Download

25W AC-DC Power-Supply PAC25C
●
●
●
●
●
●
●
PCB-mountable plastic case
85 … 264 VAC or 120 … 370 VDC universal input range
Continuously short circuit protected
Over voltage protected
Isolation class II
MTBF > 300000 hrs
3 years product warranty
Model selection guide
Type
Output voltage
PAC25C03S
PAC25C05S
PAC25C09S
PAC25C12S
PAC25C15S
PAC25C24S
PAC25C48S
[VDC]
3.3
5.0
9.0
12
15
24
48
Output voltage
tolerance
[%] typ.
±2
±2
±2
±2
±2
±2
±2
Output current Output power
[mA] max.
4100
4100
2500
2100
1600
1100
500
[W] max.
13.5
20.5
22.5
25
25
25
25
Efficiency @
full load
[%] typ.
73
74
78
82
83
85
87
Capacitive
load
[µF] max.
48000
12000
5600
5400
2400
1440
800
Specification
Input
Voltage range
Line frequency range
Full load input current
Inrush current
Recommended fuse
Isolation
Isolation voltage (input to
output)
Leakage current
Isolation resistance
Output
Voltage accuracy
Line regulation
Temperature coefficient
Ripple & noise up to 20 MHz
Output load stability @ load
change 10 to 100%
Minimum load
Hold-up time
85..264 VAC or 120..370 VDC
Power derating see diagram
47…63 Hz
600 mA @ 115 VAC, typ.
340 mA @ 230 VAC, typ.
16 A typ. @ 115 VAC
30 A typ. @ 230 VAC
3.15 A / 250V slow blow
3000 VAC for 1 min.
0.3 mA typ. @
Vin 230 VAC , 50 Hz
8
10 Ω
±2%
± 0.5 %
± 0.02 % / °C, typ.
150 mV max.
±1%
not required
15 ms typ. @ 115 VAC
80 ms typ. @ 230 VAC
Protection
Short circuit
Continuous, auto recovery
Over current
110 %, min. of full load
Over temperature
150 °C, max.
Output over voltage protection
PAC25C03S, PAC25C05S
7.5 VDC max.
PAC25C09S
12 VDC max.
PAC25C12S, PAC25C15S
20 VDC max.
PAC25C24S
30 VDC max.
PAC25C48S
60 VDC max.
General
Switching frequency
65 kHz typ.
Reliability MTBF@ 25°C
> 300000 h
EMC compliance
EMI: Conducted & Radiation
(EMC application circuit is
required, see figure 2)
ESD: Electrostatic discharge
RS: field susceptibility
EFT: Fast transients on
mainsline
Surge: External circuit is
required to converter at
inrush and fast transient test,
refer to typical application!
Safety approvals
Safety
Environmental
Operating temperature
(ambient)
Storage temperature
Case temperature
Power derating above 55°C
and below 0°C
Humidity
Cooling
Physical
Dimensions, PCB version
Weight
Case material
Wave soldering temperature
CE: EN55011 (CISPR22), class B
RE: EN55011 (CISPR22), class B
IEC-, EN61000-4-2, air ± 8 kV,
contact ± 6 kV, perf. Criteria B
IEC-, EN61000-4-3, 10 V / m perf.
Criteria A
IEC-, EN61000-4-4, ± 4 kV, perf.
Criteria B
IEC, EN61000-4-5, ±2 kV / ± 4 kV,
perf. Criteria B
EN60950, UL60950
Class I
-40 °C to 70 °C
(with derating)
-40 °C to +105 °C
90°C, max.
3.75 % per °C, see diagram
95 %, non-condensing
Free air convection
70 x 48 x 23.5 mm
120 g
UL94V-0 rated
260 ± 5 °C, 10 s max.,
1.5 mm distance min. from case
Manual soldering temperature 360 ± 10 °C, 5 s max.,
1.5 mm distance min. from case
Hot swap
Not permissible!
Page 1 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
25W AC-DC Power-Supply PAC25C
Output ripple & noise measure circuit
Conductor track
Oscilloscope probe
L
AC
line
voltage
AC
DC
N
PE
C1
C2
10µF
100nF
25.4mm
Typical application
L
F1
L
C1
D1 +Vout
C2
+Vo
R2
U
N
25.4mm
PAC25C
R1
ϑ
Figure 1
Load
-Vout
-Vo
N
PE
PE
Application circuit and example for ripple and noise reduction
L
PAC25C
L1
Rs
F1
L
Cy
Cy
Figure 2
V
Cy
Cx
+V out
Rd
+V out
Cy
PE
U
C1
C2
D1
-V out
-V out
Rs
N
N
PE
Model
PAC25C3R3S
PAC25C05S
PAC25C09S
PAC25C12S
PAC25C15S
PAC25C24S
C1
Cer.
cap.
[µF]
1
1
1
1
1
1
C2
Elyt
[µF]
330
330
220
220
220
220
F1
Slow blow
fuse
R1
NTC
type
Rs
Rd
[MΩ]
V
MOV
type
D1
TVS
type
[Ω]
3.15A / 250V~
3.15A / 250V~
3.15A / 250V~
3.15A / 250V~
3.15A / 250V~
3.15A / 250V~
5D-9
5D-9
5D-9
5D-9
5D-9
5D-9
2
2
2
2
2
2
1
1
1
1
1
1
S14K350
S14K350
S14K350
S14K350
S14K350
S14K350
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
Cy
400
V~
[nF]
1
1
1
1
1
1
Cx
250
V~
[µF]
0.1
0.1
0.1
0.1
0.1
0.1
L1
Common
mode
[mH]
10 … 30
10 … 30
10 … 30
10 … 30
10 … 30
10 … 30
Note:
1. Output filtering capacitor C1 is a ceramic capacitor, it is used to filter high frequency noise. C2 is an electrolytic capacitor. It is
recommended to use high frequency and low impedance electrolytic capacitor. For capacitance and current please refer to
datasheet of capacitor manufacturer. Voltage derating of capacitor should be 80 % or above. TVS D1 is a recommended component
to protect post-circuits, if converter fails.
2. The serial resistors Rs protect the device under surge.
3. Recommended fuse parameter for F1 are 3.15A / 250 V slow blow. An external input NTC limited the inrush current.
Recommended NTC is the type 5D-9, see figure 1.
4. For EMC performance “EN55011 Class A”, refer to figure 1.
For EMC performance “EN55011 Class B”, refer to figure 2.
Cx: X capacitor, recommended values 0.1 μF / 275 VAC;
Cy: Y capacitor, recommended values 1 nF / 400 VAC;
L1: Common mode choke, recommended inductance is about 10 mH – 30 mH.
Page 2 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
25W AC-DC Power-Supply PAC25C
Page 3 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
25W AC-DC Power-Supply PAC25C
Dimensions
Pin connection
Pin
1
2
3
4
5
6
7
8
9
Pin configuration
omitted
Input AC (N)
Input AC (L)
- V output
omitted
omitted
omitted
+ V output
Trim input
Unit: mm
Pin diameter tolerance: ± 0.1 mm
Pin length: >6 mm
General tolerances: ± 0.5 mm
EMC optimized circuit PCB layout
Recommend wiring: conductor tracke width A > 3 mm, safety distance B >9 mm
PHI-CON is a trademark of HY-LINE Power Components.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for
use carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to
result in significant injury to the user. Rev: 09.14 f
Page 4 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]