Download

1W SMD DC-DC Converter P1FS-Series
●
●
●
●
●
●
SMD package
Single output and dual output versions
Up to 3000 VDC isolation
MTBF > 3,500,000 h at 25°C
-40...85°C operating temperature range
Efficiency up to 79 %
Model guide
Model
Single output
P1FS3R33R3S
P1FS3R305S
P1FS0505S
P1FS0509S
P1FS0512S
P1FS0515S
P1FS123R3S
P1FS1205S
P1FS1209S
P1FS1212S
P1FS1215S
P1FS2405S
P1FS2412S
P1FS2415S
P1FS2424S
Dual output
P1FS3R312D
P1FS0505D
P1FS0509D
P1FS0512D
P1FS0515D
P1FS1205D
P1FS1209D
P1FS1212D
P1FS1215D
P1FS2405D
P1FS2412D
Input voltage
range
Output voltage
[VDC]
[VDC]
min.
[mA]
3..3.6
3..3.6
4.5..5.5
4.5..5.5
4.5..5.5
4.5..5.5
10.8..13.2
10.8..13.2
10.8..13.2
10.8..13.2
10.8..13.2
21.6..26.4
21.6..26.4
21.6..26.4
21.6..26.4
3.3
5.0
5.0
9.0
12.0
15.0
3.3
5.0
9.0
12.0
15.0
5.0
12.0
15.0
24.0
2.97..3.63
4.5..5.5
4.5..5.5
4.5..5.5
4.5..5.5
10.8..13.2
10.8..13.2
10.8..13.2
10.8..13.2
21.6..26.4
21.6..26.4
±12.0
±5.0
±9.0
±12.0
±15.0
±5.0
±9.0
±12.0
±15.0
±5.0
±12.0
Part designation structure
Output power
Series
designation
P1
1W
F
Mounting
technology
S
SMD
Efficiency typ.
Capacitive load
max.
max.
[mA]
Output
reflected ripple
& noise
[mVp-p]
[%]
[µF]
30
20
20
11
9
7
30
20
11
9
7
20
9
7
5
304
200
200
110
84
66
303
200
110
84
66
200
84
66
42
75..100
75..100
75..100
75..100
75..100
75..100
75..100
75..100
75..100
75..100
75..100
75..100
75..100
75..100
75..100
73
75
70
76
78
79
70
69
73
73
74
69
77
74
76
10
10
10
4.7
2.2
1
1
10
4.7
2.2
1
10
2.2
1
0.47
±5
±10
±6
±5
±4
±10
±6
±5
±4
±10
±5
±42
±100
±55
±42
±33
±100
±55
±42
±33
±100
±42
50..75
50..75
50..75
50..75
50..75
50..75
50..75
50..75
50..75
50..75
50..75
77
71
77
78
79
71
73
74
75
70
77
2x1
2 x 4.7
2 x 2.2
2x1
2x1
2 x 4.7
2 x 2.2
2x1
2x1
2 x 4.7
2x1
Output current
Input voltage
Output voltage
3R3
05
12
24
3R3
05
09
12
15
24
3.3 V
5V
12 V
24 V
3.3 V
5V
9V
12 V
15 V
24 V
Output
configuration
D
dual
S
single
Packing
blank
TR
Tube
Reel
Page 1 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
1W SMD DC-DC Converter P1FS-Series
Specifications
Input
Voltage range
Filter
Input / output:
Isolation voltage tested for 60 sec.
@ leakage current < 1mA
Isolation resistance @ 500 VDC
Capacitance
Output
Output voltage drift @ 3.3V Vout models
Output voltage drift @ all other models
Output voltage drift @
10 % to 100 % load change
3.3 V output version
5 V output version
9 V output version
12 V output version
15 V output version
24 V output version
Temperature coefficient
Short circuit duration
General
Switching frequency
Environmental
Operating temperature (ambient)
Case temperature
Storage temperature
Derating
Cooling
Case temperature rise at full load
Humidity
± 10 % of nominal
Capacitors
3 kVDC
109 Ω, min.
30 pF, typ.
100 pF, typ. @ P1FS2424Dx
± 1.5 % @ 1% Vin change
± 1.2 % @ 1% Vin change
15 % typ., 20 % max.
12.8 % typ., 15 % max.
8.3 % typ., 10 % max.
6.8 % typ., 10 % max.
6.3 % typ., 10 % max.
6 % typ., 10 % max.
0.03 % / °C, max., at full load
1 sec., max.
~ 100 kHz, 3.3, 5, 12 Vin Types
~ 500 kHz, 24 Vin Types
Physical
Package material
Weight
Reliability, MTBF
(MIL-HDBK-217 @ 25 °C)
Absolute maximum ratings
Vin 3.3 V types
Vin 5 V types
Vin 12 V types
Vin 15 V types
Vin 24 V types
Manual soldering lead
temperature
Soldering temperature
Moisture sensitivity level (MSL)
-40 °C to +85 °C
95 °C, max.
-55 °C to +125 °C
None required
Free-air convection
15…25 °C
Up to 95 %,
non-condensing
Epoxy resin (UL94-V0)
1.71 g
3.5 Mio. hours
-0.7 ~ 5 VDC, max. 1 s
-0.7 ~ 9 VDC, max. 1 s
-0.7 ~ 15 VDC, max. 1 s
-0.7 ~ 21 VDC, max. 1 s
-0.7 ~ 30 VDC, max. 1 s
300 °C max. 10 s max., 1.5 mm
distance from body
217 °C for 60 s max., 245 °C peak
IPC/JEDEC J-STD-020D.1
Fig. 1 External circuit to decreace the input and output ripple & noise
+ Vin
L
L
+ Vout
+ Vin
L
L
+ Vout
Cout
Com
Cin
- Vin
Cin
Cout
Cout
- Vout
- Vin
L
- Vout
Table 1 Filter components to figure 1
Input components
Vin version
Cin
L
3.3 V
4.7 µF, 50 V
6.8 µH
5V
4.7 µF, 50 V
6.8 µH
12 V
2.2 µF, 50 V
6.8 µH
24 V
1 µF, 50 V
6.8 µH
Output components
Vout version
Cout
L
3.3 V
10 µF, 50 V
6.8 µH
5V
10 µF, 50 V
6.8 µH
9V
4.7 µF, 50 V
6.8 µH
12 V
2.2 µF, 50 V
6.8 µH
15 V
1 µF, 50 V
6.8 µH
24 V
1 µF, 50 V
6.8 µH
±3.3 V
4.7 µF, 50 V
6.8 µH
±5 V
4.7 µF, 50 V
6.8 µH
±9 V
2.2 µF, 50 V
6.8 µH
±12 V
1 µF, 50 V
6.8 µH
±15V
1 µF, 50 V
6.8 µH
It’s not recommended to connect any external
capacitor in the application field with less than
0.5 watt output load.
Page 2 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
1W SMD DC-DC Converter P1FS-Series
Page 3 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
1W SMD DC-DC Converter P1FS-Series
Application note
1) Requirement on output load
To ensure this module can operate efficiently and reliably during operation, the minimum output load must be higher than 10% of
the full load. If the actual output power is very small, please connect a resistor with proper resistance at the output end in parallel to
increase the load, or use our company’s products with a lower rated output power. Operation with smaller load than minimum load
will not damage the converter. However, they may not meet all specification listed, and that will reduce the life time of product.
2) Recommended testing circuit
If you want to further decrease the input / output ripple, an “LC” filtering network may be connected to the input and output ends of
the DC/DC converter, see (Figure 1).
It should also be noted that the inductance and the frequency of the “LC” filtering network should be staggered with the DC/DC
frequency to avoid mutual interference. However, the capacitance of the output filter capacitor must be proper. If the capacitance is
too big, a start up problem might arise. To ensure safe and reliable operation, the capacitance of the output filter for each output
channel may not exceed certain values (see Table 1 on page 2).
3) Output Voltage Regulation and Over-voltage Protection Circuit
The simplest device for output voltage regulation, over voltage and over current protection is a linear voltage regulator with overheat
protection that is connected to the input or output end in series.
4) Overload Protection
Under normal operating conditions, the output circuit of these products has no protection against overload. The simplest method is
to connect a self recovery fuse in series at the input end or add a circuit breaker to the circuit.
5) No parallel connection or plug and play !
Dimensions
Lead
1
2
3
4
5
6
7
8
9
10
11
12
Single output
version
- Vinput
+ Vinput
Not connected
No Pin
- Voutput
Not connected
Not connected
+ Voutput
No Pin
Not connected
Not connected
Not connected
Dual output
version
- Vinput
+ Vinput
Not connected
No Pin
common output
- Voutput
Not connected
+ Voutput
No Pin
Not connected
Not connected
Not connected
Page 4 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
1W SMD DC-DC Converter P1FS-Series
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions
carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without
the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and
whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably
expected to result in significant injury to the user. Rev: 06.14 f
Page 5 of 5
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]