60W DC-DC Converter P60A-Series ● ● ● ● ● ● ● Offer single, dual and triple output 50 to 60 W Output power 2:1 Wide input voltage range International safety standard approval Six-Sided continuous shield High efficiency up to 86% Short circuit protection Model selection guide Typ Single output P60A12S05P P60A12S12P P60A12S15P P60A12S24P P60A24S05P P60A24S12P P60A24S15P P60A24S24P P60A48S05P P60A48S12P P60A48S15P P60A48S24P Dual output P60A12D05P P60A12D12P P60A12D15P P60A12D512P P60A24D05P P60A24D12P P60A24D15P P60A24D512P P60A48D05P P60A48D12P P60A48D15P P60A48D512P Triple output P60A12T512P P60A24T512P P60A48T512P Input nominal voltage current no load Output 1 voltage [VDC] [mA] 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-72 36-72 36-72 36-72 20 20 20 20 15 15 15 15 10 10 10 10 5.0 12.0 15.0 24.0 5.0 12.0 15.0 24.0 5.0 12.0 15.0 24.0 12.0 5.0 4.0 2.5 12.0 5.0 4.0 2.5 12.0 5.0 4.0 2.5 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-72 36-72 36-72 36-72 20 20 20 20 15 15 15 15 10 10 10 10 5.0 12.0 15.0 5.0 5.0 12.0 15.0 5.0 5.0 12.0 15.0 5.0 5.0 2.5 2.0 5.0 5.0 2.5 2.0 12.0 5.0 2.5 2.0 12.0 9-18 18-36 36-72 20 15 10 5.0 5.0 5.0 5.0 5.0 5.0 [VDC] current Output 2 (or Dual Output) voltage current [A] [VDC] [A] 5.0 12.0 15.0 12.0 5.0 12.0 15.0 12.0 5.0 12.0 15.0 12.0 ± 12.0 ± 12.0 ± 12.0 Efficiency typ. Output Power [%] [W] 79 82 82 84 80 84 84 85 83 85 85 86 60 60 60 60 60 60 60 60 60 60 60 60 5.0 2.5 2.0 2.5 5.0 2.5 2.0 2.5 5.0 2.5 2.0 2.5 78 80 80 79 80 82 82 80 80 84 84 81 50 60 60 55 50 60 60 60 50 60 60 60 ± 1.25 ± 1.25 ± 1.25 78 79 80 55 55 55 Suffix "P" PCB mounting type, heat sink will be added on module. Suffix "T" Chassis mounting type, (terminal block) heat sink or fan force cooling. Indicate suffix when order! Page 1 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstraße 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 60W DC-DC Converter P60A-Series Specifications Input Voltage range Filter Input reversed protection Output Output Power Voltage accuracy (full load and nominal Vin) Voltage adjustability Ripple and noise (at 20 MHz BW) Short circuit Line voltage regulation (Iout nom, Vin min… Vin max) Load voltage regulation (Iout min…Iout nom) Transient recovery time @ 25% load, step changed Temperature coefficient Minimum load 9-18 VDC 18-36 VDC 36-72 VDC Pi-type Shunt diode built in, external fuse recommended ! 60 W max. ±1% ±10% ± 1% of Vout Coninuous ±1% Single output model: ± 2% Dual output model: ±2% Triple output model: ±5% 500 µs ± 0.02% / °C, max Single: and Dual: 0% +5V of triple output 0% ±12V of triple output 20% General Efficiency Switching frequency Environmental Operating temperature ambient Operating temperature case Storage temperature range Cooling MTBF according to MIL-HDBK-217F, GF40 Physical Dimensions “P” model Dimensions “T” model Weight Case material Isolation Rated voltage Resistance Remote control Remote control on Remote control off Shutdown idle current See table 80 kHz, typ. -25°C to +95°C (with derating, see diagram) +95 °C, max. -25 °C to +100 °C Free air convection 122,500 hrs 3.5 x 5.5 x 1.4 inches 88.9 x 139.7 x 35.6 mm 3.5 x 5.5 x 1.29 inches 88.9 x 139.7 x 32.9 mm “P” Model 690 g “T” Model 570 g metal 1500 VDC, min 9 10 Ω, min. Open or > + 5.5 VDC Short or 0V … < + 1.8 VDC referenced to – Input, pin 2 10mA Derating Page 2 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstraße 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 60W DC-DC Converter P60A-Series Internal circuit schematic Page 3 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstraße 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 60W DC-DC Converter P60A-Series Pin connections Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Single Omitted - Input - Input + Input + Input Remote CTRL NC - Output - Output + Output + Output - Sense / Trim up TRIM + Sense/ trim down Trimming Dual Omitted - Input - Input + Input + Input Remote CTRL NC - Sense / Trim up - Output + Output + Sense/ trim down - Output 2 TRIM + Output 2 Triple Omitted - Input - Input + Input + Input Remote CTRL NC - Sense / Trim up - Output + Output + Sense/ trim down - Output 2 Common –Vo 2 & +Vo 3 + Output 3 12 TRIM UP 13 TRIM DOWN 14 Dimensions Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 11 / 2004 f Page 4 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstraße 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]