40W AC-DC Power-Supply PAC40C
●
●
●
●
●
●
PCB-mountable plastic case
85 … 264 VAC or 120 … 370 VDC universal input range
Continuously short circuit protected
Over voltage protected
Isolation class II
3 years product warranty
Model guide
Type
Output voltage Output voltage
tolerance
PAC40C03S
PAC40C05S
PAC40C09S
PAC40C12S
PAC40C15S
PAC40C24S
[VDC]
3.3
5.0
9.0
12
15
24
typ. [%]
±2
±2
±2
±2
±2
±2
Output
current
max.
[mA]
8000
8000
4445
3335
2670
1670
Output
power
max
[W]
26.4
40
40
40
40
40
Efficiency @
full load
typ.
[%]
78
82
84
84
84
84
Output load
capacitance
max.
[µF]
60000
40000
12000
9000
7000
2000
Stand by
consumption
max.
[W]
0.5
0.5
0.5
0.5
0.5
0.5
Specification
Input
Voltage range
Line frequency range
Full load input current
Inrush current
Recommended fuse
Isolation
Isolation voltage (input to
output)
Isolation resistance
Output
Voltage accuracy
Line regulation
Temperature coefficient
Output voltage trim range
Ripple & noise up to 20 MHz
Load stability
Minimum load
Hold-up time
Protection
Short circuit
Over current
Over temperature
Over voltage protection
PAC40C3R3S
PAC40C05S
PAC40C09S
PAC40C12S
PAC40C15S
PAC40C24S
General
Switching frequency
Reliability MTBF@ 25°C
85..264 VAC or 120..370 VDC
Power derating see diagram
47…440 Hz
1000 mA @ 115 VAC, typ.
600 mA @ 230 VAC, typ.
30 A typ. @ 115 VAC
50 A typ. @ 230 VAC
3.15 A / 250V slow blow
EMC compliance
EMI: Conducted &
Radiation
(EMC application circuit is
required, see figure 2)
ESD: Electrostatic
discharge
RS: field susceptibility
EFT:
3000 VAC for 1 min.
8
10 Ω
Surge:
±2%
± 0.5 %
± 0.02 % / °C
10 % max.
100 mV max.
±1%
1%
15 ms typ. @ 115 VAC
80 ms typ. @ 230 VAC
Continuous, auto recovery
110 %, min. of full load
150 °C, max.
5.5 VDC max.
9 VDC max.
14 VDC max.
20 VDC max.
24 VDC max.
35 VDC max.
65 kHz typ.
> 200000 h
without external
circuit
with external circuit
refer to figure 1
without external
circuit
with external circuit
refer to figure 1
CS:
PFM:
Voltage dips, short and
interruptions immunity
Safety approvals
Safety
Environmental
Operating temperature
(ambient)
Storage temperature
Case temperature
Humidity
Cooling
Physical
Dimensions, PCB version
Weight
Case material
Wave soldering
temperature
Manual soldering
temperature
Hot swap
CE: EN55022 (CISPR22), class B
RE: EN55022 (CISPR22), class B
IEC-, EN61000-4-2, air ± 8 kV,
contact ± 6 kV, perf. Criteria B
IEC-, EN61000-4-3, 10 V / m,
perf. Criteria A
IEC-, EN61000-4-4, ± 2 kV,
perf. Criteria B
IEC-, EN61000-4-4, ± 4 kV,
perf. Criteria B
IEC, EN61000-4-5, ±1 kV /
± 2 kV, perf. Criteria B
IEC, EN61000-4-5, ±2 kV /
± 4 kV, perf. Criteria B
IEC, EN61000-4-6, 10 Vrms.
perf. Criteria A
IEC, EN61000-4-8, 10 A/m
perf. Criteria A
IEC, EN61000-4-11, 0...70 %
perf. Criteria B
EN60950, UL60950
Class II
-40 °C to 70 °C
(with derating)
-40 °C to +85 °C
90 °C, max.
95 %, non-condensing
Free air convection
89 x 63.5 x 25 mm
225 g
UL94V-0 rated
260 ± 5 °C, 10 s max.,
1.5 mm distance min. from case
360 ± 10 °C, 5 s max.,
1.5 mm distance min. from case
Not permissible!
Page 1 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
40W AC-DC Power-Supply PAC40C
Output ripple & noise measure circuit
Conductor track
L
+Vo
AC
AC or DC
line input
Oscilloscope probe
C1
C2
1 µF Cer.
10 µF
Load
DC
-Vo
N
12.7
Figure 1
12.7
25.4
unit mm
Typical application circuit
L
F1
PAC40C
R1
D1 +Vout
C2
+Vo
R2
U
N
C1
L
ϑ
-Vout
-Vo
N
PE
Figure 2
Application circuit and example for ripple and noise reduction
L
F1
R1
V
L
-ϑ
Cy
U
V
Cx
+V out
L1
C2
D1
-V out
-V out
U
N
N
V
PE
PAC40C03S
PAC40C05S
PAC40C09S
PAC40C12S
PAC40C15S
PAC40C24S
C1
Cy
U
Model
+V out
Rd
C1
Cer.
cap.
[µF]
1
1
1
1
1
1
C2
El.
cap.
[µF]
680
680
330
220
220
120
F1
Slow blow
250V~ fuse
[A]
3.15
3.15
3.15
3.15
3.15
3.15
R1
NTC
Rd
V
MOV
D1
TVS
Cy
400 V~
Cx
250 V~
type
5D-14
5D-14
5D-14
5D-14
5D-14
5D-14
[MΩ]
1
1
1
1
1
1
type
S07K350
S07K350
S07K350
S07K350
S07K350
S07K350
type
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
[nF]
2.2
2.2
2.2
2.2
2.2
2.2
[µF]
0.15
0.15
0.15
0.15
0.15
0.15
L1
Common
mode
[mH]
2.2
2.2
2.2
2.2
2.2
2.2
Note:
1. Output filtering capacitors C2 is a electrolytic capacitor. It is recommended to use high frequency and low impedance
electrolytic capacitors. For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of
capacitor should be 80 % or above. C1 is ceramic capacitor. It is used to filter high frequency noise. TVS is a recommended
component to protect post-circuits in case of a converter failure.
2. For standard EMC requirement, please refer to figure 1. If higher an EMC requirement, please refer to figure 2.
Page 2 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
40W AC-DC Power-Supply PAC40C
Application note for trim option
Trim down circuit
Trim up circuit
+Vout
PAC40C
R1
+Vout
PAC40C
Rtd
-
-
R3
+
R1
R3
+
R2
VRef
Rtu
R2
VRef
-Vout
-Vout
Calculation for trim down resistor (Rtd) or trim up resistor (Rtu)
Model series
R1 [kΩ]
R2 [kΩ]
R3 [kΩ]
V Ref [V]
PAC40Cxx03S
2
1.2
1
1.24
PAC40Cxx05S
3.3
3.3
1
2.5
PAC40Cxx09S
4.7
1.8
1
2.5
PAC40Cxx12S
3.83
1
1
2.5
PAC40Cxx15S
4.99
1
1
2.5
PAC40Cxx24S
8.66
1
1
2.5
Maximum output voltage adjust range ±10 % of Vout nominal, see min. Rtd / Rtu
Trim down resistor formula
b=
Vout-Vref
Rtd=
Vref
R1*b
R1-b
Rtd min. [kΩ]
9.28
12.2
27.4
24
36.2
64
Rtu min. [kΩ]
6.67
15.5
12.5
7.5
7.18
8.62
Trim up resistor formula
*R2
a=
-R3
Vref
Vout-Vref
Rtu=
R2*a
R2-a
*R1
-R3
Page 3 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
40W AC-DC Power-Supply PAC40C
Page 4 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
40W AC-DC Power-Supply PAC40C
Dimensions
Pin connection
Pin
1
2
3
4
5
6
7
Pin configuration
Input AC (L)
Input AC (N)
+ V output
No pin
- V output
No pin
Trim input
Unit: mm
Pin diameter tolerance: ± 0.1 mm
Pin length: > 6 mm
General tolerances: ± 0.5 mm
EMC optimized circuit PCB layout
Recommend wiring: conductor tracke width A > 3 mm, safety distance B >9 mm
PHI-CON is a trademark of HY-LINE Holding GmbH.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for
use carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to
result in significant injury to the user. Rev: 11.14 f
Page 5 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]