to perform these calibrations is capable of measuring or outputting values of Voltage, Amperage and Resistance to magnitudes less than the low end of the range stated herein. As the value of the calibrated parameter approaches or becomes less than the magnitude of the CMC confidence in its usefulness is diminished. It is the policy therefore, of Perry Johnson Laboratory Accreditation Inc. to limit the low end of the range value to no less than three times the CMC. 4. The term L represents length in inches or millimeters appropriate to the uncertainty statement. Issue: 10/12 This supplement is in conjunction with certificate #L12-205 Page 12 of 12 Perry Johnson Laboratory Accreditation, Inc. October 24, 2012 Mr. Perry Murbarger Measurement Assurance Technology 1600 Corporate Court, Suite 150 Irving, TX 75038 Dear Mr. Murbarger; This letter is to confirm that you have successfully completed your reaccreditation assessment. A certificate has now been granted and posted on our website. As you are aware, PJLA will no longer be issuing expiration dates on our certificates. Your certificate # L12-205 will remain valid as long as you continue to maintain your annual assessments and reaccreditation assessments as stated in your customer agreement with PJLA. At this time, we have confirmed that your annual assessments will be conducted during the month of September each calendar year. This will include an interim surveillance assessment and a full system reassessment to be completed by September 2014. Once your reassessment is conducted and approved by our accreditation committee a revised status letter will be provided to you. Please allow PJLA at least 120 days from your assessment due date to issue this letter. Please feel free to release this letter to any interested parties as confirmation of your certificate validity. Also, please remind them that your certificate is posted on our website at all times. Any changes in regards to your accreditation status will be reflected on our website. We would like to thank you for your patronage over the past years and look forward to continuously serving your accreditation needs in the future. If we can assist you any further, please feel free to contact us at any time. Sincerely, Tracy Szerszen President/Operations Manager 755 W. Big Beaver Rd. · Suite 1325 · Troy, MI 48084 · Phone: 1-877-369-LABS or 248-519-2603 · Fax: 248-213-0737