Automotive datasheet S2000-002 EN

DC Sensor Blower
Only available for OEM
S 2000 Type 002
Small sensor blower for active ventilation of temperature sensors used for climate control in
cars. The active ventilation avoids mismeasurements due to irradiation of various heat sources.
Significant reduced overall size due to the new motor technique of an external rotor motor on
pinch pole basis.
- Version without temperature sensor
- Modular design with possible mechanical fixing also
electrical connection from blower suck and back side
- Plug-in version (without drive-electronics)
- Sinter-Bearing-System
- Quality Management ISO/TS 16949
(free air)
Mass
°C
°C
°C
h
dB h(A)
dBg(A)
g
934 1706
1706 006
002
934
8...16
8...16
13
13
<50
<50
650
22 650
18
18
0,64
-40...+100
-40...+95
-40...+100
-40...+100
5 000
5<26
000
<26
14
14
Masse
Noise*
CFM
°C
environment temp.)
(freiblasend)
Lebensdauer (bei
Storage
Temp.
23
°C Umgebungstemperatur)
-3 3
x 10l/min
m /min
Service life (at 23°C
Schalldruck*
Operating Temp.
Lagertemperatur
(blower without electronics)
rpm-1
min
G(ebläse ohne Elektronik)
Betriebstemperatur
Air
Flow
mA
mA
(freiblasend)
(free air)
DC
VV DC
max.
Max. Volumenstrom
Flow Rate
Stromaufnahme
Nominal Current
(f(free
reiblasend)
air)
DC
VV DC
(freiblasend)
(free air)
Nennspannung
Nominal Voltage
Type
Typ
Nominal data
Nenndrehzahl
Nominal Speed
Spannungsbereich
Voltage Range
ebm-papst • St. Georgen
* Measured at free air delivery. Microphone distance 10 cm. Sensor blower assembled freerunning in elastic bands.
All data are based on the operation with the commutation electronics indicated on the reverse side (average values at nominal voltage).
ebm-papst St. Georgen GmbH & Co. KG
Hermann-Papst-Straße 1 • D-78112 St. Georgen • Phone +49 (0) 77 24 / 81-0 • Fax +49 (0) 77 24 / 81-1309 • [email protected] • www.ebmpapst.com/de
Wiring diagram
VCC
8 V – 16 V
External Drive-Electronics
5
Main winding
At this S 2000 plug-in variant you are able to integrate
the drive-electronics and the temperature sensor on your
own choise. Also you can place it on your PCB.
Ri approx. 127 W
Coil 2
33 k
10 k
3
220 nF/25 V/X7R
4
At the wiring diagram we recommend a drive-electronics
with protection for high voltage and reversed polarity.
Blower diagnosis with special equipped drive-electronics
possible (wiring diagram on request).
Speed winding
360 R/0.1 W
Ri approx. 257 W
Coil 1
BC 817
–40
2 x BC 847C
or
1 x FMW 3
GND
2
Sensor blower
2 x BZX 284 C5V1
BAS216
Dimensions
1
15
5
15.5
3
5
4
3
2
Ø 35
Ø2
2.
4
30
2
18
All measures in mm. Engineering drawing with tolerance
indication on request.
BAS
321
6
10.6
3
3.5
18.6
6
18
exhaust
opening
Fixing
Mounting by clip or screw fixing on the PCB.
Electrical terminals via soldering pins (terminals are not
suitable for plug-type connection).
Gold plated pins for a direct plug-type connection on
request.
L896 / 002 GB
Technical subject to change without notice
0304