M1-1P0x (Ver. 1.2) www.opticis.com DATA SHEET Point-to-Point DVI Hybrid Cable M1-1P0E Contents Description Features Absolute Maximum Ratings Recommended Operating Conditions Electrical Power Supply Characteristics Receiver Electrical Interface Specifications of fiber-optic cables Drawing of transmitter and receiver modules DVI Pin Description Reliability Test of Modules Terminology Headquarter Opticis Co., Ltd. # 907, ByusanTechnopia, 434-6 Sangdaewon-Dong, Chungwon-Ku, Sungnam City, Kyungki-Do, 463-120 South Korea Tel: +82 (31) 737-8033~9 Fax: +82 (31) 707-8079 www.opticis.com Copyright © 2012, All rights reserved, Opticis Co., Ltd. Aug. 03, 2012 M1-1P0E (Ver. 1.2) www.opticis.com Point-to-Point DVI Hybrid Cable M1-1P0E Description The Digital Visual Interface is a low cost, high quality graphics interface between a host processor video card and a display panel. Optical technology for this transmission stretches the performance beyond the limitations of copper wire with longer length, data security, negligible RFI/EMI and the elimination of costly analog distribution systems. Point-to-Point DVI hybrid cable, M1-1P0E has four (4) multi-mode fibers for TMDS transmission and copper wires for DDC/HDCP in a jacket. It transmits uncompressed WUXGA (1920x1200) 60Hz, 1080p up to 100m (328feet) and supplies +5V DC power either from video sources or external power adapter in the shipping group. There are male DVI-D connectors at each end. The high-speed graphic data transmission is accomplished by using a VCSEL array inside the transmitter connector, and a Pin-PD array inside the receiver connector. Shipping Group * M1-1P0E Optical DVI Cable: One (1) unit * +5V AC/DC power adapter: One (1) unit * User’s Manual Copyright © 2012, All rights reserved, Opticis Co., Ltd. -1- Aug. 03, 2012 M1-1P0E (Ver. 1.2) www.opticis.com Feature Checklist • Compact design of end connector allows direct connection to the host video card and display • Hybrid cable with four (4) multi-mode fibers for TMDS transmission and copper wires for DDC/HDCP • Extends WUXGA (1920x1200), 60Hz and 1080p up to 100m (328feet) • Uses +5V DC power from video sources or +5V DV power adapter in the shipping group • Auto-power switching • Supports bit rate up to 1.65Gbps/ch • Operating temperature: 0 ~ 50℃ • Storage temperature: -30 ~ 70℃ • Input power: +5V 1A • Size (WDH): 39 x 53 x 15.4mm • FCC/CE standards for EMI/RFI emmision Applications Digital TFT-LCD FPDs, PDPs and projectors for medical imaging, air traffic control, factory automation, conference rooms, auditorium A/V systems, etc. Kiosks with digital FPDs showing full motion graphic displays from remote systems PDP displays for information display in public sites. LED signboards in streets and stadiums. Home Theatre applications Options Custom lengths up to 100m are also available from the factory. Copyright © 2012, All rights reserved, Opticis Co., Ltd. -2- Aug. 03, 2012 M1-1P0E (Ver. 1.2) www.opticis.com Absolute Maximum Ratings Parameter Storage Temperature Supply Voltage Transmitter Differential Input Voltage Relative Humidity Lead Soldering Temperature & Time Symbol Tstg VCC Vd RH - Minimum - 30 - 0.3 0 - Maximum + 70 + 6.0 1 85 Units C V V % 260C, 10 sec Recommended Operating Conditions Parameter Ambient Operating Temperature Data Output Load Power Supply Rejection (Note1) Supply Voltage Graphic Supply Voltage (Note2) Symbol TA RLD PSR VCC GVCC Minimum 0 + 4.5 + 3.0 Typical 50 50 + 5.0 + 3.3 Maximum + 50 + 5.5 + 3.6 Units C Ω mVp-p V V Note1. Tested with a 50mVp-p sinusoidal signal in the frequency range from 500 Hz to 500 MHz on the V CC supply with the recommended power supply filter in place. Typically less than a 0.25 dB change in sensitivity is experienced. Note2. Graphic Supply Voltage is only for the Graphic Signal Interface which is generated by regulator in the Transmitter and Receiver Electrical Power Supply Characteristics 1. For M1-1P0E with the external power adaptor, the characteristics are as follows; Parameter Supply Voltage Supply Current Power Dissipation TX RX TX RX Symbol VCC ITCC IRCC PTX PRX Minimum 4.5 - Copyright © 2012, All rights reserved, Opticis Co., Ltd. -3- Typical 5 170 130 0.85 0.65 Maximum 5.5 200 150 1.1 0.825 Units V mA mA W W Aug. 03, 2012 M1-1P0E (Ver. 1.2) www.opticis.com Specifications of Fibre-Optic Cables Parameter Core Diameter Buffer Diameter Proof Test Level Value 200um (HPCF), 62.5um (MMGOF) 0.5mm (HPCF), 0.25mm (MMGOF) 0.53GPa Parameter Cladding Diameter (only for HPCF) Outside Diameter Value 225um 7.6mm Drawing of transmitter and receiver modules Dimension [mm] Copyright © 2012, All rights reserved, Opticis Co., Ltd. -4- Aug. 03, 2012 M1-1P0E (Ver. 1.2) www.opticis.com DVI Pin Description Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 Symbol CH2CH2+ GND Functional Description TMDS Data Signal Channel 2 Negative TMDS Data Signal Channel 2 Positive TMDS Data Signal Channel 2 Shield DDC Clock DDC Data N.C. CH1CH1+ GND DDC Clock line for DDC2B communication DDC Data line for DDC2B communication 14 5V 15 GND Hot plug Detect CH0CH0+ GND 5 V Input for Transmitter from Host 5 V Output for Monitor from Receiver Ground Signal is driven by monitor to enable the system to identify the presence of a monitor TMDS Data Signal Channel 0 Negative TMDS Data Signal Channel 0 Positive TMDS Data Signal Channel 0 Shield GND CLK+ CLK- TMDS Clock Signal Shield TMDS Clock Channel Positive TMDS Clock Channel Negative 16 17 18 19 20 21 22 23 24 TMDS Data Signal Channel 1 Negative TMDS Data Signal Channel 1 Positive TMDS Data Signal Channel 1 Shield Note: Channels 3, 4 and 5 dual-link data signal pins are not used Copyright © 2012, All rights reserved, Opticis Co., Ltd. -5- Aug. 03, 2012 M1-1P0E (Ver. 1.2) www.opticis.com Reliability Test Opticis utilizes three types of test criteria for a reduction of variability and a continuous improvement of the process by its FEMA (Failure Mode and Effective Analysis) program. 1) Mechanical test (vibration, shock) 2) Temperature & humidity tests 3) EMC test (FCC class A and CE Verification) Mechanical and Temperature & Humidity Test Data Heading Operating Test Storage Test Test Operating at each Temperature Conditions Duration Sample Failure Size 30 Min * - 0 ~ 50 °C (Each (Interval: 10 °C) n =4 0 Temperature) (See Note) Remarks Note: Visual Test the Display Low Temperature * TS = -30 °C 96 HR n=2 0 1. TS: Storage Temperature High Temperature * TS = 70 °C 96 HR n=2 0 2. RH: Relative Humidity High Humidity * TS: 85 °C High Temperature 96 HR n=2 0 * RH: 85% - n=2 0 - n=2 0 Mechanical Shock * Pulse: 11 ms * Peak level: 30 g * Shock pulse: 3 times/Axis Mechanical Test * Peak acceleration: 20 g Mechanical * Frequency: 20~2000 ㎐ Vibration * Sweep time: 30 Minutes * 4 Times/Axis Copyright © 2012, All rights reserved, Opticis Co., Ltd. -6- Aug. 03, 2012 on M1-1P0E (Ver. 1.2) www.opticis.com EMC Test Data 1) EMI: Meet FCC class A (ICES-003) and CE class A STANDARDS EN 55 022 (CISPR22) CE (Conducted Emission) & FCC; PART 15 SUBPART B RE (Radiated Emission) EN 61000-3-2 (IEC 61000-3-2) Harmonics EN 61000-3-3 (IEC 61000-3-3) Flickers CONDITIONS Meet Class A Meet Class A Meet Class A 2) EMS: Meet CE standards (EN 55024) and CISPR24 equivalents EN 61 000-4-2:1995 EN 61 000-4-3:1996 EN 61 000-4-4:1995 EN 61 000-4-5:1995 EN 61 000-4-6:1996 EN 61 000-4-11:1994 STANDARDS Electrostatic Discharge Immunity (Air: 8kv, Contact: 4kv) Radiated RF E-Field (80~1000 MHz) 3V/m (AM 80%, 1kHz) Fast Transients (5kHz, 60Seconds) Surge Transients Conducted Susceptibility (CS) Radiated Susceptibility (RS) Voltage Dips, Interruption & Variation CONDITIONS Meet Criterion B Meet Criterion A Meet Criterion B Meet Criterion B Meet Criterion A Meet Criterion C Terminology DDC DVI-D EDID EMI EMS HDCP PDP RFI TFT-LCD TMDS VCSEL VESA Digital Display Channel. Latest specification is DDC2B. Digital Visual Interface. Digital connection only – no analog. Extended Display Identification Data. EDID parameters are sent over the DDC link. Electro Magnetic Interference. Electro Magnetic Susceptibility. High Definition Content Protection. These parameters are part of the 2002 High Definition Multimedia Interface (HDMI) specification for Consumer Electronics. Plasma Display Panel. Large HDTV panels up to 63” use this display technology. Radio Frequency Interference. Thin Film Transistor Liquid Crystal Display – the technology of most computer display panels with VESA resolutions up to 1600x1200 pixels. Transmission Minimized Differential Signalling is the Silicon Image Inc. protocol for the digital signals. Vertical Cavity Surface Emitting Laser transmitter diode. The receiver diode is the PIN-Photo Diode. These components are designed and manufactured by Opticis. Video Electronics Standards Association. Copyright © 2012, All rights reserved, Opticis Co., Ltd. -7- Aug. 03, 2012