OPTOTRONIC® LED Power Supply OTi DALI 60/220-240/550 D LT2 L Product Data Sheet OTi DALI 60/220-240/550 D LT2 L L Constant current LED driver incl. OSRAM DALI features – non isolated s Wide operating area up to 550mA, 1…100% dimmable W Flexible, reliable solution for energy saving lighting: DALI dimmable & programmable, embedded corridor functionality and advanced TouchDIM with daylight harvesting, constant lumen output. Automatic current set through the LEDSet interface. Benefits Wide operating range: 120 – 550mA Adjustable current via DALI programmable or LEDset2 Long lasting and high reliability. Small, slim white metal housing 30 x 21 mm. Suitable for emergency lighting units. 280 270 Applications Linear and area lighting. Office – industrial – shop Housing material: metal, white painted. Approval marks In preparation, if not already printed on product label Product Features Output current range 120 – 550mA Very wide operating window Fully digitally programmable Overload & -temperature protection Smart dimming down to 1% Very small dimensions Very high efficiency > 92% 100’000 h lifetime at tc = 65°C Low stand-by consumption < 0.3 W tc max = 75 °C Output power up to 60 W Wide ta range -25 – +60 °C Suitable for emergency lighting 5 years guarantee 1 Edition: 30. June 2014 Ver.: 1.0 Status: FINAL OPTOTRONIC® LED Power Supply OTi DALI 60/220-240/550 D LT2 L Product Data Sheet ENVIRONMENT Dimming OUTPUT INPUT Electrical Specifications Item Nominal voltage Nominal frequency AC voltage range DC voltage range Maximum voltage Nominal current Total Harmonic Distortion (THD) Power factor Efficiency Starting time Power losses Stand-by power Protection class Inrush current Max. units per circuit breaker PE current Nominal voltage range Maximum voltage Nominal current range Current accuracy Current ripple Nominal power range Maximum power DC Output current (EL) Galvanic isolation Value 220 – 240 0 / 50 / 60 198 – 264 176 – 276 350 0.30 < 10 > 0.95 > 92 ≤ 0.3 5 < 0.3 I 53 B16: 13; B10: 8 < 0.5 54 – 240 < 250 120 – 550 +/- 5 < 10 1.5 – 60 60 15 no Dimming control Dimming range Dimming technology yes 1…100 mixed % Frequency PWM > 450 Hz Ambient temperature range ta Maximum case temperature tc Max. case temp. in fault condition Storage temperature range Relative humidity Surge transient protection Environmental rating IP rating Mains switching cycles -25 …+60 75 120 -25 …+85 5 ... 85 1|2 Indoor IP 20 > 100’000 50’000 100’000 °C °C °C °C % kV Expected lifetime Unit V Hz V V Vac A % % s W W A pk mA V Vdc mA % % W W % Remarks Pulsating DC DC or pulsating DC 2 h maximum, unit might not operate in this abnormal condition Full load Full load, 220 – 240 V, 50 Hz / see graphs Full load, 220 – 240 V, 50 Hz / see graphs Maximum, full load PE can be connected either to terminal or housing Max, th = 300 μs I max = 53 A Th = 300 μs Through PE w/ Open Circuit LEDset open: 60mA; LEDset short: 120 mA With LEDset2 +/-8% low freq. ripple is negligible Dimmable down to 1.5W Preset value, adjustable via software Non-SELV DALI and TouchDIM 1...25% PWM, 25...100% amplitude h 1...25% Measured on tc point indicated of the product label Not condensing L/N | LN/PE acc to. EN 61547 Clause 5.7 tc = 75°C, 0.2% / 1’000 h failure rate, 24h ON tc = 65°C, 0.1% / 1’000 h failure rate, 24h ON Protections Overtemperature, Overload, No load, Short-circuit, Input overvoltage, Output overvoltage, Output undervoltage See remarks on page 4 1 – Mains 2 – Mains 3 – n/a 4 – PE 5 – n/a 6 – DALI 7 – DALI GRAY GRAY GRAY GRAY GRAY RED RED RED BLACK WHITE WHITE BLACK RED BLACK OTi DALI 60 Input & Output Pinning Output Pinning 21 – LED + 22 – LED – 23 – n/a 24 – LEDset 25 – LED-aux 26 – LED + 27 – LED – Max. 2m whole length excl. modules Output Pinning w/ ECG Internal Through Wiring 2 Edition: 30.June 2014 Ver.: 1.0 Status: FINAL OPTOTRONIC® LED Power Supply OTi DALI 60/220-240/550 D LT2 L Typical Operating window Product Data Sheet Typical Efficiency vs load 250 200 150 Rated operating area 100 50 0 0 50 100 150 200 250 300 350 400 450 500 550 600 Typical Power factor vs load Typical THD vs load Typical Iout vs Rset Rset formula and standard Iout values I OUT A 5V 1000 Rset Iout [mA] Iout [mA] nominal set, +/-5% 120 250 350 550 Rset [kOhm] -- -- (E24) 121 41.2 (E48) 250 20 (E24) 250 20.0 (E48) 333 15 (E24) 350 14.3 (E48) 549 9.1 (E24) 550 9.09 (E48) Refer to the LEDset2 application note and/or instruction sheet for further details 3 Edition: 30.June 2014 Ver.: 1.0 Status: FINAL OPTOTRONIC® LED Power Supply OTi DALI 60/220-240/550 D LT2 L Product Data Sheet Remarks Input over voltage protection: mains up to 350 Vac, for two hours maximum, will not destroy both the unit and the load; shut down of load might occur in this condition. Output short circuit / undervoltage protection: shut down of load happens if V_out is out of operating range Output overload protection: the unit automatically reduces the output current to keep the output power below 60W. Output over voltage protection: shut down of load happens if V_out exceeds 240V No load operation: the unit automatically switches off. Over temperature protection: the unit is protected against temporary overheating by automatic reduction of the output current when tc > 75°C Switchover time: lower than 0.5 s, both AC and DC mains. Output power hold time: > 4 ms, in case of mains dips. Emergency lighting: this LED power supply is suitable for emergency lighting fixtures acc. to EN 60598-2-22; according to IEC 61347-2-13 Annex J. Emergency Escape Lighting: this LED power supply is suitable for emergency escape lighting systems acc. to EN 50172 Standards Ordering information EN 61347-1 Product name Type EAN10 EAN40 NAED EN 61347-2-13 OTi DALI 60/220-240/550 D LT2 L AA6930800DG 4052899188662 4052899188679 n/a Pieces / box 20 EN 55015 EN 61547 EN 61000-3-2 EN 62384 EN 62386 Manufacturer’s address: Technical support: OSRAM GmbH Kunden Service Center Germany +49 (0)89-6213-60 00 Steinerne Furt 62 D-86167 Augsburg Germany www.osram.com 4 Edition: 30.June 2014 Ver.: 1.0 Status: FINAL