Download

M1-1P0x (Ver. 1.2)
www.opticis.com
DATA SHEET
Point-to-Point DVI Hybrid Cable
M1-1P0E
Contents
 Description
 Features
 Absolute Maximum Ratings
 Recommended Operating Conditions
 Electrical Power Supply Characteristics
 Receiver Electrical Interface
 Specifications of fiber-optic cables
 Drawing of transmitter and receiver modules
 DVI Pin Description
 Reliability Test of Modules
 Terminology
Headquarter
Opticis Co., Ltd.
# 907, ByusanTechnopia, 434-6
Sangdaewon-Dong, Chungwon-Ku,
Sungnam City, Kyungki-Do, 463-120
South Korea
Tel: +82 (31) 737-8033~9
Fax: +82 (31) 707-8079
www.opticis.com
Copyright © 2012, All rights reserved, Opticis Co., Ltd.
Aug. 03, 2012
M1-1P0E (Ver. 1.2)
www.opticis.com
Point-to-Point DVI Hybrid Cable
M1-1P0E
Description
The Digital Visual Interface is a low cost, high quality graphics interface between a host processor
video card and a display panel. Optical technology for this transmission stretches the performance
beyond the limitations of copper wire with longer length, data security, negligible RFI/EMI and the
elimination of costly analog distribution systems.
Point-to-Point DVI hybrid cable, M1-1P0E has four (4) multi-mode fibers for TMDS transmission and
copper wires for DDC/HDCP in a jacket. It transmits uncompressed WUXGA (1920x1200) 60Hz,
1080p up to 100m (328feet) and supplies +5V DC power either from video sources or external power
adapter in the shipping group.
There are male DVI-D connectors at each end. The high-speed graphic data transmission is
accomplished by using a VCSEL array inside the transmitter connector, and a Pin-PD array inside the
receiver connector.
Shipping Group
* M1-1P0E Optical DVI Cable: One (1) unit
* +5V AC/DC power adapter: One (1) unit
* User’s Manual
Copyright © 2012, All rights reserved, Opticis Co., Ltd.
-1-
Aug. 03, 2012
M1-1P0E (Ver. 1.2)
www.opticis.com
Feature Checklist
• Compact design of end connector allows direct connection to the host video card and display
•
Hybrid cable with four (4) multi-mode fibers for TMDS
transmission and copper wires for DDC/HDCP
•
Extends WUXGA (1920x1200), 60Hz and 1080p up to 100m (328feet)
•
Uses +5V DC power from video sources or +5V DV power adapter in the shipping group
•
Auto-power switching
•
Supports bit rate up to 1.65Gbps/ch
•
Operating temperature: 0 ~ 50℃
•
Storage temperature: -30 ~ 70℃
•
Input power: +5V 1A
•
Size (WDH): 39 x 53 x 15.4mm
•
FCC/CE standards for EMI/RFI emmision
Applications

Digital TFT-LCD FPDs, PDPs and projectors for medical imaging, air traffic control, factory
automation, conference rooms, auditorium A/V systems, etc.

Kiosks with digital FPDs showing full motion graphic displays from remote systems

PDP displays for information display in public sites.

LED signboards in streets and stadiums.

Home Theatre applications
Options

Custom lengths up to 100m are also available from the factory.
Copyright © 2012, All rights reserved, Opticis Co., Ltd.
-2-
Aug. 03, 2012
M1-1P0E (Ver. 1.2)
www.opticis.com
Absolute Maximum Ratings
Parameter
Storage Temperature
Supply Voltage
Transmitter Differential Input Voltage
Relative Humidity
Lead Soldering Temperature & Time
Symbol
Tstg
VCC
Vd
RH
-
Minimum
- 30
- 0.3
0
-
Maximum
+ 70
+ 6.0
1
85
Units
C
V
V
%
260C, 10 sec
Recommended Operating Conditions
Parameter
Ambient Operating Temperature
Data Output Load
Power Supply Rejection (Note1)
Supply Voltage
Graphic Supply Voltage (Note2)
Symbol
TA
RLD
PSR
VCC
GVCC
Minimum
0
+ 4.5
+ 3.0
Typical
50
50
+ 5.0
+ 3.3
Maximum
+ 50
+ 5.5
+ 3.6
Units
C
Ω
mVp-p
V
V
Note1. Tested with a 50mVp-p sinusoidal signal in the frequency range from 500 Hz to 500 MHz on the V CC supply with
the recommended power supply filter in place. Typically less than a 0.25 dB change in sensitivity is experienced.
Note2. Graphic Supply Voltage is only for the Graphic Signal Interface which is generated by regulator in the Transmitter
and Receiver
Electrical Power Supply Characteristics
1.
For M1-1P0E with the external power adaptor, the characteristics are as follows;
Parameter
Supply Voltage
Supply Current
Power
Dissipation
TX
RX
TX
RX
Symbol
VCC
ITCC
IRCC
PTX
PRX
Minimum
4.5
-
Copyright © 2012, All rights reserved, Opticis Co., Ltd.
-3-
Typical
5
170
130
0.85
0.65
Maximum
5.5
200
150
1.1
0.825
Units
V
mA
mA
W
W
Aug. 03, 2012
M1-1P0E (Ver. 1.2)
www.opticis.com
Specifications of Fibre-Optic Cables
Parameter
Core Diameter
Buffer Diameter
Proof Test Level
Value
200um (HPCF),
62.5um (MMGOF)
0.5mm (HPCF),
0.25mm (MMGOF)
0.53GPa
Parameter
Cladding Diameter (only
for HPCF)
Outside Diameter
Value
225um
7.6mm
Drawing of transmitter and receiver modules
Dimension [mm]
Copyright © 2012, All rights reserved, Opticis Co., Ltd.
-4-
Aug. 03, 2012
M1-1P0E (Ver. 1.2)
www.opticis.com
DVI Pin Description
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
Symbol
CH2CH2+
GND
Functional Description
TMDS Data Signal Channel 2 Negative
TMDS Data Signal Channel 2 Positive
TMDS Data Signal Channel 2 Shield
DDC Clock
DDC Data
N.C.
CH1CH1+
GND
DDC Clock line for DDC2B communication
DDC Data line for DDC2B communication
14
5V
15
GND
Hot plug
Detect
CH0CH0+
GND
5 V Input for Transmitter from Host
5 V Output for Monitor from Receiver
Ground
Signal is driven by monitor to enable the system to identify the presence
of a monitor
TMDS Data Signal Channel 0 Negative
TMDS Data Signal Channel 0 Positive
TMDS Data Signal Channel 0 Shield
GND
CLK+
CLK-
TMDS Clock Signal Shield
TMDS Clock Channel Positive
TMDS Clock Channel Negative
16
17
18
19
20
21
22
23
24
TMDS Data Signal Channel 1 Negative
TMDS Data Signal Channel 1 Positive
TMDS Data Signal Channel 1 Shield
Note: Channels 3, 4 and 5 dual-link data signal pins are not used
Copyright © 2012, All rights reserved, Opticis Co., Ltd.
-5-
Aug. 03, 2012
M1-1P0E (Ver. 1.2)
www.opticis.com
Reliability Test
Opticis utilizes three types of test criteria for a reduction of variability and a continuous improvement of
the process by its FEMA (Failure Mode and Effective Analysis) program.
1) Mechanical test (vibration, shock)
2) Temperature & humidity tests
3) EMC test (FCC class A and CE Verification)
Mechanical and Temperature & Humidity Test Data
Heading
Operating
Test
Storage
Test
Test
Operating at each
Temperature
Conditions
Duration
Sample
Failure
Size
30 Min
* - 0 ~ 50 °C
(Each
(Interval: 10 °C)
n =4
0
Temperature)
(See Note)
Remarks
Note:
Visual
Test
the Display
Low Temperature
* TS = -30 °C
96 HR
n=2
0
1. TS: Storage Temperature
High Temperature
* TS = 70 °C
96 HR
n=2
0
2. RH: Relative Humidity
High Humidity
* TS: 85 °C
High Temperature
96 HR
n=2
0
* RH: 85%
-
n=2
0
-
n=2
0
Mechanical
Shock
* Pulse: 11 ms
* Peak level: 30 g
* Shock pulse: 3 times/Axis
Mechanical
Test
* Peak acceleration: 20 g
Mechanical
* Frequency: 20~2000 ㎐
Vibration
* Sweep time: 30 Minutes
* 4 Times/Axis
Copyright © 2012, All rights reserved, Opticis Co., Ltd.
-6-
Aug. 03, 2012
on
M1-1P0E (Ver. 1.2)
www.opticis.com
EMC Test Data
1) EMI: Meet FCC class A (ICES-003) and CE class A
STANDARDS
EN 55 022 (CISPR22)
CE (Conducted Emission) &
FCC; PART 15 SUBPART B
RE (Radiated Emission)
EN 61000-3-2 (IEC 61000-3-2)
Harmonics
EN 61000-3-3 (IEC 61000-3-3)
Flickers
CONDITIONS
Meet Class A
Meet Class A
Meet Class A
2) EMS: Meet CE standards (EN 55024) and CISPR24 equivalents
EN 61 000-4-2:1995
EN 61 000-4-3:1996
EN 61 000-4-4:1995
EN 61 000-4-5:1995
EN 61 000-4-6:1996
EN 61 000-4-11:1994
STANDARDS
Electrostatic Discharge Immunity
(Air: 8kv, Contact: 4kv)
Radiated RF E-Field (80~1000 MHz)
3V/m (AM 80%, 1kHz)
Fast Transients (5kHz, 60Seconds)
Surge Transients
Conducted Susceptibility (CS)
Radiated Susceptibility (RS)
Voltage Dips, Interruption & Variation
CONDITIONS
Meet Criterion B
Meet Criterion A
Meet Criterion B
Meet Criterion B
Meet Criterion A
Meet Criterion C
Terminology
DDC
DVI-D
EDID
EMI
EMS
HDCP
PDP
RFI
TFT-LCD
TMDS
VCSEL
VESA
Digital Display Channel. Latest specification is DDC2B.
Digital Visual Interface. Digital connection only – no analog.
Extended Display Identification Data. EDID parameters are sent over the DDC link.
Electro Magnetic Interference.
Electro Magnetic Susceptibility.
High Definition Content Protection. These parameters are part of the 2002 High
Definition Multimedia Interface (HDMI) specification for Consumer Electronics.
Plasma Display Panel. Large HDTV panels up to 63” use this display technology.
Radio Frequency Interference.
Thin Film Transistor Liquid Crystal Display – the technology of most computer display
panels with VESA resolutions up to 1600x1200 pixels.
Transmission Minimized Differential Signalling is the Silicon Image Inc. protocol for
the digital signals.
Vertical Cavity Surface Emitting Laser transmitter diode. The receiver diode is the
PIN-Photo Diode. These components are designed and manufactured by Opticis.
Video Electronics Standards Association.
Copyright © 2012, All rights reserved, Opticis Co., Ltd.
-7-
Aug. 03, 2012