OPTOTRONIC® LED Power Supply Product Data Sheet OT FIT 80/220-240/1A6 CS L Constant current LED driver 1200 mA – 1400 mA – 1550 mA The reliable choice for the essential lighting: based on the well tested Quicktronic® core and flat metal housing 30 x 21 mm fits in all linear and area light fixtures for office - industrial - shop lighting. Benefits Three fixed selectable output currents Easy current selection using a wire bridge Long lasting and high reliability Slim metal housing Double output connectors (parallel connection) Suitable for emergency lighting units Applications Linear and area lighting Office – industrial - shop Housing material: metal, white painted. Approval marks SELV equivalent In preparation, if not already printed on product label. Product Features 3 output currents 1200/1400/1550 mA Overload protection Default output current is 1550 mA Overtemperature protection Wire bridge to select the current Load hot plug protection SELV equivalent 27 – 54 V 100’000 h lifetime at tc = 65°C Output power up to 83 W Case temperature up to 75 °C Mains voltage 220 – 240 V Wide ta range -25 – +50 °C Suitable for emergency lighting 5 years guarantee 1 Edition: 02 Jun. 2014 Ver.: 1.9 Status: Released OPTOTRONIC® LED Power Supply OT FIT 80/220-240/1A6 CS L Product Data Sheet INPUT Electrical Specifications Item Nominal voltage Nominal frequency AC voltage range DC voltage range Maximum voltage Nominal current Total Harmonic Distortion (THD) Power factor Efficiency Power losses No-load power Stand-by power Protection class Inrush current Max. units per circuit breaker OUTPUT Leakage current Nominal voltage range Maximum voltage Nominal current range Current accuracy Current ripple Nominal power range Maximum power ENVIRONMENT DIMMING Galvanic isolation Dimming control Dimming range Dimming technique Frequency Galvanic isolation Ambient temperature range ta Maximum case temperature tc Max. case temp. in fault condition Storage temperature range Relative humidity Surge transient protection Environmental rating IP rating Mains switching cycles Expected lifetime Value 220 – 240 0 / 50 - 60 198 – 264 176 – 276 320 0.40 < 10 > 0.95 > 87 13.4 n/a n/a I 53 B16: 28; B10: 17 < 0.5 27 – 54 60 1200 / 1400 / 1550 +/- 10 < 10 32 – 83 83 SELV equivalent no n/a n/a n/a n/a -25 …+50 75 110 -25 …+75 5 ... 85 1|2 Indoor IP 20 > 100’000 50’000 100’000 Unit V Hz V V Vac A % % W W W A pk Remarks DC not implemented in this Engineering Samples DC not implemented in this Engineering Samples 2 h maximum, unit might not operate in this abnormal condition Full load, 220 – 240 V, 50 Hz / see graphs Full load, 220 – 240 V, 50 Hz / see graphs Full load, 220 – 240 V, 50 Hz / see graphs Maximum, full load Load switching on output side is safe but not permitted Unit is not dimmable/controllable PE can be connected to terminal or housing Max, th = 230 μs I max = 53 A Th = 230 μs mA V V mA Through PE, output floating % % W W For each single operating points of the output characteristic Ripple / average @ 100 Hz, full load No load protection put output down to roughly 1…2 V 1550 mA default (terminals 5-6-7 open) Output to mains - Touch current < 0.5 mA Not dimmable °C °C °C °C % kV h Measured on tc point indicated of the product label Not condensing L/N | LN/PE acc to. EN 61547 Clause 5.7 tc = 75°C, 0.2% / 1’000 h failure rate, 14 h ON / 10 h Stan-by per day tc = 65°C, 0.1% / 1’000 h failure rate, 14 h ON / 10 h Stan-by per day Protections Overtemperature, Overload, No load, Short-circuit, Input overvoltage, Output overvoltage, Output undervoltage See remarks on page 4. Wiring Diagram Connectors type: WAGO 250; Wires cross section both flexible and solid: 0.5 – 1.5 mm2, peeling length 8.5 – 9.5 mm Two or more units cannot be connected together on secondary side with any or more of the 21 … 24 terminals. 2 Edition: 02 Jun. 2014 Ver.: 1.9 Status: Released OPTOTRONIC® LED Power Supply Typical Operating window OT FIT 80/220-240/1A6 CS L Product Data Sheet Typical Efficiency over load Rated operating window Typical Power factor over load Typical THD over load 3 Edition: 02 Jun. 2014 Ver.: 1.9 Status: Released OPTOTRONIC® LED Power Supply OT FIT 80/220-240/1A6 CS L Product Data Sheet Remarks Input over voltage protection: mains up to 320 Vac, for two hours maximum, will not destroy both the unit and the load shut down of load might occur in this condition. Output short circuit protection: short circuit current is limited to approx. 1 A without damage to the unit, for unlimited time. See typical operating window graph for details. Be sure the load is designed to withstand the short circuit current as well. Output overload protection: the unit is intrinsically protected against over loading because the output voltage is limited. Output over voltage protection: shut down of load happens if U out exceeds 54V; mains switchover is needed to restart the unit. To avoid unexpected power off, be sure the LED module operating voltage never exceed 54, including cold start condition. EN 60598-1 ann. G and EN 61347-a ann. A Output under voltage operation: the unit is not damaged if the load voltage is lower than 27 V, but the load current increases up to the short circuit value, see typical operating window graph for details. Be sure the load is safely operated if this event might occur. EN 60598-1 ann. G and EN 61347-a ann. A No load operation: the unit is not damaged in this condition; the output voltage is lower than 2 V, which enables a safe LED load connection, but mains switchover is needed to power the load. Over temperature protection: the unit is protected against temporary overheating by automatic reduction of the output power. If tc exceed 85 °C approx. the output current is reduced down to approximately 850 mA. If tc exceed 105 °C approx. the load is shut down; The protection is automatically reversible, without mains switchover. EN 60598-1 ann. G and EN 61347-a ann. A Touch current: lower than 0.2 mA, according to EN 60598-1 ann. G and EN 61347-a ann. A Switchover time: lower than 0.5 s, both AC and DC mains. Output power hold time: > 4 ms, in case of mains dips. Emergency lighting: - this LED power supply is suitable for emergency light fixtures acc. to EN 60598-2-22. Caution for CS wire bridge: 5, 6, 7 – terminals not isolated from mains; mandatory use of basic insulated wire suitable for mains voltage. Standards Ordering information EN 61347-1 Product name Type EAN10 EAN40 NAED EN 61347-2-13 OT-FIT 80/220-240/1A6 CS L AA51635 4052899032781 4052899032798 n/a Pieces / box 20 EN 55015 EN 61547 EN 61000-3-2 EN 62384 Manufacturer’s address: Technical support: OSRAM GmbH Kunden Service Center Germany +49 (0)89-6213-60 00 Steinerne Furt 62 D-86167 Augsburg Germany www.osram.com 4 Edition: 02 Jun. 2014 Ver.: 1.9 Status: Released