10W DC-DC Converter P10E-Series ● ● ● ● ● ● ● ● Wide 2:1 input range 1500 VDC Isolation MTBF >1 Mio. hours Continuous short circuit protection Output over voltage protection Efficiency up to 90 % Soft Start Low self power consumption Model guide Type Single output P10E122R5S P10E123R3S P10E1205S P10E1212S P10E1215S P10E242R5S P10E243R3S P10E2405S P10E2412S P10E2415S P10E482R5S P10E483R3S P10E4805S P10E4812S P10E4815S Dual output P10E1212D P10E1215D P10E2412D P10E2415D P10E4812D P10E4815D Input voltage range [VDC] Input current no load [mA] typ. Input current full load Output voltage Over voltage protection [V] typ. Output current Efficiency Capacitive load (see note 4) [VDC] nom. Regulation at 0…100% load change [%] max. [mA] typ. [mA] max. [%] typ. [µF] max. 9...18 9...18 9...18 9...18 9...18 18...36 18...36 18...36 18...36 18...36 36...75 36...75 36...75 36...75 36...75 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 790 1005 990 980 960 380 500 480 485 485 190 250 240 245 240 2.5 3.3 5.0 12.0 15.0 2.5 3.3 5.0 12.0 15.0 2.5 3.3 5.0 12.0 15.0 ±1 ±1 ± 0.5 ± 0.5 ± 0.5 ±1 ±1 ± 0.5 ± 0.5 ± 0.5 ±1 ±1 ± 0.5 ± 0.5 ± 0.5 3.9 3.9 6.2 15 18 3.9 3.9 6.2 15 18 3.9 3.9 6.2 15 18 3000 3000 2000 833 667 3000 3000 2000 833 667 3000 3000 2000 833 667 81 84 86 87 89 84 85 89 88 88 84 85 88 87 88 2200 2200 2200 820 470 2200 2200 2200 820 470 2200 2200 2200 820 470 9...18 9...18 18...36 18...36 36...75 36...75 10 10 10 10 10 10 980 970 485 475 245 245 ±12.0 ±15.0 ±12.0 ±15.0 ±12.0 ±15.0 ±1 ±1 ±1 ±1 ±1 ±1 ±15 ±18 ±15 ±18 ±15 ±18 ±416 ±333 ±416 ±333 ±416 ±333 87 88 88 90 87 87 2 x 220 2 x 150 2 x 220 2 x 150 2 x 220 2 x 150 Specifications Input Start up time (@Vin nom. & constant R-load) Filter Input reflected ripple current Output Voltage accuracy Voltage balance (dual outputs) Cross regulation @ dual output Temperature coefficient Line voltage regulation Transient recovery time Transient response deviation Ripple and noise (at 20 MHz BW) Short circuit protection Over current limiting Isolation: Input to output isolation voltage Input / output to case isolation voltage Resistance Capacitance General Switching frequency Reliability calculated MTBF (MIL-HDBK 217 F) Safety Standard 20 ms, typ. Pi Network 20 mAp-p, typ. (see note 6) ± 1 %, max. ±1% ± 5 % (see note 2) ± 0.02 % / °C ± 0.5 %, max. 200 µs typ. (see note 5) ±3 % (see note 5) 75 mVp-p, max. (see note 3) Continuous, Automatic restart 150 % of Iout max. 1500 VDC (flash tested 3 s) 1000 VDC 109 Ω 1000 pF, typ. 330 kHz, typ. 1 Mio. hours EMC Radiated emissions Conducted emissions (see note 9) ESD RS EFT Surge (see note 8) CS PFMF Environmental Operating temperatur (ambient) Case temperature Storage temperature Derating Humidity Cooling Physical Dimensions Weight Case material Potting material Absolute maximum ratings Input voltage surge 100 ms max. Pin soldering temperature 1.5 mm distance from body EN55022 class A EN55022 class A IEC61000-4-2 perf. criteria A IEC61000-4-3 perf. criteria A IEC61000-4-4 perf. criteria A IEC61000-4-5 perf. criteria A IEC61000-4-6 perf. criteria A IEC61000-4-8 perf. criteria A -40 °C to +85 °C (see SOA) 100 °C, max. -40 °C to +125 °C see SOA diagram Up to 95%, non condensing Free air convection 31.75 x 20.32 x 10.16 mm 17 g Nickel coated copper Epoxy (UL94V-0 rated) P10E12xxxx – 0.7..25 VDC P10E24xxxx – 0.7..50 VDC P10E48xxxx – 0.7..100 VDC 260 °C, max. IEC 60950 Page 1 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 10W DC-DC Converter P10E-Series Note: 1. 2. 3. 4. 5. 6. 7. 8. All specifications are typical at 25 °C, nominal input voltage and full load unless otherwise noted. One output is 25 % to 100 % burdened, the other output is 100 % burdened. The output voltage deviation can be ± 5 %. Measured with 20 MHz bandwidth and 1 µF ceramic capacitor. Tested by minimal Vin and constant resistive load. Tested by nominal Vin and 75 % to 25 % load at 25 % load step change. Measured input reflected ripple current with a simulated source inductance of 12 µH and source capacitance of 47 µF, ESR <1 Ω at 100 kHz. (see Figure 2) Exceeding the absolute ratings of the converter could cause damage. It is not allowed for continuous operatin ratings. An external filter capacitor is required if the module has to meet IEC61000-4-5.Suggested is a value of 220 µF / 100 V of Nippon Chemicon’s KY-Series.Input filter components C1 and L1 are be required to help meet conducted emissions requirement for the module. These components should be mounted as close as possible to the module and all leads should be minimized to decrease radiated noise. Filter circuit to meet IEC61000-4-5, see note 9 + Vin L1 12 µH C1 100 µF ESR <1Ω at 100 kHz Load - Vin Figure 2 Input reflected ripple current measure circuit Input reflected current is measured through a source inductor and a source capacitor at nominal input voltage and full load. Figure 1 Output ripple & noise measurement test method Use the following measurement circuit. The oscilloscope mesurement bandwidth must be > 20 MHz. Oscilloscope current probe + Vin +Vou 12 µH DC/DC-Converter -Vout Cout 1 µF Resistive load Measure points for oscilloscope Measure point 47 µF ESR <1Ω at 100 kHz Load - Vin Page 2 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 10W DC-DC Converter P10E-Series Efficiency diagrams Page 3 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 10W DC-DC Converter P10E-Series Dimensions Pin 2 3 9 11 14 16 22 23 Standard Single Dual -V Input -V Input -V Input -V Input Omitted Common N.C. -V Output +V Output +V Output -V Output Common +V Input +V Input +V Input +V Input PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 12.14 f Page 4 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]