Download

5W AC-DC Power-Supply PAC5B
●
●
●
●
●
85 … 264 VAC / 100 … 400 VDC universal input
Continuously short circuit and over current protected
Isolation class II
MTBF > 300000 hours
Small outlines
Model guide
Type
PAC5B03S
PAC5B05S
PAC5B09S
PAC5B12S
PAC5B15S
PAC5B24S
Output voltage
Output current range Ripple & noise up to Efficiency typ.@ full
20 MHz
load, Vin 230 VAC
Accuracy
min.
max.
[mVp-p] max.
[%] typ.
[VDC]
[%]
[mA]
[mA]
3.3
±3
100
1000
150
65
5.0
±2
100
1000
150
70
9.0
±2
56
560
150
72
12
±2
42
420
150
74
15
±2
34
340
150
75
24
±2
21
210
150
75
Capacitive load
[µF] max.
2200
1500
680
470
330
100
Specifications
Input
Voltage range
Frequency
Full load input current
Inrush current
Standby power
Recommended fuse
Hold up time
Isolation
Isolation voltage (input to output)
Isolation resistance
Leakage current
Output
Minimum load
Line regulation
Load regulation @ 10 to
100% load change
Temperature coefficient
EMI
85..264 VAC or 100..400 VDC
Power derating see diagram
47 .. 440 Hz
200 mA max @ 115 VAC
100 mA max @ 230 VAC
20 A @ 115 VAC
30 A @ 230 VAC
0.5 W, max.
1 A / 250 V slow blow
20 ms min. @ 115 VAC
80 ms min. @ 230 VAC
3000 VAC (1 minute, <5 mA)
100 MΩ
0.25 mA @ CY 1 nF / 400V
10 %
± 0.5 %, max.
± 1.5 %, max.
0.02 % / °C
Conducted emission
Radiation emission
ESD Electrostatic discharge
RS field susceptibility
EFT Fast transients on mains line
EMC
EMS
Surge
CS
PFM
Voltage dips,
short and interruptions immunity
Protection
Short circuit
Over current
Over temperature
General
Reliability MTBF@ 25°C
Switching frequency
Environmental
Operating temperature
(ambient)
Power derating
Storage temperature
Case surface temperature
Storage humidity
Cooling
Safety approvals
Physical
Dimensions
Weight
Case material
Mounting
Soldering temperature, Time
Continuous, auto recovery
110 % of full load
No
>300000 h
~100 kHz
-40 °C to +85 °C
(with derating, see diagram)
see diagram
-40 °C to +105 °C
100 °C, max.
85 %, max.
Free air convection
EN60950, UL60950
42 x 27 x 11 mm
10 g
UL94V-0
On PCB
Wave 265 °C max., 10 s max.
Manual 370 °C max., 5 s max.
EN55022 (CISPR22), class A (External circuit refer to fig. 2)
EN55022 (CISPR22), class B (External circuit refer to fig. 3)
EN55022 (CISPR22), class B (External circuit refer to fig. 2 and 3)
IEC, EN61000-4-2, contact ± 4 kV perf. criteria B
IEC, EN61000-4-3, 10 V/m perf. criteria A (External circuit refer to fig. 3)
IEC, EN61000-4-4, ± 2 kV, perf. criteria B (External circuit refer to fig. 2)
IEC, EN61000-4-4, ± 4 kV, perf. criteria B (External circuit refer to fig. 3)
IEC, EN61000-4-5, ± 1 kV perf. criteria B (External circuit refer to fig. 3)
IEC, EN61000-4-5, ± 2 kV perf. criteria B (External circuit refer to fig. 3)
IEC, EN61000-4-6, 3 Vrms perf. criteria A (External circuit refer to fig. 3)
IEC, EN61000-4-8, 10 A/m perf. criteria A
IEC, EN61000-4-11, 0…70 % perf. criteria B
1. External electrolytic capacitors are required to models. More details refer to typical applications.
2. Ripple and noise were measured refer to “ripple and noise measure configuration”.
3. All specifications were measured at Ta 25 °C, humidity <75 %, nominal input voltage (115 VAC or 230 VAC) and rated output load
unless otherwise specified.
4. In this datasheet, all the test methods of indications are based on corporate standards.
5. In applications with high vibration, the product need to be glued for fixing.
Page 1 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
5W AC-DC Power-Supply PAC5B
Functional diagram
Vin (N)
Vin (L)
1
Input
rectifier
3
14
+ Vout
Output
rectifier &
filter
DC/DCConverter
12
- Vout
5
C1
External
capacitor
7
Application note inadmissible connection
PAC5B
N
+Vout
-Vout
L
PE
This connection is not supported for the PAC5B series!
Ripple and noise measure configuration
PAC5B
N
L1
C3
C4
Load
14
+Vo
1
F1
L
C2
Measure points for
oscilloscope probe
-Vo
12
3
7 C1
5
CY
Figure 2 EMC application circuit for standard requirement, Class A
PAC5B
N
L
C2
F1
NTC
MOV
U
L1
C3
D1
C4 +Vout
-Vout
CX
C1
CY
For standard EMC requirement, please refer to figure 2, recommended parameters are shown in this table.
Type
F1
MOV
NTC
L1
CY
C1
C2
C3
PAC5B03S
120 µF
0.47 µH
470µF
PAC5B05S
1A
22 µF,
PAC5B09S
250V
Type
Type
1 nF,
68 µF
400 V
slow S14K350
5D-9
400 VAC
1 µH
PAC5B12S
35 V
330 µF
blow
PAC5B15S
100 µF
PAC5B24S
4.7 µH
C4
D1
SMBJ7.0A
0.1 µF
50 V
ceramic
SMBJ12A
SMBJ20A
SMBJ30A
Page 2 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
5W AC-DC Power-Supply PAC5B
Recommend PCB layout
Linewidth ≥3 mm, line to line distance ≥6 mm, line ground distance ≥6mm, undefined unit: mm
Figure 3, EMC application circuit for applications with higher EMC requirement, Class B
Complete input filter module PN: PIF003A
PAC5BxxS
L F1
L
LDM
C2
CY
MOV2
U
CX
L1
C3 D1 C4 +Vout
+
Rd
-Vout
CY
N
N
LCM
PE
C1
CY
For higher EMC requirement, please refer to figure 3, recommended parameters are shown in this table.
Type
F1
Filter module
CY
CX
C1
C2
C3
PAC5B03S
120 µF
470 µF
PAC5B05S
0.1 µF,
22 µF,
PAC5B09S
1 A, 250 V
1 nF,
PIF003A
68 µF
275 VAC
400 V
slow blow
400 VAC
PAC5B12S
35 V
330 µF
PAC5B15S
100 µF
PAC5B24S
C4
D1
SMBJ7.0A
0.1 µF
50 V
ceramic
SMBJ12A
SMBJ20A
SMBJ30A
Note:
C1, C2 and C3 are electrolytic capacitors. They are required both AC input and DC input. When AC input, C1 is used as filter
capacitor, the value of C1 is recommended to be 22 μF / 400 V. When DC input, C1 is used as EMC filter capacitor, the value
of C1 is recommended to be 10 μF / 400 V (when the input voltage is above 370 VDC, the recommended value of C1 is 10 μF /
450 V). C2 and C3 are output filter capacitors, they are recommended to be high frequency and low impedance electrolytic
capacitors. Capacitance and rated ripple current of capacitors refer to the data sheets provided by the manufactures. Voltage
derating of capacitors should be 80 % or above. C4 is a ceramic capacitor, which is used to filter high frequency noise. C2, C3
and L1 form a pi-type filter circuit. Current of L1 refer to the datas heets provided by the manufactures, current derating should
be 80% or above. TVS diode is a recommended component to protect post-circuits (if converter fails). External input NTC is
recommended to use 5D-9. External input MOV1 is recommended to use S14K350.
Page 3 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
5W AC-DC Power-Supply PAC5B
Page 4 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
5W AC-DC Power-Supply PAC5B
Dimensions
Pin
1
3
5
7
12
14
Pin connections
Function
AC In (N) or -Vin
AC In (L) or +Vin
+ Capacitor (C1)
- Capacitor (C1)
- DC Out
+ DC Out
Unit in mm
Pin section tolerance ± 0.1 mm
General tolerances ± 0.5 mm
PHI-CON is a trademark of HY-LINE Power Components.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for
use carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected
to result in significant injury to the user. Rev: 04.14 f
Page 5 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]