DC Sensor Blower Only available for OEM S 2000 Type 002 Small sensor blower for active ventilation of temperature sensors used for climate control in cars. The active ventilation avoids mismeasurements due to irradiation of various heat sources. Significant reduced overall size due to the new motor technique of an external rotor motor on pinch pole basis. - Version without temperature sensor - Modular design with possible mechanical fixing also electrical connection from blower suck and back side - Plug-in version (without drive-electronics) - Sinter-Bearing-System - Quality Management ISO/TS 16949 (free air) Mass °C °C °C h dB h(A) dBg(A) g 934 1706 1706 006 002 934 8...16 8...16 13 13 <50 <50 650 22 650 18 18 0,64 -40...+100 -40...+95 -40...+100 -40...+100 5 000 5<26 000 <26 14 14 Masse Noise* CFM °C environment temp.) (freiblasend) Lebensdauer (bei Storage Temp. 23 °C Umgebungstemperatur) -3 3 x 10l/min m /min Service life (at 23°C Schalldruck* Operating Temp. Lagertemperatur (blower without electronics) rpm-1 min G(ebläse ohne Elektronik) Betriebstemperatur Air Flow mA mA (freiblasend) (free air) DC VV DC max. Max. Volumenstrom Flow Rate Stromaufnahme Nominal Current (f(free reiblasend) air) DC VV DC (freiblasend) (free air) Nennspannung Nominal Voltage Type Typ Nominal data Nenndrehzahl Nominal Speed Spannungsbereich Voltage Range ebm-papst • St. Georgen * Measured at free air delivery. Microphone distance 10 cm. Sensor blower assembled freerunning in elastic bands. All data are based on the operation with the commutation electronics indicated on the reverse side (average values at nominal voltage). ebm-papst St. Georgen GmbH & Co. KG Hermann-Papst-Straße 1 • D-78112 St. Georgen • Phone +49 (0) 77 24 / 81-0 • Fax +49 (0) 77 24 / 81-1309 • [email protected] • www.ebmpapst.com/de Wiring diagram VCC 8 V – 16 V External Drive-Electronics 5 Main winding At this S 2000 plug-in variant you are able to integrate the drive-electronics and the temperature sensor on your own choise. Also you can place it on your PCB. Ri approx. 127 W Coil 2 33 k 10 k 3 220 nF/25 V/X7R 4 At the wiring diagram we recommend a drive-electronics with protection for high voltage and reversed polarity. Blower diagnosis with special equipped drive-electronics possible (wiring diagram on request). Speed winding 360 R/0.1 W Ri approx. 257 W Coil 1 BC 817 –40 2 x BC 847C or 1 x FMW 3 GND 2 Sensor blower 2 x BZX 284 C5V1 BAS216 Dimensions 1 15 5 15.5 3 5 4 3 2 Ø 35 Ø2 2. 4 30 2 18 All measures in mm. Engineering drawing with tolerance indication on request. BAS 321 6 10.6 3 3.5 18.6 6 18 exhaust opening Fixing Mounting by clip or screw fixing on the PCB. Electrical terminals via soldering pins (terminals are not suitable for plug-type connection). Gold plated pins for a direct plug-type connection on request. L896 / 002 GB Technical subject to change without notice 0304