M1-3R2VI-DU (Ver. 1.0) www.opticis.com DATA SHEET Optical Dual Link DVI Module M1-3R2VI-DU Contents ♦ Description ♦ Features ♦ Applications ♦ Technical Specifications ♦ Functions ♦ Drawing of Modules ♦ Drawing of Cable Connections ♦ DVI Pin Description ♦ Pin Description of DDC Connector ♦ Reliability Test Headquarter Opticis North America, Inc. Opticis Co., Ltd. # 501, ByucksanTechnopia, 434-6 Sangdaewon-Dong, Chungwon-Ku Sungnam City, Kyungki-Do, 463-120 South Korea Tel: +82 (31) 737-8033~9 Fax: +82 (31) 737-8079 330 Richmond Street, Suite 100, Chatham, Ontario CANADA N7M 1P7 Tel : (519) 355-0819 Fax : (519) 355-0520 Email : [email protected] www.opticis.com Copyright © 2008, All rights reserved by Opticis 09, June , 2008 -1- M1-3R2VI-DU (Ver. 1.0) www.opticis.com Optical DVI Dual Link Extension Module - Fiber Detachable Connection System of DVI Dual Link Description The M1-3R2VI-DU DVI Module is a new member of the Opticis family of products that stretches your DVI connectivity. It offers a fiber-optic long-distance extension of dual link DVI connectors. DDC connection is implemented over a CAT5e cable with RJ-45C. The reality of high-speed digital graphic interconnections mandates products to maintain video quality and cost effectiveness of integrated display systems. Optical technology for gigabit digital transmission makes it simple to extend digital graphic data above the extension limits of copper wires providing pure signal integrity for an ideal visual experience, no EMI/RFI emissions, light weight, rugged cabling and connectors, low power consumption and installation ease. The extension system consists of transmitter and receiver module boxes with female dual link DVI-D plugs, being able to connect PCs (Media Receiver) and displays (Monitor or HDTV) by dual link DVI-D copper cables respectively. Two (2) duplex LC patch cord fiber cables enable to transmit graphic data, 7 channels including a clock. The module also provides self-EDID programming feature that makes pure optical interconnection realized. It makes installation of M1-3R2VI-DU much easier and more flexible at any displays of various resolution types. The module extends DVI dual link data of WQXGA (2,560x1,600) resolution up to 2km (6, 600 feet) with virtual DDC. The shipping group is shown as follows; 1) 1ea x DVI Dual link Transmitter Module 2) 1ea x DVI Dual link Receiver Module 3) 2ea x DVI Dual link Copper Cable (1.8m) 4) 1ea x 24V Power Supply Adapter (AC 85-264V, 50/60Hz) 5) 1ea x AC Cord (US Type or EU type) 6) 1ea x User Manual 7) Option : 2 duplex LC Patch Cord Cable, CAT5e Cable, One more +24V Power Adapter for virtual DDC Copyright © 2008, All rights reserved by Opticis 09, June , 2008 -2- M1-3R2VI-DU (Ver. 1.0) www.opticis.com Features ♦ Supports up to 2,560x1,600 resolution at 60Hz refresh rate. ♦ Extends up to 100 m (328 feet) with DDC2B. 2 km (6,600 feet) with virtual DDC. ♦ Fiber-optic cables with four (4) LC or two (2) duplex LC fiber connectors are required to transmit Red, Green, and Blue, three (3) channels for each link and one clock. ♦ Offers DVI single link DVI connection through two (2) LC or one (1) duplex LC LC fibers. ♦ Provides self-EDID programming feature, detecting from a display and restoring to an EEPROM in the transmitter just by plugging to the display without any physical DDC connection. ♦ Applicable to both single and multi-mode fiber. ♦ Light weight detachable cables with secure connectors for fiber and copper. ♦ No software to install - plug & play simplicity. ♦ Low EMI/RFI emissions and inherent fiber data security. ♦ Complies with FDA/CDRH and IEC 60825-1 Class 1 Laser Eye Safety. ♦ Adopts only an external power supply, +24V to supply both modules over CAT5e cable. ♦ Uses 1310/1550nm single-mode light sources and equivalent photo detectors. Applications ♦ Power Mac G5 with graphic cards supporting Dual Link DVI and 30” Cinema Display ♦ Medical, military, aerospace, factory, and traffic control integrated digital display systems ♦ Digital TFT-LCD and plasma flat panel displays and projectors for conference room, auditorium, airports, stadium and kiosk systems. ♦ Digital Home Theatre Systems Copyright © 2008, All rights reserved by Opticis 09, June , 2008 -3- M1-3R2VI-DU (Ver. 1.0) www.opticis.com Technical Specifications - General Specifications Components Electrical Optical Mechanical Connect Parameter Laser Diodes in Tx Module Photo Diodes in Rx Module Input and Output Signals Data Transfer Rate (Graphic Data) Total Jitter at the end of Rx output Skew inter-channels Link Power Budget Module dimension (mm) Optical Connector Electric Connector Type from Modules and to Displays Specifications 1310nm/1550nm BIDI Transmitter with FP-LD 1310nm/1550nm BIDI receiver with GaAs PIN-PD TMDS Level (complying with DVI1.0) Max. 1.62Gbps Max. 309 ps Max. 6ns Min 10.5dB 111.8WX31HX215.9L 2 Duplex LC connectors 24 pin DVI-D plug 62.5/125 or 50/125 um Multi-mode Glass Fiber 9/125um Single-mode Glass Fiber Recommended Fiber Note*: some plastic couplers to clamp two LC connectors could not fit in. - Absolute Maximum Ratings Parameter Storage Temperature Supply Voltage Transmitter Differential Input Voltage Relative Humidity Lead Soldering Temperature & Time Symbol Tstg VCC Vd RH - Minimum - 10 10 5 - Maximum + 85 16 1 85 Units °C V V % 260°C, 10 sec Note*: Under the condition of No drops of dew - Recommended Operating Conditions Parameter Ambient Operating Temperature Data Output Load Power Supply Rejection (Note1) Supply Voltage Symbol TA RLD PSR VCC Minimum 0 + 22 Typical 50 50 + 24 Maximum 50 + 26 Units °C Ω mVp-p V Note1. Tested with a 50mVp-p sinusoidal signal in the frequency range from 500 Hz to 500 MHz on the VCC supply with the recommended power supply filter in place. Typically less than a 0.25 dB change in sensitivity is experienced. - Electrical Power Supply Characteristics (TA = 0 °C to +50 °C, unless otherwise noted) Parameter Supply Voltage Supply Current Power Dissipation TX RX TX RX Symbol VCC ITCC IRCC PTX PRX Minimum 22 180 270 3.8 5.8 Copyright © 2008, All rights reserved by Opticis Typical 24 220 330 5.3 7.9 Maximum 26 270 380 7.2 10.0 Units V mA mA W W 09, June , 2008 -4- M1-3R2VI-DU (Ver. 1.0) www.opticis.com - Optical & Electrical Characteristics Parameters Data Bit Rate Symbol 1310 Tx 1550 Rx 1550 Tx 1310 Rx (Top = 25℃) Condition Unit Min. PRBS 27-1,NRZ Mbps PRBS 27-1,NRZ Mbps Typ. Max. 1250 155.52 155.52 1250 1650 Remark 1650 -10 10 BER, 155Mbps /1.25Gbps Fiber Length 9µm core SMF km 2 TRANSMITTER Average Launched Power Extinction Ratio Center Wavelength POUT If=IBIAS + Imod/2 dBm -10 dB 5 CW, @ POUT nm 1260 1480 RMS Width nm 1360 1580 2.1 dB/Hz -120 ER C Spectral Width RIN Data Input Differential Voltage VIN Optical Rise/Fall Time tr/tf mV 20 – 80% 0 1310 1550 200 @1.31 um @1.55 µm 1600 0.26 2.0 nsec RECEIVER Maximum Input Power Pin dBm Sensitivity Ps dBm 1310 1550 Receiver Overload Signal Detect Threshold Decreasing light input Increasing light input LOS Hysteresis nm PIN,MAX dBm PD PA dBm dBm dB Wavelength - 0 -17 1260 1500 -3.0 1310 1550 155M Rx 1.65G Rx 1360 1600 PIN,MIN-3 PIN,MIN-2 1 TMDS Characteristics Transmitter TMDS Receiver TMDS Parameter Data Output Load Graphic Supply Voltage (Note2) Single-Ended High Level Input Voltage Single-Ended Low Level Input Voltage Single-Ended Input Swing Voltage Data Input Load Graphic Supply Voltage (Note3) Single-Ended Output Swing Voltage (Note4) Symbol RLD Minimum Typical 50 Maximum Units Ω GVCC + 3.1 + 3.3 + 3.5 V GVIH GVCC - 0.01 GVCC GVCC + 0.01 V GVIL GVCC - 0.6 - GVCC - 0.4 V 0.4 - 0.6 V GVISWING RLD Ω 50 GVCC GVISWING + 3.1 + 3.3 + 3.5 V 0.4 - 0.6 V Note2. Graphic Supply Voltage is regulated reference voltage for signal processing in modules Note3. Graphic Supply Voltage is regulated reference voltage for signal processing in modules Note4. TMDS outputs are coupled in AC Copyright © 2008, All rights reserved by Opticis 09, June , 2008 -5- M1-3R2VI-DU (Ver. 1.0) www.opticis.com Functions - Self-EDID Function The EDID in a display can be read and restored by just plugging it to the display. This selfEDID programming feature makes the installation of M1-3R2VI-DU more easy and flexible at any variable resolution display systems. - Power Save Mode in Transmitter Module The laser diodes work only when +5V voltage should be supplied into the 14-pin in DVI connectors, that is, detecting plugging the DVI plug to the PC. The voltage passing through a regulator from the +5V PC power or external power has LD drive circuit work. - Signal Detect Mode in Receiver Module It offers squelch function blocking output signals when optical input power is lower than as specified in a certain case, that is, detecting loosing the LC fiber-optic patch cord. Drawing of Modules Dimension [mm] Note: The transmitter, M1-3R2VI-DU-T and the receiver, M1-3R2VI-DU-R have the same mechanical dimensions. Copyright © 2008, All rights reserved by Opticis 09, June , 2008 -6- M1-3R2VI-DU (Ver. 1.0) www.opticis.com Drawing of Cable Connections Pin Description for DDC Connector 1 2 3 4 5 6 7 8 Pin 1 2 3 4 5 6 7 8 Symbol DDC Data GND DDC Data DDC Clock GND Power GND Power DDC Clock Power GND Power GND Copyright © 2008, All rights reserved by Opticis Functional Description DDC Data line return ground DDC Data line for DDC2B communication DDC Clock line return ground Main power return ground Main power for Opticis module DDC Clock line for DDC2B communication Main power return ground Main power return ground 09, June , 2008 -7- M1-3R2VI-DU (Ver. 1.0) www.opticis.com DVI Pin Description Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 Symbol CH2CH2+ GND CH4CH4+ DDC Clock DDC Data N.C. CH1CH1+ GND CH3CH3+ 14 5V 15 GND Hot plug Detect CH0CH0+ GND CH5CH5+ GND CLKCLK+ 16 17 18 19 20 21 22 23 24 Functional Description TMDS Data Signal Channel 2 Negative TMDS Data Signal Channel 2 Positive TMDS Data Signal Channel 2/4 Shield TMDS Data Signal Channel 4 Negative TMDS Data Signal Channel 4 Positive DDC Clock line for DDC2B communication DDC Data line for DDC2B communication TMDS Data Signal Channel 1 Negative TMDS Data Signal Channel 1 Positive TMDS Data Signal Channel 1/3 Shield TMDS Data Signal Channel 3 Negative TMDS Data Signal Channel 3 Positive 5 V Input for Transmitter from Host 5 V Output for Monitor from Receiver Ground Signal is driven by monitor to enable the system to identify the presence of a monitor TMDS Data Signal Channel 0 Negative TMDS Data Signal Channel 0 Positive TMDS Data Signal Channel 0/5 Shield TMDS Data Signal Channel 5 Negative TMDS Data Signal Channel 5 Positive TMDS Clock Signal Shield TMDS Clock Channel Negative TMDS Clock Channel Positive Copyright © 2008, All rights reserved by Opticis 09, June , 2008 -8- M1-3R2VI-DU (Ver. 1.0) www.opticis.com Reliability Test We have three kinds of test criteria for a reduction of variability and a continuous improvement of the process by our FMEA (Failure Mode and Effective Analysis) program. 1) Mechanical test (Vibration, Shock) 2) Temp. & Humidity test 3) EMC test (FCC class A and CE Verification for M1-3R2VI-DU ) Mechanical and Temp. & Humidity Test Duration Sample Size 30 Min (Each Temperature) n=3 TS = -30℃ 96 HR n=3 High Temperature TS = 60℃ 96 HR n=3 High Humidity / High Temperature TS: 60℃ RH: 85% 96 HR n=3 Mechanical Shock Pulse: 11 ms Peak level: 30 g Shock pulse: 6times/Axis - n=3 Peak acceleration: 5 g Frequency: 10~55 ㎐ Sweep time: 5 Minutes 2 Times/Axis - n=3 Heading Test Operating Test Operating at each Temperature (See Note) -10~50℃ (Interval: 10℃) Low Temperature Storage Test Mechanical Test Mechanical Vibration Conditions Copyright © 2008, All rights reserved by Opticis Remarks Note: Evaluate display quality of Laser Beam Projector connected to Graphic Signal Generator (Quantum Data: GD-802B) at each temperature. 1. TS: Storage Temperature 2. RH: Relative Humidity 09, June , 2008 -9- M1-3R2VI-DU (Ver. 1.0) www.opticis.com EMC Test 1) EMI: Meet FCC class A (ICES-003) and CE class A STANDARDS EN 55 022 (CISPR22) CE (Conducted Emission) & FCC; PART 15 SUBPART B RE (Radiated Emission) EN 61000-3-2 (IEC 61000-3-2) Harmonics EN 61000-3-3 (IEC 61000-3-3) Flickers CONDITIONS Meet Class A Meet Class A Meet Class A 2) EMS: Meet CE standards (EN 55024) and CISPR24 equivalents EN 61 000-4-2:1995 EN 61 000-4-3:1996 EN 61 000-4-4:1995 EN 61 000-4-5:1995 EN 61 000-4-6:1996 EN 61 000-4-11:1994 STANDARDS Electrostatic Discharge Immunity (Air: 8kv, Contact: 4kv) Radiated RF E-Field (80~1000 MHz) 3V/m (AM 80%, 1kHz) Fast Transients (5kHz, 60Seconds) Surge Transients Conducted Susceptibility (CS) Radiated Susceptibility (RS) Voltage Dips, Interruption & Variation Copyright © 2008, All rights reserved by Opticis CONDITIONS Meet Criterion A or B Meet Criterion A or B Meet Criterion A or B Meet Criterion A or B Meet Criterion A or B Meet Criterion A or B, and C 09, June , 2008 - 10 -