M1-1000 (Ver. 1.0) www.opticis.com DATA SHEET DVI - HDCP Extension Cable M1-1000-xx Contents ♦ Description ♦ Features ♦ Absolute Maximum Ratings ♦ Recommended Operating Conditions ♦ Electrical Power Supply Characteristics ♦ Receiver Electrical Interface ♦ Specifications of fiber-optic cables ♦ Drawing of transmitter and receiver modules ♦ DVI Pin Description ♦ Reliability Test of Modules ♦ Terminology Headquarters North American Office Opticis Co., Ltd # 501, Byucksan Technopia 434-6 Sangdaewon-Dong, Chungwon-Ku Sungnam City, Kyungki-Do, 462-120 South Korea Tel: +82 (31) 737-8033 Fax: +82 (31) 707-8079 Email: [email protected] www.opticis.com Opticis North America, Inc. 330 Richmond Street, Suite 100, Chatham, Ontario CANADA N7M 1P7 Tel : (519) 355-0819 Fax : (519) 355-0520 Copyright © 2003, All rights reserved, Opticis Co., Ltd. Email : [email protected] 02 January 2006 M1-1000 (Ver. 1.0) www.opticis.com Optical DVI - HDCP Extension Cable * Point-to-point optical fibre cable * Description The reality of gigabit high-speed digital graphic interconnections mandates products that maintain front-of-screen video quality. Optical technology extends the ability to transmit digital graphic data beyond the physical limits of copper wires by, i) providing pure signal integrity over long distances for the optimum visual experience, ii) no EMI/RFI transmission or reception, iii) light weight, rugged cabling and connectors, iv) very cost effective per foot/metre, v) low power consumption, and vi) plug and go installation ease – no software requirements. The M1-1000 consists of a transmitter and a receiver, connected by all fiber-optic distribution cables with male DVI-D connectors at each end. The Transmitter and Receiver modules are respectively implemented by Opticis designed and manufactured 850nm VCSEL and PIN-PD arrays. The M1-1000 product makes DDC / HDCP interconnection over pure fibers as well as transmission of the Red, Green, Blue, and Clock TMDS graphic data over fibers. The cable can be any length up to 500m (326feet) for WUXGA (1,920x1,200) 60Hz data. An external power is required for the receiver module, while most video cards, at least 500mA of +5V voltage can provide DC power to the transmitter module. The shipping group is as follows; 1) One DVI / HDCP cable: M1-1000-yyy, where y = length in metres. 2) Factory will stock “standard” lengths of 10m, 20m, 30m and 50m. 3) User Manual Copyright © 2003, All rights reserved, Opticis Co., Ltd. -1- 02 January 2006 M1-1000 (Ver. 1.0) www.opticis.com Feature ♦ Supports all VESA resolutions up to WUXGA (1,920x1,200), at 60Hz refresh rate with 1 pixel/clock mode. ♦ Embeds pure fiber distribution cable with 8 strands Multimode Glass of fibers not only for the TMDS video interface and but also to support the DDC2B/HDCP, which offers perfect electrical isolation. ♦ Extends up to 500 meters (1,560 feet). ♦ Applicable of both powers from graphic cards and an external adaptor for the transmitter while powering the receiver from an external +5V adaptor. ♦ Compact end connector design easily allows direct connect to the host video card and display peripheral. ♦ No software to install; just plug and go. ♦ Data security with negligible RFI/EMI emissions Applications ♦ Digital display system integration for medical, military, aerospace, factory automation, and traffic control platforms. ♦ Digital FPD, PDP and projector installation in conference rooms, auditoriums and for kiosk systems ♦ LED signboards for large scale information display and stadiums ♦ Home Theatre Systems Copyright © 2003, All rights reserved, Opticis Co., Ltd. -2- 02 January 2006 M1-1000 (Ver. 1.0) www.opticis.com Absolute Maximum Ratings Parameter Storage Temperature Supply Voltage Transmitter Differential Input Voltage Relative Humidity Lead Soldering Temperature & Time Symbol Tstg VCC Vd RH - Minimum - 30 - 0.3 10 - Maximum + 70 + 6.0 1 85 Units °C V V % 260°C, 10 sec Recommended Operating Conditions Parameter Ambient Operating Temperature Data Output Load Power Supply Rejection (Note1) Supply Voltage Graphic Supply Voltage (Note2) Symbol TA RLD PSR VCC GVCC Minimum 0 + 4.5 + 3.0 Typical 50 50 + 5.0 + 3.3 Maximum + 50 + 5.5 + 3.6 Units °C Ω mVp-p V V Note1. Tested with a 50mVp-p sinusoidal signal in the frequency range from 500 Hz to 500 MHz on the VCC supply with the recommended power supply filter in place. Typically less than a 0.25 dB change in sensitivity is experienced. Note2. Graphic Supply Voltage is only for the Graphic Signal Interface, which is generated by regulator in the Transmitter and Receiver Electrical Power Supply Characteristics (TA = 0 °C to +50 °C, unless otherwise noted) Parameter Supply Voltage Supply Current Power Dissipation TX RX TX RX Symbol VCC ITCC IRCC PTX PRX Minimum 4.5 - Copyright © 2003, All rights reserved, Opticis Co., Ltd. -3- Typical 5 180 180 0.9 0.9 Maximum 5.5 200 200 1.1 1.1 Units V mA mA W W 02 January 2006 M1-1000 (Ver. 1.0) www.opticis.com Specifications of Fibre-Optic Cables Parameter Core Diameter Coating Diameter Proof Test Level Value 62.5±3.0um 245±15um > 100kpsi Parameter Cladding Diameter Outside Diameter Value 125±2.0um 5.5±0.2mm Drawing of transmitter and receiver modules Dimension [mm] Copyright © 2003, All rights reserved, Opticis Co., Ltd. -4- 02 January 2006 M1-1000 (Ver. 1.0) www.opticis.com DVI Pin Description Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 Symbol CH2CH2+ GND Functional Description TMDS Data Signal Channel 2 Negative TMDS Data Signal Channel 2 Positive TMDS Data Signal Channel 2 Shield DDC Clock DDC Data N.C. CH1CH1+ GND DDC Clock line for DDC2B communication DDC Data line for DDC2B communication TMDS Data Signal Channel 1 Negative TMDS Data Signal Channel 1 Positive TMDS Data Signal Channel 1 Shield 14 5V 15 GND Hot plug Detect CH0CH0+ GND 5 V Input for Transmitter from Host 5 V Output for Monitor from Receiver Ground Signal is driven by monitor to enable the system to identify the presence of a monitor TMDS Data Signal Channel 0 Negative TMDS Data Signal Channel 0 Positive TMDS Data Signal Channel 0 Shield GND CLK+ CLK- TMDS Clock Signal Shield TMDS Clock Channel Positive TMDS Clock Channel Negative 16 17 18 19 20 21 22 23 24 Note: Channels 3, 4 and 5 dual-link data signal pins are not used Copyright © 2003, All rights reserved, Opticis Co., Ltd. -5- 02 January 2006 M1-1000 (Ver. 1.0) www.opticis.com Reliability Test Opticis utilizes three types of test criteria for a reduction of variability and a continuous improvement of the process by its FEMA (Failure Mode and Effective Analysis) program. 1) Mechanical test (vibration, shock) 2) Temperature & humidity tests 3) EMC test (FCC class B and CE Verification) Mechanical and Temperature & Humidity Test Data Heading Operating Test Test Operating at each Temperature (See Note) Conditions Duration Sample Failure Size 30 Min * -10 ~ 70 °C (Each (Interval: 10 °C) n =3 0 Temperature) Remarks Note: Visual Test on the Display Low Temperature * TS = -30 °C 96 HR n=3 0 1. TS: Storage Temperature Storage High Temperature * TS = 80 °C 96 HR n=3 0 2. RH: Relative Humidity Test High Humidity * TS: 85 °C High Temperature * RH: 85% 96 HR n=3 0 - n=2 0 - n=2 0 Mechanical Shock Mechanical Test * Pulse: 11 ms * Peak level: 30 g * Shock pulse: 3 times/Axis * Peak acceleration: 20 g Mechanical * Frequency: 20~2000 ㎐ Vibration * Sweep time: 30 Minutes * 4 Times/Axis Copyright © 2003, All rights reserved, Opticis Co., Ltd. -6- 02 January 2006 M1-1000 (Ver. 1.0) www.opticis.com EMC Test Data 1) EMI: Meet FCC class B (ICES-003) and CE class B STANDARDS EN 55 022 (CISPR22) CE (Conducted Emission) & FCC; PART 15 SUBPART B RE (Radiated Emission) EN 61000-3-2 (IEC 61000-3-2) Harmonics EN 61000-3-3 (IEC 61000-3-3) Flickers CONDITIONS Meet Class B Meet Class B Meet Class B 2) EMS: Meet CE standards (EN 55024) and CISPR24 equivalents EN 61 000-4-2:1995 EN 61 000-4-3:1996 EN 61 000-4-4:1995 EN 61 000-4-5:1995 EN 61 000-4-6:1996 EN 61 000-4-11:1994 STANDARDS Electrostatic Discharge Immunity (Air: 8kv, Contact: 4kv) Radiated RF E-Field (80~1000 MHz) 3V/m (AM 80%, 1kHz) Fast Transients (5kHz, 60Seconds) Surge Transients Conducted Susceptibility (CS) Radiated Susceptibility (RS) Voltage Dips, Interruption & Variation CONDITIONS Meet Criterion A Meet Criterion A Meet Criterion A Meet Criterion A Meet Criterion A Meet Criterion A and C Terminology DDC DVI-D EDID EMI EMS HDCP PDP RFI TFT-LCD TMDS VCSEL VESA Digital Display Channel. Latest specification is DDC2B. Digital Visual Interface. Digital connection only – no analog. Extended Display Identification Data. EDID parameters are sent over the DDC link. Electro Magnetic Interference. Electro Magnetic Susceptibility. High Definition Content Protection. These parameters are part of the 2002 High Definition Multimedia Interface (HDMI) specification for Consumer Electronics. Plasma Display Panel. Large HDTV panels up to 63” use this display technology. Radio Frequency Interference. Thin Film Transistor Liquid Crystal Display – the technology of most computer display panels with VESA resolutions up to 1600x1200 pixels. Transmission Minimized Differential Signalling is the Silicon Image Inc. protocol for the digital signals. Vertical Cavity Surface Emitting Laser transmitter diode. The receiver diode is the PIN-Photo Diode. These components are designed and manufactured by Opticis. Video Electronics Standards Association. Copyright © 2003, All rights reserved, Opticis Co., Ltd. -7- 02 January 2006