Wiring Duct Product Selection Guide ™ Comprehensive Wiring Duct Solutions PVC Flush Cover Wiring Duct Standard 2m lengths, sold base and cover together. Type ENC, Narrow Slots, Narrow Fingers Type EWC, Wide Slots, Wide Fingers Halogen-Free Wiring Duct Low-Smoke, Halogen-Free Wiring Duct Standard 2m lengths, sold base and cover together. Standard 2m lengths, sold base and cover together. Type NNC, Wide Fingers, Wide Slots Type TNC, Wide Fingers, Wide Slots PanelMax™ Space Optimization and Noise Mitigation Products Type DRD, DIN Rail Wiring Duct* Type CWD, Corner Wiring Duct Shielded Wiring Duct EMI Noise Shield Standard 1.8m lengths, sold base and cover together. Uses standard covers sold separately** * DIN Rail not included. **Use cover part #: C2LG6 2 Standard 1.8m lengths. Uses standard covers sold separately** Wiring Duct Available Colors and Sizes Duct Size W x H (mm) 12 x 12 25 x 25 IG International Gray – RAL7030 EWC NNC FL NNC ENC NNC TNC NNC EWC 25 x 50 25 x 60 WH White FL ENC 25 x 37 25 x 40 LG Light Gray NNC ENC EWC ENC EWC 25 x 75 NNC NNC TNC NNC 37 x 37 NNC TNC NNC 37 x 50 NNC 37 x 75 NNC 25 x 80 40 x 25 ENC EWC 40 x 40 ENC EWC 40 x 60 ENC EWC 40 x 80 ENC EWC 40 x 100 ENC EWC NNC NNC TNC NNC 50 x 50 NNC 50 x 75 NNC NNC NNC NNC 50 x 100 60 x 40 ENC EWC 60 x 60 ENC EWC 60 x 80 ENC EWC 60 x 100 ENC EWC 75 x 75 80 x 40 ENC EWC 80 x 60 ENC EWC 80 x 80 ENC EWC 80 x 100 ENC EWC 100 x 40 ENC EWC 100 x 50 100 x 60 ENC FL TNC NNC TNC NNC NNC TNC NNC NNC TNC NNC EWC 100 x 75 100 x 80 ENC EWC 100 x 100 ENC EWC 120 x 40 ENC EWC 120 x 60 ENC EWC 120 x 80 ENC EWC NNC NNC 85.0 x 64.4* CWD CWD CWD 111.8 x 90.7* CWD CWD CWD 135.3 x 115.7* CWD CWD CWD 156.7 x 54.0** DRD DRD DRD 184.1 x 79.4** DRD DRD DRD 209.5 x 104.8** DRD DRD DRD *Corner Duct Profile **DIN Rail Duct Profile 3 Part Numbering System for Panduct® Wiring Duct ENC Type ENC=Narrow Slot EWC= Wide Slot NNC=Halogen-Free, Metric TNC =Low Smoke Halogen-Free FL =Flexible Duct 25 X Nominal Width mm 25 IG Nominal Height mm 2 — Color IG = International Gray – RAL7030 LG = Light Gray WH= White Length 2m Part Numbering System for Panduct® PanelMax™ DIN Rail Wiring Duct DRD Type DRD = DIN Rail Duct 22 IG 6 Color IG = International Gray – RAL7030 LG = Light Gray WH = White Size Capability Height 22 = 2"(50mm) Height 33 = 3" (80mm)Height 44 = 4" (100mm) Length 6 ft. (1.8m) Part Numbering System for Panduct® PanelMax™ Corner Wiring Duct CWD Type CWD = Corner Wiring Duct 2 IG 6 Color IG = International Gray – RAL7030 LG = Light Gray WH = White Size Capability Height 2 = 2" (50mm) Height 3 = 3" (80mm) Height 4 = 4" (100mm) Height Length 6 ft. (1.8m) Panduct® PanelMax™ Shielded Wiring Duct Panduct® PanelMax™ Noise Shield Shielded wiring duct is a standard PVC wiring duct with bridges between fingers and wrapped with an aluminum foil shield. Sold in 1.8m (6 ft.) lengths, available in three (3) sizes and uses standard covers. Noise shield is zinc-plated steel and black powder coated except at bonding locations. Each kit contains two (2) 0.9m (3 ft.) sections and four (4) bonding clips. 4 Size (H) mm (In.) Part Number Size (W x H) mm (In.) G2X2LG6EMI 50 x 50 (2" x 2") SD2EMI 50 (2") G2X3LG6EMI 50 x 75 (2" x 3") SD3EMI 75 (3") G2X4LG6EMI 50 x 100 (2" x 4") SD4EMI 100 (4") Part Number Wiring Duct Material Properties Rigid Polyvinyl Chloride (PVC) A general purpose lead-free material for indoor applications. It has a UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 50°C (122°F). Used in the manufacture of the following types of Panduit wiring duct and covers: ENC, EWC, CWD, and DRD. Modified Polyphenylene Oxide (mPPO) – Halogen Free A special purpose material for use in halogen-free or high-temperature applications. It has a UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95°C (203°F) and is 20% lighter than PVC. Used in the manufacture of the following type of Panduit wiring duct and covers: NNC. Polyphenylene Ether + High Impact Polystyrene (PPE+HIPS) A special purpose material for use in low-smoke, halogen-free, and high-temperature applications. It has a UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 105°C (221°F). Meets the regulatory requirements of the mass transit industry and other applications where fire and public safety are critical; such as in trains, buses, offshore oil and gas platforms, and other similar environments. Used in the manufacture of Type TNC wiring duct and covers. Polypropylene (PP) A flexible material with a UL 94 flame class of V-2 with a UL recognized continuous-use temperature up to 65°C (149°F). Used in the manufacture of Type FL flexible wiring duct. Recommended Precaution when using Type NE, NS, NNC, and TNC Wiring Duct Cleaning solvents and cutting fluids that contain any of the following chemical agents should not come into contact with these types of wiring duct or covers. These chemicals are the most commonly known to cause stress cracking. • Hydrocarbons • Phenols • Ketones • Amines • Ethers • Organic, inorganic, and oxidizing acids • Petrol Refer to www.panduit.com for more information on chemical resistance. Wiring Duct Cutting and Installation Tools PBDCT – Bench Mount Duct Cutting Tool DNT-100 – Duct Notching Tool DCT – Hand-Held Duct Cutting Tool TNR – Nylon Rivet Installation Tool DFCT – Duct Finger Cutting Tool Nylon Rivets: NR1-C – 100 pcs. NR1-M – 1000 pcs. Adhesive Tape – Available in various sizes Type FL – Flexible Wiring Duct; 3 sizes, 500mm lengths 5 Panduit Wiring Duct Approvals and Compliances Agency Mark Agency Requirement Classification/Performance Material Flame Class V-0 Continuous-use temperature up to 50°C (122°F) All wiring duct types and covers UL 1565 CSA C22.2 No. 18.5-03 Material Flame Class V-0 Continuous-use temperature up to 50°C (122°F) Type DRD UL 508 section 15 An insulating barrier material shall comply with the minimum material properties indicated in Table 15.1 UL 508 sections 34 and 181 Qualifies as a metal barrier with required thickness as indicated in Table 6.1 UL 1565 Underwriters Laboratories, Inc. File No. E147128 Underwriters Laboratories, Inc. Canadian Standards Association File No. 016446 Wiring Duct Types/Products Material Flame Class V-0 Continuous-use temperature up to 50°C (122°F) CSA C22.2 No. 18.5-02 PVC divider walls SD*EMI metal barrier All wiring duct types and covers • CDS (cable ducting system for impact 2 J) • Minimum storage, transport, installation, and application temperature: -5°C (23°F) • Maximum application temperature: 60°C (140°F) • Non-flame propagating • Without electrical continuity • Cover removable without a tool ENC, EWC, NNC, and TNC DIN 43659 • Specifies dimensions for slotted trunkings used in electrical switch-gear assemblies and that conform to DIN VDE 060 Part 506 • Channel mounting hole pattern, slot dimensions, pitch, and location • Distance from first to last like-size mounting hole • Minimum overall product length ENC, EWC, NNC, and TNC DIN 5510-2 DIN 54837 Burning Class: S4 Smoke Class: SR2 Dripping Class: ST2 Low Voltage Directive 2006/95/EC Conformity European EN 50085-1 EN 50085-2-3 DIN German Institute for Standardization Type NNC Wiring Duct Classification = F3/I4 Type TNC Wiring Duct Classification = F1/I4 AFNOR French Association of Normalization NF F 16-101 NF F 16-102 UNIFER Italian Railway Standards EN ISO 11925-2 FRA – Federal Railroad Administration 49 CFR Part 238 Pass 30-second flame application TNC NNC and TNC TNC Surface Flammability: < 35 Smoke Density Ds (1.5) < 100 Ds (4.0) < 200 TNC NFPA – National Fire Protection Association National Fire Protection Agency European Union NFPA130 NFPA 79-2012, Section 13.3.1 IEC 60332-1 Non-metallic duct shall be permitted (inside enclosures) only when they are made with a flame-retardant material; flame-retardant material is defined in the standard by the IEC 60332-1 test method All wiring duct types and covers (except FL) NFPA 79-2012, Section 13.5.2 Panduit publishes a maximum percentage wire fill for common wire types equal to 50% of the interior cross-sectional area of the wiring duct All wiring duct types and covers NFPA 79-2012, section 13.1.6.9 Panduit bend radius control accessories can be mounted at right angles and T junctions created using wiring duct in order to maintain cable bend radius control Corner strip with 1" bend radius control European Directive 2002/95/EC Meets the requirements on the Restriction of Hazardous Substances and is free of the six substances listed in the directive For more information Visit us at www.panduit.com Contact Customer Service by phone: 0044 (0)208 601 7219 or email: [email protected] All wiring duct products © 2014 Panduit Corp. ALL RIGHTS RESERVED. WDSG01--3!UKE 6/2014