25&30W DC-DC Converter P30C-Series ● ● ● ● ● ● ● ● ● ● High efficiency up to 91% 2:1 wide input voltage range Over current protection Over voltage protection Over temperature protection Continuous short circuit protection Adjustable output voltage On/Off - remote control input Soft start Standard 2" x 1.6" x 0.4" package Model selection guide Typ Input voltage range [VDC] Single output P25C123R3S P25C1205S P30C1212S P30C1215S P25C243R3S P25C2405S P30C2412S P30C2415S P25C483R3S P25C4805S P30C4812S P30C4815S Dual output P30C1212D P30C1215D P30C2412D P30C2415D P30C4812D P30C4815D Input current no-load full-load [mA] [mA] Output voltage [VDC] Output current range [mA] + 330µF < 90 mΩ [%] Capacitor load max. [µF] 9...18 9...18 9...18 9...18 18...36 18...36 18...36 18...36 36...75 36...75 36...75 36...75 30 30 30 30 25 25 25 25 20 20 20 20 1867 2480 2850 2850 922 1220 1400 1400 460 610 700 700 3.3 5 12 15 3.3 5 12 15 3.3 5 12 15 0…5500 0…5000 0…2500 0…2000 0…5500 0…5000 0…2500 0…2000 0…5500 0…5000 0…2500 0…2000 83 86 90 90 84 87 91 91 84 87 91 91 15000 10000 2200 1000 15000 10000 2200 1000 15000 10000 2200 1000 9...18 9...18 18...36 18...36 36...75 36...75 30 30 25 25 20 20 2850 2850 1400 1400 710 710 ±12 ±15 ±12 ±15 ±12 ±15 0…±1250 0…±1000 0…±1250 0…±1000 0…±1250 0…±1000 90 90 91 91 90 90 2 x 1000 2 x 680 2 x 1000 2 x 680 2 x 1000 2 x 680 Circuit diagram + INPUT Efficiency typ. The output voltage can be externally trimmed by using the method shown below. ( ) for dual output trim L: 12µH 100µF 100V 1 5 (4) + OUTPUT Remote ON R - Trim down 3 Remote OFF 2 DC/DC - Converter 7 (7) P25&30Cxxxxx CL See table 6 (6) R - Trim up - OUTPUT - INPUT Y-capacitor 1nF, 2kV Page 1 of 2 Deutschland: Inselkammerstrasse 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 25&30W DC-DC Converter P30C-Series Specifications Input Input Filter: Under voltage lockout Input surge voltage 100 ms max. Start up time input current remote "off" Isolation Isolation voltage Resistance Capacitance Output over voltage protection with Z-diode clamp Voltage accuracy Voltage adjustability Minimum load Ripple and noise (at 20 MHz BW) Short circuit protection Line voltage regulation Load voltage regulation Cross regulation @ dual output Temperature coefficient Transient response recovery time Over load protection Pi- type 12V Type: on @ 8.6V, off @ 7.9V 24V Type: on @ 17.6V, off @ 16V 48V Type: on @ 33.5V, off @ 30.5V 12 V input : -0.7…25 VDC 24 V input : -0.7…50 VDC 48 V input : -0.7…100 VDC 20ms typ. 2.5mA @ nominal Vin Input to output 1500 VDC, 3sec. 9 10 Ω, min 1200 pF, max 3.3V-output-type 3.9V 5V-output-type 6.2V (±)12V-output-type 15V (±15V) (±)15V-output-type 18V (±18V) ±1% ±10% 0% 75mVp-p Hiccup, automatics recovery ± 0.5% ±0.5% @ 10…100% load ±5% ± 0.02% / °C 200µs 120% typ. of full load General Switching frequency Standard in accordance with Conducted and radiated emissions ESD Radiated immunity Fast transient Surge Conducted immunity PFMF MTBF Environmental Operating temperature Over temperature protection Storage temperature Maximum case temp. Humidity Thermal impedance Thermal shock Vibration Physical Dimensions Weight Case material Potting material Soldering temperature Note Remote control on Remote control off 270 kHz, typ. IEC 60950-1 EN60950-1 EN55022 level A EN61000-4-2 pref. criteria B EN61000-4-3 pref. criteria A EN61000-4-4 pref. criteria A EN61000-4-5 pref. criteria A EN61000-4-6 pref. criteria A EN61000-4-8 pref. criteria A >1 Mhrs -40°C to +85°C (with derating) 110°C -55 °C to +125 °C +100 °C 95% rel. Humidity Free-air convection 10°C/W MIL-STD-810D 10...55Hz, 10G, 30Min. X,Y,Z 50.8 x 40.6 x 10.2 mm 48 g Nickel-coated copper Epoxy ( UL94-V0) 260°C, 10s, 1.5mm from case Open input or 2.5V…5.5V Short to –Vin or 0V…0.8V Dimensions Pin connections Pin 1 2 3 4 5 6 7 Single + Input - Input CTRL No Pin + Output - Output Trim Dual + Input - Input CTRL + Output Common - Output Trim Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 2/09 f Page 2 of 2 Deutschland: Inselkammerstrasse 10 D-82008 Unterhaching Tel.: 089 614 503-10 Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] E-Mail: [email protected]