NNC50DWH2 Halogen Free Wiring Duct Divider Wall

ELECTRICAL SOLUTIONS
A.
System
Overview
Panduct ® Type NNC Halogen-Free Metric Wiring Duct
• Material: Halogen-free modified polyphenylene oxide (mPPO)
material as verified with IEC 60754-2 test method (test on gases
evolved during combustion of electric cables)
• UL recognized continuous use temperature: 203°F (95°C)
• UL 94 flammability rating of V-0
• Conforms with NFPA 79-2007 section 13.3.1 requirement for
flame retardant material
• Provided with DIN 43 659 mounting holes
• Metric sizing and finger progression
• Duct and cover packaged together in two meter lengths
B1.
Cable Ties
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
W
H
.98 TYP [25.0]
.39 TYP [10.0]
Duct Size (W x H)*
Slot Width
Base
and Replacement
Cover
Cover
Replacement Ctn.
Ctn.
Cover
Qty.
Qty.
Part Number
(m)
(m)
NC25LG2
20
20
NC25LG2
20
20
NC25LG2
20
20
NC25LG2
20
20
NC37LG2
20
20
Base and Cover
Part Number
NNC25X25LG2
NNC25X37LG2
NNC25X50LG2
NNC25X75LG2
NNC37X37LG2
mm
24.6 x 23.6
24.6 x 35.8
24.6 x 47.8
24.6 x 72.4
37.1 x 35.8
In.
.97 x .93
.97 x 1.41
.97 x 1.88
.97 x 2.85
1.46 x 1.41
In.
.39
.39
.39
.39
.39
mm
10.0
10.0
10.0
10.0
10.0
NNC37X50LG2
NNC37X75LG2
NNC50X50LG2
NNC50X75LG2
NNC50X100LG2
NNC75X75LG2
37.1
37.1
49.5
49.5
49.5
74.7
1.46
1.46
1.95
1.95
1.95
2.94
1.88
2.85
1.88
2.85
3.85
2.85
.39
.39
.39
.39
.39
.39
10.0
10.0
10.0
10.0
10.0
10.0
NC37LG2
NC37LG2
NC50LG2
NC50LG2
NC50LG2
NC75LG2
20
20
20
10
10
10
20
20
20
20
20
20
NNC100X50LG2
NNC100X75LG2
NNC100X100LG2
99.6 x 47.8
99.6 x 72.4
99.6 x 97.8
3.92 x 1.88
3.92 x 2.85
3.92 x 3.85
.39
.39
.39
10.0
10.0
10.0
NC100LG2
NC100LG2
NC100LG2
10
10
10
20
20
20
x
x
x
x
x
x
47.8
72.4
47.8
72.4
97.8
72.4
x
x
x
x
x
x
C1.
Wiring
Duct
C2.
Surface
Raceway
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
D2.
Power
Connectors
Available in LG (Light Gray) and WH (White).
Do not allow cutting, tapping, or cleaning fluids that contain hydrocarbons to come in contact with type NNC
wiring duct as it will cause stress cracking. See page C1.49 for a list of chemicals to avoid.
*"H" dimension includes duct and cover.
D3.
Grounding
Connectors
Multiple slot restrictors present with
75mm and greater duct wall height.
E1.
Labeling
Systems
Panduct Type NNC Divider Wall
®
• NNC solid divider wall can be mounted inside NNC and NE wiring
duct to create multiple channels
• Material: Halogen-free modified polyphenylene oxide (mPPO)
• Simply install the divider wall base when mounting the duct
and snap the divider wall onto mounting base, DB-C
Part Number
NNC50DWH2
Length
(m)
2
For Nominal
Duct Height
(mm)
50
NNC75DWH2
2
75
E2.
Labels
Std.
Pkg.
Qty.
2
Std.
Ctn.
Qty.
(m)
40
E3.
Pre-Printed
& Write-On
Markers
2
40
E4.
Permanent
Identification
Available in WH (White) color only.
NOTE: Must be used with mounting base DB-C (see page C1.26), which is sold separately. Install mounting bases
to the duct channel, locate within 2" of each divider wall end and at least every 12" along the length.
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)