Download

M1-3R2VI-DU (Ver. 1.0)
www.opticis.com
DATA SHEET
Optical Dual Link DVI Module
M1-3R2VI-DU
Contents
♦ Description
♦ Features
♦ Applications
♦ Technical Specifications
♦ Functions
♦ Drawing of Modules
♦ Drawing of Cable Connections
♦ DVI Pin Description
♦ Pin Description of DDC Connector
♦ Reliability Test
Headquarter
Opticis North America, Inc.
Opticis Co., Ltd.
# 501, ByucksanTechnopia,
434-6 Sangdaewon-Dong, Chungwon-Ku
Sungnam City, Kyungki-Do, 463-120
South Korea
Tel: +82 (31) 737-8033~9
Fax: +82 (31) 737-8079
330 Richmond Street, Suite 100,
Chatham, Ontario
CANADA N7M 1P7
Tel : (519) 355-0819
Fax : (519) 355-0520
Email : [email protected]
www.opticis.com
Copyright © 2008, All rights reserved by Opticis
09, June , 2008
-1-
M1-3R2VI-DU (Ver. 1.0)
www.opticis.com
Optical DVI Dual Link Extension Module
- Fiber Detachable Connection System of DVI Dual Link Description
The M1-3R2VI-DU DVI Module is a new member of the Opticis family of products that
stretches your DVI connectivity. It offers a fiber-optic long-distance extension of dual link DVI
connectors. DDC connection is implemented over a CAT5e cable with RJ-45C.
The reality of high-speed digital graphic interconnections mandates products to maintain video
quality and cost effectiveness of integrated display systems. Optical technology for gigabit digital
transmission makes it simple to extend digital graphic data above the extension limits of copper
wires providing pure signal integrity for an ideal visual experience, no EMI/RFI emissions, light
weight, rugged cabling and connectors, low power consumption and installation ease.
The extension system consists of transmitter and receiver module boxes with female dual link
DVI-D plugs, being able to connect PCs (Media Receiver) and displays (Monitor or HDTV) by
dual link DVI-D copper cables respectively. Two (2) duplex LC patch cord fiber cables enable to
transmit graphic data, 7 channels including a clock.
The module also provides self-EDID programming feature that makes pure optical
interconnection realized. It makes installation of M1-3R2VI-DU much easier and more flexible at
any displays of various resolution types. The module extends DVI dual link data of WQXGA
(2,560x1,600) resolution up to 2km (6, 600 feet) with virtual DDC.
The shipping group is shown as follows;
1) 1ea x DVI Dual link Transmitter Module
2) 1ea x DVI Dual link Receiver Module
3) 2ea x DVI Dual link Copper Cable (1.8m)
4) 1ea x 24V Power Supply Adapter (AC 85-264V, 50/60Hz)
5) 1ea x AC Cord (US Type or EU type)
6) 1ea x User Manual
7) Option : 2 duplex LC Patch Cord Cable, CAT5e Cable, One more +24V Power Adapter
for virtual DDC
Copyright © 2008, All rights reserved by Opticis
09, June , 2008
-2-
M1-3R2VI-DU (Ver. 1.0)
www.opticis.com
Features
♦
Supports up to 2,560x1,600 resolution at 60Hz refresh rate.
♦
Extends up to 100 m (328 feet) with DDC2B.
2 km (6,600 feet) with virtual DDC.
♦
Fiber-optic cables with four (4) LC or two (2) duplex LC fiber connectors are required to
transmit Red, Green, and Blue, three (3) channels for each link and one clock.
♦
Offers DVI single link DVI connection through two (2) LC or one (1) duplex LC LC fibers.
♦
Provides self-EDID programming feature, detecting from a display and restoring to an
EEPROM in the transmitter just by plugging to the display without any physical DDC
connection.
♦ Applicable to both single and multi-mode fiber.
♦
Light weight detachable cables with secure connectors for fiber and copper.
♦
No software to install - plug & play simplicity.
♦ Low EMI/RFI emissions and inherent fiber data security.
♦
Complies with FDA/CDRH and IEC 60825-1 Class 1 Laser Eye Safety.
♦
Adopts only an external power supply, +24V to supply both modules over CAT5e cable.
♦
Uses 1310/1550nm single-mode light sources and equivalent photo detectors.
Applications
♦
Power Mac G5 with graphic cards supporting Dual Link DVI and 30” Cinema Display
♦
Medical, military, aerospace, factory, and traffic control integrated digital display systems
♦
Digital TFT-LCD and plasma flat panel displays and projectors for conference room,
auditorium, airports, stadium and kiosk systems.
♦
Digital Home Theatre Systems
Copyright © 2008, All rights reserved by Opticis
09, June , 2008
-3-
M1-3R2VI-DU (Ver. 1.0)
www.opticis.com
Technical Specifications
-
General Specifications
Components
Electrical
Optical
Mechanical
Connect
Parameter
Laser Diodes in Tx Module
Photo Diodes in Rx Module
Input and Output Signals
Data Transfer Rate (Graphic Data)
Total Jitter at the end of Rx output
Skew inter-channels
Link Power Budget
Module dimension (mm)
Optical Connector
Electric Connector Type from Modules
and to Displays
Specifications
1310nm/1550nm BIDI Transmitter with FP-LD
1310nm/1550nm BIDI receiver with GaAs PIN-PD
TMDS Level (complying with DVI1.0)
Max. 1.62Gbps
Max. 309 ps
Max. 6ns
Min 10.5dB
111.8WX31HX215.9L
2 Duplex LC connectors
24 pin DVI-D plug
62.5/125 or 50/125 um Multi-mode Glass Fiber
9/125um Single-mode Glass Fiber
Recommended Fiber
Note*: some plastic couplers to clamp two LC connectors could not fit in.
-
Absolute Maximum Ratings
Parameter
Storage Temperature
Supply Voltage
Transmitter Differential Input Voltage
Relative Humidity
Lead Soldering Temperature & Time
Symbol
Tstg
VCC
Vd
RH
-
Minimum
- 10
10
5
-
Maximum
+ 85
16
1
85
Units
°C
V
V
%
260°C, 10 sec
Note*: Under the condition of No drops of dew
-
Recommended Operating Conditions
Parameter
Ambient Operating Temperature
Data Output Load
Power Supply Rejection (Note1)
Supply Voltage
Symbol
TA
RLD
PSR
VCC
Minimum
0
+ 22
Typical
50
50
+ 24
Maximum
50
+ 26
Units
°C
Ω
mVp-p
V
Note1. Tested with a 50mVp-p sinusoidal signal in the frequency range from 500 Hz to 500 MHz on the VCC supply with
the recommended power supply filter in place. Typically less than a 0.25 dB change in sensitivity is experienced.
-
Electrical Power Supply Characteristics
(TA = 0 °C to +50 °C, unless otherwise noted)
Parameter
Supply Voltage
Supply Current
Power Dissipation
TX
RX
TX
RX
Symbol
VCC
ITCC
IRCC
PTX
PRX
Minimum
22
180
270
3.8
5.8
Copyright © 2008, All rights reserved by Opticis
Typical
24
220
330
5.3
7.9
Maximum
26
270
380
7.2
10.0
Units
V
mA
mA
W
W
09, June , 2008
-4-
M1-3R2VI-DU (Ver. 1.0)
www.opticis.com
-
Optical & Electrical Characteristics
Parameters
Data Bit
Rate
Symbol
1310 Tx
1550 Rx
1550 Tx
1310 Rx
(Top = 25℃)
Condition
Unit
Min.
PRBS 27-1,NRZ Mbps
PRBS 27-1,NRZ Mbps
Typ.
Max.
1250
155.52
155.52
1250
1650
Remark
1650
-10
10 BER,
155Mbps
/1.25Gbps
Fiber Length
9µm core SMF
km
2
TRANSMITTER
Average Launched
Power
Extinction Ratio
Center Wavelength
POUT
If=IBIAS + Imod/2
dBm
-10
dB
5
CW, @ POUT
nm
1260
1480
RMS Width
nm
1360
1580
2.1
dB/Hz
-120
ER
C
Spectral Width
RIN
Data Input Differential
Voltage
VIN
Optical Rise/Fall Time
tr/tf
mV
20 – 80%
0
1310
1550
200
@1.31 um
@1.55 µm
1600
0.26
2.0
nsec
RECEIVER
Maximum Input Power
Pin
dBm
Sensitivity
Ps
dBm
1310
1550
Receiver Overload
Signal Detect Threshold
Decreasing light input
Increasing light input
LOS Hysteresis
nm
PIN,MAX
dBm
PD
PA
dBm
dBm
dB
Wavelength
-
0
-17
1260
1500
-3.0
1310
1550
155M Rx
1.65G Rx
1360
1600
PIN,MIN-3
PIN,MIN-2
1
TMDS Characteristics
Transmitter
TMDS
Receiver
TMDS
Parameter
Data Output Load
Graphic Supply Voltage
(Note2)
Single-Ended High Level
Input Voltage
Single-Ended Low Level
Input Voltage
Single-Ended Input Swing
Voltage
Data Input Load
Graphic Supply Voltage
(Note3)
Single-Ended Output Swing
Voltage (Note4)
Symbol
RLD
Minimum
Typical
50
Maximum
Units
Ω
GVCC
+ 3.1
+ 3.3
+ 3.5
V
GVIH
GVCC - 0.01
GVCC
GVCC + 0.01
V
GVIL
GVCC - 0.6
-
GVCC - 0.4
V
0.4
-
0.6
V
GVISWING
RLD
Ω
50
GVCC
GVISWING
+ 3.1
+ 3.3
+ 3.5
V
0.4
-
0.6
V
Note2. Graphic Supply Voltage is regulated reference voltage for signal processing in modules
Note3. Graphic Supply Voltage is regulated reference voltage for signal processing in modules
Note4. TMDS outputs are coupled in AC
Copyright © 2008, All rights reserved by Opticis
09, June , 2008
-5-
M1-3R2VI-DU (Ver. 1.0)
www.opticis.com
Functions
-
Self-EDID Function
The EDID in a display can be read and restored by just plugging it to the display. This selfEDID programming feature makes the installation of M1-3R2VI-DU more easy and flexible at
any variable resolution display systems.
-
Power Save Mode in Transmitter Module
The laser diodes work only when +5V voltage should be supplied into the 14-pin in DVI
connectors, that is, detecting plugging the DVI plug to the PC. The voltage passing through a
regulator from the +5V PC power or external power has LD drive circuit work.
-
Signal Detect Mode in Receiver Module
It offers squelch function blocking output signals when optical input power is lower than as
specified in a certain case, that is, detecting loosing the LC fiber-optic patch cord.
Drawing of Modules
Dimension [mm]
Note: The transmitter, M1-3R2VI-DU-T and the receiver, M1-3R2VI-DU-R have the same
mechanical dimensions.
Copyright © 2008, All rights reserved by Opticis
09, June , 2008
-6-
M1-3R2VI-DU (Ver. 1.0)
www.opticis.com
Drawing of Cable Connections
Pin Description for DDC Connector
1 2 3 4 5 6 7 8
Pin
1
2
3
4
5
6
7
8
Symbol
DDC Data GND
DDC Data
DDC Clock GND
Power GND
Power
DDC Clock
Power GND
Power GND
Copyright © 2008, All rights reserved by Opticis
Functional Description
DDC Data line return ground
DDC Data line for DDC2B communication
DDC Clock line return ground
Main power return ground
Main power for Opticis module
DDC Clock line for DDC2B communication
Main power return ground
Main power return ground
09, June , 2008
-7-
M1-3R2VI-DU (Ver. 1.0)
www.opticis.com
DVI Pin Description
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
Symbol
CH2CH2+
GND
CH4CH4+
DDC Clock
DDC Data
N.C.
CH1CH1+
GND
CH3CH3+
14
5V
15
GND
Hot plug
Detect
CH0CH0+
GND
CH5CH5+
GND
CLKCLK+
16
17
18
19
20
21
22
23
24
Functional Description
TMDS Data Signal Channel 2 Negative
TMDS Data Signal Channel 2 Positive
TMDS Data Signal Channel 2/4 Shield
TMDS Data Signal Channel 4 Negative
TMDS Data Signal Channel 4 Positive
DDC Clock line for DDC2B communication
DDC Data line for DDC2B communication
TMDS Data Signal Channel 1 Negative
TMDS Data Signal Channel 1 Positive
TMDS Data Signal Channel 1/3 Shield
TMDS Data Signal Channel 3 Negative
TMDS Data Signal Channel 3 Positive
5 V Input for Transmitter from Host
5 V Output for Monitor from Receiver
Ground
Signal is driven by monitor to enable the system to identify the presence
of a monitor
TMDS Data Signal Channel 0 Negative
TMDS Data Signal Channel 0 Positive
TMDS Data Signal Channel 0/5 Shield
TMDS Data Signal Channel 5 Negative
TMDS Data Signal Channel 5 Positive
TMDS Clock Signal Shield
TMDS Clock Channel Negative
TMDS Clock Channel Positive
Copyright © 2008, All rights reserved by Opticis
09, June , 2008
-8-
M1-3R2VI-DU (Ver. 1.0)
www.opticis.com
Reliability Test
We have three kinds of test criteria for a reduction of variability and a continuous improvement of
the process by our FMEA (Failure Mode and Effective Analysis) program.
1) Mechanical test (Vibration, Shock)
2) Temp. & Humidity test
3) EMC test (FCC class A and CE Verification for M1-3R2VI-DU )
Mechanical and Temp. & Humidity Test
Duration
Sample
Size
30 Min
(Each Temperature)
n=3
TS = -30℃
96 HR
n=3
High Temperature
TS = 60℃
96 HR
n=3
High Humidity /
High Temperature
TS: 60℃
RH: 85%
96 HR
n=3
Mechanical Shock
Pulse: 11 ms
Peak level: 30 g
Shock pulse:
6times/Axis
-
n=3
Peak acceleration: 5 g
Frequency: 10~55 ㎐
Sweep time: 5 Minutes
2 Times/Axis
-
n=3
Heading
Test
Operating
Test
Operating at each
Temperature (See
Note)
-10~50℃ (Interval:
10℃)
Low Temperature
Storage
Test
Mechanical
Test
Mechanical
Vibration
Conditions
Copyright © 2008, All rights reserved by Opticis
Remarks
Note: Evaluate display
quality of Laser Beam
Projector connected to
Graphic Signal
Generator (Quantum
Data: GD-802B) at each
temperature.
1. TS: Storage
Temperature
2. RH: Relative Humidity
09, June , 2008
-9-
M1-3R2VI-DU (Ver. 1.0)
www.opticis.com
EMC Test
1) EMI: Meet FCC class A (ICES-003) and CE class A
STANDARDS
EN 55 022 (CISPR22)
CE (Conducted Emission) &
FCC; PART 15 SUBPART B
RE (Radiated Emission)
EN 61000-3-2 (IEC 61000-3-2)
Harmonics
EN 61000-3-3 (IEC 61000-3-3)
Flickers
CONDITIONS
Meet Class A
Meet Class A
Meet Class A
2) EMS: Meet CE standards (EN 55024) and CISPR24 equivalents
EN 61 000-4-2:1995
EN 61 000-4-3:1996
EN 61 000-4-4:1995
EN 61 000-4-5:1995
EN 61 000-4-6:1996
EN 61 000-4-11:1994
STANDARDS
Electrostatic Discharge Immunity
(Air: 8kv, Contact: 4kv)
Radiated RF E-Field (80~1000 MHz)
3V/m (AM 80%, 1kHz)
Fast Transients (5kHz, 60Seconds)
Surge Transients
Conducted Susceptibility (CS)
Radiated Susceptibility (RS)
Voltage Dips, Interruption & Variation
Copyright © 2008, All rights reserved by Opticis
CONDITIONS
Meet Criterion A or B
Meet Criterion A or B
Meet Criterion A or B
Meet Criterion A or B
Meet Criterion A or B
Meet Criterion A or B, and C
09, June , 2008
- 10 -