Download

10W DC-DC Converter P10C-Series
●
●
●
●
●
●
●
●
10 W Output Power
4:1 Wide Input Voltage Range
Optional Remote Control Input
International Safety Standard
Six-Sided Continuous Shield
High Efficiency up to 84%
Standard 2" X 1" X 0.4" Package
Fixed Switching Frequency
Model selection guide
Typ
Input
nominal
voltage
[VDC]
Single output
P10C24S33W
P10C24S05W
P10C24S12W
P10C24S15W
P10C48S33W
P10C48S05W
P10C48S12W
P10C48S15W
Dual output
P10C24D05W
P10C24D12W
P10C24D15W
P10C48D05W
P10C48D12W
P10C48D15W
Input
current
full-load
[mA]
Output
voltage
Output
current
Efficiency
typ.
Capacitor
load max.
Output
over
voltage
protection
[V]
[VDC]
[mA]
[%]
[uF]
9...36
9...36
9...36
9...36
18...75
18...75
18...75
18...75
465
548
532
551
239
274
259
262
3.3
5
12
15
3.3
5
12
15
2500
2000
830
670
2500
2000
830
670
78
80
82
80
76
80
84
84
6800
4700
680
470
6800
4700
680
470
3.9
6.2
15
18
3.9
6.2
15
18
9...36
9...36
9...36
18...75
18...75
18...75
548
547
548
271
281
270
±5
±12
±15
±5
±12
±15
±1000
±416
±333
±1000
±416
±333
80
80
80
81
78
81
2 x 680
2 x 330
2 x 110
2 x 680
2 x 330
2 x 110
6.2
15
18
6.2
15
18
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
10W DC-DC Converter P10C-Series
Specifications
Input
Voltage range
Filter
Start up time @ R-load
Input surge voltage for
100mS max.
Remote CTRL (Option)
Positive logic Suffix “P”
Negative logic Suffix “N”
On: open or 3.5..12 VDC
Off: 0...1.2 VDC
On: 0...1.2 VDC
Off: open or 3.5..12 VDC
Remote CTRL input current
Remote CTRL input reference
Remote off, Input current
Output
Power
Voltage accuracy
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Line voltage regulation
Load voltage regulation
-2.5mA
-Input
20mA
Temperature coefficient
Minimum load
General
Efficiency
Switching frequency
Isolation voltage
Isolation Leakage current
Isolation Resistance
Isolation Capacitance
Standard in accordance with
P10C: 9...36, 18...75 VDC
π Pi type
20ms typ.
24V type : 50 VDC max.
48V type : 100 VDC max.
MTBF
Bellcore TR-NWT-000332
Environmental
Operating temperature
10W max
± 2%
Single type: 50mVp-p
Dual type: 75mVp-p
Hiccup, automatics recovery
± 0.2%
single: ± 0.5%
dual: ±1%
± 0.02% / °C
10% to maintain the specified
regulation
Dimensions
Option “-M1”
Option “-M2” (W-series)
Storage temperature
Maximum case temp.
Humidity
Cooling
Physical
Dimensions
Weight
Case material
See table
300 kHz, typ.
1600 VDC
1 mA
9
10 Ω
300 pF, typ.
EN60950-1, IEC60950-1,
UL60950-1
@Ta 40°C, 50% stress:
6
1.976x10 hrs
-25 °C to +85 °C
(standard, derating)
-40 °C to +85 °C (no derating)
-40 °C to +85 °C (with derating)
-55 °C to +105 °C
+100 °C
5% to 95% RH
Free-air convection
1 x 2 x 0.4 inches
50.8 x 10.2 x 25.4 mm
27 g
Nickel-coated copper
Derating
All dimensions in inches (mm)
Pin Pitch tolerance ±0.014 (0.35)
Pin connections
Pin
1
2
3
4
5
6
Standard
Single
Dual
+ Input
+ Input
- Input
- Input
+ Output
+ Output
No Pin
Common
- Output
- Output
CTRL (Option)
CTRL (Option)
Life Support Policy: HY-LINE does not authorize the use of any
of its products for use in life support devices or systems without
the express written approval of an officer of the Company. Life
support systems are devices which support or sustain life, and
whose failure to perform, when properly used in accordance with
instructions for use provided in the labeling, can be reasonably
expected to result in significant injury to the user.
Rev: 9 / 05 f
Page 2 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00