40W AC-DC Power-Supply PAC40C ● ● ● ● ● ● PCB-mountable plastic case 85 … 264 VAC or 120 … 370 VDC universal input range Continuously short circuit protected Over voltage protected Isolation class II 3 years product warranty Model guide Type Output voltage Output voltage tolerance PAC40C03S PAC40C05S PAC40C09S PAC40C12S PAC40C15S PAC40C24S [VDC] 3.3 5.0 9.0 12 15 24 typ. [%] ±2 ±2 ±2 ±2 ±2 ±2 Output current max. [mA] 8000 8000 4445 3335 2670 1670 Output power max [W] 26.4 40 40 40 40 40 Efficiency @ full load typ. [%] 78 82 84 84 84 84 Output load capacitance max. [µF] 60000 40000 12000 9000 7000 2000 Stand by consumption max. [W] 0.5 0.5 0.5 0.5 0.5 0.5 Specification Input Voltage range Line frequency range Full load input current Inrush current Recommended fuse Isolation Isolation voltage (input to output) Isolation resistance Output Voltage accuracy Line regulation Temperature coefficient Output voltage trim range Ripple & noise up to 20 MHz Load stability Minimum load Hold-up time Protection Short circuit Over current Over temperature Over voltage protection PAC40C3R3S PAC40C05S PAC40C09S PAC40C12S PAC40C15S PAC40C24S General Switching frequency Reliability MTBF@ 25°C 85..264 VAC or 120..370 VDC Power derating see diagram 47…440 Hz 1000 mA @ 115 VAC, typ. 600 mA @ 230 VAC, typ. 30 A typ. @ 115 VAC 50 A typ. @ 230 VAC 3.15 A / 250V slow blow EMC compliance EMI: Conducted & Radiation (EMC application circuit is required, see figure 2) ESD: Electrostatic discharge RS: field susceptibility EFT: 3000 VAC for 1 min. 8 10 Ω Surge: ±2% ± 0.5 % ± 0.02 % / °C 10 % max. 100 mV max. ±1% 1% 15 ms typ. @ 115 VAC 80 ms typ. @ 230 VAC Continuous, auto recovery 110 %, min. of full load 150 °C, max. 5.5 VDC max. 9 VDC max. 14 VDC max. 20 VDC max. 24 VDC max. 35 VDC max. 65 kHz typ. > 200000 h without external circuit with external circuit refer to figure 1 without external circuit with external circuit refer to figure 1 CS: PFM: Voltage dips, short and interruptions immunity Safety approvals Safety Environmental Operating temperature (ambient) Storage temperature Case temperature Humidity Cooling Physical Dimensions, PCB version Weight Case material Wave soldering temperature Manual soldering temperature Hot swap CE: EN55022 (CISPR22), class B RE: EN55022 (CISPR22), class B IEC-, EN61000-4-2, air ± 8 kV, contact ± 6 kV, perf. Criteria B IEC-, EN61000-4-3, 10 V / m, perf. Criteria A IEC-, EN61000-4-4, ± 2 kV, perf. Criteria B IEC-, EN61000-4-4, ± 4 kV, perf. Criteria B IEC, EN61000-4-5, ±1 kV / ± 2 kV, perf. Criteria B IEC, EN61000-4-5, ±2 kV / ± 4 kV, perf. Criteria B IEC, EN61000-4-6, 10 Vrms. perf. Criteria A IEC, EN61000-4-8, 10 A/m perf. Criteria A IEC, EN61000-4-11, 0...70 % perf. Criteria B EN60950, UL60950 Class II -40 °C to 70 °C (with derating) -40 °C to +85 °C 90 °C, max. 95 %, non-condensing Free air convection 89 x 63.5 x 25 mm 225 g UL94V-0 rated 260 ± 5 °C, 10 s max., 1.5 mm distance min. from case 360 ± 10 °C, 5 s max., 1.5 mm distance min. from case Not permissible! Page 1 of 5 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 40W AC-DC Power-Supply PAC40C Output ripple & noise measure circuit Conductor track L +Vo AC AC or DC line input Oscilloscope probe C1 C2 1 µF Cer. 10 µF Load DC -Vo N 12.7 Figure 1 12.7 25.4 unit mm Typical application circuit L F1 PAC40C R1 D1 +Vout C2 +Vo R2 U N C1 L ϑ -Vout -Vo N PE Figure 2 Application circuit and example for ripple and noise reduction L F1 R1 V L -ϑ Cy U V Cx +V out L1 C2 D1 -V out -V out U N N V PE PAC40C03S PAC40C05S PAC40C09S PAC40C12S PAC40C15S PAC40C24S C1 Cy U Model +V out Rd C1 Cer. cap. [µF] 1 1 1 1 1 1 C2 El. cap. [µF] 680 680 330 220 220 120 F1 Slow blow 250V~ fuse [A] 3.15 3.15 3.15 3.15 3.15 3.15 R1 NTC Rd V MOV D1 TVS Cy 400 V~ Cx 250 V~ type 5D-14 5D-14 5D-14 5D-14 5D-14 5D-14 [MΩ] 1 1 1 1 1 1 type S07K350 S07K350 S07K350 S07K350 S07K350 S07K350 type SMBJ7.0A SMBJ7.0A SMBJ12A SMBJ20A SMBJ20A SMBJ30A [nF] 2.2 2.2 2.2 2.2 2.2 2.2 [µF] 0.15 0.15 0.15 0.15 0.15 0.15 L1 Common mode [mH] 2.2 2.2 2.2 2.2 2.2 2.2 Note: 1. Output filtering capacitors C2 is a electrolytic capacitor. It is recommended to use high frequency and low impedance electrolytic capacitors. For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be 80 % or above. C1 is ceramic capacitor. It is used to filter high frequency noise. TVS is a recommended component to protect post-circuits in case of a converter failure. 2. For standard EMC requirement, please refer to figure 1. If higher an EMC requirement, please refer to figure 2. Page 2 of 5 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 40W AC-DC Power-Supply PAC40C Application note for trim option Trim down circuit Trim up circuit +Vout PAC40C R1 +Vout PAC40C Rtd - - R3 + R1 R3 + R2 VRef Rtu R2 VRef -Vout -Vout Calculation for trim down resistor (Rtd) or trim up resistor (Rtu) Model series R1 [kΩ] R2 [kΩ] R3 [kΩ] V Ref [V] PAC40Cxx03S 2 1.2 1 1.24 PAC40Cxx05S 3.3 3.3 1 2.5 PAC40Cxx09S 4.7 1.8 1 2.5 PAC40Cxx12S 3.83 1 1 2.5 PAC40Cxx15S 4.99 1 1 2.5 PAC40Cxx24S 8.66 1 1 2.5 Maximum output voltage adjust range ±10 % of Vout nominal, see min. Rtd / Rtu Trim down resistor formula b= Vout-Vref Rtd= Vref R1*b R1-b Rtd min. [kΩ] 9.28 12.2 27.4 24 36.2 64 Rtu min. [kΩ] 6.67 15.5 12.5 7.5 7.18 8.62 Trim up resistor formula *R2 a= -R3 Vref Vout-Vref Rtu= R2*a R2-a *R1 -R3 Page 3 of 5 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 40W AC-DC Power-Supply PAC40C Page 4 of 5 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 40W AC-DC Power-Supply PAC40C Dimensions Pin connection Pin 1 2 3 4 5 6 7 Pin configuration Input AC (L) Input AC (N) + V output No pin - V output No pin Trim input Unit: mm Pin diameter tolerance: ± 0.1 mm Pin length: > 6 mm General tolerances: ± 0.5 mm EMC optimized circuit PCB layout Recommend wiring: conductor tracke width A > 3 mm, safety distance B >9 mm PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for use carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 11.14 f Page 5 of 5 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]