25&30W DC-DC Converter P30C-Series
●
●
●
●
●
●
●
●
●
●
High efficiency up to 91%
2:1 wide input voltage range
Over current protection
Over voltage protection
Over temperature protection
Continuous short circuit protection
Adjustable output voltage
On/Off - remote control input
Soft start
Standard 2" x 1.6" x 0.4" package
Model selection guide
Typ
Input voltage
range
[VDC]
Single output
P25C123R3S
P25C1205S
P30C1212S
P30C1215S
P25C243R3S
P25C2405S
P30C2412S
P30C2415S
P25C483R3S
P25C4805S
P30C4812S
P30C4815S
Dual output
P30C1212D
P30C1215D
P30C2412D
P30C2415D
P30C4812D
P30C4815D
Input current
no-load
full-load
[mA]
[mA]
Output
voltage
[VDC]
Output current
range
[mA]
+ 330µF
< 90 mΩ
[%]
Capacitor load
max.
[µF]
9...18
9...18
9...18
9...18
18...36
18...36
18...36
18...36
36...75
36...75
36...75
36...75
30
30
30
30
25
25
25
25
20
20
20
20
1867
2480
2850
2850
922
1220
1400
1400
460
610
700
700
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
0…5500
0…5000
0…2500
0…2000
0…5500
0…5000
0…2500
0…2000
0…5500
0…5000
0…2500
0…2000
83
86
90
90
84
87
91
91
84
87
91
91
15000
10000
2200
1000
15000
10000
2200
1000
15000
10000
2200
1000
9...18
9...18
18...36
18...36
36...75
36...75
30
30
25
25
20
20
2850
2850
1400
1400
710
710
±12
±15
±12
±15
±12
±15
0…±1250
0…±1000
0…±1250
0…±1000
0…±1250
0…±1000
90
90
91
91
90
90
2 x 1000
2 x 680
2 x 1000
2 x 680
2 x 1000
2 x 680
Circuit diagram
+ INPUT
Efficiency typ.
The output voltage can be
externally trimmed by using the
method shown below.
( ) for dual output trim
L: 12µH
100µF
100V
1
5 (4)
+ OUTPUT
Remote
ON
R - Trim down
3
Remote
OFF
2
DC/DC - Converter
7 (7)
P25&30Cxxxxx
CL
See table
6 (6)
R - Trim up
- OUTPUT
- INPUT
Y-capacitor 1nF, 2kV
Page 1 of 2
Deutschland:
Inselkammerstrasse 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
25&30W DC-DC Converter P30C-Series
Specifications
Input
Input Filter:
Under voltage lockout
Input surge voltage
100 ms max.
Start up time
input current remote "off"
Isolation
Isolation voltage
Resistance
Capacitance
Output
over voltage protection with
Z-diode clamp
Voltage accuracy
Voltage adjustability
Minimum load
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Line voltage regulation
Load voltage regulation
Cross regulation @ dual
output
Temperature coefficient
Transient response recovery time
Over load protection
Pi- type
12V Type: on @ 8.6V, off @ 7.9V
24V Type: on @ 17.6V, off @ 16V
48V Type: on @ 33.5V, off @ 30.5V
12 V input : -0.7…25 VDC
24 V input : -0.7…50 VDC
48 V input : -0.7…100 VDC
20ms typ.
2.5mA @ nominal Vin
Input to output 1500 VDC, 3sec.
9
10 Ω, min
1200 pF, max
3.3V-output-type 3.9V
5V-output-type 6.2V
(±)12V-output-type 15V (±15V)
(±)15V-output-type 18V (±18V)
±1%
±10%
0%
75mVp-p
Hiccup, automatics recovery
± 0.5%
±0.5% @ 10…100% load
±5%
± 0.02% / °C
200µs
120% typ. of full load
General
Switching frequency
Standard in accordance with
Conducted and radiated emissions
ESD
Radiated immunity
Fast transient
Surge
Conducted immunity
PFMF
MTBF
Environmental
Operating temperature
Over temperature protection
Storage temperature
Maximum case temp.
Humidity
Thermal impedance
Thermal shock
Vibration
Physical
Dimensions
Weight
Case material
Potting material
Soldering temperature
Note
Remote control on
Remote control off
270 kHz, typ.
IEC 60950-1
EN60950-1
EN55022 level A
EN61000-4-2 pref. criteria B
EN61000-4-3 pref. criteria A
EN61000-4-4 pref. criteria A
EN61000-4-5 pref. criteria A
EN61000-4-6 pref. criteria A
EN61000-4-8 pref. criteria A
>1 Mhrs
-40°C to +85°C (with derating)
110°C
-55 °C to +125 °C
+100 °C
95% rel. Humidity
Free-air convection 10°C/W
MIL-STD-810D
10...55Hz, 10G, 30Min. X,Y,Z
50.8 x 40.6 x 10.2 mm
48 g
Nickel-coated copper
Epoxy ( UL94-V0)
260°C, 10s, 1.5mm from case
Open input or 2.5V…5.5V
Short to –Vin or 0V…0.8V
Dimensions
Pin connections
Pin
1
2
3
4
5
6
7
Single
+ Input
- Input
CTRL
No Pin
+ Output
- Output
Trim
Dual
+ Input
- Input
CTRL
+ Output
Common
- Output
Trim
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected
to result in significant injury to the user. Rev: 2/09 f