Package Outline Drawing (POD)

Hermetic Packages for Integrated Circuits
Ceramic Quad Flatpack (CQFP)
0.012 M C A S - B S
R68.A
D S
68 LEAD CERAMIC QUAD FLATPACK PACKAGE
0.012 M C A S - B S
D
INCHES
D S
SYMBOL
D1
A
PIN NO. 1
L
e
A
A
-AE1
e2
E
-B-
e1
bxN
0.008 M
A S -B S
C
D S
MIN
MILLIMETERS
MAX
0.075
MIN
0.135
1.91
3.43
-
0.016
0.023
0.41
0.58
2
b1
0.016
0.020
0.41
0.51
2
c
0.008
0.015
0.20
0.38
2
c1
0.008
0.012
0.20
0.31
2
D
1.640
1.870
41.66
47.50
-
E
1.640
1.870
41.66
47.50
-
D1
0.940
0.960
23.88
24.38
-
E1
0.940
0.960
23.88
24.38
4
e
0.050 BSC
-
0.012
-
0.31
-
-
e2
0.012
-
0.31
-
-
L
0.350
0.450
8.89
Q
0.070
0.120
1.78
M
-
0.0015
-
68
11.43
3.05
0.04
68
6
2
3
Rev. 0 11/19/96
c
A
Q
-C(b)
b1
SECTION A-A
1.27 BSC
e1
N
c1
NOTES
b
-D-
M
MAX
(c)
NOTES:
1. Index area: A notch or a pin one identification mark shall
be located adjacent to pin one and shall be located within
the shaded area shown. The manufacturer’s identification
shall not be used as a pin one identification mark.
2. Dimensions b1 and c1 apply to lead base metal only.
Dimension M applies to lead plating and finish thickness.
The maximum limits of lead dimensions b and c or M shall
be measured at the centroid of the finished lead surfaces,
when solder dip or tin plate lead finish is applied.
3. N is the maximum number of terminal positions.
4. Measure dimension e1 at all four corners.
5. For bottom-brazed lead packages, no organic or polymeric materials shall be molded to the bottom of the package
to cover the leads.
6. Dimension Q shall be measured at the point of exit (beyond
the meniscus) of the lead from the body. Dimension Q minimum shall be reduced by 0.0015 inch (0.038mm) maximum-when solder dip lead finish is applied.
7. Dimensioning and tolerancing per ANSI Y14.5M - 1982.
8. Controlling dimension: Inch.
58